| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.0 CrAccepted-AOC | ₹34.0 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹40.3 CrRejected-Finance GOKUL APARTMENTS BLOCK C SHIVMANDIR ROAD PUNJABI PARA SILIGURI 734 401 WEST BENGAL | SILIGURI | WEST BENGAL | 734401 | ₹40.3 Cr | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹50.0 CrRejected-Finance | ₹50.0 Cr | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected. (Work Experience details not submitted. Apart from that certificate of Solvency, Police Verification Certificate and Affidavits on no Govt Dues, No Arbitration, No Near Relatives in MES, Not Suspended / Debarred /Blacklisted not submitted.) |
Tender Value
₹35 Cr
EMD Value
₹15 L
Closing Date
7 Mar 2023, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734008 (WB)
PROVN OF OTM ACCN FOR INF BN (PH-II) AT KALIMPONG MIL STATION UNDER GE 867 EWS
2023_MES_573279_1
98750/KPG/SZ/E8 (CA No. CESZ/KPG/26 OF 2022-2023)
Open Tender
Civil Works
900 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE 867 EWS
₹15 L
Yes
HQ CE SILIGURI ZONE
1 May 2023
5 Jan 2023
14 Mar 2023
5 Jan 2023
7 Mar 2023
17 Feb 2023
5 Jan 2023 - 14 Jan 2023
18 Jan 2023
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 18,22,95,000.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,50,88,636.93 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,59,915.00 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 38,84,717.86 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT AND HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT AND HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,38,35,942.45 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,36,862.06 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 46,04,128.80 inserted by the MES in Schedule ‘A’ Part-VII.
PROTECTIVE WORK (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “(PROTECTIVE WORK)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,30,85,361.79 inserted by the MES in Schedule ‘A’ Part-VIII.
COMPOUND WALL, FENCING AND GATE (Sch 'A' Part-IX)
Lump sum price worked out by the Contractor for “(COMPOUND WALL, FENCING AND GATE)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 33,92,680.88 inserted by the MES in Schedule ‘A’ Part-IX.
EXTERNAL WATER SUPPLY (Sch 'A' Part-X)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,20,719.41 inserted by the MES in Schedule ‘A’ Part-X.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-XI)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 32,28,448.15 inserted by the MES in Schedule ‘A’ Part-XI.
MECHANICAL LAUNDRY (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(MECHANICAL LAUNDRY)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,31,497.46 inserted by the MES in Schedule ‘A’ Part-XII.
HOT WATER APPLIANCES (Sch 'A' Part-XIII)
Lump sum price worked out by the Contractor for “(HOT WATER APPLIANCES) ” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,15,027.90 inserted by the MES in Schedule ‘A’ Part-XIII.
LIGHTNING CONDUCTOR (Sch 'A' Part-XIV)
Lump sum price worked out by the Contractor for “(LIGHTNING CONDUCTOR)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,96,308.10 inserted by the MES in Schedule ‘A’ Part-XIV.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XV)
ROAD, PATH, CULVERT & HARDSTANDING M&L for liquid seal coat, applying evenly binder @ 9.80 Kg/10 Sqm blinded with paving bitumen with 6.3 mm size stone chippings @ 0.09 Cum per 10 Sqm and rolled to a uniform smooth surface complete all as specified and directed.
INTERNAL WATER SUPPLY S & F two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia brass CPcomplete all as specified and directed. MAKE : Jaquar / Crab Tree/Kohler.
S&F Pillar Cock (Low-flow) 16 mm dia brass CP complete all as specified and directed. MAKE : Jaquar /Crab Tree/Kohler.
S & F bib cock with wall flange quarter turn (Low-flow) 16 mm dia brass CP complete all as specified and directed. MAKE : Jaquar / Crab Tree/Kohler.
S & F 15mm bore Hand shower (Health faucet) brass CP with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed. MAKE : Jaquar / Crab Tree/Kohler.
S & F Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange brass chromium plated Stop valves complete all as specified and directed. MAKE : Jaquar or equivalent make as approved by GE.
S & F Overhead Shower 140 mm Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 16 mm dia brass CP complete all as specified and directed. MAKE : Jaquar or equivalent make as approved by GE.
S & F 15mm bore wall mixer with provision for Overhead Shower brass CP with 115 mm Long Bend Pipe on Upper side, connecting legs & wall Flanges complete all as specified and directed. MAKE : Jaquar or equivalent make as approved by GE.
S & F 15 mm bore Metropole Flush Valve brass CP Regular (Concealed Body) with Exposed Shut Off Provision (Fixed Discharge of 4.0 Lts. Per Flushing) complete all as specified and directed. MAKE : Jaquar or equivalent make as approved by GE.
INTERNAL ELECTRIFICATION S & F vertical triple pole & neutral double door, 6 way, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. MAKE : Schneider, Legrand, L & T NOTE : FP RCCB / RCBO / Isolator / MCB & SP/TP MCBs shall be measured and paid separately.
S & F of 100 A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 25 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. MAKE : Schneider, Legrand, L & T
S & F 20 W surface / wall mounted motion sensor LED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6000K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. MAKE : Philips Cat-Part No. motion sensing LED or equivalent model of Havells or Wipro
S & F FOR 10 Watt 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed. MAKE : Philips / Havells / Wipro / HPL.
SEWAGE DISPOSAL M&L for LLDPE septc tank conventional designed to carry sewage and sullage water excavation in in any type of soil, PCC (1:4:8) below foundation vent shaft connection etc complete for 10 users complete all as specified and direted.
M&L for LLDPE septc tank conventional designed to carry sewage and sullage water excavation in in any type of soil, PCC (1:4:8) below foundation vent shaft connection etc complete for 25 users complete all as specified and direted.
Provn of RCC septic tank conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 Design mix in wall, base slab, Baffle wall, roof slab including beams etc with vent shaft, manhole opening with cover connection etc, complete for 50 users all as specified and shown on drawing.
Provn of RCC septic tank conventional designed to carry sewage and sullage water , excavation in any type of soil, PCC (1:4:8) below foundation , RCC M-30 Design mix in wall, base slab, Baffle wall, roof slab,columns including beams etc with vent shaft, manhole opening with cover connection etc, complete for 150 users all as specified and shown on drawing.
Provn of Sokage wells excavation in any type of soil, foundation in PCC (1:3:6) walls of honey combed massonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick massonary in CM, RCC cover slab in M25 cover, interconnecting pipes of RCC completed filled with bricks bats of size 1.80m dia x 3.00 m effective depth all as specified and directed.
Provn of Sokage wells excavation in any type of soil, foundation in PCC (1:3:6) walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25 cover, interconnecting pipes of RCC completed filled with bricks bats of size 2.40m dia x 3.0 m effective depth all as specified and directed.
Provn of Sokage wells excavation in anytype of soil, foundation in PCC (1:3:6) walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25 cover, interconnecting pipes of RCC completed filled with bricks bats of size 2.40m dia x 4.50 m effective depth all as specified and directed.
Provn of Sokage wells excavation in anytype of soil, foundation in PCC (1:3:6) walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25 cover, interconnecting pipes of RCC completed filled with bricks bats of size 3.00m dia 4.50 m effective depth all as specified and directed.
EXTERNAL WATER SUPPLY S&F cast iron Air valves with single air outlets,confirming to IS 14845 of size 80 mm dia bore and fixing up in GI water supply mains of size 80 mm dia complete with cutting, threading of existing GI pipe with provision of Union of 80mm dia to existing pipe and GI pipe of 2 RM alongwith connected fitting such as tee etc for making arrangement complete all as specified and directed.
S&F cast iron Air valves with single air outlets,confirming to IS 14845 of size 100 mm . Dia bore and fixing up in GI water supply mains of size 100 mm dia complete with cutting, threading of existing GI pipe with provision of Union of 100mm dia to existing pipe and GI pipe of 2 RM alongwith connected fitting such as tee etc for making arrangement complete all as specified and directed.
EXTERNAL ELECTRIFICATION Material and labour for PCC cable path indicators with embosed on voltage, location and size of cable of 60cmx60cm size of indicator and embedded in PCC block (1:3:6) type using 20 mm grade stone aggregate including painting and earth work complete all as specified and directed.
Supply, Installation, commissioning and testing including connection of LT outdoor factory made CPRI approved feeder pillar box, cubical type multi tier panels with individual switchgear/MCCB encased in a separate cubical, copper busbar of 150 Amps, detachable side hinge front cover with screwed knobs, bending of edges of front cover with providing suitable rubber/neoprene gaskets at edges, protection class IP 65 as per IS 8623 of,weather, dust and vermin proof having overall hinged opening arrangement in both front & back sides fabricated out of MS Sheet 3.15 mm thick and frame of angle iron 50X50X6 mm duly welded including cable entry & exist through glands at bottom including two coats of powder coated paint over a coat of red oxide primer on both outer and inner surfaces of panel, internal connection from bus bar to switchgear/MCCB with suitable size of copper stranded PVC insulated wire with suitable copper lugs c with extended legs to suitable height embedded in and including PCC 1:3:6 foundation of suitable size all as specified and as directed including following items Note : Provn for additional MCCB shall be made for future fixing of MCCB. (Panel D1, TR-1) INCOMING a) Four pole MCCB 100 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In -01 Nos. OUTGOING (a) Four pole MCCB 63 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In-02 (b) Four pole MCB 10 Amps,415 Volt -02 Nos (c) Space for 63 amp MCCB -01 No. (d) Time switches 20 Amp ,415 Volt -01 No. (e) Power contractor 4 pole 25 amp cate part no-412551 of legrand- 01 No. Make of MCCBs- Legrand, ABB, L&T.
Supply, Installation, commissioning and testing including connection of LT outdoor factory made CPRI approved feeder pillar box, cubical type multi tier panels with individual switchgear/MCCB encased in a separate cubical, 300 Amps copper busbar, detachable side hinge front cover with screwed knobs, bending of edges of front cover with providing suitable rubber/neoprene gaskets at edges, protection class IP 65 as per IS 8623 double door,weather, dust and vermin proof having overall hinged opening arrangement in both front & back sides fabricated out of MS Sheet 3.15 mm thick and frame of angle iron 50X50X6 mm duly welded including cable entry & exist through glands at bottom including two coats of powder coated paint over a coat of red oxide primer on both outer and inner surfaces of panel, internal connection from bus bar to switchgear/MCCB with suitable size of copper stranded PVC insulated wire with suitable copper lugs with extended legs to suitable height embedded in and including PCC 1:3:6 foundation of suitable size all as specified and as directed including following items :- Note : Provn for additional MCCB shall be made for future fixing of MCCB. INCOMING a) Four pole MCCB 125 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In -01 Nos OUTGOING (a) Four pole MCCB 40 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In-02 Nos (b) Four pole MCCB 25 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In -01 No (c) Four pole MCCB 63 Amps,50 Hz ,415 Volt 25 KA, Icu=Ics= 100%, Thermal adjustable-0.8 to 1In -01 No (d) Space for 40 amp MCCB -01No Make of MCCBs - Legrand, ABB, L&T.
Supply, installation, testing and commissioning in replacement LT Busbar Panel board Outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and cable gland to incoming and outgoing cable with 2 hinges to panel doors and locking arrangement as desired complete all as specified and directed.
M&L for Motorized Auguring/driling in road at 75 cm depth of dia sutable for laying of 40/50/80/mm dia GI tubing pipe complete all as specified and directed.
MECHANICAL LAUNDRY Supply, Installation, testing & Commissioning of Industrial washing Machine front loading washing machine cap (60 Kg) , Dry weight per charge , Electrically heated inner basket & outer drum stainless steel 304 grade, Micro controller base cyclin timer PLC for Auto -Reserve, Auto-timed & Auto digital temperature control, water-inlet valve, drain valve, complete with control panel, & electric motor for wash, driven through pulleys & V belts and control panel , operates on 3 phase, 415V, 50 Hz complete with wiring of suitable size from main DB to machine with foundation including nuts and bolts complete all as specified and directed. MAKE : XSONI SYSTEMS/Luckey Engineering or equivalent.
Supply, Installation, testing & Commissioning Hydro Extrator balancing, with automatic electromagnetic DC Injecton brake system having capacity of 30 kg per charge with auto-timed, top loading, vibration less, Inner basket and outer drum stainless steel complete with specially designed electric motor and control panel. operates on 415V , 3 phase, 50 Hz AC supply, Operation cycle 5 to 10 minutes complete with wiring of suitable size from main DB to machine with foundation including nuts and bolts complete all as specified and directed. MAKE : XSONI SYSTEMS/Luckey Engineering or equivalent.
Supply, Installation, testing & Commissioning Drying tumbler front loading , open pocket, heavy duty drive system , Electrically heated with loading Capacity of 60 kg per charge with micro controller base cyclinc timer (PLC) for auto timed & auto-reserve, Auot digital temperature control, cool down system , fitted with control panel, one motor each for drive and blower. Double walled glass wool insulated outer body mild steel , inner basket stainless steel 304 grade, self lint screen, 'V' belt drive , waste Air exhaust etc, user friendly fully automatic panel controls operates on 415 Volt , 3 Phase , 50 Hz AC supply complete with wiring of suitable size from main DB to machine with foundation including nuts and bolts complete all as specified and directed. MAKE : XSONI SYSTEMS/Luckey Engineering or equivalent.
S&F MCCB 4P, 100 amps 415 volts, 50 Hz complete all as specified and directed. MAKE : Siemens/ Legrand/ Schnider.
REFRIGERATOR Supply, installation, testing and commissioning refrigerator of capacity 250 Ltr / nearest higher available capacity, frost free, multi flow type with separate chill compartment with plastic shelves, ice maker unit, vegetable / fruit drawer, coloured body as approved with suitable locking arrangement working on Non-CFC eco friendly refrigerant gas with 5 star energy rating and controlled as per BEE suitable for single phase, 230 V system complete all as specified and as directed. Make : Samsung / Voltas / LG/ Carrier / Godrej. Note : Fixing arrangements with accessories, connections with suitable size of copper cable shall be included in the quoted unit rate.
Supply, installation, testing and commissioning refrigerator of capacity 290 Ltr / nearest highest available capacity, frost free, multi flow type with separate chill compartment with plastic shelves, ice maker unit, vegetable / fruit drawer, coloured body as approved with suitable locking arrangement working on Non-CFC eco friendly refrigerant gas with 5 star rating and controlled as per BEE suitable for single phase, 230 V system all as specified and as directed. Make : Samsung / Voltas / LG/ Carrier / Godrej. Note :Fixing arrangements with accessories, connections with suitable size of copper cable shall be included in the quoted unit rate.
Supply, installation, testing and commissioning refrigerator of capacity 200 Ltr / nearest highest available capacity, frost free, multi flow type with separate chill compartment with plastic shelves, ice maker unit, vegetable / fruit drawer, coloured body as approved with suitable locking arrangement working on Non-CFC eco friendly refrigerant gas with 5 star energy rating and controlled as per BEE suitable for single phase, 230 V system all as specified and as directed. Make : Samsung / Voltas / LG/ Carrier / Godrej. Note : Fixing arrangements with accessories, connections with suitable size of copper cable shall be included in the quoted unit rate.
Supply, fixing, installation, connection & testing for voltage stailizer automatic operation, low and high voltage correction, equiped with electronic suitable for correction on single phase 50 Hz AC supply complete with voltmeter and designed for input voltage 170V to 250 V and output voltage stabilized between 215V to 240 V of capacity 1 KVA.
M/s KASHMIRA SINGH BARMI AND SONS
Hariom Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid