| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.4 L+₹3.7 L (14.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹31.5 L+₹5.8 L (22.4%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.4 L+₹8.7 L (33.8%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC L4 | |
| 5 | L5₹35.7 L+₹9.9 L (38.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹53 L
EMD Value
₹1.0 L
Closing Date
21 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A P Singh, IDSE,SE
HQ CWE Chandimandir
CA NO CWE/CHM(U)-27/2020-21 REPAIR AND MAINT OF EXTERNAL ELECTRIC DISTRIBUTION OF HIGH TENSION NETWORK HT UG CABLES AND ALLIED WORKS AT MD ACCN AREA AT CHANDIMANDIR MIL STN
2020_MES_355337_1
CWE/CHM(U)-27/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class C, Cat b(ii)
7 documents required · 7 mandatory
₹1,000
Yes
GE (U) Chandimandir
₹1.0 L
Yes
18 Sept 2020
24 Jun 2020
23 Jul 2020
24 Jun 2020
21 Jul 2020
8 Jul 2020
60 days
Amount
Disconnecting and taking out existing defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Taking out old damaged pre stressed concrete pole of any size incl breaking PCC foundation and clearing the site complete all as specified and directed.
Taking down old rusted cross arms/anti climbing devices incl clamps, nuts/bolts etc complete all as specified and directed.
Taking down old unserviceable HT insulators of any size and type complete all as specified and directed.
Disconnecting and taking out feeder pillar box of any type and size complete all as specified and directed.
Taking down old burnt HT jumpers of any size/type complete all as specified and directed.
Taking down old unserviceable HT GOD of any size/type complete all as specified and directed.
Taking out old unserviceable rubber mats of any size and type complete all as specified and directed.
Taking down old broken cable route indicator of any size/type complete all as specified and directed.
Taking down old unserviceable HT lightening arrestors of any size/type complete all as specified and directed.
Taking down old unserviceable installation sign board of any size/type complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping including provision of necessary form work complete all as specified and directed.
M&L GI tubes 80 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
All as per item No 15 here-in-before but 100 mm dia.
S&F in replacement operating handle for outdoor type HT 11 KV GOD switches complete all as specified and directed.
S&F gang operated air break switches with vertical isolation complete with drop out fuse unit assembly , triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for capacity 400 Amps, 11 KV complete with GI operating pipe of heavy duty grade of suitable length and bore complete all as specified and directed.
All as per item No 18 here-in-before but of rating 200 Amps.
M&L acrylic sheet milky white colour 3 mm thickness cut to required size for sign boards complete all as specified and directed.
M&L galvanised sheet 0.5 mm thickness cut to required size and fixed complete all as specified and directed.
M&L MS angle iron/MS flat of various sizes cut to required size for frame work/stands of sign boards including welding, drilling holes, bending etc complete all as specified and directed.
M&L vinyl sheet duly cut with computerised capital english letter /numbers/arrows etc and pasted using best quality adhesives complete all as specified and directed.
M&L for 20 watt LED tube light fittings complete with batten with and including LED tube light of capacity 20 watt complete all as specified and directed.
M&L aluminium angle of size 25 mm x 25 mm and 1 .5 mm thickness , for frame work cut to required size including drilling holes, bending etc complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for making HT cable route indicator of size and shape as directed incl wririting work , duly fixed in ground complete all as directed. Note :- Reinforcement shall be measured and paid separately.
M&L for TMT bars 8-10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
M&L in repairs GI strip 32x6 mm and connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structures complete all as specified and directed.
M&L for servicing of the outdoor type HT 11 KV 200 amps/400 amps capacity gang operated air break switch mounted on HT two pole/four pole structure by properly adjusting the mountings for ON/OFF operation by working from ground level, adjusting the length of operation rod ,lubricating the moving parts, tightening of all nuts/bolts, checking of all jumper connections for proper contact of male/female contacts, replacing worn out spares and testing for proper working complete all as specified and directed. Note:- Spare parts will be measured and paid separately.
Supply only moving contact blade (male contact) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified.
Supply only post insulators suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only moving contact blade (male contact) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only post insulators suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
M&L anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps made to shape to suit the size of the pole complete all as directed.
S&F in trenches, ducts or fixing along the poles or passing through pipes and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 95 sqmm 3 core, 11 KV earthed, complete all as specified and as directed.
All as per item No 41 here-in-before but 120 Sqmm 3 core.
All as per item No 41 here-in-before but 150 Sqmm 3 core.
All as per item No 41 here-in-before but 185 Sqmm 3 core.
All as per item No 41 here-in-before but 240 Sqmm 3 core.
Excavation in trenches in any type of soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth; for laying of cable,poles etc. and getting out complete all as specified and as directed.
All as above but depth exe 1.5 mtr and not exe 3.0 mtr complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and as directed.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm complete all as specified and directed. Make- Suryakirn/Mehtab or ISI marked as approved by GE.
M&L dry sand filling under and around UG cable to provide cushioning complete all as specified and directed.
S&F HT heat shrinkable type outdoor end termination cable jointing kit sutable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 52 here-in-before but of size 120 to 185 Sqmm.
All as per item No 52 here-in-before but of size 240 sqmm.
S&F HT heat shrinkable type indoor end termination cable jointing kit suitable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 55 here-in-before but of size 120 to 185 Sqmm.
All as per item No 55 here-in-before but of size 240 sqmm.
S&F HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed.
All as per item No 58 here-in-before but of size 120 to 185 Sqmm.
All as per item No 58 here-in-before but of size 240 sqmm.
S&F in repairs DC power pack with battery back up , input 230 volts AC and output 24 volt DC , capacity 100 watt 4 amps complete with operation indicators , terminal block, safety fuse etc and making connections with the existing circuits in HT VCB panels complete all as specified and directed. Make :- ALAN type APP230024 or equivalent make as specified in Appx 'B'.
S&F in replacement voltage transformer ratio 11 KV/110 volts confirming to IS-3156 1992, 50 Hz, class B insulation with primary voltage 11 KV/RT3 and secondary voltage 110 V/RT3, 50 VA, class 1.0 3P, type phase to earthcomplete incl making all connections complete all as specified and directed. Make - AE/Gemini/Jyoti or equivalent make as specified in Appx 'B'.
S & F in repairs breaker opearting (spring charging & ON/OFF) mechanism system as per existing suitable for 11 KV RMU SF-6 breakers of any make complete all as specified and directed.
M&L cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one coat of primer, one under coat and one finishing coat of aluminium paint complete all as directed.
Supply, installation,commissioning and testing outdoor type floor mounting double door feeder pillar box of size not less than 1300 x 1500 x 500 mm , fabricated from 3.15 mm thick CRCA sheet, 04 nos legs 500 mm long made from 50 x 50 x 6 mm angle iron , dully painted with two coats of synthetic enamelled paint over a coat of red oxide primer, dust/water and water proof , grouted in PCC 1:2:4 type B-1 foundation as direcetd, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete with and including the following:-
[a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 600 amps - 01 set. [b] MCCB FP 400 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Incoming). [c] MCCB FP 100 amps , 415 volts, 50 Hz, 25 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No and MCCB FP 63 amps , 415 volts, 50 Hz, 25 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 06 No (Outgoing). [d] Digital multifunctional meter of size 96x96 mm flush mounting type - 01 No, LT CTs ratio 400/5 amps - 03 Nos, LED RYB indicators - 03 Nos, control wiring with single core copper cable FRLS of suitable size incl control MCB for each circuit complete. [e] Earthing terminals - 02 Nos and danger notice plate - 01 No.
All as per item No 65 here-in-before but with and including the following :-
[a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 1200 Amps - 01 set. [b] ACB FP 800 amps , 415 volts, 50 Hz 01 No (Incoming) Note :- ACB shall be taken down from the existing LT panel board and refixed in the new panel board. [c] MCCB FP 400 amps , 415 volts, 50 Hz, 50 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No and MCCB FP 250 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Outgoing). [d] Digital multifunctional meter of size 96x96 mm flush mounting type - 01 No, LT CTs ratio 480/5 amps - 03 Nos, LED RYB indicators - 03 Nos, control wiring with single core copper cable FRLS of suitable size incl control MCB for each circuit complete. [e] Earthing terminals - 02 Nos and danger notice plate - 01 No.
Disconnecting the electrical supply, disconnecting incoming/outgoing cable connections & earhing connections, taking out the existing transformer of capacity 200 KVA to 500 KVA from the sub station building using crane of suitable capacity and shifting the same to another site , reinsatlling as directed, making all incoming/outgoing cable connectios and testing for satisfactory working complete all as directed. Note - All T&P, vehicle for transportation of the transformer, crane etc shall be arranged by the contractor and unit rate quoted shall be deemed to include the cost of the same.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with aluminium conductor of size 10 sqmm 2 core in trenches/ducts/through pipes/under culverts etc complete incl taking out the old burnt cable all as specified and as directed.
M&L pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as directed.
M&L single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as directed.
S&F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified. Note:- Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
M&L for repairing/maintenance/servicing of HT 11 KV VCB along with CTs/PTs of capacity upto 1250 A of any make and type by drawing out breaker from panel and servicing/ Inspecting/checking of automatic safety shutter operation for serviceability and adjusting for proper operation, checking of cross bar assembly, fixed contacts and current carrying parts of the breaker , cleaning/decarbonizing of all fixed and moving contacts, levers, springs, etc with soft emery paper , CRC solution and soft dry cloth to remove all carbon deposits and tightening all screws, nuts, bolts, spring etc and incl applying superior quality petrolium jelly on all contacts, checking of safety/tripping relays and wiring circuits, checking, setting and adjustment of rack in/rack out , spring charging system and operation of the breaker trolley, lubrication and greasing of breaker operating mechanism , all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear etc, checking of all end terminals, tightening of all earth connections, tightening all hardware, rack-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning:-
Note:- (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape etc. and testing and commissioning all as specified and as directed by the Engineer-in-Charge. (ii) Servicing/maintenance of VCBs shall be carried out by auhtorised service centre /agency/rep of any SEB as approved by GE.
Servicing/maintenance of ring main unit (RMU) 3/5 way 11 KV of any make , by disconnecting the power supply, visual inspection , general cleaning of the unit using blower/soft cloth, cleaning of all the contacts/bus bars etc with CRC solution and fine emery paper and removing all carbon deposits due to flashings, applying superior quality petrolium jelly on all contacts, checking and tightening all hardwares, checking all components/insulators/studs, adjusting male/female bushings in proper spacing, checking suitability and correct operation of protections, control instruments and electrical connections of the circuit breaker operating mechanism , verification of wiring circuits, lubricating all moving parts, checking/raparing and properly adjustment of opearting system, checking operation of functional locks, interlocks, signalling devices and auxiliary devices, measurement of the resistance of the main circuit , checking for any gas leakage , making all HT supply connections and testing complete all as directed.
Supply and fixing in repairs tripping coil/closing assembly 24 volts DC suitable for 11 KV HT VCB of any make and as per existing size/type complete all as specified and directed.
Supply only rack in rack out handle as per existing size, type and suitable for 11 KV VCB of any make/type complete all as specified and directed.
Supply only spring charging handle as per existing size, type and suitable for 11 KV VCB of any make/type complete all as specified and directed.
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and onventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as directed.
S&F lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as directed.
M&L chequered rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness complete all as specified and directed.
Supply and fixing in repairs spring loaded tulip contact, suitable for 800 amps 11 KV HT VCB of any make/type complete all as specified and directed.
Supply and fixing in repairs spring loaded tulip contact, suitable for 1250 amps 11 KV HT VCB of any make/type complete all as specified and directed.
S&F in replacement three phase digital type voltmeter with input 0-110 VAC and range 0-11 KV AC , accuracy ± 1.0% ,PTR 11 KV/V3/110V/V3 , square shape size 96x96 mm , flush mounting type ,on the HT 11 KV panel boarrds at various locations all as per existing incl making all connections with control wiring and testing for proper working complete.
Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
Cutting wild grass,bushes shrubs etc and cleaning of area/yard of sub station buildings complete all as directed by Engr-in-Charge
S&F jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc all as specified and directed.
M&L for preparing the surfaces for repainting by removing dust/rust etc and painting of old steel tubular poles 11 Mtr long alonwith cross arms / clamps etc with two coat of aluminium paint over a coat of red oxide primer all as specified and directed. Note:- Poles alongwith cross arms fixed as two pole or four pole structures shall also be measured and paid under this item only.
Supply and fixing in repairs door handle kit suitable for HT VCB 11 KV 630/800/1250 amps capacity of any make, for proper locking of the main door complete all as directed.
S&F in replacement HT current transformer suitable for 11 KV HT VCB of any make , having ratio 400/200-5 amps or 300/150-5 amps or 200/100-5 amps accuracy class 1.0 5P10, 10 VA, 50 Hz incl making alll connections complete all as specified and directed. Make:- Jyoti electricals/AE/Gemini/Ereva or equivalent make as specified in Appx 'B'.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
S&F in replacement electric motor 230 volts AC suitable for operating mechanism of HT 11 KV VCB of of any make/type complete all as per existing and testing for proper functioning all as directed.
S&F in replacement three phase digital type ammeter with input 0-5 AAC and range 0-200 AAC , accuracy ± 1.0% , square shape size 96x96 mm , flush mounting type ,on the HT 11 KV panel boarrds at various locations all as per existing incl making all connections with control wiring and testing for proper working complete all as directed.
Laying only in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11 KV grade and size 95 sqmm 3 core to 240 sqmm 3 core complete all as specified. Note - HT cable shall be issued under Sch 'B' free for fixing.Earth work/cable cover/ sand etc shall be measured and paid separately under respective items.
M&L bricks for cable protection laid flat complete all as directed.
S&F in repairs HT 11 KV barrel fuses along with fuse element and metal parts suitable for up to 100 amps capacity complete all as specified and directed.
All as per item No 94 here-in-before but from 100 amps to 200 Amps.
Supply and fixing in repairs space heater 240 volts single phase as per existing size/type and suitable for 11 KV VCB of any make complete all as specified and directed.
S&F in repairs LED indicators on the existing HT 11 KV panel boards all as per existing size/colour all as direccted.
Only laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 185 sqmm 3.5 core to 300 sqmm 3.5 core in trenches/ducts/ through pipes/under culverts etc complete incl taking out the old burnt cable all as specified and as directed. Note - LT cable shall be issued under Sch 'B' free for fixing from MES store yard. Earth work/bricks /sand etc shall be measured and paid separately under respective items.
All as per item No 98 here-in-before but size 400 sqmm 3.5 core. Note :- LT cable shall be issued under Sch 'B' free for fixing. Earth work /brick/sand etc shall be measured and paid separately under respective items.
M&L for rewiring of the complete control circuits of 11 KV HT VCB of any make with single core copper conductor cable of size as per existing for metering/safety relays/indicators/charging system/tripping closing wiring circuits/ connections from CTs,PTs/cubical lamp & socket/thermostat & space heater/Dc power supply system for relays etc incl numbering ferrules for marking complete all as specified and directed.
Supply and fixing in repairs copper connection for C.T. With nut, bolt and double washers for 11 KV VCB of any make all as per existing complete all as directed.
S&F in repairs HT current transformer suitable 11 KV HT RMU having ratio 200-100/1 A, burden 4 VA, 50 Hz , Class 5P, accuracy level factor 10 complete making all connections and testing for proper working all as specified and directed.
Supply and fixing in repairs thermostat for space heater , single phase range 0 to 90 degree celcius all as per existing size/type and suitable for 11 KV VCB of any make complete all as specified and directed.
Disconnecting and taking out protection relays/trip relays of any make and any type from HT panel boards , cleaning all the contacts properly, calibrating the relays by conducting secondary injection tests, checking of current transformers, checking the complete wiring circuits and rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relays, reinstallation of relay into the system, making all connections, testing & commissioning complete all as specified and directed.
M/S BALWINDER SINGH
Raman Electric Trading Co
R D Bansal
KATWAL TECHNOCRATS
Bharat Enterprises
R N Enterprises
Vee Vee Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .