| 1 | L1₹1.1 CrAccepted-AOC 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.1 Cr+₹1.9 L (1.77%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.1 Cr+₹1.9 L (1.77%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.2 Cr+₹9.5 L (8.71%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹1.2 Cr+₹9.5 L (8.71%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.2 Cr+₹10.6 L (9.76%)Rejected-Finance | ₹1.2 Cr+₹10.6 L (9.76%) | L4 | Rejected-Finance Other than L1 |
| 5 | Rejected-Technical AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | - | - | Rejected-Technical Not recommended being not enlisted in appropriate class |
| Sl No | Description | Qty | Unit | national engineering L2 | V S BUILDER L4 | M/S TRADE LINK L3 | VIMAL TRADERS AND SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix in replacement of LT panel of size 0.45 x 0.45m consisting of incoming and out going MCBs, Sensors, Relays, DTC timer 02 Nos for incoming and out going water pipe line tempreature, Single phase preventer, Hooter, contactors etc. and copper wiring as required for fabrication of LT panel with on / off rotory switch, Indication lamp R,Y,B Burner on, off, Trip and any other sensor required at site for running of Boiler of capacity 4 lakh kilo calories per hour complete all as specified and/ or as directed by Engr-in-Charge. | 9 | Each Job | 32,000 ₹2,88,000 | 32,500 ₹2,92,500 | 25,000 ₹2,25,000 | 23,000 ₹2,07,000 Lowest |
| 2.00 | Supply and fix in replacement LT panel of size 0.45 x 0.45m consisting of incoming and out going MCBs, Sensors, Relays, DTC timer 02 nos for incoming and out going water pipe line tempreature, Single phase preventer, Hooter, contactors etc. and copper wiring as required for fabrication of LT panel with on / off rotory switch, Indication lamp R,Y,B Burner on , off, Trip and any other sensor required at site for running of Boiler of capacity 3 lakh kilo calories per hour complete all as specified and/ or as directed by Engr-in-Charge. | 14 | Each Job | 32,000 ₹4,48,000 | 35,500 ₹4,97,000 | 20,000 ₹2,80,000 Lowest | 25,000 ₹3,50,000 |
| 3.00 | Supply & fix in replacement of Chilled / Hot water wall mounting indoor type copper Fan Coil unit with male and female threaded socket including 02 Nos threaded Nipple 6000 K Cal /Hrs capacity and 02 Nos of 20 mm Valve with strainer (inlet & outlet ) and heavy duty PVC Pipe for connection complete all as specified and/ or as directed by Engr-in-Charge. Make Carrier/Voltas/Blue Star or equivalent approved make as approved by GE. ( Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES yard. | 375 | Each | 17,500 ₹65,62,500 | 14,500 ₹54,37,500 Lowest | 17,500 ₹65,62,500 | 18,000 ₹67,50,000 |
| 4.00 | Supply & fixing in replacement of Chilled / Hot water wall mounting indoor type copper Fan Coil unit with male and female threaded socket including 02 Nos threaded Nipple 4500 K Cal /Hrs capacity and 02 Nos of 20 mm Valve with strainer (inlet & outlet ) and heavy duty PVC Pipe for connection complete all as specified and/ or as directed by Engr-in-Charge. Make Carrier/Voltas/Blue Star or equivalent approved make as approved by GE. ( Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES yard. | 75 | Each | 13,500 ₹10,12,500 Lowest | 17,500 ₹13,12,500 | 15,000 ₹11,25,000 | 15,000 ₹11,25,000 |
| 5.00 | Supply and fix in replacement of FCU connection flexible pipe 20/16mm as per existing and as per required length, complete all as specified and/ or as directed by Engr-in-Charge. | 900 | RM | 250 ₹2,25,000 | 220 ₹1,98,000 | 30 ₹27,000 Lowest | 150 ₹1,35,000 |
| 6.00 | Supply and fix in replacement of inlet outlet Ball valve 3/4" for FCU as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge. | 450 | Each Job | 800 ₹3,60,000 | 410 ₹1,84,500 | 400 ₹1,80,000 | 100 ₹45,000 Lowest |
| 7.00 | Supply and fix in replacement of inlet outlet Ball valve 25 mm for FCU as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge. | 450 | Each Job | 800 ₹3,60,000 | 530 ₹2,38,500 | 500 ₹2,25,000 | 250 ₹1,12,500 Lowest |
| 8.00 | Supply and fix in repair / replacement including installing, testing and commissioning of 3 Phase 415 V 50 Hz, double Nozzle diesel burner set of capacity 3 Lac kilo calories /hour capacity 346 KW comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller complete all as specified and/ or as directed by Engr-in-Charge. Make- Ecoflame, Aquatherm, Rapid therm. | 14 | Each | 55,000 ₹7,70,000 | 1,19,400 ₹16,71,600 | 1,11,000 ₹15,54,000 | 500 ₹7,000 Lowest |
| 9.00 | Supply and fix in repair / replacement including installing, testing and commissioning of 3 Phase 415 V 50 Hz, double Nozzle diesel burner set of capacity 4 Lac kilo calories /hour capacity 346 KW comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller complete all as specified and/ or as directed by Engr-in-Charge. Make- Ecoflame, Aquatherm, Rapid therm. | 9 | Each | 65,000 ₹5,85,000 Lowest | 1,25,000 ₹11,25,000 | 1,31,000 ₹11,79,000 | 1,70,000 ₹15,30,000 |
| 10.00 | Supply and fix in repair / replacement including, testing and commissioning of Rotory Gear Oil Transfer Pump of capacity 15 LPM, 10 Mtr Head including taking down of old unserviceable existing pump and deposit to MES Store yard complete all as specified and/ or as directed by Engr-in-Charge. | 8 | Each Job | 18,000 ₹1,44,000 | 24,500 ₹1,96,000 | 18,000 ₹1,44,000 | 7,500 ₹60,000 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
23 Jul 2025, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
SPECIAL REPAIR TO LT PANELS, OIL FIRED BURNER, FCU AND ALLIED ACCESSORIES AT LSRC UNDER GE 865 EWS
2025_MES_714180_1
138WE/L-69/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹2.1 L
Yes
9 Sept 2025
13 Jun 2025
30 Jul 2025
13 Jun 2025
23 Jul 2025
4 Jul 2025
Amount
Supply and fix in replacement of LT panel of size 0.45 x 0.45m consisting of incoming and out going MCBs, Sensors, Relays, DTC timer 02 Nos for incoming and out going water pipe line tempreature, Single phase preventer, Hooter, contactors etc. and copper wiring as required for fabrication of LT panel with on / off rotory switch, Indication lamp R,Y,B Burner on, off, Trip and any other sensor required at site for running of Boiler of capacity 4 lakh kilo calories per hour complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in replacement LT panel of size 0.45 x 0.45m consisting of incoming and out going MCBs, Sensors, Relays, DTC timer 02 nos for incoming and out going water pipe line tempreature, Single phase preventer, Hooter, contactors etc. and copper wiring as required for fabrication of LT panel with on / off rotory switch, Indication lamp R,Y,B Burner on , off, Trip and any other sensor required at site for running of Boiler of capacity 3 lakh kilo calories per hour complete all as specified and/ or as directed by Engr-in-Charge.
Supply & fix in replacement of Chilled / Hot water wall mounting indoor type copper Fan Coil unit with male and female threaded socket including 02 Nos threaded Nipple 6000 K Cal /Hrs capacity and 02 Nos of 20 mm Valve with strainer (inlet & outlet ) and heavy duty PVC Pipe for connection complete all as specified and/ or as directed by Engr-in-Charge. Make Carrier/Voltas/Blue Star or equivalent approved make as approved by GE. ( Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES yard.
Supply & fixing in replacement of Chilled / Hot water wall mounting indoor type copper Fan Coil unit with male and female threaded socket including 02 Nos threaded Nipple 4500 K Cal /Hrs capacity and 02 Nos of 20 mm Valve with strainer (inlet & outlet ) and heavy duty PVC Pipe for connection complete all as specified and/ or as directed by Engr-in-Charge. Make Carrier/Voltas/Blue Star or equivalent approved make as approved by GE. ( Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES yard.
Supply and fix in replacement of FCU connection flexible pipe 20/16mm as per existing and as per required length, complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in replacement of inlet outlet Ball valve 3/4" for FCU as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in replacement of inlet outlet Ball valve 25 mm for FCU as per existing, including MS / GI nipple of size 3/4 inch, necessary welding work and cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in repair / replacement including installing, testing and commissioning of 3 Phase 415 V 50 Hz, double Nozzle diesel burner set of capacity 3 Lac kilo calories /hour capacity 346 KW comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller complete all as specified and/ or as directed by Engr-in-Charge. Make- Ecoflame, Aquatherm, Rapid therm.
Supply and fix in repair / replacement including installing, testing and commissioning of 3 Phase 415 V 50 Hz, double Nozzle diesel burner set of capacity 4 Lac kilo calories /hour capacity 346 KW comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller complete all as specified and/ or as directed by Engr-in-Charge. Make- Ecoflame, Aquatherm, Rapid therm.
Supply and fix in repair / replacement including, testing and commissioning of Rotory Gear Oil Transfer Pump of capacity 15 LPM, 10 Mtr Head including taking down of old unserviceable existing pump and deposit to MES Store yard complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in repair / replacement including, testing and commissioning of monoblock centrifugal pump of capacity 5 LPM, 5 Mtr Head including taking down of old unserviceable existing pump and deposit to MES Store yard.
Material and labour for cutting welding cold or hot for fixing of butterfly valve, reducer, fixing of burner or any other work required at site for fixing of MS Pipe line etc. complete all as specified and/ or as directed by Engr-in-Charge.
Material and labour for repair of broken fire refractory and leaking of boiler coil of any size and any make by using fire refractory cement as existing oil fired boiler including welding of boiler coil complete and making crackproof, and leak proof complete all as specified and/ or as directed by Engr-in-Charge.
Material and labour for filling of mass concrete into cutting of road or broken foundation by using cement mortor 1:2:4 type B2 (using 40mm graded aggregate) complete all as specified and/ or as directed by Engr-in-Charge.
Supply and fix in replacement of old unserviceable switch socket combination out let two in one 5 pin 6 Amps with box 230 Volts complete all as specified and/ or as directed by Engr-in-Charge.
national engineering (BID ID -3354937)
M/S TRADE LINK (BID ID -3363501)
V S BUILDER (BID ID -3368998)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .