Loading…
Loading…
Tender Value
₹6.6 Cr
EMD Value
₹13.3 L
Closing Date
29 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The balance sheet and all other financial documents attested/certified by the Chartered Accountant (CA) to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN (Unique Document Identification Number), failing which the offer shall be considered as incomplete and will be summarily rejected without any further reference. Ref: GM (ENGG) HJP letter No- ECR-HQ0ENGG(CONT)0009/2025Dtd 18.11.2025)
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited 1) Three similar works each costing not less than the amount equal to 30% of advertised value of tender,or 2)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or 3)One similar work costing not less than the amount equal to 60% of advertised value of the tender. In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity
Similar Nature of work-Any work involving outdoor or indoor signaling work. Signaling Work-All work which directly related to the interlocking of the Core Signaling System. O R Any MACLS work involving outdoor & indoor work or alteration in existing indoor/outdoor signaling system OR Any work involving outdoor/indoor signaling works including MACLS/EI/PI/RRI/IBS/IBH/LC Gate/DAC/ELD and ELD for signaling cable, Quad Cable, Fuse Auto Change over System etc. Ref: (ECR/HJP letter No- ECR-HQ0SnT(SNW)/1/2020 (Computer no- 81849) Dtd 14.10.2025
30 conditions · 8 needing a document upload
The tenderer whether sole proprietor, a company or a partnership firm / joint venture (JV) / registered society / registered trust etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person specifically authorizing him/them to submit the tender, sign the agreement, receive money, co-ordinate measurements through contractor's authorized engineer, witness measurements, sign measurement books, compromise, settle, relinquish any claim(s) preferred by the firm andThe tenderer whether sole proprietor, a company or a partnership firm / joint venture (JV) / registered society / registered trust etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person specifically authorizing him/them to submit the tender, sign the agreement, receive money, co-ordinate measurements through contractor's authorized engineer, witness measurements, sign measurement books, compromise, settle, relinquish any claim(s) preferred by the firm and sign "No Claim Certificate" and refer all or any disputes to arbitration. sign "No Claim Certificate" and refer all or any disputes to arbitration.
The Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond in favour of FA & CAO /ECR/HJP shall be as per Annexure VIA and shall be valid for a period of 90 days beyond the bid validity period. { Advance correction Slip No.- 11 to Indian Railways Standard Conditions of Contract, April.2022 Authority: Railway Board letter No- 2022/CE-I/CT/GCC-2022/POLICY/Pt.I(E- 3320424 New Delhi Dtd. 13.03.2026}
The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (i.e. excluding the last date of submission of bids) (As Per Rly. Bds Letter No. 2022/CE- I/CT/GCC-2022/Policy dated 20.10.203, Advance Correction Slip No. 5 & Railway Board letter No- 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I(E-3320424 New Delhi Dtd. 13.03.2026 Advance Correction Slip No. 11).
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / company / Joint Venture (JV) / Registered Society / Registered Trust etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (ii) In case tenderer is other than sole proprietorship firm, following documents shall be submitted by the tenderer: (a) Partnership Firm: The tenderer shall submit (i) a notarized copy of Partnership Deed or a copy of partnership deed registered with the registrar. (ii) a copy of Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. (b) Joint Venture (JV): The tenderer shall submit documents as mentioned in Clause 17 of the Tender Form (Second Sheet). (c) Company registered under Companies Act-2013: The tenderer shall submit (i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (d) LLP (Limited Liability Partnership) Firm: If the tender is submitted on behalf of a LLP Firm registered under LLP Act-2008, the tenderer shall submit alongwith the tender- (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (e) Registered Society & Registered Trust: The tenderer shall submit (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender. (iv) After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society etc. shall be neither asked nor considered, if submitted. (v) A tender from JV / Partnership firm etc. shall be considered only where permissible as per the tender conditions. (vi) The Railway will not be bound by any change in the composition of the firm made subsequent to the submission of tender. Railway may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor
The successful bidder shall have to submit a Performance Guarantee (PG) amounting to 5% of the original contract value and Additional Performance Guarantee of 5% if applicable as per clause 16(a)(h) of GCC-2022 which is attached as advance correction Slips of GCC-2022 separately in NIT.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Tenderers are required to scrutinize carefully all clauses appearing in the Tender documents before uploading their bid
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under
In case of any information submitted by tenderer is found to be false forged or incorrect after the award of contract, the contract shall be terminated. Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of up to two years
Railways reserves its right to either cancel the tender or reject any or all the tenders without assigning any reasons thereof
General Conditions of the Contract (GCC), April 2022 with latest amendment/ correction slips is applicable and final authority for this contract in case of any conflict or confusion. The contract shall be governed by the provision of Indian Railways Standard General Conditions of Contract-2022 (Latest) with correction slips up to the date of uploading of tender.
The firm must entry of details of numbers of engaged labours ( skilled or unskilled) , ESIC & PF deduction if applicable) , must be updated on IR- Shramik Kalyan portal at the time of execution of work. Without uploading of these documents running bill of concerned period will not be processed.
Firm must submit details of Graduate/diploma engineers or equivalent employed by the firm against this work with relevant certificate within two weeks of issue of LOA/before making of agreement Other wise any bill will not be process and LD will be imposed as described in tender Document
No payment will be initiated till all the conditions regarding Payment of Wages act & Minimum Wages act in terms of clause 54 and 55 of Indian Railways General Condition of Contract. It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & real payments made thereof after each wage period on Shramik Kalyan portal.
Item wise inspection clause has been given in the schedule . However, modification may be done at the time of issue of LOA
The firm must follow the instructions regarding precaution taken during trenching/digging work which is mentioned in the JPO issued dated 21.05.2024. The JPO has been attached in Tender document.
It is mandatory to followed provisions under Make in India policy 2017 issued by Govt. of India, as amended from time to time
If the firm submit Bank guarantee against either Bid security at the time of bid or PG after award of work , they should submit Swift copy of AFMS of the concerned BG duly issued from the concerned bank , otherwise the BG will not be received. Authority: Railway Bd Letter No- 2025/F(X)-II/10/14 New Delhi- Dtd. 17.10.2025.
After inspection, supply of any active materials will not be received by consignee without respective OEMs warranty certificate
The firm has to submit RECEIPT CERTIFICATE having all the information for each supplied items in S&T/store in the prescribed Performa -Z attached at para No- 40 ( Payment clause ) in the tender document. Without submission eMB will not be initiated
Rehabilitation and reliability improvement of S&T gears in Danapur Division.
DNRSandTSig2026-4
DNRSandTSig2026-4
Open
Works - General
12 Months
Patna, Bihar
₹0
₹13.3 L
29 May 2026
5 May 2026
12 May 2026
243 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,62,86,856.98 | ||
| — | — | — | Above/ 70300.00 Below/P | ||
| Excavation, trenching, earth work and reinstatement of track while track crossisng. | — | 500.00 | — | — | |
| — | — | — | Above/ 200870.00 Below/P | ||
| Reinstatement of platform and repairing to orginal state after cable laying work. | — | 500.00 | — | — | |
| — | — | — | Above/ 150652.50 Below/P | ||
| Repair of PUCCA roads to original state in level x-ing area after cable laying work. | — | 250.00 | — | — | |
| — | — | — | Above/ 1165049.00 Below/P | ||
| Laying cable of different sizes as per cable route plan approved by Railway-2 core to 12 core signalling cable. | — | 100.00 | — | — | |
| — | — | — | Above/ 361566.90 Below/P | ||
| Laying cable of different sizes as per cable route plan approved by Railway.-Telecom Cable 5 Prs./10 Prs./Quad | — | 30.00 | — | — | |
| — | — | — | Above/ 672915.00 Below/P | ||
| Supply of G.I. Pipe with threaded collars of 100 mm nominal bore specn no. IS1239 medium grade.Inspection-RITES | — | 500.00 | — | — | |
| — | — | — | Above/ 30130.00 Below/P | ||
| Fixing (Execution) with remaining miscelleneous materials | — | 500.00 | — | — | |
| — | — | — | Above/ 287244.90 Below/P | ||
| Supply of CLS Post 4.5 mtr. and Ladder 4.5 Mtr. With bases as per RDSO DRG.No.SA.5533/ADV and RDSO Spec. No.S6-81. Inspection-Consignee | — | 10.00 | — | — | |
| — | — | — | Above/ 972213.60 Below/P | ||
| Supply of CLS Post 3.5 mtr. and Ladder 4.5 Mtr. With bases as per RDSO DRG.No.SA.5533/ADV and RDSO Spec. No.S6-81. Inspection-RITES | — | 40.00 | — | — | |
| — | — | — | Above/ 369601.60 Below/P | ||
| Casting,concreting and curing of foundation for Main signal and as per DRG.No.SGW/MGS/S1/91 including cost of all materials required for casting and concreting and provision of holding down bolts & nuts. | — | 40.00 | — | — | |
| — | — | — | Above/ 1714329.60 Below/P | ||
| Supply of full size location box as per design of GKP signal workshop.Inspection-RITES | — | 60.00 | — | — | |
| — | — | — | Above/ 471179.60 Below/P | ||
| Supply of half size location box as per design of GKP signal workshop.Inspection- Consignee | — | 20.00 | — | — | |
| — | — | — | Above/ 143142.60 Below/P | ||
| Supply of quarter size location box as per design of GKP signal workshop.Inspection- Consignee | — | 10.00 | — | — | |
| — | — | — | Above/ 16069.50 Below/P | ||
| Supply of Bakelite Strip/Sheet of Size (950 x 75 x 12) mm. For fixing 30Nos. ARA terminals/ Fuse base terminals/Fuse base.Inspection-Consignee | — | 25.00 | — | — | |
| — | — | — | Above/ 435888.60 Below/P | ||
| Casting,Concreting and Curing of foundation and erection for full apparatus case (GKP-type) as per DRG No.SGW/MGS/L1/91 includong cost of all materials required for fixing holding down bolts, casting, concreting and fixing of "E" type lock. Note- i)The contractor will provide holding down bolts. ii)Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | — | 70.00 | — | — | |
| — | — | — | Above/ 102443.80 Below/P | ||
| Casting,Concreting and Curing of foundation and erection for half apparatus case (GKP-type)as per DRG No.SGW/MGS/L1/91 includong cost of all materials required for fixing holding down bolts, casting, concreting and fixing of "E" type lock. Note- i)The contractor will provide holding down bolts. ii)Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | — | 20.00 | — | — | |
| — | — | — | Above/ 40174.10 Below/P | ||
| Casting,Concreting and Curing of foundation and erection for quarter apparatus case (GKP-type)as per DRG No.SGW/MGS/L1/91 includong cost of all materials required for fixing holding down bolts, casting, concreting and fixing of "E" type lock. Note- i)The contractor will provide holding down bolts. ii)Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | — | 10.00 | — | — | |
| — | — | — | Above/ 349514.40 Below/P | ||
| Fixing,wiring of terminal strips,bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for full appratus case. (All materials except transformers, relay, terminal strips, bakelite strip and fuses with base to be spplied by the contractor.). | — | 60.00 | — | — | |
| — | — | — | Above/ 34147.90 Below/P | ||
| Fixing, wiring of terminal strips, bakelite strip, transformers, relays,fuses with base and supply and fixing of shelves for half apparatus case (All materials except transformers, relay, terminal strips, bakelite strip and fuses with base to be spplied by the contractor.). | — | 10.00 | — | — | |
| — | — | — | Above/ 15667.90 Below/P | ||
| Fixing, wiring of terminal strips, bakelite strip, transformers, relays,fuses with base and supply and fixing of shelves for quarter apparatus case (All materials except transformers, relay, terminal strips, bakelite strip and fuses with base to be spplied by the contractor.). | — | 10.00 | — | — | |
| — | — | — | Above/ 43874.00 Below/P | ||
| "Filling earth around location box/signal post for a width of 0.5 m on all sides, upto a level of 150 mm below the foundation top. This work includes consolidation of earth by watering." | — | 200.00 | — | — | |
| — | — | — | Above/ 160913.00 Below/P | ||
| "Supply of E-type lock without key,spec.no.IRS-S-30,Drg. no. S-3376/M key-S-3377/M. Individual number of miniature E locks and Normal size of locks required at site to be decided by the site engineer as per site requirement.-Inspection-RDSO" | — | 100.00 | — | — | |
| — | — | — | Above/ 12081.00 Below/P | ||
| Key for E type lock supplied above -Inspection-RDSO | — | 50.00 | — | — | |
| — | — | — | Above/ 259036.00 Below/P | ||
| Miniature lock.-Inspection-RDSO | — | 200.00 | — | — | |
| — | — | — | Above/ 127677.00 Below/P | ||
| Supply of 8 SWG soft drawn GI wire bond pieces (1320x4)mm. Resistance upto 19.5 OHM/MT.To IS-280 & IS - 23.Inspection-Consignee | — | 7950.00 | — | — | |
| — | — | — | Above/ 180750.00 Below/P | ||
| Supply of channel Pin with single groove 7.2 mm Dia for 4 mm Dia bond wire to DRG.No.S-69/M & IRS Specn.IRS:S-S17.Inspection-Consignee | — | 25000.00 | — | — | |
| — | — | — | Above/ 462002.00 Below/P | ||
| Supply of point JB fitted with 18 Nos. 1 way ARA PBT terminal block conforming to IRS - S- 75/91 with 3 Nos. of 40mm Bore. GI pipe 600 mm long as per DRG No.SGW/MGS/PT4/91 fixed on hard wood plank with U-channel (75 x 40 x 1500) mm for fixing. Inspection-(Point JB-Consignee, ARA Terminal-RDSO) | — | 100.00 | — | — | |
| — | — | — | Above/ 902700.00 Below/P | ||
| Releasing of Decayed/ Damaged Location Boxes and Fixing of New Location Box in place of it including Repairing of Foundation Base and Plastering of thin Layers over Sand inside Location Boxes. For Full Location. | — | 150.00 | — | — | |
| — | — | — | Above/ 108560.00 Below/P | ||
| Releasing of Decayed/ Damaged Location Boxes and Fixing of New Location Box in place of it including Repairing of Foundation Base and Plastering of thin Layers over Sand inside Location Boxes. For Half Location. | — | 20.00 | — | — | |
| — | — | — | Above/ 25802.00 Below/P | ||
| Strengthening of foundations of signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, carrying out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. | — | 50.00 | — | — | |
| — | — | — | Above/ 65090.00 Below/P | ||
| Basement plastering of Full/Half location box. All the required men and materials are to be arranged by the contractor. | — | 250.00 | — | — | |
| — | — | — | Above/ 183336.00 Below/P | ||
| Replacement/Relocation of damaged/dilapidated/warn out TLJ Boxes, with new ones. This includes replacement of TLJ box, stump, pipes, termination of 2core cable and track leadwires, fixing of TLJ box duly digging the size of pit is 50cm X 50cm X50cm and keeping loose cable into the pit and closing the pit. TLJ boxes will be supplied by the railways as per the requirement Released dilapidated/ damaged TLJ boxes shall be transported and stacked at central location . This work has to be caried out under traffic conditions duly observing train movements. | — | 400.00 | — | — | |
| — | — | — | Above/ 29000.00 Below/P | ||
| Supply of slotted angle (40 x 40 x 2 mm) -Inspection-Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 68286.00 Below/P | ||
| Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils.Spec.no.IRS-S-76/89 material to be procured from RDSO approved firm only with performance guarantee-16/0.2 mm Inspection-RDSO | — | 50.00 | — | — | |
| — | — | — | Above/ 55856.80 Below/P | ||
| Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils.Spec.no.IRS-S-76/89 material to be procured from RDSO approved firm only with performance guarantee-3/0.750 Inspection-RDSO | — | 20.00 | — | — | |
| — | — | — | Above/ 53588.70 Below/P | ||
| Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils.Spec.no.IRS-S-76/89 material to be procured from RDSO approved firm only with performance guarantee- 7/0.75 mm Inspection-RDSO | — | 10.00 | — | — | |
| — | — | — | Above/ 1004352.00 Below/P | ||
| Supply of electrical key transmitter for crank handle interlocking arrangement siding control,LC Gate control.Inspection-RDSO | — | 100.00 | — | — | |
| — | — | — | Above/ 1558755.00 Below/P | ||
| Installation of electrical key transmitter on suitable bracket as per inspection of site engineer. ,wiring and testing of electrical key transmitter. | — | 100.00 | — | — | |
| — | — | — | Above/ 615076.80 Below/P | ||
| Supply of Thermoshrink jointing kit for 2T joints-6 quad-Inspection-RDSO | — | 120.00 | — | — | |
| — | — | — | Above/ 506210.40 Below/P | ||
| Installation of Thermoshrink jointing kit | — | 120.00 | — | — | |
| — | — | — | Above/ 102975.00 Below/P | ||
| Supply of PVC switch board cable, pair twisted, conductor of size 0.63 mm. dia Annealed copper conforming to IRS-TC-24/91 or ITD 1138-10 Pair-Inspection-Consignee | — | 2500.00 | — | — | |
| — | — | — | Above/ 219140.50 Below/P | ||
| Supply of cable termination box. Spec.no.IRS-TC-18-75 with locking arrangements and termination of derivation cable as per the technical supplements-20 Pairs-Inspection-Consignee | — | 50.00 | — | — | |
| — | — | — | Above/ 63943.25 Below/P | ||
| Supply of cable termination box. Spec.no.IRS-TC-18-75 with locking arrangements and termination of derivation cable as per the technical supplements-10 Pairs-Inspection-Consignee | — | 25.00 | — | — | |
| — | — | — | Above/ 209577.00 Below/P | ||
| Supply Consignee | — | 100.00 | — | — | |
| — | — | — | (latest)-1120:470-Inspection- | ||
| — | — | — | Above/ 209579.00 Below/P | ||
| Supply of VF transformer Spec.IRS-TC-22-76 or (latest)- 600:470-Inspection- Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 1319702.80 Below/P | ||
| Supply and installation of Optical fibre cable joint enclosure and making straight through joints for 24 fibre cable and testing. This includes splicing and making pits of size 1.2M dia x 1.2 M depth with top cover slab as per drawing 3.-Instpection-RITES | — | 40.00 | — | — | |
| — | — | — | Above/ 178465.60 Below/P | ||
| Supply of Shielded Twisted Pair Cable CAT -6 Make-D-Link or similar.-Inspection- Consignee | — | 20.00 | — | — | |
| — | — | — | Above/ 144163.50 Below/P | ||
| Supply of optical fibre cable splice closure (24 fibre) as per Tecanical Specification no.G/OFC- 02/01 mar'99 with latest amendments-Inspection-RDSO | — | 50.00 | — | — | |
| — | — | — | Above/ 257697.00 Below/P | ||
| Supply of adjustable track feed resistance disc type 30 ohm as per RDSO Drg no. SA- 20166/M/66 (adv) with latest amendments (with Phenolic moulded base)-Inspection-RDSO | — | 300.00 | — | — | |
| — | — | — | Above/ 89107.70 Below/P | ||
| Supply of Battery Charger - Track Feed Up to 10 Amp, Spec. No.IRS:S-89/93 (Amd.-2) or Latest.--Inspection-RDSO | — | 10.00 | — | — | |
| — | — | — | Above/ 124714.50 Below/P | ||
| Supply of FRP type TLJB (track lead junction box) fitted with 4-way ARA terminals with Angle iron of Size (1500 x 50 x 50) mm & 6mm thick to hold the junction box and for fixing cable entry pipe (40 x 500) mm. as per Spec. No.- RDSO/SPN/151/1997 or latest.-Inspection(TLJB- Consignee,ARA Terminal-RDSO) | — | 150.00 | — | — | |
| — | — | — | Above/ 25654.10 Below/P | ||
| "Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of nonmetallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 3 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23003/A/M/ADV.ALT-8 and per spec. no.RDSO/SPN/194/2006 (VER-1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water.- Execution" | — | 10.00 | — | — | |
| — | — | — | Above/ 389365.10 Below/P | ||
| "Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of nonmetallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 3 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23003/A/M/ADV.ALT-8 and per spec. no.RDSO/SPN/194/2006 (VER-1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water.- Supply" | — | 10.00 | — | — | |
| — | — | — | Above/ 72489.60 Below/P | ||
| "Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of nonmetallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 2 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23003/A/M/ADV.ALT-8 and per spec. no.RDSO/SPN/194/2006 (VER-1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water.- Execution" | — | 30.00 | — | — | |
| — | — | — | Above/ 1155766.20 Below/P | ||
| "Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of nonmetallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 2 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23003/A/M/ADV.ALT-8 and per spec. no.RDSO/SPN/194/2006 (VER-1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water.- Supply" | — | 30.00 | — | — | |
| — | — | — | Above/ 846640.00 Below/P | ||
| Supply of Disconnect type Terminal,screwless, 2 IN 2 OUT (as per spec. no. RDSO/SPN/189/2004 or latest) along with all accessories including separators for fixing on Cable Termination Rack/Location boxes for Cable Termination Purpose.-Inspection-RDSO | — | 8000.00 | — | — | |
| — | — | — | Above/ 11520.00 Below/P | ||
| Fixing installation of disconnect terminal (Wago or similar) onrelay rack/ctr/location with steel carrier rail. | — | 8000.00 | — | — | |
| — | — | — | Above/ 3559625.00 Below/P | ||
| Excavation of Trench in all kinds of soil and refilling of trenches (1.0 Mtr Depth, 300 mm Width)-Without bricks | — | 50.00 | — | — | |
| — | — | — | Above/ 10541840.00 Below/P | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring for placing of 110 MM inner dia HDPE/DWC pipes for crossing of S&T cable together at Bridges/ Culverts/Track/ pucca road Crossing, Boring trench shall be minimum 3 Mtr below the river bed and 1 Mtr below the Track/Road /Pucca Road crossing area. This includes supply of HDPE/DWC pipes and accessories, cost of fuels & all other items which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer.- (a) Boring upto length 150 Mtrs. Inspection of HDPE Pipe-Consignee | — | 8000.00 | — | — | |
| — | — | — | Above/ 1767303.00 Below/P | ||
| Providing and laying in position cement concrete of 1:3:6 (1 cement : 3 sand : 6 gradded stone aggregate 20 mm nominal size) including cement for laying of cable in Duct as per instruction of site engineer. Payment will be as per actual work in Cum. | — | 300.00 | — | — | |
| — | — | — | Above/ 179760.00 Below/P | ||
| Excavation of trench less trench /manual boaring (size upto 110 MM) upto a depth of minimum 1.0 Meter along with dia HDPE/ DWC pipes and its accessories, all other items which will be required for laying of cable through HDPE/DWC pipes as per requirement at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 31408.00 Below/P | ||
| Supply of drill bit of size 9/32""(7.2/7.14mm) twist drill morseshank suitable for making holes in the rails for TWS. Contractor should get the approval of sample from railway Engineer before supply. Note- Compatible for installation of 220mm point m/c for Thick Web Switch.- Inspection-Consignee | — | 200.00 | — | — | |
| — | — | — | Above/ 305374.00 Below/P | ||
| Supply of Annular Cutter 22*55.-Inspection-Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 160115.00 Below/P | ||
| Supply of Annular Cutter 22*30.-Inspection-Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 69360.00 Below/P | ||
| Supply of Condenser 20000 MF/ 50V.-Inspection-Consignee | — | 500.00 | — | — | |
| — | — | — | Above/ 24655.00 Below/P | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for trackcircuit rail bonding. As per IRS Specification S:13@ 45>[email protected] | — | 250.00 | — | — | |
| — | — | — | Above/ 4568010.00 Below/P | ||
| Supply of 32Ft long steel octagonal Booms for ELB set (02 Nos.) as per RDSO/SPN/208/2012 (Ver 2.0) with latest amndt Ins:-RDSO (Set means two nos. 32 ft octagonal boom)-Inspection-RDSO | — | 100.00 | — | — | |
| — | — | — | Above/ 256546.20 Below/P | ||
| Supply of PMDC MOTOR 110V AC, 90 WATT suitable for ELB.-Inspection-Consignee | — | 15.00 | — | — | |
| — | — | — | Above/ 85515.40 Below/P | ||
| Supply of PMDC MOTOR 110V DC, 90 WATT suitable for ELB-Inspection-Consignee | — | 5.00 | — | — | |
| — | — | — | Above/ 95131.20 Below/P | ||
| Supply of BOOM LOCK PMDC MOTOR,110V AC/40W suitable for ELB.-Inspection- Consignee | — | 30.00 | — | — | |
| — | — | — | Above/ 31710.40 Below/P | ||
| Supply of BOOM LOCK PMDC MOTOR,110V DC/40W suitable for ELB.-Inspection- Consignee | — | 10.00 | — | — | |
| — | — | — | Above/ 158000.00 Below/P | ||
| Provision of Boom welding at LC Gate. | — | 200.00 | — | — | |
| — | — | — | Above/ 185730.80 Below/P | ||
| LC gate road user warning alarm hooter along with accessaries.Inspection-Consignee | — | 10.00 | — | — | |
| — | — | — | Above/ 1823875.60 Below/P | ||
| Supply, Installation, testing & commissioning of MAPLE 4C/Fabio of equivalent 1U, 19 Inch rack mountable device consisting of Min. four E1 ports and three slots and one populated with 2W/4W E&M supporting upto eight interfaces, Balance two slots empty, units shall support both 230V AC/48V DC power supply including 50 pin cable one No. for supporting both 2W/4W E & W, AC adopter one number. It includes supply of 19" rack. Make: TEAM ENGG, FABIO, Mro-tek, Real time, Cygnus, Cisco or similar.-Inspection-RITES | — | 20.00 | — | — | |
| — | — | — | Above/ 574947.50 Below/P | ||
| Supply and installation of portable CO2 fire extinguisher (4.5Kg).- Inspection-RITES | — | 50.00 | — | — | |
| — | — | — | Above/ 180000.00 Below/P | ||
| Supply of portable fire ball of reputed make.-Inspection-Consignee | — | 150.00 | — | — | |
| — | — | — | Above/ 472320.00 Below/P | ||
| Exposing of cable in the vicinity of track by excavating soil & ballast and then relaying and back filling to it in original state at one particular place. | — | 1200.00 | — | — | |
| — | — | — | Above/ 247000.00 Below/P | ||
| Digging out of TLJB & its tail cable and back filling along with inserting it back. Also, determinating & its termination of wiring. This work is for one TLJB. | — | 500.00 | — | — | |
| — | — | — | Above/ 71250.00 Below/P | ||
| Digging out of Point JB & its cable after opening of wiring from ARA terminals & its reconnection of conductor in point JB and reinsertion along with back filling of point JB to it in original state. This work is for one point JB. | — | 100.00 | — | — | |
| — | — | — | Above/ 2700000.00 Below/P | ||
| Alteration & Modification in design of Existing EI system, Existing Application Logic Programme & interface circuit diagram to suit Modified SIP and related modified work in EI system. Alteration in wiring, interconnecting cables, connectors, terminals, mounting arrangements, fixures & accessories to make EI system alteration functional along with installation of additional hardware, testing & commissioning of Siemens make Electronic Interlocking system. | — | 1.00 | — | — | |
| — | — | — | Above/ 342757.70 Below/P | ||
| Painting and numbering of all equipments such as Signals, Shunt Signals/Calling-On Signals,Electric Point machines,Track circuit equipments,Apparatus cases, Rod runs and its accessories, Junction boxes, Track lead junction boxes including existing gears. Painting shall consist of "2 coats" of "primer" and "3 coats" of "final paint". Note:- Paint should be ISI marked.-Upto 8 lines stations. Paint Inspection-Consignee | — | 10.00 | — | — | |
| — | — | — | Above/ 2057745.00 Below/P | ||
| Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary .Primer and paints both Asian paint make are to be supplied by the contractor.Numbering is to be as per practice of the ECR and directives of the site Engineer.Location boxes inside and outsided surfaces with Aluminium paint-Single case. Paint Inspection-Consignee | — | 1500.00 | — | — | |
| — | — | — | Above/ 444292.00 Below/P | ||
| Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary .Primer and paints both Asian paint make are to be supplied by the contractor.Numbering is to be as per practice of the ECR and directives of the site Engineer.Location boxes inside and outsided surfaces with Aluminium paint.-Main signal post, signal unit, surface base and coplete fitting as per ECRly practice.Paint Inspection-Consignee | — | 400.00 | — | — | |
| — | — | — | Above/ 37186.00 Below/P | ||
| Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary .Primer and paints both Asian paint make are to be supplied by the contractor.Numbering is to be as per practice of the ECR and directives of the site Engineer.Location boxes inside and outsided surfaces with Aluminium paint.-Point machine with ground connections & JB complete (Point machine with black enamel only outside and ground connection with red oxide)Paint Inspection- Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 430487.30 Below/P | ||
| Supply, installation, Testing & commissioning of Data Logger System for Rly. S&T. Installation as per RDSO Specification no. IRS:S:99/2006 with latest amendment with 1024 Digital input and 32 Analog inputs along with PC & Multi Function Colour Printer.-Inspection-RDSO supply portion | — | 1.00 | — | — | |
| — | — | — | Above/ 61403.66 Below/P | ||
| Supply, installation, Testing & commissioning of internal Dual card RS232 to EI convertor suitable for datalogger for item no.21(a).-Inspection-Consignee supply portion | — | 1.00 | — | — | |
| — | — | — | Above/ 23063.26 Below/P | ||
| Supply , Installation, Testing & Commissioning of External E1 to serial converter- Inspection-Consignee supply portion | — | 1.00 | — | — | |
| — | — | — | Above/ 857488.06 Below/P | ||
| Supply and installation of Early streamer Emission lighting conductor (ESELC) fullyautonomous having lower series of energy collecting electrodes upper series of spark - generating electrodes, as in built micro controller for detection of lightning down ward leader and releasing upward ladder at that very precise moment to ensure nuisance free, fail safe ,real need based operation any and every time ,sealed in a stainless -steel housing fixed at the center of its central rod which has full electrical connectivity direct up to earth point ,gain in triggering time of 25 micro sec giving 75 meters radious, level Ihigh protection, real life & high voltage laboratory tested, CPRI tested.-Inspection-supply RDSO | — | 2.00 | — | — | |
| — | — | — | Above/ 15928.10 Below/P | ||
| "Supply and erection of a mast/high mast suitable for ESE Technology based lighting protection installation ,mechanically robust good corrosion and fire resistance 5 meter ( including 2 meter FRP) long GI/MS painted, along with guying kit foundation and other accessories erquird for installation of the mast.-Inspection- supply Consignee " | — | 2.00 | — | — | |
| — | — | — | Above/ 73445.00 Below/P | ||
| "Supply and laying of 70 sq. mm. PVC insulated flexible tinned electrolytic copper down conductor placed in a metalic/PVC protectivecovering wherever exposed to human intervention including saddles and all accessories etc. as required.-Inspection- supply Consignee " | — | 50.00 | — | — | |
| — | — | — | Above/ 124150.00 Below/P | ||
| Supply & installation of resettable 6 dight LCD lighting strike recorder /transient event counter with 10 year long life lithum battery in an all whether proff box of IP67 grade protection along with clamps etc. as requird.-Inspection- supply Consignee | — | 2.00 | — | — | |
| — | — | — | Above/ 97869.52 Below/P | ||
| Supply and fixing of Equipotential Earth Bonding unit between electrical & equipment earthing in a explosion proof IP68 enclosoure with inspection chember for equipotential bonding during a surge.-Inspection- supply Consignee | — | 2.00 | — | — | |
| — | — | — | Above/ 37607.75 Below/P | ||
| Supply and laying of 25 x 3 mm. pure electrolytic copper tape through suitable 'class B' G.I pipe for loop earthing and bonding as per site requirement .-Inspection- supply Consignee | — | 25.00 | — | — | |
| — | — | — | Above/ 66260.00 Below/P | ||
| Suppy of 10 sq mm multi strand single core PVC insulated copper cable as per IS;694 in the equipment as per site requirement.-Inspection-RDSO | — | 500.00 | — | — | |
| — | — | — | Above/ 50637.50 Below/P | ||
| Suppy of 16 sq mm multi strand single core PVC insulated copper cable as per IS;694 in the equipment as per site requirement.-Inspection-RDSO | — | 250.00 | — | — | |
| — | — | — | Above/ 100637.50 Below/P | ||
| Suppy of 35 sq mm multi strand single core PVC insulated copper cable as per IS;694 in the equipment as per site requirement.-Inspection-RDSO | — | 250.00 | — | — | |
| — | — | — | Above/ 736560.00 Below/P | ||
| Supply, configuration, installation and commissioning of 8 WAN ports Tier 2 Router . Make- CISCO 2901 series or similar. -Inspection-RITES | — | 8.00 | — | — | |
| — | — | — | Above/ 158475.60 Below/P | ||
| Supply of LAN extender as per RDSO specification no. RDSO/SPN/TC/82/2020 Rev.2.0. or latest amndt with digital interface i.e. - Four nos. of ethernet 10/100 base T port as per RDSO specn. and as per site requirement. Make-Cambium, Digisol, D-Link, Cisco, Zyxel or similar.- Inspection-RITES | — | 10.00 | — | — | |
| — | — | — | Above/ 102667.70 Below/P | ||
| Supply of CAT 6 cables. Make-D-Link or similar (1 Box/ Coil- 305 Mtr).-Inspection- Consginee (Unit--Per Coil) | — | 10.00 | — | — | |
| — | — | — | Above/ 99003.00 Below/P | ||
| Laying of Cat-6 cable through wall/duct/conduit including clamping/fixing of duct/conduit over wall ceiling/open space /terrace /existing fixtures etc. as per directives of Railway Site Engineer. It includes supply of PVC conduit/Casing -caping pipe. | — | 3050.00 | — | — | |
| — | — | — | Above/ 164140.26 Below/P | ||
| Supply of PVC insulated flexible 3 core 2.5 sq mm multi strand power cable provided for each of the display boards shall confirm to specification no. IS694:1990 reaffirmed 1995 or latest of reputed brand.-Inspection-RDSO | — | 2.00 | — | — | |
| — | — | — | Above/ 223609.35 Below/P | ||
| Supply, Installation, Testing & Commissioning of Double faced digital clocks for platform area with GPS Synchronized to operate in standalone mode with 7 segments LED Module as per RDSO Specification no. RDSO/SPN/ TC@47>47@ 2008 (Rev.3) or latest with RDSO inspection certificate . (It's inclusive of GPS receiver & Connecting RF cable).-Inspection- supply RITES | — | 5.00 | — | — | |
| — | — | — | Above/ 221376.81 Below/P | ||
| Supply and installation of 24 port PoE network switches with 4 Nos. 10/100/ 1000 Base-T/1000 Base-X SFP ports with 375 watt PoE Power or as per site requirement. Make CISCO/JUNIPER or superior.-Inspection- supply RITES | — | 3.00 | — | — | |
| — | — | — | Above/ 126623.50 Below/P | ||
| Supply installation, testing and commissioning of 8 port Gigabit PoE Layer 2 Switch supports 8 nos 10/ 100/ 1000 BASE-T ports, along with 2 Gigabit SFP ports combo ports PoE power support 130 watt or as per site requirement. Make- CISCO/ Juniper or superior.-Inspection- supply RITES | — | 5.00 | — | — | |
| — | — | — | Above/ 148178.00 Below/P | ||
| Supply of Fiber Patch Cord ((SC/APC - SC/APC, LC-SC/SC-SC/LC-LC/FC-LC) - 10 Mtrs. Length as per site requirement Make:- Digisol/D-Link or similar.-Inspection- Consignee | — | 200.00 | — | — | |
| — | — | — | Above/ 35897.80 Below/P | ||
| Supply & installation of 15 watts Horn speaker with 10 watt tapping, matching transformer and driver unit, make reputed as UHC-15XT of Ahuja make or similar. -Inspection- supply Consignee | — | 20.00 | — | — | |
| — | — | — | Above/ 57435.00 Below/P | ||
| Supply & installation of 25 watts Industrial Horn speaker with 5, 10, 15, 20 watt tappings, matching transformer and driver unit, make reputed as LBD 8347, 8308 of Philips make, UHC-30XT of Ahuja make or similar. -Inspection- supply Consignee | — | 30.00 | — | — | |
| — | — | — | Above/ 162237.12 Below/P | ||
| Supply and installation of Solid state Amplifier model TZA-2000, TZA-4000E Make Ahuja or similar, along with one small stand.-Inspection-supply Consignee | — | 8.00 | — | — | |
| — | — | — | Above/ 183660.00 Below/P | ||
| Supply and Drawing of PVC insulated Screened, Tinned copper conductor 2 core 1.5 Sq. mm cable or good quality Speaker cable/ Audio Cable. .Inspection-supply Consignee | — | 3000.00 | — | — | |
| — | — | — | Above/ 257523.00 Below/P | ||
| Supply of Hands-free Analog Phone with CLI (make-Panasonic TS880MX)Inspection- Consignee | — | 100.00 | — | — | |
| — | — | — | Above/ 232601.60 Below/P | ||
| Supply & installation of IP Phones Inspection-supply Consignee | — | 20.00 | — | — | |
| — | — | — | Above/ 991050.00 Below/P | ||
| Supply and installation of Push Button switch with 2 nos. Config. For BPAC using UFSBI and Block Panel. (Make:- L&T/Siemens).Inspection-supply RITES | — | 300.00 | — | — | |
| — | — | — | Above/ 1336597.50 Below/P | ||
| Supply and installation of basic Earthing kit 1 set as per RDSO Spec. No. RDSO/SPN/197/2008 or latest consisting of: (i) Copper bonded high tensile low carbon steel earth electrode 3.0 Mtr. Long dia 17 mm, , specially designed for electrical grounding - 1 no. (ii) Earth Enhancement compound in 10Kgs bag- 3 Nos. ( iii) Copper tape of 25mm x 6mm x 300mm= 2 Nos. (iv)Copper tape of 25mm x 6mm x 200mm to terminate on earth electrode= 01 No.(v) Supply of insulated connecting cable to connect equipment bus bar 10 meter each earth. Installation of unit earth which includes digging, inserstion,filling , trenching, laying, welding and & Provision of exothermic weld one to connecting cable to the earth electrode and another to the copper tape/35 sqmm multi strand single core PVC insulated copper cable to the copper strip/tape/busbar welded to the copper tape to be fixed inside the Equipment/Relay Rack/Apparatus caseas per RDSO spec.- Inspection- supply RDSO | — | 50.00 | — | — | |
| — | — | — | Above/ 1938961.50 Below/P | ||
| Supply & installation of surge protection device class B+C (Type I+II) of Following Specification. Single Phase with unique feature of progressive indication of the arrester. Iimp (10/350 Micro Sec) (L-N)=25 KA, Iimp (10/350 Micro sec)(N-PE)=60 KA In (8/20 Micro sec)(N-PE)=100KA Voltage Protection Level (L-N) with I (25 KA);1.25 Kv Voltage protection level (N-PE) ;1.50 Kv. or better.-Inspection-supply RITES | — | 150.00 | — | — | |
| — | — | — | Above/ 18844.50 Below/P | ||
| Supply of Integrated Protection Module- Single pair Protection plugwith GDT and PTCs in series. Make - Innotel or similar.-Inspection-Consignee | — | 150.00 | — | — | |
| — | — | — | Above/ 160696.00 Below/P | ||
| Supply of earth electrode.Materials No.SGW/T/3/G/8/89.Inspection-Consignee | — | 80.00 | — | — | |
| — | — | — | per | ||
| — | — | — | E.Rly | ||
| — | — | — | Sketch | ||
| — | — | — | Above/ 452080.00 Below/P | ||
| Installation of Earth Electrode including supply of MS Flat for clamp Signalling equipment such as apparatus cases, Signal posts, etc. | — | 80.00 | — | — | |
| — | — | — | Above/ 5844468.32 Below/P | ||
| Supply of OFC Hybrid Multi service 19" rack mountabledevice IPV6 ready with Auto Change Over featureV.21/V/23 interface device supporting OSPF / IS-IS/BGP / LDP & L2 /L3features for switch and PDH / Elfacility MPLS PDMUJX . LVCD/Digital Axle Counter/MSDAC purpose with four tributary slots & front panelQuad indication status vide LEDs, Optical support vide4SFP port supporting TDMoIP / IPMPLS in the unitsupporting dual core OFC and Four 100/1000mbpsEthernet port (POE required at site supporting 802.3af/ at ) for surveillance/smoke detector,optical SFP portsprovided distance support to be 20 KMs, unit to havetwo E&M card / module each card / module supportingfour 2W/4W configurable & four quad port 2W/4W oreach module without change over feature of 8 portE&M as per site condition. Each port configurable tosupport axle counter/UFSBI/control phone/EC/RTU andone telnet/SNMP port, unit to support 04 El ports inaddition to 04 El ports for internal mapping of PDHtime slots & SFP ports of TDMoIP/ IPMPLS dual DCpower supply 48VDC VDC support , unit to supportchange over mechanism automatic between E&M(V.21) to El port & optical fiber TDMoIP (SFP) & quadpath for E&M interface option, cable to be providedalong with each E&M module . Equipment should beable integrate with direct optical fibre & STM El &IPMPLS 1Gbps ports FABIO 2CX+/OFC/ DC & module2W/4W four port E&M(1+1) protection, the unit to beable to integrate on 1Gbps with IPMPLS devices andcan be networked ; Voice Module 10 port FXO : 01number , 10 port FXS unit to be capable toaccommodate and map on El or 1Gbps as required Make:-FABIO 2CX + /TANSYor similar.Inspection-RDSO | — | 8.00 | — | — | |
| — | — | — | Above/ 277185.92 Below/P | ||
| Installation of Integrated Multiplexer supplied above | — | 8.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022
ATTACHMENT
ACSGCCcorrectionsliplatest.pdf ACS latest
ATTACHMENT
TenderDocomentsig-2026-4.pdf Tender Document
ATTACHMENT
JPOEarthworkdtd21.05.2024.pdf JPO for earth work
ATTACHMENT
GCC_April-2022_2022__GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
ACSGCCcorrectionsliplatest.pdf
ATTACHMENT
TenderDocomentsig-2026-4.pdf
ATTACHMENT
JPOEarthworkdtd21.05.2024.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .