Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | ₹35.5 L Quoted ₹35.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹37.1 L+₹1.4 L (3.94%)Rejected-Finance | ₹37.1 L+₹1.4 L (3.94%) | L2 | Rejected-Finance Higher bidder |
| 3 | L3₹40.6 L+₹4.9 L (13.8%)Rejected-Finance | ₹40.6 L+₹4.9 L (13.8%) | L3 | Rejected-Finance Higher bidder |
| 4 | L4₹41.7 L+₹6.1 L (17.0%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹41.7 L+₹6.1 L (17.0%) | L4 | Rejected-Finance Higher bidder |
| 5 | L5₹42.2 L+₹6.5 L (18.3%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | ₹42.2 L+₹6.5 L (18.3%) | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
29 Jun 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO BUILDING NO P 16 310 DET AT INS HANSA UNDER GE NW VASCO
2021_MES_445779_1
85348/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹74,000
Yes
31 Aug 2021
25 May 2021
1 Jul 2021
25 May 2021
29 Jun 2021
22 Jun 2021
Amount
Schedule 'A' Part I - B/R portion
Taking down/out loose & damaged concrete/cement plaster from soffits of ceilings, floor/roof slabs, vertical surfaces of columns, beams etc., including exposing and removing rust from the reinforcement by rubbing with wire brush and removal of debris to a distance not exceeding 100 m and depositing where directed
M&L for gunniting exposed concrete surfaces of beam, column and slabs with one layer of complast spray set modified concrete in proportion (50Kg cement 3 to 6mm granite chips 75 kg zonal sand 75 kg and complast 2% by weight of cement to the following locations :-
(a) 40 mm thick in columns
(b) 30 mm thick in beams
(c) 20 mm thick in slabs
S&F Hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exc. 4 Kg/sqm complete all as specified and as directed
Bonding the entire exposed surface with one coat of SBR as per manufacturer instructions over wire fabric and surfaces of concrete structure complete all as specified and as directed
Supply only water proofing compound complete all as specified and as directed
Dismantling/Taking out existing hessian base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engr-in -charge.
M&L for providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Apply two coats of acrylic polymer based flexible cementitious elastomeric membrane of approved make of about 1 to 1.5 mm dry film thickness over a coat of primer as per manufacturer's instruction over roof slab etc and as per manufacturer's specifications. NOTE - Water proofing treatment shall be carried out through authorized applicator of manufacturer.
Demolition of brickwork or block/ boulder masonry, laid in cement mortar complete all as specified and as directed
M&L for pre-cast cement concrete block masonry type C-5 with solid blocks, exc. 10 cm in width and setting in mortar complete all as specified and as directed
Taking down cement plaster on brick or stone walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed
M&L for rendering 15 mm thick on block masonry surfaces or other than fair faces of brick work in cement mortar 1:4. finished to even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with 3% integral water proofing compound finished to even and smooth without using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately.
M&L for rendering 5 mm thick cement plaster on ceiling in cement mortar 1:3 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately.
M&L for complete removal of existing treatment and preparing old plastered ceiling surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for preparing new plastered ceiling surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for complete removal of existing treatment and preparing old plastered wall surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for preparation of old/new plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
Dismantling floor/wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed
M & L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing/pavings/plinth protections, etc complete all as specified and as directed
M&L for screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces to receive glazed tiles complete all as specified and as directed
M&L for vitrified ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for vitrified ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for vitrified ceramic tiles of dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed
M&L for granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
M&L for non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed
Taking down chowkhat or frames not exceeding 1.5 sqm each without taking of shutters from the frame complete all as specified and as directed
Taking down chowkhat or frames exceeding 1.5 sqm but not exceeding 4 sqm each without taking of shutters from the frame and removing to store complete all as specified and as directed
S&F Factory Made Solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelam PVC Sheet on the front face & 2mm pre lam PVC sheet on back face, including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site complete all as specified and as directed
S&F Factory made 100% solid wood plastic(WPC) decorative door frame, single rebate of size 95mm x 45mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and as directed.
S&F Butt hinges medium weight stainless steel 100mm size complete all as specified and as directed
S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm grip size complete all as specified and as directed
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size complete all as specified and as directed
S&F Door closer hydraulically regulated, aluminium extruded body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed
S&F Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed
S&F Powder coated aluminium door/window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured inclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed
S&F Solar control film 50 micron reflective type mirror finish/mirror jet black type complete all as specified and as directed
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified and as directed
All as per Item No.45 here in before but of 25 or 32 mm dia complete all as specified and as directed
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed
All as per Item No.47 here in before but of 25 mm dia complete all as specified and as directed
All as per Item No.47 here in before but of 32 mm dia complete all as specified and as directed
S&F in repair angular stop cock of 20 mm dia with wall flange complete all as specified and as directed
S&F in repair table top basin of size 500 x 420 x 190 mm with fixing accessories set complete all as specified and as directed
S&F in repair two way bib cock with wall flange complete all as specified and as directed
S&F in repair central hole basin mixer with Regular Spout without popup Waste system with 450 mm long braided hoses complete all as specified and as directed
S&F in repair overhead shower of 200 mm dia round shape single flow (body and face plate brass with chrome plated) with rubit cleaning system complete all as specified and as directed
S&F in repair wall mixer with provision for overhead shower with 115 mm Long bend pipe on upper side, connecting legs & wall flanges complete all as specified and as directed
M&L for cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75 mm dia complete all as specified and as directed
S&F in repair flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and as directed
S&F in repair bowl for coupled WC with PP soft close seat cover, hinges, accessories set, of size 375 x 650 x 800 mm along with cistern and its fitting complete all as specified and as directed
S&F Hand shower (Health faucet) dia 8mm 1 m long flexible tube and wall hook complete all as specified and as directed
S&F in repair toilet paper holder recessed type (stainless steel) complete all as specified and as directed
S&F in repair towel rack 600 mm long with Lower Hangers, stainless steel complete all as specified and as directed
S&F in repairs soap dish, of material brass with glossy finish complete all as specified and as directed
S&F in repair urinal (Top inlet) with fixing accessories set of size 475 x 300 x 715 mm complete all as specified and as directed
S&F Metro pole flush valve regular of 32 mm size (concealed body) with exposed shut off Provision and Round Flange complete all as specified and as directed Note for Item Nos.50 to 64 : Make shall be as per Appendix-'B'
S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed
Dismantling of cast iron/AC drain pipes jointed in cement mortar complete all as specified and as directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed
S&F 18 mm thick single side pre laminated wood grain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications.
Schedule 'A' Part II - Internal Electrification
Taking down carefully any type of copper/ aluminium point wiring (light, fan, socket or power) complete including conduits/casing capping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per Item No 75 here in before, but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 75 here in before, but for one bell point controlled by one bell push complete all as specified and as directed.
All as per item No 75 here in before, but for one 3/5 Pin, 5 Amp switch socket out let on the independent board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with four runs of single core 10 Sq mm FR-LSH copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as tees, elbows, junction boxes etc, as required fixed concealed in wall along with two runs of 10 Sqmm single core FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Six runs of 10 sqmm cable and one run of PVC conduit shall be measred as one unit length
M & L for sub main wiring with four runs of single core 6 Sq mm FR-LSH copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as tees, elbows, junction boxes etc, as required fixed concealed in wall along with two runs of 6 Sqmm single core FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Six runs of 6 sqmm cable and one run of PVC conduit shall be measred as one unit length
M & L for sub main wiring with two runs of single core 6 Sq mm FR-LSH copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as tees, elbows, junction boxes etc, as required fixed concealed in wall along with one run of 6 Sqmm single core FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Three runs of 6 sqmm cable and one run of PVC conduit shall be measred as one unit length
M & L for sub main wiring with two runs of single core 4 Sq mm FR-LSH copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as tees, elbows, junction boxes etc, as required fixed concealed in wall along with one run of 4 Sqmm single core FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Three runs of 4 sqmm cable and one run of PVC conduit shall be measred as one unit length
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular bell push,flush type, 6 Amps complete all as specified and as directed.
S & F in repairs modular switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F in repairs modular socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F in repairs call bell AC, 230 Volts single pole,ding-dong sound type complete all as specified and as directed.
S & F in repairs fan step regulator, 120W - 2 module complete all as specified and as directed.
Taking down unserviceable any type of main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
S&F in repairs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one MCB SP 20 Amps, 10 KA 'C 'series, 240 Volts complete all as specified and as directed.
S & F MCB DB TPN 4 way DB 415 V with 200 A rated bus bar double door type complete all as specified and as directed.
S & F MCCB DB TPN, 4 way, (MCCB + 24 way O/G) double door, vertical type icluding one MCCB of 100 amps breaking capacity 25 KA, 4 pole without MCB complete all as specified and as directed
S&F MCCB of 100 to 125 A breaking capacity 25 KA , 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed
S&F MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
S & F MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 m from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. Note:GI wire 4 mm is upto 7.5m length is deemed to be included under quoted rate
Taking down carefully ceiling fans of size 1200 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of accessories such as ball bearings, gun metal bushes, capacitor, canopy top& bottom, shackle clip assembly and assembling of all parts and painting with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour, including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance after renovation of bldg complete all as specified and directed. (Note:- After taking down fan will be in contractor custody to keep in safe condition.)
All as per Item No. 104 above, but exhaust fan of size up to 300 mm and 380 mm sweep complete all as specified and as directed.
S & F in repairs energy efficient surface mounted LED luminaire 20 watts , with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approximate length 0.5 mtr complete all as specified and as directed.
S & F in repairs recess mounting high lumen LED flat panel 2'X2' 40 Watt, white powder coated CRCA housing with high power LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
S & F in repairs recess mounting high lumen LED flat panel1'X1' 18 Watt, white powder coated CRCA housing with high power LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
S&F in repairs LED light fitting 1x18 watts surface mounted LED down lighter in powder coated white finish with integrated electronic driver complete all as specified and as directed.
S & F in repairs Energy efficient surface Mounted LED Luminire10 watts 2' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 m complete all as specified and as directed.
S&F in repairs energy efficient LED building security light luminaire 72 watts capacity comprises a die cast aluminium housing including connections with two runs of 2.5 sqmm aluminium unsheathed wire multi stranded from LT over head line / junction box to the connector of fitting (connection wires shall not less than 2.5m in length duly run through GI bracket) complete all as specified and as directed.
M & L for Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed.
Dismantling carefully the existing window type AC 1.5/2.0 TR capacity from its position, keep in safe custody and refixing in serviceable condition after renovation of bldg including necessary gas filling complete all as specified and as directed.. (Note :- After taking down ACs will be in contractor custody to keep in safe condition)
Dismantling carefully the existing split type AC (indoor & outdoor unit) 1.5/2.0 TR capacity from its position, keep in safe custody and refixing with new bracket and in serviceable condition after renovation of bldg, including gas filling complete all as directed. (Note :- After taking down will be in contractor custody to keep in safe condition)
S & F in repairs copper pipe for discharge 5/8'' & 3/8" dia complete for split Acs complete all as specified and as directed..
S & F in repairs copper pipe for suction 1/2'' & 1/4" dia complete for split Acs complete all as specified and as directed.
Schedule 'A' Part III - External Electrification
Taking down old unserviceable cable of any core and any size from any description complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 95 sq mm 3.5 core all as specified and as directed Note:Excavation, PCC cable cover and Sand for cushioning shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth getting out in hard/dense soil and levelling of bottom surface to required level for laying of UG cable complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth getting out soft/disintegrated rock and levelling of bottom surface to required level for laying of UG cable complete all as specified and as directed
Removing excavated material from site to a distance not exceeding 50 m away and depositing where directed not exceeding 1.5 m from starting point complete all as specified and as directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated material complete all as specified and as directed
Supply and laying in trenches clear sand for cushioning under ground cable 8cm below and 15 cm above complete in level complete all as specified and as directed Note: Punned thickness shall be measured and paid.
Supply and lay PCC cable cover class LV, type I, flat size 250mmx150mmx40mm in trenches to protect under ground cable complete all as specified and as directed
S& F GI pipe light grade of 80 mm bore ISI marked including all fittings on wall or laid in floors as required positionor GI tubing 80 mm dia light grade for protection of UG cable complete all as specified and as directed
M/s RAJ CONSTRUCTION
OM SAI ELECTRICALS
M/S jvsr constructions
M/S P S BABU
M/S. M M S ENTERPRISES
M/S G.N.POWAR
M/S Kartik Enterprises
K M Subhanaiah
M/s Gayatri Contruction Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .