Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L1 | Accepted-AOC Lowest | |
| 2 | L2₹48.7 L+₹7.1 L (17.2%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹49.2 L
EMD Value
₹98,340
Closing Date
23 Nov 2022, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SPL REPAIRS TO BUILDING NO. P-17 OF 2 PUNJAB BN NCC AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2022_MES_555444_2
GE/JULL/ET-62/2022-23
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹98,340
Yes
6 Dec 2022
3 Nov 2022
30 Nov 2022
3 Nov 2022
23 Nov 2022
11 Nov 2022
Amount
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
Material and labour for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius and built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks, old size, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description on brick/ stone wall including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed.
Material and labour for 15mm thick rendering in cement mortar (1:6) on fair faces of brick wall or concrete surfaces and finishing the surface even and smooth without using extra cement complete a
Material and labour for 15mm thick rendering in cement mortar (1:4) on fair faces of brick wall or concrete surfaces and finishing the surface even and smooth without using extra cement complete a
Material and labour for 5mm thick in cement mortar (1:3) as on ceiling including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of new plastered or un-plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Material and labour for preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
Material and labour preparation of new plastered surface of ceiling and applying three coats of white washing complete all as specified and directed.
Material and labour for complete removal of existing treatment from wall surface and applying two coats of cement base paint complete all as specified.
Material and labour complete removal of existing treatment from wall surface and applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified.
Material and labour complete removal of existing treatment from ceiling surface and applying three coats of white wash complete all as specified
Dismantling of brick tiles single layer as in roof covering all as specified and directed.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed
Material and labour for bitumen primer applied on plastered surface of roof at the rate of 0.40 kg/sqm of surface area of roof for water proofing and dump proofing treatment complete all as specified and directed.
Material and labour for applying a coat of hot blown paving industrial bitumen 85/25 at the rate of 1.20 kg/ sqm over the roof surface including cleaning surfaces complete all as specified and directed
Material and labour for APP based polymeric membrane minimum weighing 3.60kg/ sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/ sqm) laid on primed surface by forced application complete all as specified and directed
Material and labour for brick tile but except tiles terracing with 40mm thick brick tiles laid over and including 15mm thick screed in cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
Material and labour for cutting out cracks to V-section in existing RCC roof slabs or terracing, cleaning out and filling with a hot mixture of bitumen VG-10 and clean dry sand 1:1 (by weight) complete all as specified and directed.
Material and labour for flush pointing in cement mortar (1:3) to bricks laid flat on roof and wall complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth courses, roof kerbs or mud stops, benching, coping, bed plates, parapets, water through and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed Note : Reinforcement where provided shall be measured & paid separately
Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area n. exc. 1.5 Sqm each for doors and windows complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area exc. 1.5 Sqm but n. exc. 4 sqm each for doors and windows complete all as specified and directed.
Taking down shutters of any description exc. 1 Sqm and n. exc. 2 sqm each complete all as specified and directed.
Material and labour for mild steel framed work as in door frame, window frames, gates, including hold fasts, clamps etc and necessary cutting, drilling and welding etc complete all as specified and directed
Material and labour for cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required, depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc. half brick but not exc. one brick complete all as specified and directed.
Material and labour 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (two panels), with lock rail and panels of 9mm thick BWP commercial ply or of veneered particle board 12mm thick with commercial veneering on both faces with rails and style. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Material and labour for 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in clause 8.24 (a) of SSR Part-I; supplied and fitted to chowkhats complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site, complete all as specified and directed.
Supply and fixing steel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed skeleton shutter ERW sec 50mm x 20mm and 1mm thick with two openable leaf consisting two No sash bars of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mmx25mm and 1.25mm thick including cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four No for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mm x 3mm made to shape-04 No per window. (b) Handle of z section 20mm x 25mm, 100mm long 01 No per leaf (c) MS tower bolt 150mm long- 2 No per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 No per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: Grills/ guard bars, glass, wire mesh and painted shall be measured and paid separately under respective item of this BOQ.
All as per ser item No. 32.00 but gauged shutters without sash bars.
All as per ser item No. 32.00 but as in ventilators
Supply and fixing mild steel framed work for such as guard bars/ grills, grating etc with end of bars shouldered and/ or riveted forged into spikes, framed guard bars barred iron door, railings and similar work complete conforming to Fe-290 Gde E 165 including one shop coat of zinc chromate primer complete all as specified and directed.
Supply and fixing 100mm size mild steel butt hinges, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
Supply and fixing aluminium handle cast type anodised 100mm long complete all as specified and directed.
Supply and fixing 100mm aluminium anodised, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
Supply and fixing 200mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
Supply and fixing extruded aluminium alloy handles, fabricated type, anodised, D-type, 150mm size, all as specified and directed.
Supply and fixing 100mm size butt hinges extruded aluminium alloy with mild steel hinge pin anodized and fixed complete all as specified and directed.
Material and labour mild steel sliding door bolts 300mm long stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
Supply and fixing mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate welded to steel frame/ screwed to wooden frame complete all as specified and directed.
Supply and fixing floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor overall length of cover plate 150mm complete all as specified.
Material and labour for preparation of new wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour preparation of new or previously untreated steel surfaces of any description, n. exc. 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Material and labour for hacking out old broken glass (any thickness, size, quality or description) from wooden or steel framed glazed with putty or fixed with beads complete all as specified and directed.
Material and labour for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
Material and labour for 3mm thick figured glass, pin head type and glazing with oil putty in squares n. exc. 0.5 sqm in each pane complete all as specified and directed.
Supply and fixing galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ china mosaic including cement mortar bedding (but not backing), removing rubbish off outside MD land complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles of size 300 x 300 x 6 to 7mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles of size 300 x 450 x 6-7mm thick as in vertical surfaces i.e. skirting/ dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface laid over and including 10mm thick rendering in cement mortar (1:4) and finishing the surface fair and even to receive tiles complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exc. 0.18 Sqm but not exceeding 0.38 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
All as per item No 55.00 but in skirting/ dado laid over and including 15mm thick rendering in cement mortar (1:4) as backing coat.
Material and labour for Granite (of any type) 18 to 20mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the said of granite stone as in vertical surfaces including 10mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections complete all as specified and directed.
Material and labour for 15mm bore galvanised steel tubes, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc complete all as specified and directed.
Material and labour for 20mm bore galvanised steel tubes, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc complete all as specified and directed.
Material and labour cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sun shades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 10cm girth in brick walls complete all as specified and directed.
Supply and fixing vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest including CI 'P' or 'S' trap with providing lime concrete bedding and connecting to flushing cistern complete including breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor fixed in repairs complete all as specified.
Supply and fixing vitreous china white wash down water closet pan (Pedestal Pattern) with trap and fixing bolts (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc. and making good to floor/ disturbed surfaces including dismantling the existing unserviceable water closet complete all as specified and directed
Supply and fixing in repair vitreous china wash hand basin, white, flat back size 550 x 400mm including one number brass CP waste coupling, 32mm dia, brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
Supply and fixing vitreous china bowl urinal flat back of size 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed.
Supply and fixing Jet spray with holder for EWC 1.5mtr long suitable for 15mm dia for iron pipe or for brass ferrule all as specified & directed
Supply and fixing peg set of 5 of PTMT fixed to rear side of door shutter in bath complete all as specified and directed.
Supply and fixing in repairs bib taps, cast copper alloy, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe complete all as specified and directed.
Supply and fixing pillar tap, cast copper alloy chromium plated, with capstan heads, 15mm bore dia of pipe screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
Supply and fixing PVC white low level flushing cistern 10 litre capacity with all fittings syphonic action with top push type button with inlet ball valve and float including flush pipe, ball valve, handle, PVC short bend etc. fixed on existing brackets fixed in repairs complete all as specified and directed.
Supply and fixing PVC connection fiber, reinforced 45 cm long 15mm in size with brass check nut and PVC washers at both ends complete all as specified and directed.
Supply and fixing 15mm bore stop cock brass cast copper with butter fly handle, screwed down, high pressure for iron pipes or for unions fixed in repair complete all as specified and directed.
Supply and fixing 15mm bore concealed stop cock brass cast copper with adjustable wall flange, screwed down, high pressure for iron pipes or for unions fixed in repair complete all as specified and directed.
Supply and fixing in repair brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
Material and labour for 75mm PVC (SWR) floor trap plain with grating including jointing to waste pipe fixed with solvent cement fixed in repairs complete all as specified and directed.
Disconnecting of water tanks, setting aside for repairs cleaning and removing all scale and dirt etc from tank and mouths of circular pipes & re-fixing in position complete all as specified and directed
Supply and fixing rotational moulded polyethylene water storage tanks, 500 litres capacity, (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position all as specified in SSR Part I, fixed in position including dismantling of existing tank of any description all as specified and directed.
Supply and fixing ball valve brass high pressure with polythene float and fly nut complete screwed for 20mm bore dia of iron pipe or brass ferrule and fixed complete all as specified and directed
Supply and fixing brass chromium plated tubular towel rail 20mm dia, ‘D’ type, 600mm long between flanges fixed in repairs complete all as specified and directed.
Supply and fixing in repair mild steel CP grating 150mm dia with centre hole all as specified and directed.
Material and labour in repair 25mm dia powder coated mild steel curtain rod, fixed with & including MS powder coated hooks/ brackets and decorative finials (at both side), shade as approved by GE complete all as specified including fixing of long size rawl plugs in wall for MS hook fixed complete all as specified and directed.
Demolition and breaking up drain pipes (Salt Glazed ware, AC or PVC) in event n.exc 150mm dia including all fittings complete all as specified and directed.
Supply and fixing PVC (SWR) rain water pipes single socketed in any length with rubber ring joints laid in floors 110 mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) rain water pipes single socketed in any length with rubber ring joints laid in floors 75 mm bore complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 110mm bore all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 75mm bore all as specified and directed.
Supply and fixing PVC (SWR) vent cowl 110mm bore all as specified and directed.
Demolition of cement concrete in ground floor and paving/ sunken portion (below or above ground level) complete all as specified and directed.
Material and labour for 50mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, laid in panels including finishing the concrete surface even & smooth without using extra cement complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floor, apron etc., laid dry or laid dry and pointed complete all as specified and directed
Material and labour for 60mm thick machine pressed precast concrete inter-locking paver blocks any shape and size conforming to IS 15658-2006, M-35 grade, with grey cement and pigment, laid in floor/ path/ hardstandings in any pattern as approved, laid over complete all as specified and directed. Note : The sample shall be got approved from the GE before build procurement and lots shall be got tested independently by the GE.
Material and labour for 25mm sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails with frame complete all as specified and directed
Supply and fixing false ceiling with Everest fibre cement designer tile ivory painted (high pressure steam cured) of 4mm thickness (as per IS : 14862) of size 595 x 595mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on interlocking meta grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main ‘T’ runner with suitably spaced joints to get required length and 15 x 32mm made from 0.3mm thick sheet and cross ‘T’ of size 15 x 32mm made of 0.30mm sheet, spaced between main ‘T’ at 600mm c/c to form a grid of 600 x 600mm and wall angle of size 15 x 20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including, required cutting/ making, opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc. main ‘T’ runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin, etc with dash fasteners, GI adjustable rods of 3mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main ‘T’ bottom exposed width of 15mm of all T-sections shall be center black pre-painted with polyester paint and having a load bearing capacity of 12 Kg/ Sqm complete all as specified and directed
Excavating in post holes (or similar holes) each n.exc 0.5 cum in soft/ loose soil, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed.
Material and labour for MS work as in conforming to Fe-500-) or Fe-550-0 as in wind ties, posts and struts as directed including drilling holes, notching for wire etc cutting and twisting necessary drilling bolting and riveting or welding including FI 40 x 6mm etc and similar works complete all as specified and directed
Supply only chain link fencing MS galvanized, any size or type complete all as specified
Fixing only chain link fencing MS galvanized, any size or type complete all as specified
Mild steel in flat, round or square bars, in available lengths complete all as specified and directed
Supply and fixing mild steel screw bolts diameter of neck 11 to 15mm (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 5cm but n.exc 10cm long complete all as specified and directed.
Material and labour for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. fixed complete all as specified and directed Note : Each line wire to be measured separately.
Material and labour for concertina coil of 600mm dia on vertical double horn fencing fixed complete all as specified and directed
Supply and fixing steel gate of size 5.50m x 2.10m with RCC columns, excavation & earth work in soft/ loose soil, PCC (1:4:8) type D-2 using 40mm graded stone aggregate, brick work in cement mortar (1:4), rendering in cment mortar (1:4), PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in block/ coping and painting MS work in gate of angle iron, hold fasts and tee iron track, roller and roller plate etc. complete all as specified and as shown on drawing No CEJZ/STD-305/11 Sh 1/5 to 5/5
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface walls, roof, floors etc with any type of civil work involved complete all as specified and directed
Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade PVC insulated FRLS type multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit medium grade (ISI marked) not less than 20mm dia with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers and earth continuity PVC insulated FRLS type cable with stranded copper conductor of size 1.5 sqmm (nominal area) green colour as earth wire connected with earth dolly for one light point controlled by one switch complete all as specified and as directed.
All as per srl item No 108.00 here-in-before but One fan point controlled by one switch
All as per srl item No 108.00 here-in-before but one socket outlet 5 Amp controlled by one switch on independent board.
All as per srl item No 108.00 here-in-before but one socket outlet 5 Amp controlled by one switch on same board.
All as per srl item No 108.00 here-in-before but with 2.5 Sqmm (nominal area) PVC stranded copper conductor cable 3 pin 15 Amp socket outlet with 2.5 Sqmm PVC insulated with stranded copper conductor cable for continuous earth continuity conductor independent board complete all as specified and directed.
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing socket out let 5 Amp, 5 pin flush type complete all as specified.
Supply and fixing socket outlet multipurpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified
Supply and fixing batten holder ISI marked insulated body complete all as specified.
Supply and fixing LED retrofit lamp 9W, 6500K, 220-240V, B-22 base cap complete all as specified and directed.
Supply and fixing ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified.
Supply and fixing five step fan regulator, electronic type, single phase, including connecting complete all as specified and directed.
Material and labour for Sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit medium grade with all fittings including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified. Note : Two runs of single core 4 sqmm and one run of 4 sqmm PVC insulated stranded copper conductor through PVC rigid concealed conduit shall be measured as one RM.
Material and labour for wiring with single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.0 sqmm 1100 volts grade PVC insulated, multi stranded, unsheathed copper wire in colour drawn through in PVC flexible pipe of size 20mm complete all as specified.
Material and labour for wiring with single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 2.5 sqmm 1100 volts grade PVC insulated, multi stranded, unsheathed copper wire in colour drawn through in PVC flexible pipe of size 20mm complete all as specified.
Material and labour for wiring with single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 1.5 sqmm 1100 volts grade PVC insulated, multi stranded, unsheathed copper wire in colour drawn through in PVC flexible pipe of size 20mm complete all as specified. Note of Srl No. 121.00 to 124.00 : The said qty is catered for metering/ protection/ control wiring of VCB, CR Panel at MRS which shall be executed by expert Engineer.
Material and labour for sheet metal enclosure DBs when MCBs to be used, SPN 8 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside with earth bar and neutral bar, prewired complete all as specified.
Supply and fixing MCB SP 6 to 32 Amps, B-curve, 10 KA complete all as specified and directed.
Supply and fixing MCB SPN 32 Amps, B-curve, 10 KA complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 10 to 32 AMP, Complete with connection testing and commissioning all as specified and directed
Supply and fixing Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 20W LED 6500K with square decorative end caps complete all as specified and directed
Supply and fixing energy saving & environmental friendly long life versalite pressure di-cast aluminium luminaire with heat resistant glass and suitable optics for uniform distribution of light 30 watt LED for bldg security lights with high efficiently electronic driver, having IP-66 protection, surge protection min 2 KV power factor more than 0.9 complete operative on AC supply 140 volts to 270 volts pre-wired and product should be made in India qty including bracket made out of GI pipe 25mm dia bent to shape and clamps 40 x 6mm with nuts and bolts prewired products must be made in India only connection and testing complete all as specified. Note: (i) Contractor shall be provided 2 years written manufacture's guarantee for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's
Supply and fixing energy saving bulk head light luminaire with opal diffuser LED 10 watt 6000 K, power factor more than 0.90, IP-65 class-I protection with high efficiency BIS marked LED electronic driver, surge protection 2 KV, operative on 140 volts to 270 volts AC supply complete prewired, connecting and testing complete all as specified and directed. Notes:- (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii) Contractor shall produce LM-79 and LM-80 Report of NABL accredited Laboratory from manufacturer. (iii) Products must be made in India only.
Supply & fixing steel body exhaust fan, 300 mm sweep, 900 rpm, single phase, 230 volt, heavy duty, with lowered shutter including provision of three core flexible cable of required length of size 23/.0076 from ceiling rose/ connector to fan terminal, fixing the fan on wall with suitable size of nut, bolt & washer, including making the hole in wall incl necessary civil/ plastering work to match the disturbed surface complete all as specified and directed by Engineer-in-Charge.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amp 240 V, B-curve, 10 KA including top plug complete all as specified and as directed.
Supply and fixing vertical load-line DB 4 way with bus bars, neutral links, blanking plates suitable for fixing upto 100A MCCB as incomer and MCB for outgoing fixing in wall complete all as specified and directed.
Supply and fixing MCCB FP 63 Amp, 415V with adjustable type, with breaking capacity 25 KA suitable for vertical load-line DB complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 16 Sqmm, 4 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall complete all as specified and directed
Excavation in trenches in hard/ dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erecting poles, stay assembly etc. and getting out complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick each layer complete all as specified and directed..
Removing excavated soil to a distance n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length complete all as specified and directed
Material and labour for sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches and punned down complete all as specified and directed. Note : Punned down thickness of 18cm will be measured.
Supply and fixing 50mm bore galvanised pipe light grade fixed along poles/ to walls/ laid under floor complete with and including fittings and clamps as required complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4 mm dia by means of nut, bolts, check nut & washer of galvanized iron and GI lead protected with protection pipe of GI light grade 15mm dia with thickness of not less than 15cm in alternate layers of charcoal and salt on all sides of earth plate with funnel with wire mesh and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and directed and testing on completion including PCC (1:3:6) type C-1 cover and frame, excavation and earth work and testing etc complete all as specified. Note : On testing, after completion of job, if desired earth resistance is not obtained the earthing shall be redone by the contractor without any extra coat to the department
Supply, install, testing and commissioning of room window type air conditioner of capacity 1.5 Ton, star rated, hot and cold, 100% copper tube, remote complete all as specified and directed Make : Voltas/ Bluestar/ Daikin/ Hitachi/ Carrier/ O-General
Supply, install, testing and commissioning of high wall split type air conditioner of capacity 1.5 Ton, 3 star rated, hot and cold, 100% copper tube, LCD remote with backlight, mounting bracket complete all as specified and directed Make : Voltas/ Bluestar/ Daikin/ Hitachi/ Carrier/ O-General Notes : (a) The quoted rate include provision of copper piping and wiring from indoor unit to outdoor unit upto 6 mtr. (b) Installation should be done through original service provider only.
All as per srl item No. 145.00 here-in-before but 2.0 Ton
Supply and fixing air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR of 5 star rated, inverter technology, 100% copper tube with remote, mounting bracket and suitable size copper piping upto 5 mtr length complete all as specified and directed
Supply and install refrigerator, single door, inverter technology, direct cool, electric driven, capacity not less than 175 Litre, steel/ grey finish, 5 star, single phase, 230 volts, 50 Hz complete all as specified and directed. Make : Godrej/ Haier/ Samsung/ LG/ Whirlpool/ Voltas
Supply and install refrigerator, double door, inverter technology, electric driven, capacity not less than 310 Litre, steel/ sliver/ grey finish, 3 star, frost free, single phase, 230 volts, 50 Hz complete all as specified and directed. Make : Godrej/ Haier/ Samsung/ LG/ Whirlpool/ Voltas
Supply and fixing wall mounted electronic voltage stabilizer metal body, for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 60V to 280V with output voltage stabilized at 230V with accuracy of ±2.5%, built in thermal overload relay protection, low & high voltage cut-off protection and digital display shows input and output voltage of capacity 2 Amp complete all as specified and directed. Make : V-Guard Model No. VSB 50 or equivalent
Supply and fixing wall mounted electronic voltage stabilizer metal body, for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300V with output voltage stabilized at 230V with accuracy of ±2.5%, built in thermal overload relay protection, low & high voltage cut-off protection and digital display shows input and output voltage of capacity 12 Amp complete all as specified and directed. Make : V-Guard Model No. VE 400 or equivalent
Supply and fixing wall mounted electronic voltage stabilizer metal body, for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130V to 300V with output voltage stabilized at 230V with accuracy of ±2.5%, built in thermal overload relay protection, low & high voltage cut-off protection and digital display shows input and output voltage of capacity 15 Amp complete all as specified and directed. Make : V-Guard Model No. VE 500 or equivalent
Supply and install voltage stabilizer for automatic operation single phse naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy ±2.5% and of capacity 4 KVA complete all as specified and directed
Supply, installation, testing and commissioning of float cum boost charger of cap 25 Amp suitable for 220V DC, full wave full controlled battery charger, free standing floor mounted cabinet type with inbuilt DC distribution board having LCD display showing line to line voltage, line to neutral voltage, charger output voltage, charger output current, battery voltage, alarm, ON/ OFF, load voltage, load current, alarm and other required parameters complete front & rear openable type fabricated out of 2.0mm thick steel for load bearing section and 1.5mm for non loading sections with IP-42 Protection, natural air cooled floor mounted comprising with provision of following parameters (Make Amararaja or equivalent) :- (a) Input : Three phase voltage 415V AC±10% (three phase, three/ four wire), 50Hz ±5% (b) Nominal output DC voltage 220V, max output current 25A DC (c) Float voltage 247.5V DC with pron for adjustment, boost voltage-253V DC with provn for adjustment, ripple less than 2% RMS, efficiency not less than 80%. (d) Charger output ±1% of set value in following conditions in set mode (float/ boost/ auto) load variation 10-100%, line variation ±10%, Freq variation ±5%, temp variation 0 to 50 degree temp
(e) LED indicators for AC mains ON, charger ON/ OFF, float ON, Boost ON, charger over voltge, charger under voltage, AC mains fail, SCR fuse fail, battery fuse fail, battery earth fault, load under voltage, load over voltage, battery reverse polarity condition, load under voltage, load over voltage. (f) Proection for AC input circuit breaker, DC over voltage cutback/ shutdown, DC output circuit breaker, fast acting semicundoctor fuse for SCR bridge, DC output, charger current limit, blocking diode, battery curent limit, alarm for any fault causing DC failure. (g) DC distribution board consist with incomer of 63A DP MCB-01 No, outgoing DP MCB consist of 10 Amp-02 Nos, 16 Amp-06 Nos, 25A-02 Nos, 32 Amp-02 Nos (h) Control & switches-AC input ON/ OFF breaker, DC output ON/ OFF circuit breaker, battery input fuses, socket ON/ OFF switch, heater ON/ OFF switch, push button for Menu/ increment/ decrement/ Enter & back (j) Alarm with buzzer facility, soft start on DC side, filter circuit to ripple, charger current limiting, RS-485 4 wire communication, auto phase reversal operation, easy to edit various parameters through contorller.
Supply, installation, testing and commissioning DC battery bank stack 110V/ 100 AH consisting of VRLA maintenance free battery cell-55 Nos of 2V 100 Ah each complete with suitable steel structure frame stack arrangment duly connected all battery cells with suitable size sleeved connector/ bus bar by using reqd thimbles, GI nuts, washers and bolts complete with necessary acessories to make as ready to use pack complete all as specified and directed. Make : Amararaja/ Exide/ HBL
Supply and fixing double door metallic sheet metal enclosure for DB when MCBs to be used V-TPN 4 ways, 415V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables, wires all as directed.
Supply and fixing in replacement MCCB 160 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release ICS=100% ICU with spreader links and phase separator complete all as specified and directed.
Material and labour in replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.5 metre below normal ground level, connected with and including GI wire 4mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15 cm above the normal ground level with MS iron frame on top made of 30x30x3 mm MS angle iron duty painted (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover in (1:2:4) type B-1 using 20mm graded crushed stone aggregate with 1 Nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account.
JAGDISH KUMAR SEHGAL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .