| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹7.6 L+₹2,213 (0.29%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance Financially Rejected | |
| 3 | L3₹7.6 L+₹7,397 (0.98%)Rejected-Finance 6201 M G ROAD KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-Finance Financially Rejected |
| Sl No | Description | Qty | Unit | M/s Singh Electrical Works L2 | SUMAN ENTERPRISE L3 | BADAL CHANDRA DAS CO. L1 |
|---|---|---|---|---|---|---|
| .90Part: A (Electrical Installation Work): | ||||||
| 1.00 | Dismantling the existing damaged BDB, switch board, wiring, cable, fittings & fixture as required very carefully & carrying the same to safe place as per direction of EIC. | 1 | Item | 1,250 ₹1,250 | 1,300 ₹1,300 | 1,200 ₹1,200 Lowest |
| 2.00Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC conduit (rigid) (Precision make) incl. necy. PVC clips, fittings etc. | ||||||
| 2.10 | 4 x 10 & 2 x 6 mm² for Timer DB to Loop Box and Loop Box to AC ODU Terminal. | 50 | Mtr. | 660 ₹33,000 | 662 ₹33,100 | 650 ₹32,500 Lowest |
| 3.00Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. | ||||||
| 3.10 | 4 x 10 & 2 x 6 mm² cu. Wire. | 8 | Sets. | 63 ₹504 | 64 ₹512 | 62 ₹496 Lowest |
| 4.00 | Supplying and fixing 3 phase AC Timer with IP-43 protection, powder coated provision for MCB, on wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. S&F SS 4 Way HTPN DB enclosure comprising with 1 no. 63A FP MCB (BB40630C) as incomer & 2 nos. 32A FP MCB as outgoing (BB40320C), 2 nos. 63A FP power Contractor (MCX 12) with 2NO+2NC auxiliary contact, 1 no. 24 hrs. digital timer switch (Cat no 67DDT0.), 2 nos 2 way Auto-manual bypass switch, 1 no 10A single way switch for contractor selection switch and 2 nos. Indicating lamp with 6 A SP MCB for control circuit incl. necessary interconnection and earthing attachment for 3 phase AC machine starter as per direction of EIC. | 1 | Set. | 24,600 ₹24,600 | 25,000 ₹25,000 | 23,000 ₹23,000 Lowest |
| 5.00 | Supplying & fixing of PVC cable end loop box of size (270 x 225 x 135 mm) including providing drilled holes incl all necessary items as required for the input power of ODU of AC System. (Make: Syntex) (Model No.: GSJB 3126) | 2 | Nos. | 1,515 ₹3,030 | 1,517 ₹3,034 | 1,508 ₹3,016 Lowest |
| 6.00 | Supply & Fixing of MCB Mounting CHANNEL WHITE – Din 35 Rail (35 x 7.5 x 0.8 mm) White plated in the existing PVC loop box including providing drilled holes incl all necessary items as required for the fixing of MCB Isolator. | 1 | Mtr | 149 ₹149 | 150 ₹150 | 147 ₹147 Lowest |
| 7.00 | Supplying and fixing 240/415 V 4 Pole 63 A MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand) | 2 | Nos. | 1,100 ₹2,200 Lowest | 1,150 ₹2,300 | 1,820 ₹3,640 |
Tender Value
₹7.6 L
EMD Value
₹15,180
Closing Date
10 Jul 2025, 5:30 pmClosed
Exe. Engr._I, Kolkta South Health El. Divn, PWDte
O/o The Executive Engineer Kolkata South Health Electrical Division P.W.Dte. 75, Diamond Harbour Road, Kolkata - 700 023
Urgent Requiretment of 2 Nos. 16.5 KW/ 5.0 Tr Cooling Capacity Concealed Split AC Machine with allied Electrical Installation Works at Server Room, Department of IT Personnel, Computer Server Room at 3rd floor of Ronald Ross Building within the comp
2025_WBPWD_871418_1
WBPWD/EE-I/KSHED/Q33/25-26
Open Tender
A/C ORG
Item Rate
45 days
SSKM Hospital Kolkata
Please refer tender documents
4 documents required · 4 mandatory
₹15,180
O/o The Executive Engineer Kolkata South Health El
8 Sept 2026
28 Jun 2025
12 Jul 2025
28 Jun 2025
10 Jul 2025
4 Jul 2025
3 Jul 2025
Amount
Part: A (Electrical Installation Work):
Dismantling the existing damaged BDB, switch board, wiring, cable, fittings & fixture as required very carefully & carrying the same to safe place as per direction of EIC.
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC conduit (rigid) (Precision make) incl. necy. PVC clips, fittings etc.
4 x 10 & 2 x 6 mm² for Timer DB to Loop Box and Loop Box to AC ODU Terminal.
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
4 x 10 & 2 x 6 mm² cu. Wire.
Supplying & fixing of PVC cable end loop box of size (270 x 225 x 135 mm) including providing drilled holes incl all necessary items as required for the input power of ODU of AC System. (Make: Syntex) (Model No.: GSJB 3126)
Supply & Fixing of MCB Mounting CHANNEL WHITE – Din 35 Rail (35 x 7.5 x 0.8 mm) White plated in the existing PVC loop box including providing drilled holes incl all necessary items as required for the fixing of MCB Isolator.
Supplying and fixing 240/415 V 4 Pole 63 A MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand)
S & Laying 1.1KV gr. 4 Core 25 mm² XLPE Ar./Al. Cable (Make:- Gloster/Havells/Polycab as approved by EIC) incl. making connections as per direction of EIC.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting
S&F compression type gland complete with Brass Gland, Rubber Rings for dust & moistureproof entry of cables incl. finishing the ends by crimping method incl. S & Fixing Dowells solderless socket, tapes and jointing materials as follows;-
a) 4 Core 25 mm²
Part: B (SITC of Airconditioning System):
S&D of minimum 16.5 KW /5Tr.nominal cooling capacity ceiling suspended [concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor for fixed Speed Machine / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories complet with refrigerent (Make : DAIKIN / Mitsubishi ELectric / O General/ Mitsubishi Heavy).
Supply & Errection of ODU unit of AC system of deep fabrication to suitable MS angle, flats, U channel, Support, Pati for Base, Bar and the section welded mech Pati suitable for fixing on wall covering the existing ODU unit of AC system. IDU hanging from prefabricated structure by 2 Nos. MS Angle (35x35x6mm) of length 5.6 ft (Approx) including necessary holes fixing by fasteners for One No IDU Unit. All should be stereadly and electrically welded in a measurement and also the system have 1 No. door palla made of 25mm x 6 mm flat and 35x35x6mm angle (column & vertical) for Maintenace & Breakdown works of the ODU unit of AC system. AC Outdoor Unit Main Platform and Guard structure should be made of 75x40x6mm U channel, 50x50x6mm flat for base, 40x40x6mm angle, 25x3 mm Pati, 1/2" x1/2" Bar etc. All MS Fabrication Structure will be complete in a compact position finally the protection should be painted with moisture proof red oxide primer & approved paint (2 Coat) incl. carrying charges with lock & key arrangement . Base area of the platform will be as per Machine configeration & load with adequate service access for two nos. IDU & ODU Unit as per direction by EIC.
Supply & fixing of HVAC grade copper pipe of following sizes with Nitril Rubber insulation minimum thickness 9 mm. for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):-
(a) 3/8" (liquid line).
(b) 3/4" (gas line).
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 6 Core 2.5 sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells/Gloster)
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5 sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havell/Glosters)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector,6 mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
With out angle iron support
100x50x1.25mm (18SWG)
Supply & laying of 32 mm dia PVC Drain Pipe (Medium) including S&F necessary fittings (Make: Supreme/ Oriplast/ Finolex)
Supplying, fitting & fixing in position suspended boxing for return /supply air arrangement for ducting with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel(ACP) of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.( out door type make Aludecor/Armstrong)
a) Drop Celing
b) Trap Door
Supply & Fixing of double canvas connection [Make - Systemair / Air Enterprise / Premire / Caryaire / Airmaster].
Supply & Fixing of Aluminium powder coated Linear Contineous Grill [Make - Systemair / Air Enterprise / Premire / Caryaire / Airmaster].
(Less Cost: Unservicable Dismantled Materials: Rs. 4000.00)
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
M/s Singh Electrical Works (BID ID -6683658)
SUMAN ENTERPRISE (BID ID -6688292)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .