Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.8 LAccepted-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹88.8 L | L1 | Accepted-AOC QUOTED RATE LOWEST AND REASONABLE |
| 2 | L2₹89.8 L+₹96,971 (1.09%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹89.8 L+₹96,971 (1.09%) | L2 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 3 | L3₹1.1 Cr+₹17.1 L (19.3%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹1.1 Cr+₹17.1 L (19.3%) | L3 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 4 | L4₹1.2 Cr+₹26.3 L (29.6%)Rejected-Finance | ₹1.2 Cr+₹26.3 L (29.6%) | L4 | Rejected-Finance QUOTED RATE NOT LOWEST |
| 5 | L5₹1.2 Cr+₹31.2 L (35.1%)Rejected-Finance | ₹1.2 Cr+₹31.2 L (35.1%) | L5 | Rejected-Finance QUOTED RATE NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
22 Jan 2025, 6:00 pmClosed
CWE KOLKATA
Headquarter Commander Works Engineers Military Engineer Services No1 National Library Avenue Alipore Kolkata700 027
ADDN ALTN AND SPECIAL REPAIR OF FIRE FIGHTING SYSTEM AT COMD HOSP AND II LINE UNDER GE ALIPORE KOLKATA
2024_MES_688514_1
C/8365/E-22/24-25
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
210 days
GE ALIPORE KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
GE ALIPORE kOLKATA
₹1.9 L
Yes
29 Mar 2025
13 Dec 2024
29 Jan 2025
13 Dec 2024
22 Jan 2025
3 Jan 2025
14 Dec 2024 - 21 Dec 2024
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Supply, Installation, Testing and Commissioning of based intelligent analogue addressable, modular, expandable networkable, five loop fire alarm control panel of capacity of 127 nos analogue addressable devices(each loop) and 127 nos base sounders / base sounder beacons(each loop). The control panel shall have expandable capacity from 2 loops to 16 loops. The Panel must have Full colour 8 x 480 LCD with resistive touch screen and automatic black light dimming. The Panel must also have the capability to take addressable intelligent wired and wireless devices on same loop and an event log of minimum 10,000 events @1 Second resolution, filterable and Printable, three access levels panel shall support upto 5000 causes & effects entries, with upto 20,000 inputs controlling & 20,000 Controlling output across the network and peer to peer networking through RS 485 network card. Fire control panel shall be conforming to EN54-2, EN54-4 and approved by LPCB(Loss Prevention Council Board) complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of based intelligent analogue addressable, modular, expandable networkable, Six loop fire alarm control panel of capacity of 127 nos analogue addressable devices(each loop) and 127 nos base sounders / base sounder beacons(each loop). The control panel shall have expandable capacity from 2 loops to 16 loops. The Panel must have Full colour 8 x 480 LCD with resistive touch screen and automatic black light dimming. The Panel must also have the capability to take addressable intelligent wired and wireless devices on same loop and an event log of minimum 10,000 events @1 Second resolution, filterable and Printable, three access levels panel shall support upto 5000 causes & effects entries, with upto 20,000 inputs controlling & 20,000 Controlling output across the network and peer to peer networking through RS 485 network card. Fire control panel shall be conforming to EN54-2, EN54-4 and approved by LPCB(Loss Prevention Council Board) complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of based intelligent analogue addressable, modular, expandable networkable, one loop fire alarm control panel of capacity of 127 nos analogue addressable devices and 127 nos base sounders / base sounder beacons and have inbuilt one loop and expandable capacity upto 2 loops.. The Panel shall large graphic display and the capability to take addressable intelligent wired and wireless devices on same loop and 240 V AC power supply along with automatic Battery Charger. Fire control panel shall be conforming to EN54-2, EN54-4 and approved by LPCB(Loss Prevention Council Board) complete all as specified and as directed.
Supply, installation, testing and commissioning of network module with connect panels, repeator panels for RS-485 data at a Baud rate of 115200 Bauds and including configured with master / slave, multiple master / slave complete all as specified and as directed
Supply, Installation, Testing and commissioning of repeater panel allows a full display and optional control of the main fire alarm control panel from a small and unobtrusive local control station. Robust, full colour display of size 7" 800 x 480 with touch screen graphical and approved by LPCB complete all as specified and as directed.
Supply, installation, testing and commissioning of response indicator for all detectors located below false ceiling and below false flooring areas complete all as specified and as directed.
Supply, installation, testing and commissioning of sensor isolator mounting base, includes stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps, facility for remote indicator, approved by LPCB complete all as specified and as directed.
Supply, installation, testing and commissioning of analogue addressable single input module with a single monitored input, flying leads for easy installation, electronically addressed conforms to relevant BIS complete all as specified and as directed.
Supply, installation, testing and commissioning of analogue addressable single output module with a single output, flying leads for easy installation, electronically addressed and conforms to relevant BIS complete all as specified and as directed.
Supply, installation, testing and commissioning of optical beam smoke detector with 5m to 100m range, automatic compensation, automatic signal strength adjustment, emitter unit shall be powered directly from zone (or loop), features a latching or non-latching fault relay with interfaced onto ESP system via a zone module, full line continuity options, conforms to relevant BIS complete all as specified and as directed.
Supply, Laying , Testing and Commissioning of 2C x 1.5 Sqmm copper LT XLPE ARMOURED CABLE for firefighting circuit wiring and sheath with confirming to IS standards and specifications. The quoted rate shall inclusive of suitable saddles, hardwares etc complete for fire alarm system.
Supply, install, fixing, commissioning and testing of fire pump electrically driven horizontal end Suction, centrifugal type pump (Main Pump for hydrant system) confirming to IS- 12469 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings, mechanical seals Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase, 50 Hz , energy efficieny-1, IP 55 protection Squirrel cage, TEFC induction motor of suitable capacity for 90m Head, 2280 litre per minute( LPM ) discharge and conforming to IS : 12615 , AC supply 415Volt, 3 phase , flexible coupling and including foundation as per manufacturer's recommendation with nuts and bolts including anti vibration pads, painting and connection with suction & discharge water main complete with standard fittings and necessary electric connections with PVC insulated industrial heavy duty cable suitable size, 1100 volt and necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pump set as well as testing of automation with required length and size of medium grade GI pipe and control valves for proper completion of work complete all as specified and as directed. Notes :- (i) Necessary foundation, base frame & bolting required for installation pump set shall be provided as per manufacturer's recommendationand the cost for the same shall be deemed to be included in the rates quoted in this item. (ii) The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of its rated discharge at 65% of rated head. (iii) The cost of PVC insulated industrial heavy duty cable, Pressure Switch for automatic operation of motor and all other standard accessories shall be deemed to be included in the rates quoted for this item.
Supply, install, fixing, commissioning and testing of diesel engine driven fire pump (Stand by Pump) of for 90m Head, 2280 litre per minute( LPM ) discharge suitable for automatic operation consisting of following:- (a) Horizontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge complete with necessary strainers, pressure gauge including by pass arrangement for periodic testing of the working of the pump set as well as testing of automation with required length and size of medium grade GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rates head with Mechanical seals , enclosed type bronze impeller and accurately balanced dynamically, cast iron casing, and stainless steel , , anti vibration pads complete all as specified and as directed. (b) Diesel engine developing suitable BHP for the above capacity pump set with manual and automatic starting mechanism including engine starting panel, lead acid batteries of 24 V, 180 AH battery charger unit, desel tank for eight hours complete with inlet and outlet connections, fuel filter, fuel lift pump, oil indication gauge, exhaust silencer, exhaust system of suitable dia, class 'C' M.S. pipe including 50mm thick rock wool insulation and cladded with 22 gauge aluminium sheet in an approved manner, fly wheel, air intake manifold, air cleaner, radiator, radiator fan, lub, oil, pressure gauge, filter, cooling water temperature gauge and all other accessories required to complete the system. The diesel engine shall be rated for continuous duty and shall have BHP rating necessary to drive the pump at 150% of its rated discharge at 65% of rated head . The diesel engine shall be strictly compiling of Central Pollution Control Board (CPCB) emission norms four as per GOI notification.
Cont… (c ) Supply, installation, testing and commissioning of AMF autostart panel complete with necessary relays like no volt relay, over voltage and low voltage relays, contactors, timer, pressure switch etc as required for the auto start of the diesel engine in case of power failure complete with all accessories, wiring & cabling including connection to diesel engine complete all as required all in conformity with the local Fire regulations. Notes :- (i) Necessary foundation, base frame, bolting required for installation pump Diesel engine shall be provided as per manufacturer's recommendation and the cost for the same shall be deemed to be included in the rates quoted for this item. (ii) The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of its rated discharge at 65% of rated head. (iii) The cost of PVC insulated industrial heavy duty cable, Pressure Switch for automatic operation of motor and all other standard accessories shall be deemed to be included in the rates quoted for this item.
Supply, install, fixing, commissioning and testing of electrical motor driven fire pump (JOCKEY Pump) 90m Head, 180 litre per minute( LPM ) discharge suitable for automatic operation consisting of following:- (a) Horizontally mounted, split casing, Centrifugal fire pump confirming to IS- 12469 complete for delivery of under mentioned discharge complete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size of medium grade GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rates head with Mechanical seals , enclosed type bronze impeller and accurately balanced dynamically, cast iron casing, and stainless steel and installed over anti vibration pads (b) Squirrel cage, TEFC induction motor, energy efficieny-1 suitable for 415 V, 3 Phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of its rated discharge at 65% of rated head completion of work complete all as specified and as directed. Notes :- (i) Necessary foundation, base frame & bolting required for installation high pump set shall be provided as per manufacturer's recommendation and the cost for the same shall be deemed to be included in the rates quoted for this item. (ii) The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of its rated discharge at 65% of rated head. (iii) The cost of PVC insulated industrial heavy duty cable, Pressure Switch for automatic operation of motor and all other standard accessories shall be deemed to be included in the rates quoted for this item.
Supply & fixing of 100 mm bore pipe heavy duty class "C" MS pipe 6 mm thick, ISI marked as per IS:1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding as required of pipe complete with necessary standard clamps structural steel supports as required / directed at site including painting of two coats of synthetic enamel paint of post office red colour over one coat of red oxide primer on exposed surface complete all as specified and directed
Supply & fixing of 80 mm bore pipe heavy duty class "C" MS pipe 6 mm thick, ISI marked as per IS:1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding as required of pipe complete with necessary standard clamps structural steel supports as required / directed at site including painting of two coats of synthetic enamel paint of post office red colour over one coat of red oxide primer on exposed surface complete all as specified and directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil, including road cutting for laying of cables / pipes etc complete all as specified and directed
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Supply & fixing of Fire hydrant landing valve type B (single head outlet) gunmetal of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with couplings conforming to IS 903 complete all as specified and directed. Make:- Minimax / Firex / Safes / Newage
Supply & fixing of Fire hydrant landing valve type B (double head outlet) gunmetal of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with couplings conforming to IS 903 complete all as specified and directed.
Supply & fixing of weather proof standard fire hose box made of 18 gauge MS sheet 800mm x 60mm x 250mm with double door with 4mm thick glasses and door frame made of 18 gauge MS sheet including locking arrangement by allen key, stove enamelled fire red finish with "Fire hose" marked on front and brilliant white inside yard, suitable for housing of 2 lengths RRL hose pipe 15 mtr long conforming to IS:636-1979(type-II) of 63 mm dia, branch pipe and nozzle 12.5 mm dia complete all as specified.
Supply & fixing of RRL hose pipe of 15 mtr long conforming to IS:636-1979(type-II) of 63 mm dia, GM instantaneous male and female coupling (IS:903) and branch pipe and nozzle 12.5mm dia complet all as specified and directed.
Supply & fixing of 63mm dia branch pipe gun metal instaneous inlet and made threaded outlet, 15mm bore nozzle short for hose reel complete all as specified and directed
Supply & fixing of Gun metal two way Fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with balnk cap and chain .
Supply & fixing of CI butterfly valve of size 100mm dia conforming to IS : 13095, flanged ends, drilled type with steel spindle including nuts, bolts, washers and jointing materials complete all as specified and directed.
Supply & fixing of CI butterfly valve of size 80mm dia conforming to IS : 13095, flanged ends, drilled type with steel spindle including nuts, bolts, washers and jointing materials complete all as specified and directed.
Supply & fixing of Air vessel 250mm dia 1 m height complete all as specified and directed.
Supply & fixing of 100mm (4") dia Burden type, stainless steel dial type pressure guage having calibration of 0-21 Kg/Cm2 including brass isolation valve and pipe complete all as specified and directed
Supply & fixing of wall mounting swinging type First aid fire hose reel drum, hanging bracket, 30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gunmetal shut off nozzle having 5mm dia orifice. The hose reel shall be confrming to IS 884-1985. Rate shall include for 25mm dia MS pipe connection from riser to hose reel sockets, nipples, elbows and ball valve (25mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete book or MS stand as per site requirement and the rate for fixing / hanging items in the rates quoted (for internal hydrant and one each on either side of stage) complete all as specified and directed
Supply & fixing of Fire alarm sounder / siren electronic type horizontal single stage continous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db, 500 mtr range complete all as specified and directed
Material & labour of construction of brick masonry chamber with subclass `B' brick in CM (1:6) with PCC (1:4:8) type D2 for foundation of internal dimension of 120mx120cmx120cm including 15mm thick plastering in CM (1:4) inside the chamber and on the external portion exposed above ground level, including 3mm thick MS cover welded around with MS flat iron of size 40x6mm including MS angle iron frame of size 40x40x6mm with locking arrangement including painting with two coats of synthetic enamel paint over a coat of red oxide primer including necessary earthwork in soft/loose soil well ramming of soil around the constructed chamber all as specified and directed
Supply and fix double flanged single door type swing check reflux (Non return) with by pass arrangement valve in repair conforming to IS-5312 of size 100 mm including supply and fixing suitable size of nut bolts and gasket etc complete all as directed
Cutting the existing MS Pipe line upto 150mm dia bore by necessary welding or any other means and insertion of flanged MS / GI Tee for new connection upto 50mm dia bore complete form work including excavation and earth work for branch connection from the existing MS pipe line complet all as directed
NIRMAL SALES CORPORATION (BID ID -3221296)
S.M.CONSTRUCTIONS (BID ID -3221532)
M/s R.V. Constructions (BID ID -3211199)
Adhunik Infrastructures Pvt Ltd (BID ID -3215132)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .