Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹12.8 L+₹1.4 L (12.1%)Rejected-AOC 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹12.9 L+₹1.5 L (13.6%)Rejected-AOC N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹13.4 L+₹2.0 L (17.9%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹13.8 L+₹2.4 L (21.4%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹36,600
Closing Date
7 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE U W S DELHI CANTT 10
GE U W S DELHI CANTT 10
REPAIR REPLACEMENT OF LT PANELS CONNECTION CABLES AND ALLIED WORKS IN THE AREA OF AGE U WS II UNDER GE U W S DELHI CANTT 10
2020_MES_385235_1
GE/WS/D-106 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
GE U W S DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U W S DELHI CANTT 10
₹36,600
Yes
13 Jan 2021
10 Oct 2020
10 Nov 2020
10 Oct 2020
7 Nov 2020
24 Oct 2020
60 days
Amount
Supply, installing, testing and commissioning factory made CPRI approved and tested LT Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work made out of 50 mm x 50 mm X 6 mm), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating mounted on PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to in and including accomodate the following items and all as specified and directed by Engr-in-charge by dismantling exisiting unserviceable LT panel complete. (a) 01x200A 25 KA 4 Pole - Incoming MCCB (Make:legrand/siemens/L&T) (b) 03x63A 25 KA 3 Pole - Outgoing MCCB (Make:legrand/siemens/L&T) (c) 04x32A MCB-Outgoing SPN Note :- (i) Contractor shall take approval of Accepting Officer for panel drawing before fabrication work.
Taking out existing LT UG cable laid in trenches/fixed to poles etc of following sizes complete all as specified and as directed. Note : Excavation will be measured and paid seperately under relevant items
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 core 120 sqmm
Relaying /relaying of existing LT UG cable laid in trenches/fixed to poles same after connected repair works cable of following sizes complete all as specified and as directed. Note : Excavation will be measured and paid seperately under relevant items
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 core 120 sqmm
Material and labour for XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade of following dia of cable laid in trenches/fixed to poles complete all as specified and as directed.
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 core 120 sqmm
Laying only sub class 'B' bricks old sizes over the LT cable laid flat for protection of cable complete all as specified and as directed.
Supplying and laying for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Supplying and laying sub class 'B' bricks old sizes over the LT cable laid flat for protection of cable complete all as specified and as directed.
Supply and fixing in single door right handed opening juncion box/pole box for street light including all fitting with suitable cable complete all as specified and as directed.
Repair/maintenance of juction box/pole box as per site including serviceable of bus bar,mcb & changing of cable or make it serviceable condition complete all as specified and as directed.
Supply and fixing in replacement of decorative gate light MASHROOM (PRISMATIC) including 20W LED lamp made up of high grade breakable polycarbonate material for retrofit complete all as specified and as directed.
Repair/maintenance of decorative gate light including changing of LED lamp,damaged light cover,cable, & MCB or make it serviceable as per site complete all as specified and as directed.
Supply and fixing in replacement of 20W surface/wall mounted 4 feet LED batten light with all fitting, extruded aluminium housing provided complete all as specified and as directed.
Material and labour for point wiring 1.5 Sqmm PVC insulated and unsheathed cable with copper conductor 1100 Volts grade, multistranded alongwith earth wire in existing surface / recessed steel / PVC conduits with PVC insulated copper wire including taking down worn out wires etc complete all as specified and as directed.
All as per srl item No-16- here-in-before but 2.5 Sqmm complete all as specified and as directed.
Taking down old UNSV of any description type changeover switch and S&F Off-load changeover switches in sheet steel encloser 415V, 50 Hz 63Amps 4 Pole on existing pole/wall complete all as specified and as directed.
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches in sheet steel encloser 415V, 50 Hz 100 Amps 4 Pole on existing pole/wall complete all as specified and as directed.
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches in sheet steel encloser 415V, 50 Hz 200 Amps 4 Pole on existing pole/wall complete all as specified and as directed.
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches in sheet steel encloser 415V, 50 Hz 315 Amps 4 Pole on existing pole/wall complete all as specified and as directed.
Taking down the unserviceable LED indicating lamps (panel mounting) and replacing with new LED indicating lamps complete including connecting and testing complete all as specified and as directed.
Taking down the unserviceable start button from existing panel and replacement with new start button complete all as specified and as directed.
Taking down the unserviceable terminal block any type and replacement with new one terminal block 100A - 3 way (For MU-G30/50) complete all as specified and as directed.
Taking down the unserviceable power contactor of any size and replacement with new power contactor ML 1.5 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor of any size and replacement with new power contactor ML 2 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor of any size and replacement with new power contactor ML 3 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor of any size and replacement with new power contactor ML 4 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 18 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 32 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 40 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactoror any size and supply and fixing new power contactor MNX 70 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 80 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 95 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 110 in existing starter panel complete all as specified and as directed.
Taking down the unserviceable FASD ML 1.5 (with MU relay) of any size and replacement with new FASD ML 1.5 (with MU relay) 25 HP including stainless steel box existing starter panel complete all as specified and as directed.
Taking down the unserviceable FASD ML 2 (with MU relay) of any size and replacement with new FASD ML 2 (with MU relay) 35 HP including stainless steel box existing starter panel complete all as specified and as directed.
Taking down the unserviceable FASD ML3 (with MU relay) of any size and replacement with new FASD ML3 (with MU relay) 50 HP including stainless steel box existing starter panel complete all as specified and as directed.
Taking down the unserviceable FASD ML 4 (with MU relay) any size and replacement with new FASD ML4 (with MU relay) 75 HP including stainless steel box existing starter panel complete all as specified and as directed.
Taking down the Direct on line starter for 7.5 Hp motor relay range 20-32 and replacement with new DOL starter 7.5 Hp relay range 20-32 in existing starter panel complete all as specified and as directed.
Taking down the Direct on line starter for 10 Hp motor relay range 20-32 replacement with new DOL starter 10 Hp relay range 20-32 in existing starter panel complete all as specified and as directed.
Taking down the Direct on line starter for 15 Hp motor relay range 20-32 and replacement with new Direct on line starter 15 Hp relay range 20-32 in existing starter panel complete all as specified and as directed.
Taking down the Direct on line starter for 20 Hp motor relay range 14 -23 replacement with new Direct on line starter 20Hp relay range 20-32 in existing starter panel complete all as specified and as directed.
Taking down unsserviceable street light fitting 45W/60W any make and replacement with new driver/LED lamp existing suitable make and model make it funcional complete all as specified and as directed.
Supply and laying earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanised iron strip complete all as specified and as directed.
Material and labour for cable joint kit of size 4 core 16 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 4 core 25 sqmm for heat shrinkable straight through joint complete all as specified and as directed.
Material and labour for cable joint kit of size 3.5 core 35 sqmm for heat shrinkable straight through joint complete all as specified and as directed.
Material and labour for cable joint kit of size 3.5 core 50 sqmm for heat shrinkable straight through joint complete all as specified and as directed.
Material and labour for cable joint kit of size 3.5 core 70 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 3.5 core 95 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 3.5 core 120 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situtation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and as directed. Note :- (i) Cable jointing kit shall be measured and paid separately. (ii) Old retrieved bricks/cable cover shall be reused (iii) The rates quoted includes excavation & earth work with sand cushioning.
Material and labour for earthing complete with galvanized steel earth plate 60cmX 60cmX6 mm thick buried vertically in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to earth lead wire 4.0 mm dia by means of welding, GI thimbles, nut bolts and washers using GI or steel all surrounded by adequate quantity of charcol dust and salt to a packed thickness of 15 mm on all sides, earth strip encased in 40 mm GI medium grade pipe, including providing watering pipe 20 mm dia GI pipe medium grade from bottom of the earth pit the top of the electrode complete with earth pit in PCC 1:2:4 typr B-0 using 12 mm graded crushed stone aggregate, earth work and RCC cover complete all as required at site and specified in EP No. 3 of MES SSR part I or directed by engg-in-charge and including taking down..
Material and labour for earthing complete with galvanized steel earth plate 60cmX 60cmX6 mm thick buried vertically in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to earth lead 32 mm x 6 mm strip by means of welding, GI thimbles, nut bolts and washers using GI or steel all surrounded by adequate quantity of charcol dust and salt to a packed thickness of 15 mm on all sides, earth strip encased in 40 mm GI medium grade pipe, including providing watering pipe 20 mm dia GI pipe medium grade from bottom of the earth pit the top of the electrode complete with earth pit in PCC 1:2:4 typr B-0 using 12 mm graded crushed stone aggregate, earth work and RCC cover complete all as required at site and specified in EP No. 3 of MES SSR part I or directed by engg-in-charge and including taking down..
Material and labour for comet aluminium tubular terminals/lugs of size 16 Sqmm to 35 Sqmm in existing burned LT cable/wire complete all as specified and as directed.
Material and labour for comet aluminium tubular terminals/lugs of size 50 Sqmm to 120 Sqmm in existing burned LT cable/wire complete all as specified and as directed.
Supply & fixing tube light rod 20watt, length 4 feet complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 1 relay range 10-16 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 1 relay range 18-21 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 1 relay range 20-32 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 1 relay range 28-42 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 2/3 relay range 13-21 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 2/3 relay range 20-32 Amps in existing panel complete all as specified and as directed .
Supply & fixing Thermal over load relay, type ML 2/3 relay range 28-42 Amps in existing panel complete all as specified and as directed .
Supply & fixing LED bulb 9 Watt B 22 luman efficiency 90 Im/w,white cool day light complete all as specified and as directed.
Material & labour for repair to existing earthing pit by dismentling unserviceable brick work after necessary excavation & earth work and construction of pit with new brick work using sub class B brick and plaster as required,replacing alternate layer of charcoal/ salt as per electrical plate No-03, providing & connected earthing lead wire 4 mm dia of length as required by means of bolt,nuts and check nuts to make earthing funcional after testing complete all as specified and as directed.
Material and labour 25 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.
Material and labour 35 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.
An amount of Rs 41,716.40 shall be deducted from BOQ on account of schedule of credit
S S CONSTRUCTION
M/S Rohit Enterprises
Flint India
Ridhi engineers and builders
Deven Associates
somyaenterprises
Surjit and Sons
Tushar engineers
Yadav Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .