Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹1.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹15.2 L (11.5%)Rejected-Finance | ₹1.5 Cr+₹15.2 L (11.5%) | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
28 Dec 2019, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF COMMUNICATION AND AFNET ROOMS ALONGWITH ASSOCIATED SERVICES FOR E/M AND B/R AT AF STN CHIMNEY HILLS, BANGALORE
2019_MES_263130_4
82065
Open Tender
Civil Works
Lump-sum
365 days
Chimney hills
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
AGE(I)(AF) Chimney Hills
₹2.0 L
Yes
28 Jan 2020
28 Nov 2019
30 Dec 2019
28 Nov 2019
28 Dec 2019
11 Dec 2019
28 Nov 2019 - 4 Dec 2019
Amount
GENERALSUMMARY Note : Schedule ‘A’ Part I to XI are prepriced by MES under Ser No. 2 to 11.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building Work” as listed in Schedule ‘A’ Part-I representing **______________% (_______________________)* above/below the lumpsum price of Rs 3846000.00 inserted by MES for Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–II A representing **______________% (_______________________)* above/below the lumpsum price of Rs 92763.70 inserted by MES for Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–II B representing **______________% (_______________________)* above/below the lumpsum price of Rs 24830.00 inserted by MES for Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–III representing **______________% (_______________________)* above/below the lumpsum price of Rs 4970.20 inserted by MES for Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for “FOOT PATH” as listed in Schedule ‘A’ Part–IV representing **______________% (_______________________)* above/below the lumpsum price of Rs 94738.00 inserted by MES for Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for “ Sewage Disposal” as listed in Schedule ‘A’ Part–V representing **______________% (_______________________)* above/below the lumpsum price of Rs 46736.21 inserted by MES for Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for “Area Drianage” as listed in Schedule ‘A’ Part–VI representing **______________% (_______________________)* above/below the lumpsum price of Rs 54053.38 inserted by MES for Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for “SITE CLEARANCE ” as listed in Schedule ‘A’ Part–VII representing **______________% (_______________________)* above/below the lumpsum price of Rs 21276.36 inserted by MES for Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–VIII representing **______________% (_______________________)* above/below the lumpsum price of Rs 159813.40 inserted by MES for Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part–IX representing **______________% (_______________________)* above/below the lumpsum price of Rs 471110.73inserted by MES for Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part–X representing **______________% (_______________________)* above/below the lumpsum price of Rs. 62300.80 inserted by MES for Schedule 'A' Part-X.
SCHEDULE `A' PART - XI Miscellaneous items is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply and Fix surface and wall mounted LED batten 22 W with Lamp , extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver etc. complete including lamp with all accessories internally prewired and icluding connecting up with 1.0 sqmm three core flexible copper conductor cable all as directed ( Make : Havells Cat No ENDURA LINEAR NEO BS22WLED865SPCWH or equivalent in make Crompton Greaves / Phillips/Bajaj Wipro
Supply and Fix surface and wall mounted LED batten 1x10 W with Lamp , extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver etc. complete including lamp with all accessories internally prewired and including connecting up with 1.00 sqmm 3 core flexible copper conductor cable all as directed ( Make and Model No for Batten : Havells Cat No ENDURA LINEAR NEO BS10WLED830SPCWH or equivalent in make Crompton Greaves / Philips/Bajaj Wipro
Supply & Fix ceiling fan copmlete and accessories 230 V,1200 mm sweep BEE 5 star rated all as specified and as directed. Make- Philips/Bajaj /Wipro /Havells
Supply and fix Exhaust fan, 300 mm sweep with louvre complete metal body , fixed to wall with suitable MS bolts, grouted to wall and connecting up including provision of 3 core cable from connector to fan with flexible copper conductor cable 24/ 0.2 mm complete all as specified and directed. Make:- Standard, Model Refresh air-SPS- Metal exhaust fan or its equivaqlent in CG/ Havells/Usha/Bajaj/Orient/Khaitan.
Supply and fix MCB DB TPN 4 way 415 Volts vertical type double door with 200 Amps bus bar and IP-43 ingress protection including 1 No MCCB 100 Amps TPN 25 KA rupturing capacity as incomer fixed to wall flush mounted including connecting up commissioning complete all as directed. (Make- legrand /ABB/ SIEMENS / Havells).
Supply & fix 'C' Curve MCB SPN 6 to 32 Amps 240 volts 10 KA rupturing capacity complete all as directed.
Supply & fix 'C' Curve MCB SP 6 to 32 Amps 240 volts 10 KA rupturing capacity complete all as directed.
Supply & fix 'C' Curve MCB TP 32 Amps 430 volts 10 KA rupturing capacity complete all as directed.
Supply, Install, testing and commissioning of SURGE PROTEVTION DEVICE (SPD) Three phase 3P+N-Max 20 KA Type iPRD20 with necessary connecting accessories. Make : Schneider Cat No A9L20600 or equvalent in Oblum / BHEL / GEC-ELPRO/ Crompton & Greaves/ AREVA T&D / Rashtriya/ Jaipuria / Elpro/ Atlas
S&F for 160 mm outer dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all all as specified and as directed.
Construction of 10 users Hume pipe septic tank designed to carry sewage and sullage water including excavation & earthwork in hard / dense soil ,PCC 1:4:8 below foundation , vent shaft, connection etc complete all as specified and as shown on drawings.
M&L for Soakage wells of size1.20M dia and 3.00M deep complete all as specified & shown on drawings
Supply and fixing commissioning & testing of LT Panel CPRI certified factory made powder coated cubical outdoor type floor mounted with canopy and ingress of protection IP 54 with sufficient working space and weather proof vermin proof febricated out of 3.14 mm thick CRCA sheet and 40x40x4 mm angle iron base frame fixed on and including foundation base PCC (1:3:6) type C1 and comprising of & including the following: (a) 4 Nos Bus bar of equal size of aluminium with PVC coloured heat shrinkable type sleeves, continous rating of 400 AMPs mounted on fibre reinforced insulator (b) MCCB 4 Pole 250 Amps 415 Volts 35 KA ------1 No (Incoming) (d) MCCB 3 Pole 100 Amps 415 Volts 25 KA -----3 Nos. (e) MCCB 3 Pole 63 Amps 415 Volts 16 KA -----2 Nos (f) Voltmeter Digital type 0 - 500 volts - 1 No (g) Ammeter Digital type o to 600 Amps with suitable CTs --- 1 No. (h) Indication lamp panel mounting complete with all fittings RYB - 3 Nos.
S&F 4 Pole MCCB 250 Amp ,50Hz, 415 V with rupturing capacity 35 KA with enclosure for incomming tapping point including making connections , all as specified and directed.
M&L for Earthing complete chemical type with copper earth plate electrode 900 mm x 600 mm x 5 mm thick buried directly in ground (Earth pit not less than 5.15 metres deep below ground level) with top edge of the plate not less than 4.25 mtr below normal ground level connected to and including copper strip lead 32 mm x 6 mm size by means of copper brazing strip and layers of salt, charcoal & magnesium sulphate including watering pipe, funnel and wire mesh including testing of earthing all as specified and as directed by Engineer-in-charge with & including the following :- (a) Earthing to be done in presence of Engineer -in-charge (b) Charcoal small pieces - 250 Kg, salt (crystal) - 250 Kg, Magnesium sulphate (crystal) - 100 Kg. (c) Copper strip shall be braced with copper plate electrode. (d) Alternate layers of charcoal and salts should be laid in the earth pit on the top of copper plate at least 5 layers should be laid. (e) After laying the 5 alternate layers of charcoal and salt a two layers of magnesium sulphate to be laid. (f) The chemical salt and magnesium sulphae should not be mixed but are to be laid in layers only. (g) The copper strip is to be extended inside the euipmentand power room it should be routed in the side wall of under ground ducts/ fixed with ceramics/porcelin spacers. (h) Contractor shall pour sufficient water in earth pit before and after doing earthing.(j) 25 mm dia GI pipe suitable legth ro reach just above copper plate fitted with funnel meshed along with cap and running water tap to be provided for keeping the soil wet. (k) Soft soil (Black cotton soil) shall be used in case of rocky terrain. (l) Brass nuts & bolts with proper washer to be used for copper strip jointing and necessary bracing shall be done as directed. (m) Copper strip & protection pipe beyond 7.5 m shall be measured and paid separately. (n) The test point pit shall be made as directed & the cost is deemed to be included in the quote rate. (o) The test report shall be submitted in triplicate (p) Construction of earth pit chamber PCC (1:3:6) type C1 (using 20 mm grade stone aggregate) RCC 1 : 2:4 cover 50 mm thick with 8 mm dia TMT bar 100 mm centre to centre with lifting handles of suitable dia complete all as directed by Engineer-in-charge Note :- Earth resistance to be less than 1 Ohms. 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost 3. Earth test point shall be measured and paid separately.
Supply, install, Testing & commissioning inverter type hi wall Split type Units indoor/out door complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown 220 volt- 240 volt 50 Hz of capacity 2 TR including following items complete all as specified and directed. (a) Copper tubing 24 SWG 3/8 inches & 5/8 inches dia of superior quality suitable for refrigeration suction/ discharge line along with tubular rubber insulation suitable for air conditioners. (b) HDPE drain pipe 20 mm dia fixed to wall on roof complete (c) Charging of refrigerent gas 410A / 407C as directed (d) Power supply cable suitable size for indoor & out door unit from stabilizer Make : Carrier /Voltas/ Bluestar / Daikin / Hitachi
Supply, install, Testing & commissioning inverter type hi wall Split type Units indoor/out door complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown 220 volt- 240 volt 50 Hz of capacity 1.5 TR including following items complete all as specified and directed. (a) Copper tubing 24 SWG 3/8 inches & 5/8 inches dia of superior quality suitable for refrigeration suction/ discharge line along with tubular rubber insulation suitable for air conditioners. (b) HDPE drain pipe 20 mm dia fixed to wall on roof complete (c) Charging of refrigerent gas 410A / 407C as directed (d) Power supply cable suitable size for indoor & out door unit from stabilizer Make : Carrier /Voltas/ Bluestar / Daikin / Hitachi
M & L for MS stand duly painted suitable for fixing 1.5/2.0 TR AC out door unit and fixed complete all as directed.
Supply and installed Voltage stabilizer automatic wall mounted type air cooled , single phase designed for input variation 170 volts to 250 volts and out put voltage stabilized at 230 volts + or - 2.5 % accuricy of capacity 4 KVA.
M&L for Sub main wiring complete with 2 runs of 4 Sqmm PVC Insulated and unsheathed cable with multi stranded FRLS copper conductor cable , ISI marked and drawn through and including PVC concealed conduit of suitable size ( not less than 25 mm dia size) as directed with its accessories fixed on walls floors/ ceilings etc and connecting terminal ends including 1 x 4 Sqmm PVC insulated unsheathed FRLS copper conductor stranded cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as directed. (Note: 4 runs of 6 sqmm FRLS cable + 2 run of 6 sqmm FRLS cable + 1 run of PVC non metallic conduit shall be measured as one running metre.
M&L for Sub main wiring complete with 4 runs of 6 Sqmm PVC Insulated and unsheathed cable with multi stranded FRLS copper conductor cable , ISI marked and drawn through and including PVC concealed conduit of suitable size ( not less than 25 mm dia size) as directed with its accessories fixed on walls floors/ ceilings etc and connecting terminal ends including 2X6 Sqmm PVC insulated unsheathed FRLS copper conductor stranded cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as directed. (Note: 4 runs of 6 sqmm FRLS cable + 2 run of 6 sqmm FRLS cable + 1 run of PVC non metallic conduit shall be measured as one running metre.
M.VENKATARAMANAPPA AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .