Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.9 L+₹3.3 L (12.9%)Rejected-AOC 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹30.3 L+₹4.7 L (18.3%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹30.4 L+₹4.8 L (18.8%)Rejected-AOC 84 POLO HILLS OPPOSITE SBI BRANCH EAST KHASI HILLS SHILLONG MEGHALAYA 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹32.2 L+₹6.6 L (25.8%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L5 | Rejected-AOC Rejected |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
12 May 2022, 6:00 pmClosed
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA No GE (I) (AF) /SHL/ OF 2022-2023 PROVN OF SHEDS, ADDN/ALTN TO BLDG NO SP-137 AND ADDN / ALTN TO TOILET AT SNCOs MESS AND PROVN OF CHAIN LINK FENCING AT VARIOUS LOCATIONS AT AF STN LAITKOR PEAK UNDER GE (I) (AF) SHILLONG
2021_MES_487670_7
8052/21/SHL/2021/22
Open Tender
Civil Works
Item Rate
180 days
LAITKOR PEAK SHILLONG
For Enlisted Contractors Class E Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I)(AF) SHILLONG
₹53,000
Yes
2 Jul 2022
28 Apr 2022
14 May 2022
28 Apr 2022
12 May 2022
30 Apr 2022
28 Apr 2022 - 29 Apr 2022
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
B/R ITEMS Surface excvation not exceeding 30 cm deep averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out in soft/loose soil complete all as directed. (17+8.2+5)
Excavation in post holes (or similar holes) in soft/loose soil, each n.exc 0.5 cum, getting out, returning, filling in and ramming moorum or broken rubble mixed with moorum in layers n.exc 25cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed. (22+16+100)
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick,complete, all as specified and directed.(7+6)
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified and directed . (6.75+0.39+26+1.2+11)
M & L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed. (1.24+10+0.8)
M & L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling under floor, in sunken floors etc complete all as specified and directed. (3.7+1)
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation, filling under floor, in sunken floors etc complete all as specified and directed.
M & L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. (8.04+0.08+2.5)
M & L for providing cement concrete 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains and benching including use and waste of formwork where necessary and finishing the exposed top surface of concrete even and smooth using extra cement complete all as specified and directed.
M & L for precast cement concrete block masonary with solid block 1:3:6 type C1 (using 20 mm graded agg) exc 10 Cm in width and setting in cement mortar 1:4 complete all as specified. (9.28+0.68+20+10.5)
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands copping/cills, bed block for embedding hold fast etc including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as directed . (3.5+1)
M & L Reinforced cement concrete M-25 (design mix) using graded stone aggregate as in foundation including rafters footings foundation beam plinth beam bases for column etc basement slab under reamed piles and mass concrete complete all as specified and directed.
M & L for Reinforced cement concrete M-25 (design mix) using graded stone aggregate as in columns, pillars, posts and struts etc complete all as specified and directed.
M & L for Reinforced cement concrete M-25 (design mix) using graded stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed by Engineer-in-Charge.(11.2+1)
Supply only integral water proofing liquid complete all as directed.
M & L for Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste of Form work to sides of square, rectangular or polygonal pillars, posts, columns etc for flat fair finished surfaces complete all as specified and directed.
M & L for Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. exc 200mm thick for flat fair finished surfaces complete all as specified and directed. (96+10)
S & F 150mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.(4+24)
S & F 100mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised sliding door bolts, plate type with bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as directed
S & F in repairs aluminium (Die cast) body, door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.(1830+120)
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete con- forming to Fe.290.Gde-E-165 complete all as directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F for rolled sections of Fe-410 W (Gde E-250) quality 'A' as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S & F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 (Gde E-165) complete all as specifed and directed.(34.32+5)
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed. (345.08+133.76+350)
S&F for rolled mild steel sections of Fe-410 W (Gde E-250) quality 'A' as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. including prepration of surfaces and painted with one coat of red oxide zinc chrome primer paint at Contractor’s workshop before fabricationand complete all as specified and directed. (1184.56+650)
M & L for mild steel work conforming to Fe-290 Gde E-165 as in hold fast of flat iron bands, straps, supports or stays for rain water, ventilating pipes cut to length, bend to shap including bolts if required and wall tie, clamps etc., and including preparing surfaces and treated with tar and sanded with clean sharp sand complete all as specified and directed.
S & F for mild steel screw bolts (purpose made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30cm long and dia of neck not exceeding 12mm complete all as specified and directed (5+12)
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) anodized aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium door shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, powder coated anodised aluminium snap beading, screws, powder coated aluminium fittings, such as handle (01 No for each leaf) etc complete all as specified and directed. (Note :- Glazing/wire mesh shall be measured and paid separately under respective items of Schedule.)
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium windows and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, powder coated anodised aluminium snap beading, screws, powder coated anodised aluminium fittings such as peg stays 150mm long (01 No. for each leaf), Butt hinges type B-21 100mm size (02 Nos for each leaf) & handle (01 No for each leaf) etc complete all as specified and directed. (7.2+1) (Note :- Glazing/wire mesh shall be measured and paid separately under respective items of Schedule.)
S & F for pre-painted galvalume aluminum zinc coating GI based trapizoidal profile steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions complete all as specified and directed.(203.37+100)
S & F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions completed all as specified and directed.(12+10)
S & F 0.63mm thick galvanised corrugated mild steel sheeting in with two corrugation side lap, fixed with 'L' type or cranked hook bolt using profiled GI washer and bitumen washer in roofs, walls etc with grade of Zinc coating 120 (Type-VIII) complete all as specified and directed.(4.03)
S & F for 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) fixed with 'L' type or 'J' type hook using profiled GI washer and bitumen washer in roofs, walls etc Zinc coating 120 (Type-VIII) complete all as specified and directed.(3.2)
S & F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in lieu of screw using profiled GI washer and bitumen washer in roof covering complete all as specified and directed.
M & L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as directed. (48+8)
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed. (54+7.5)
M & L vitrified ceramic tiles light shade 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
M & L for cement conctrete pre-polished chequered coloured paver tiles of size 305x305x25mm thick of approved colour and design as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for 60mm thick PVC moulded precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand and interstices on edges filled with PCC 1:2:4 type B-1 finished even and smooth without using extra cement complete all as directed.
M & L for rendering 5mm thick in CM 1:3 on concrete surface or on fair faces of brick surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.(72+8)
M & L for 15mm thick rendering in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed. (40+74)
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick masonry/concrete surfaces, mixed with water proofing liquid @ 150ml per 50 Kg bag of cement and finished even and smooth without using extra cement complete all as specified and directed. (Note :- Supply only Water Proofing Liquid shall be measured and paid separately) (61.88+6.9+95+40)
S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all specified and as directed. (5+1)
S & F 5.5mm thick sheet glass frosted on one side and glazing with oil putty in squares exc 0.5 sqm in each pane complete all specified and as directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling/soffits of chajjas complete all as specified and directed.(61.88+6.9)
M & L for preparing newly plastered walls surfaces and applying two coats of plastic emulsion paint over a coat of priming paints plaster coat over a coat of 1mm thick wall care putty complete all as specified and directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.) (60+38)
Material and labour for preparation of newly plastered surfaces of wall, applying a coat of 1mm thick wall care putty and applying two coats of weather proof acrylic paint over one coat of exterior grade acrylic primer complete all as specified and directed. Make-Apex Ultima of Asian, weather shield MAX of ICI/Dulux, weather coat long life of Beger, Acroguard 3X of Acro paint. (
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coat of red oxide zinc chrome primer complete all as specified and directed. (30+10.66+20+10+30)
E/M ITEMS M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS, including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H green colour cable as earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. )
One light point/fan point/bell point controlled by one, one way switch.
One 5 Amps socket outlet/switch socket outlet on independent board.
One 5 Amps socket outlet/switch socket outlet on same board with other switches.
M & L for point wiring complete for 15 Amps socket outlet on independent board with 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS, including 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H green colour cable as earth continuity conductor to common earth & connecting to earth dolly. Notes : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes in hard/dense soil, complete all as specified & directed.
S & F switch piano flush type 5/6 Amps, single pole, one way, 230 Volts complete all as specified and directed.
S & F switch piano flush type 15/16 Amps, single pole, one way, 230 Volts complete all as specified and directed.
Supply and Fix Socket outlet 2/3 pin 6 Amps, flush type, complete all as specified and directed.
Supply and Fix Socket outlet, 2 in 1 6 pin 10/16 Amps, flush type, single pole ,one way ,complete all as specified and directed.
S & F ceiling rose, three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F MCB SPN 40 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed.
S & F MCB DB single pole and neutral 4 way with 100 Amp rated bus bar double door complete all as specified and directed.
M & L cutting and pinning in brick walls for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but not exc 20 cm girth complete all as directed.
S & F for submain wiring with 2 runs of single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 04 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm bore concealed in walls/ceiling/floors including 4 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only. (ii) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
Supply and fix LED tube light fitting, baton integrated LED channel 22 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired including LED tube, colour temperature neutral white and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.
Supplying, Fixing/laying, jointing and testing and commissioning, LT under ground cables, 1100 Volts grade, XLPE insulated, armoured heavy duty electric cable with stranded aluminuim conductors, laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe complete all as specified and directed of following sizes:-
3.5 core 35 Sqmm Notes :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ against B/R items. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M & L for brick protection for UG XLPE cable with sub class 'B' bricks, old size laid dry and flat abutting each other with gaps between adjacent brick 10mm with width equal to length of brick in trenches across the cable complete all as directed.
S & F 50 mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 complete all as directed.
S & F wall mounted bus bar chamber, 100 A rating, 4 way , 230 V AC with suitable accessories and fittings complete all as directed Make: Havells Cat Part No: IHBC010004 or equivalent from L&T /Legrand / Indio Asian
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 15mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out in hard rock complete all as directed.
Demolition of Plain cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors, finished fair & even complete all as specified and directed. (48+8)
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
S & F in repairs white Vitreous china wash down water closet pan (pedestal pattern) with P or S trap including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed.
S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S & F in repairs vitreous china wash basin, white, flat back, size 550 x 400 mm including one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete including cutting for and pinning in ends of bracket or erecting stand complete all as directed.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed for following sizes:-
15mm bore.
20mm bore.
S & F 15mm bore bib tap cast copper alloy fancy type chromium plated long body with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15mm bore Pillar tap cast copper alloy fancy type chromium plated with capstan heads with long shanks and fly nuts screwed down high pressure, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15mm bore stop valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap 75mm dia outlet plain with Stainless steel grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as directed.
S & F in repairs PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and directed.
M & L for preparing New plastered walls surfaces and applying two coats of cement base paint over one coat of chalk whitingcomplete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as directed.
M & L for preparing old or previously treated ceiling surfaces and applying one coat of white wash on ceilings complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, In opening complete all as per specifications and drawings as applicable to item 08095 given in SSR Part – II (2010).
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II.
S & F 100 mm long butt hinges, medium weight, colled rolled mild steel & ISI marked complete all as specified and directed
S & F 500 litres capacity rotational moulded HDPE water storage tank tripple layer (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. Note : PVC tanks shall be ISI marked and having two layers.
M& L for RCC NP3 200 mm diameter Pipes laid on 150 mm thick PCC bed 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line functional for a depth 0.7 to 1.65 m complete all as specified and directed
S & F of Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as directed.
M & L for Mild steel round deformed or twisted bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S & F of PVC coated MS Galvanised Chain link fencing with 4mm dia wires , including line wires,having mesh size 75 mm X 75 mm to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
M/s Gupta Construction
kapoor and co
M/s B.Citymai Syiem
MAHINDER ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .