Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC Awarded being L1 | |
| 2 | L2₹33.9 L+₹7.0 L (26.0%)Rejected-AOC | L2 | Rejected-AOC Not awarded being not L1 | |
| 3 | L3₹33.9 L+₹7.0 L (26.2%)Rejected-AOC | L3 | Rejected-AOC Not awarded being not L1 | |
| 4 | L4₹35.5 L+₹8.6 L (31.9%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-AOC Not awarded being not L1 |
Tender Value
₹44.0 L
EMD Value
₹87,940
Closing Date
18 Aug 2023, 6:00 pmClosed
GE (MES) ROORKEE
GARRISON ENGINEER ROORKEE
REPAIR/ MAINT TO INTERNAL WIRING INCL SUB MAIN WIRING, FANS, GEYSERS, COOLING APPLIANCES AND CONNECTED ITEMS FOR OTM ACCN AND MD ACCN AT RTS AND DEPOT SAHARANPUR UNDER GE ROORKEE
2023_MES_610050_1
8392/288/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAHARANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹87,940
Yes
18 Nov 2023
21 Jul 2023
21 Aug 2023
21 Jul 2023
18 Aug 2023
4 Aug 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings such as switches, ceiling rose, pendant, regulator, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc
M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick and including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following :-
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch
(c) One bell/buzzer point controlled by one push button
(d) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in before but wiring in existing conduit for the following :-
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch and fan regulator
(c) One bell/buzzer point controlled by one push button complete
(d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in but with 2.5 Sqmm (nominal area) FRLS cable PVC for 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity all as specified.
All as per item No 2 above here in but in existing conduit with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity all as specified.
M&L for point wiring complete with PVC insulated and unsheathed, flame retardant low smoke (FRLS) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia, clip, with suitable MS terminal boxes (not less than 1.0 mm thick )and including earth dolly with 3 mm thick sheet top cover of approved colours including 1.50 sqmm green stranded copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and as directed.
(a) One light point controlled by one switch
(b) one fan point controlled by one switch & regulator.
(c) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
(d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 16 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke (FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
Supply and fixing in replacement of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, down through and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.).
Supply and fixing in replacement of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 6.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes in PVC casing and capping approprite size with accessories and fittings and one run of 6 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of in PVC casing and capping shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
S&F in replacement switch piano flush type polycarbonate single pole one way 5 Amps.
S&F in replacement switch piano flush type polycarbonate single pole one way 15 Amps.
S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type.
S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type.
S&F in replacement bell push flush type 5 Amps
S&F in replacement Ceiling rose 3 phase/PVC/polycarbonate, insulated body.
S&F in replacement steped type electrronic fan regulator flush type all as specified.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F in replacement Modular switch 1 way 6A, 1 module complete,
S&F in replacement Modular switch 1 way 10A, 1 module complete
S&F in replacement Modular switch 1 way 16A, 1 module complete,
S&F in replacement Modular Bell push 6A 1 module complete,
S&F in replacement Socket, 6A - 2/3 pin combined 2 module complete,
S&F in replacement Socket, 6A/16A - 2/3 pin combined 2 module complete,
S&F in replacement Fan step regulator, 120W - 2 module complete,
S&F in replacement White cover plate with frame, 1 module complete,
S&F in replacement White cover plate with frame, 2 module complete,
S&F in replacement White cover plate with frame, 3 module complete,
S&F in replacement White cover plate with frame, 4 module complete,
S&F in replacement White cover plate with frame, 6 module complete,
S&F in replacement White cover plate with frame, 8 module complete,
S&F in replacement modular metal flush box 1/2 module
S&F in replacement modular metal flush box 3 module
S&F in replacement modular metal flush box 4 module
S&F in replacement modular metal flush box 6 module
S&F in replacement modular metal flush box 8 moudle
S&F in replacement electric bell ding dong single phase, AC 230 volts complete all as specified,
S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 12 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 8 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof vertical TPN 8 way, with MCCB of 160A, with breaking capacity 36 KA, IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /SEIMENS
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & nutral and current carrying capacity SPN 32 AMP, in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & nutral and current carrying capacity SPN 40 to 63 AMP, in the MCB DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning.
S&F single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps 240 volt grade
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimentions in PCC 1:2:4 type B1 RCC cover with GI handle, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion.
M&L Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 25mm x4mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified &shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal , salt, funnel & GI pipe 40 mm dia light grade, all as directed at site.
Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 40 200mm) complete, using GI earth earth Strip 32 x 6 mm connected to earth rod at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of HT/LT all as specified and directed. Note :- On testing after completion of job, if desired earth resistance (i.e. less than five Ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
9. Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 40 200mm) complete, using copper wire 6.0 sqmm dia connected to earth rod at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of LT poles all as specified and directed. Note :- On testing after completion of job, if desired earth resistance (i.e. less than five Ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Supply and fixing in replacement of 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 6 Sqmm all as specified.
Supply and fixing in replacement of 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 10 Sqmm all as specified.
S&L in replacement of XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 10 Sqmm and 2 core all as specified and directed
S&L in replacement of XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 16 Sqmm and 2 core all as specified and directed
S&L in replacment of XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 25 Sqmm and 3.5 core all as specified and directed
Supply and fixing house service bracket in replacement (hook type) complete with 3.0 mtrs long GI pipe 40 mm dia medium grade two nos 90 degree bends, MS hook and stay or guy complete all as specified
M&L for laying GI tubing light grade 40 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified.
M & L for Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
M & L for Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
M & L for Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed by Engr - in - Charge. (Note:- Punning thickness shall be measured)
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
S&F bulk head fittings IP-65, surface mounted comprising LED luminaire 9/10W of high brightness complete all as specified and directed.
Supply and fixing in replacement Wall light fixture lantern made up of polycarbonate suitable for 9 watt LED bulb complete with 9 watt LED bulb including connection with all necessary accessories complete all as specified and directed by Engr-In-Charge.
S&F in replacement of LED Tube light fitting 20 Watt surface and wall mounted LED batten, extruded polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed .
Supply and fixing in replacement of building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35/36 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete all as specified and directed.
S&F in replacement of Gate lights/post top light with 20 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engr-In-Charge.
Supply and fixing decorate gatelight globe (round size) made up of high grade unbreakable polycarboneate material suitable for retrofit LED lamp B22 base
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F LED luminaire 600 mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Labour only for attending and repairing day to day complaints of internal electrification and repairing in situ by skilled electrician alongwith a helper and making functional faulty points i.e. fixing necessary electric fittings (switch, socket, holder, Tube light, bell, regulator, Capcitor etc) complete all as specified and directed at site. (Note : - Point wiring will be measured and paid separately under appropriate item, fixing in repairs will be measured in appropriate item.)
Note :- (a) The trade men shall be equipped with all necessary Electrician tool kit, the rate of the same shall be included in the quoting rates. (b) The trade men shall report at complaint cell at 0930 Hrs. (c) Old Unsv items retreived against new shall be taken on schedule of credit (d) Replaced electrical switches/sockets and fittings will be measured as per site requirement against item no. 60 to 73. (e) Fixing in repairs will be measured against item no.60 to 86. (f) while quotating rates against item no. 58; 8 hrs of complaint duty for both electrician and helper shall be considered.
supply only switch piano, flush type single pole one way 5 Amps
supply only switch piano flush type polycarbonate single pole one way 15 Amps.
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type.
supply only socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type.
supply only bell push flush type 5 Amps
supply only Ceiling rose 3 phase/PVC/polycarbonate, insulated body.
supply only steped type electrronic fan regulator switch type all as specified.
supply only steped type electrronic fan regulator socket type all as specified.
supply only lamp holder PVC/poly carbonate back plate suitable for batten fittings
supply only LED tube light fittings 18/20 Watt surface and wall mounted LED batten. Make : Havells / phillips/crompton
Supply only moudular switch 1 way 6 A, 1 moudle
supply only modular socket 6A-2/ pin combined 2 moudle
Supply only modular socket 6A/16A -2/3 pin combined 2 module
Supply only moudlar fan reuglator 120W, 2 module
Supply and fix in replacment of single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, confirming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH. Make : L&T or equivalemnt in HPL (old meter to be deposit in MES store nd takenon ledger charge)
Supply and fix in replacement of three phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, confirming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH. Make : L&T or equivalemnt in HPL (old meter to be deposit in MES store nd takenon ledger charge)
S&F in replacment of PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mm and 50 mm deep
S&F in replacment of PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mm and 50 mm deep
Supply and fix double pole, RCBOs of 40Amp, 30mA for protection against earth leakage, overload & short-circuit protection in MCB DBs all as specified and directed
S&F round shape 16 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fix 80 watt LED well glass clear diffuser light, with provision of deidicated mounting eyebolt with PDC aluminium housing with polycarbonate diffuser all as specified and directed.
Supply and fix 100 watt LED highbay light, with provision of deidicated mounting eyebolt /bracket built in PDC aluminium housing, SMD LED array with integrated lens polycarbonate cover all as specified and directed.
S&F of landscape cylindrical shape LED bollard light with integrated driver, including establishing on ground connecting to the existing cable and make it functional all as specified and directed at site.
Taking down ceiling/exhaust/wall mounted fan of any size and sweep from its position dismantling fan for servicing and overhauling of following type and size of Fan by dismantling carefully and removing & changing unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including re-assembling, re-fixing in existing position and connecting to electrical system, testing etc complete at site all as specified & directed Engineer-in-Charge.(Note : Bearing, bush, condenser and painting shall be measured and paid separately.)
(a) Ceiling Fan complete up to 1400 mm Sweep
(b) Ceiling fan complete 1200 mm Sweep
(c) Exhaust Fan up to 450 mm Sweep
(d) Wall mounted fan up to 400 mm sweep
Supply & fix following items for replacement of defective accessories :-
(a) Ball bearing for ceiling Fan No 6201 (Make : TATA/NBC/SKF)
(b) Ball bearing for ceiling Fan No 6202 (Make : TATA/NBC/SKF)
(c) Ball bearing for ceiling Fan No 6203 (Make : TATA/NBC/SKF)
(d) Ball bearing for ceiling Fan No 6204 (Make : TATA/NBC/SKF)
(e) Ball bearing for exhaust Fan of 300/450 mm sweep.
(f) Ball bearing for wall mounted Fan of 300/450 mm sweep.
(g) Gun metal bush suitable for 1200/1500 mm sweep ceiling Fan.
(h) Fan condenser of capacity 2.5 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(j) Fan condenser of capacity 3.15 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(k) Fan condenser of capacity 4 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(l) Rubber bush with split pin for ceiling fan
(m) Armature shaft for Ceiling Fan
Materials and labour for rewinding of following Fans with heavy duty super enameled copper wire of existing gauge including all insulation materials, varnishing, heating etc complete all as directed by Engineer-in-Charge :-
(a) Ceiling Fan complete 1200 mm Sweep
(b) Ceiling Fan complete 1400 mm Sweep
(c) Exhaust Fan upto 350 mm Sweep
(d) Exhaust Fan 350 to 450 mm Sweep
(e) Wall mounted fan upto 400 mm sweep
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine spray painting with marking fan number including cleaning, washing and preparation of old painted surfaces complete all as directed by EIC:-
(a) Ceiling fan upto 1400 mm sweep complete.
(b) Ceiling fan upto 1200mm sweep complete
(c) Exhaust fan upto 450 mm sweep with black paint.
(d) Wall mounted fan upto 400 mm sweep.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified.
S&F canopy for ceiling fan of existing size & make as required at site all as specified and directed by EIC
Supply and replace down rod heavy grade 15 mm dia complete with drilling holes , cutting making threads as per requirement length up to 1.25 mtr , white paint all as specified and directed
S&F exhaust fan blade set complete suitable for 300/350/450 mm size any make /type or as required at site.
S&F exhaust fan frame with clamps, bolt, nuts and louver of suitable size and as required at ground for 300/350/450 mm sweep.
S&F in replacement hanging clamp with bolt, nut, washer, of appropriate size suitable for down rod of ceiling fan any sweep, specification as per existing or samples, all as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated .(old ceiling fan to be deposit in MES store and taken on ledger charge)
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz 1200, Copper winding of sweep 300m (old exhasust fan to be deposit in MES store and taken on ledger charge)
S&F exhaust fan, steel body AC single phase, 230 V of size 300mm sweep with, blades, and frame and louvers (old exhasust fan to be deposit in MES store and taken on ledger charge)
S&F wall mounted fans with its accessories, 230V, 400 mm sweep. Make : Havells/Crompton/USHA (old wall mounted fan to be deposit in MES store and taken on ledger charge)
Supply and fix PVC insulated multistrand Copper Cable 3 core size 1 sq mm, in white colour for light fittings and for fan connections from ceiling rose to electric fittings
Taking down carefully geysers of any make and capacity, transporting to MES E/M yard for dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of tank thoroughly with washing compound or liquid solution, applying one coat of milky white synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint and re-fixing of geysers at its original position complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separatly under respective item of this schedule,however minor items which are not catered in this schedule, the cost of the same shall be deemed to be included inthe unit rate of these items. (b) Minimum one technecian ( One Electrician and One Plumber) and one helper with all types of tools and plants/veh etc. should report to E&M yard for repair of geyser including taking down/ /fixing of same. (c) Repair works will be carried out at workshop E&M yard. (d) Repair works of geyser should completed and refixed the same with in 12 hrs after receipt of complaint slip. If the contactor found fail to do complaint, an amount of Rs. 500 for each complaint will be deduct from the RAR bill.
Supply and fixing in replacement of geyser Vertical type of capacity 25 ltrs, Single phase, 240 Volts, Colour Grey with auto cutoff and ajustable temparture. Make : Havells/ Crompton/Bajaj (old meter to be deposit in MES store nd takenon ledger charge)
Supply & fixing heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type round) ISI marked complete all as specified and directed make - Theta /Daspass.
Supply & fixing heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type triangular) ISI marked complete all as specified and directed make - Theta /Daspass.
Supply & fixing Thermostat cone type, ISI marked make – Alcone or equivalent complete all as specified and directed.
Supply & fixing Thermostat switch coil type ISI marked make – Alcone or equivalent complete all as specified and directed.
Supply & fixing Brass Head Assembly having 8 to 9 holes suitable for 25 litres capacity geyser of make – Bajaj, Venus, Recold complete all as specified and directed.
Supply & fixing head assembly along with integrated heating element and thermostate ISI marke Make - Racold or equivalent
Supply & fixing Brass Safety plug ISI marked suitable for 25 / 35 / 50 litres capacity geysers complete all as specified and directed.
Supply & fixing mild steel spacer ring suitable for 25 / 35 / 50 litres capacity geyser complete all as specified and directed.
Supply & fixing round shaped rubber gasket having 8 to 9 holes, suitable for 25 / 35 / 50 liters capacity geyser complete all as specified and directed.
S&F Brass chromium plated connection 15mm, 450mm long with cromium plated adopter and washer at both ends complete all as specified and directed by Engr-in -charge.
S&F Brass chromium plated connection 15mm, 600mm long with cromium plated adopter and washer at both ends complete all as specified and directed by Engr-in -charge.
Supply & fixing Element holding clamps suitable for 25 / 35 / 50 Liters capacity geysers complete all as specified and directed.
S & F in repairs 450 mm long heavy duty PVC connection suitable for cold water supply with two Nos. PTMT nuts alongwith PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repairs 600 mm long heavy duty PVC connection suitable for cold water supply with two Nos. PTMT nuts alongwith PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
Supply & fixing Neon lamp (Red & Green) round / square in shape suitable for 25 / 35 / 50 liters capacity geysers complete all as specified and directed.
Supply and Fixing as in replacement ISI marked pressure release valve brass body suitable for 15 mm bore pipe line for cold water connection in storage geyser complete all as specified and directed.
M & L for repairing of inner copper tank / container of geyser by brazing not exceeding 4 cm in length complete all as specified and directed.
Supply and fixing of ISI marked inner shell made of stainless steel suitable for 25 Liters capacity geyser complete all as specified and directed.
Supply and fixing PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire all as specified and directed.
Supply and fix Plug Top 3 pin 15 Amps for storage geyser including removal of existing plug top complete all as specified and directed
Taking down carefully solar water heating system of capacity 200 to 600 liters per day of any make, dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of stainless steel tank thoroughly with washing compound or liquid solution, applying one coat of synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint, including replacement of unservicable element, tore glass tube and heat resistant insulating material as per existing sizes, type and watt and re-fixing of solar water heating system at its original position complete all as specified and directed.
Supply and fix GI pipe medium grade15 mm for making connection from storage geyser to bib tap complete including shaddles and screws all as specified.
Taking up or down (from wall/trenches/floor) existing 15mm GI steel tubing and connections, including cleaning for re-fixing or removal to store
Supply and fix Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedBib tap 15 mm for hot water supply point.
Supply and fix Angle valve cromium plated, screwed down high pressure, with or without lettered Hot and cold with long screwed shanks and fly-nuts, screwed for iron pipe.
Supply and fix pressure release valve suitable for 25 mm dia pipe for solar hot water supply made out of gun metal complete all as specified and directed.
Supply and fix Solar Water heating element 3 KW suitable for hot water storage tank including disconnection existing element and making new electric connection complete all as specified and directed.
Rotational moulded polyethylene PVC water storage tanks of capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in replacment in position all as specified in SSR part-I complete, all as specified and directed at site.
Taking out Window/Split type Air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner checking of blower motor, electrical connection and re-fixing the same on its original position and testing complete up to satisfaction of Engineer-in-Charge. (If any spare is required to replaced the same to be measured and paid separately under supply only item)
Removing defective window/Split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site all as directed by Engineer-in-Charge. (All spares compressor, fan motor, relay, capacitor, over load, shall be measured and paid separately under supply only item)
Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed by Engineer-in-Charge. Note:- i) Rotary compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
SUPPLY ONLY ITEM Note : i) The items for fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New Rotary type compressor of Capcity 1.5 TR MAKE : Kirloskar/Tecumesh/Carrier / Hitachi / Blue Star /LG/ samsung as per recommanded by manufacture or equivalent
New Rotary type compressor of Capcity 2.0 TR MAKE : Kirloskar/Carrier / Hitachi / Blue Star / LG / samsung/ Highly as per recommanded by manufacture or equivalent
FHP motor of capacity 1/5 to 1/18 single phase 920/1440 RPM with capacitor suitable for window/split type AC of any make & capacity. Make : AUE or as per recommanded by manufacture or equivalent
Starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD Make: Keltronor / Siemens or as per recommanded by manufacture or equivalent
Running Capacitor 45/50 MFD or 45+6 / 50+6 MFD Make : EPCOS / Siemens or as per recommanded by manufacture or equivalent
Running Capacitor 36 MFD / / 36+6 MFD Make : EPCOS or as per recommanded by manufacture or equivalent.
Starting relay suitable for 1.0/ 1.5 / 2.0 TR Compressor Make: HI-tech/Classic or as per recommanded by manufacture or equivalent
Air filter Nylon/plastic type suitable for window / Split type A/C .
Thermostat suitable for window / Split type A/C Make : INDFOSS/Godrej or as per recommanded by manufacture or equivalent
Front grill for window type AC of any model all as required at site and as directed (Make: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier/samsug/voltas)
Condenser/cooling fan blade suitable for window type AC of any make & capacity
Blower unit only suitable for window AC of any capacity & make
PCB card along with remot suitable for window/split type AC of any capacity & make
Digital circuit plate along with remot suitable for windoe/split type AC of any capacity & make
Blower Motor both end coupling complete for Indoor split AC 1.5 / 2.0 TR of any make
Indoor door unit complete with cooling coil & remot suitable for split type AC of capacity 1.5 TR
Indoor door unit complete with cooling coil & remot suitable for split type AC of capacity 2.0 TR
Outdoor door unit complete with condeser coil & FHP motor suitable for split type AC of capacity 1.5 TR
Outdoor door unit complete with condeser coil & FHP motor suitable for split type AC of capacity 2.0 TR
Copper liquid line filter two way / One way.
Contactor suitable for outdoor unit of split type AC of any capacity & make
PVC rounded 3 core, 4.0 Sqmm copper work shop cable.
New Reciprocating type compressor of Capacity 1.5/2.0 TR MAKE : Kirloskar/Tecumesh/Carrier / Hitachi / Blue Star /LG/ samsung as per recommanded by manufacture or equivalent
Copper pipe suitable for connection of window / split AC of size 1/4'' or 3/8'' (inch) with insulation slleve Foam Heat insulation complete
Copper pipe suitable for connection of window / split AC of size 1/2'' or 5/8'' (inch) with insulation slleve Foam Heat insulation complete
Supply & replacement wiring loom complete suitable for window / split type air conditioner complete with all as specified.
Supply, Installation, commissioning and fixing of reverse cycle valve any make suitable for window/Split type AC 1.5/2.0 Ton capacity including required copper pipe and two way switch complete all as specified and directed NOTE:- Gas charging if required shall be paid separately under respective item of BOQ..
M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920/1440 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as speified and directed.
Cutting damaged tray from window type air conditioners and replacing with existing shape and size including all necessary work such as welding, nut, bolts, drilling etc suitable for 1.5 / 2.0 TR Air conditioners complete.
M & L for gas charging M/R-12 / M/R-22 / R-134a / R410a / R32 to the following appliances including removal of old fitter, copper tubing / capillary and replacement of new filter, capillary, short piece of copper tubing of equipment and leakage testing of the same on full load after re-installation of the same at site complete all as specified and directed: -
Window type air conditioner 1.5 Ton capacity of any make.
Split type air conditioner 1.5 Ton AC capacity of any make.
Refrigerator Capacity 300 to 320 Ltr of any make
Water cooler 40/80 Ltr capacity
Water cooler 150 Ltr capacity
Material and labour for Minor denting and one coat spray paint of window type Air conditioners mentioned item No.1 above complete internally and externally with suitable super enameled synthetic enameled paint of required colour complete all as directed by the Engineer-in-Charge.
Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified.
Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor as directed.
SUPPLY ONLY ITEM
Main relay 24 Volts, 25 Amps.
Main Control circuit (PCB)
Output terminal 32 Amps
Replacement of Censor Transformer
Voltmeter anolog / Digital type as per sample of any make & capacity
Time delay 2-3 minute over low voltage 180 volts AC and high voltage 260 Volt AC.
Taking out old burnt winding work and re-winded with super enameled copper winding wire (existing size) for 5 KVA voltage stabilizers including all necessary insulating material and testing complete.
All as per item No. 234 above but capacity of voltage stabilizer 4 KVA/3KVA.
All as per item No. 234 above but capacity of voltage stabilizer 2 KVA / 1KVA.
Painting of voltage stabilizers with one coat of synthetic enameled paint (existing colour) after proper cleaning and scraping old painted surfaces and write GE (MES) Roorkee on voltage stabilizers in block letters with white paint complete as directed.
S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB SP of size 20/32 Amp 'c' series, single phase including connecting complete all as specified.
Transporting refrigerator of any make and capacity from MES Store Yard to contactor’s workshop for carrying out necessary repair as mentioned in respective items including back to MES Store Yard after repair and testing complete.
Removing unserviceable burnt sealed compressor from refrigerator and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
SUPPLY ONLY ITEM Note : i) The items for fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New sealed compressor of size 1/6 HP to 1/8HP suitable for refrigerator / Deep freezer of capacity 165 Ltr to 310 Ltr Make: Kirloskar / Tecumesh / Whirl pool / LG / Blue star / Hitachi or as per recommanded by manufacture or equivalent
Relay suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or as per recommanded by manufacture or equivalent
Over load suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr Make : INDFOSS/Godrej or as per recommanded by manufacture or equivalent
Thermostate suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or as per recommanded by manufacture or equivalent
PVC freezer door suitable for refrigerator any make & capacity.
Chiller tray of any make and capacity suitable for refrigerator.
Vegitable tray suitable for refrigirator of any make & capacity
Shelves suitable for refrigirator of any make & capacity
Magnetic rubber door gasket suitable for refrigerator of any make & capacity.
PVC insulated and PVC sheathes rounded 3 core, 2.5 Sqmm copper work shop cable.
Freezer Box / Chiller Assembly complete with coil and chamber of any make and capacity suitable for refrigerator.
Screw/Pin type bulb suitable for refrigerator of any make & capacity.
Taking down/out water cooler of any Make and capacity from various locations transporting to contractor’s workshop for carrying out repair as mentioned in respective items of Schedule ‘A’ including transporting back after repair fixing at site re-connecting electrical & water connection & its re-testing on load all as specified & directed.
Removing unserviceable burnt sealed unit compressor from water coolers and fixing only sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed by Engineer-in-Charge. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
Removing un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/5 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete up to satisfaction of Engineer-in-Charge.
SUPPLY ONLY ITEM Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New sealed unit compressor suitable for water cooler 40 / 80 Ltr Make: Kirloskar/Tecumsch/ Whirl pool / kelvinator / Hitachi / Electrolux or equivelant as approved by GE.
Relay & OLP suitable for water cooler of any make & capacity Make: HI-tech/Classic or as per recommanded by manufacture or equivalent as approved by GE.
Thermostat switch suitable for water cooler any make & capacity Make : - Indfos or as per recommanded by manufacture or equivalent as approved by GE.
Push taps chromium brass body inner/outer thread suitable for water cooler capacity up to 40/80 Ltr (as per sample)
Fan motor blade size 12" sweep suitable for FHP motor of water cooler
PVC flexible pipe transparent 15mm/20mm dia dia (as per sample)
PVC float valve 15 / 20 mm dia with rod & ball. Make: Prayag or equivalent as approved by GE.
Running Capacitor 4 MFD Make : EPCOS or as per recommanded by manufacture or equivalent as approved by GE.
3 pin plug top one way 5 Amp, 240V
3 pin plug top 15 Amp, 240V
Submersible water lifting pump of capacity 18 watt suitable for 1.25 M head 230 V AC.
Kit fan motor 1/6 HP suitable 450 mm Sweep 1350 / 1400 RPM. Make : Everest / Summer Cool / Khatian
Industrial type three pin metal clade socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
Industrial type three pin metal clade plug top of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
Supply only Industrial type Heat Pillar tower type suitable for winter heating of capacity 2 x 750 watt, stainless steel body oscillating quartz type of size 270mm x 210mm x 900mm complete. Make : BEXCO or Gopi or Khaitan
Supply & Fix condenser coil complete with copper tube and aluminium fins suitable for water cooler of any make and capacity complete.
Material and labour for cutting worn out bottom and sheet base frame including MS legs from water cooler of any make and capacity and fixing the same with PGI sheet 16 SWG of existing size and new angle iron base from (angle size iron 50 x 50mm x 6mm) and legs including necessary gas welding and providing nut/bolts etc complete all as specified.
Material and labour for minor denting and painting of water cooler complete by spray painting super enameled with one coat of enamel paint after proper scraping of old painted surface complete all as specification.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed,
M&L for painting of desert cooler’s external body, fan & pump with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as directed.
M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size.
M&L for rewinding of stator of exhaust fan/kit fan 18” sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour all as specified
M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 Cm or as per sample with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 amp Piano type switch and indicator etc complete all as specified.
Supply and install desert cooler electric driven (single phase) 230 Volt 50 Hz having steel fabricated cabinet of size 26 inch x 17 inch x 50 inch with 22 SWG PGI sheet water storage tank including round chrome double diversion grills, PVC fills Honeypad, Three speed copper wounded Motor 1400 RPM with aluminium blade including submersible water lifting pump suitable to lift water upto 6 feet including Speed regulator,electrical cord three core and plug top 5 Amp complete in respect with audjustable iron wheel stand all as specified.
SHRI RAM ENTERPRISES
M/S ROORKEE ENGINEERING
PARADISE INFRA POWER COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .