Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | L2₹3.3 L+₹1,799 (0.54%)Rejected-Finance AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L2 | Rejected-Finance Bid not be opened as per NIT terms. | |
| 3 | Rejected-Technical GUNJARDIH BHANDARIDAH BOKARO JHARKHAND PIN NO 829132 | BOKARO | JHARKHAND | 829132 | - | Rejected-Technical Technocommerically not accepted |
Tender Value
₹3.6 L
EMD Value
₹4,500
Closing Date
17 Mar 2025, 10:00 amClosed
Staff Officer EnM
Office of the General Manager, Dhori Area
Repairing of wiringRe-wiring of Sadafal Bal Mandir at Central colony, Makoli under CCD, G.M. unit, Dhori Area.
2025_CCL_331479_1
GM(D)/SO(EnM)/DA/24-25/72
Open Tender
Electrical and Maintenance Works
Item Wise
10 days
CCD
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,500
31 Mar 2025
6 Mar 2025
18 Mar 2025
7 Mar 2025
17 Mar 2025
7 Mar 2025
7 Mar 2025 - 12 Mar 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A a) Bulb point
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A b) Tube point
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A c) Fan point
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A d) Ex-haust point
Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ‘’C’’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole & neutral.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). : 6 way, double door.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp TP&N.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required : 2 x 6 sq.mm + 1 x 6 sq.mm earth wire.
Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 2 x 4 sq.mm for service wire.
Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 2 x 1.5 sq.mm for service wire.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal/ coke and salt as required.
Supplying and fixing 3 pin, 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Total impact of GST for the purpose of CTC
M/S SHIV PARBATI ENTERPRISES (BID ID -1140441)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .