Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 CrAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.3 Cr Quoted ₹3.4 Cr | 1 | Accepted-AOC After deducting Sch of credit and reduction offered by contractor |
| 2 | 2₹3.6 Cr+₹25.6 L (7.65%)Rejected-Finance | ₹3.6 Cr+₹25.6 L (7.65%) | 2 | Rejected-Finance other than the lowest |
| 3 | 3₹3.7 Cr+₹33.9 L (10.1%)Rejected-Finance 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.7 Cr+₹33.9 L (10.1%) | 3 | Rejected-Finance other than the lowest |
| 4 | 4₹3.7 Cr+₹37.2 L (11.1%)Rejected-Finance | ₹3.7 Cr+₹37.2 L (11.1%) | 4 | Rejected-Finance other than the lowest |
| 5 | 5₹3.7 Cr+₹39.6 L (11.8%)Rejected-Finance GURDWARA LINE SHOWROOM NO 6 DESHMESH MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.7 Cr+₹39.6 L (11.8%) | 5 | Rejected-Finance other than the lowest |
| Sl No | Description | Qty | Unit | A.G.Construction L2 | P NAIDU L4 | SALCON ENGINEERS AND FABRICATORS L5 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L6 | surendra infrastructure pvt ltd L3 | Prasur Electricals & Engineering Co. L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling 75mm / 100mm / 110mm / 150mm/160mm internal dia cast iron/ PVC drain or vent pipe jointed in cement mortar laid in trenches or in any position including bends, branch pieces etc. complete all as specified and as directed. | 20 | RM | 109 ₹2,180 Lowest | 117 ₹2,340 | 112 ₹2,240 | 127 ₹2,540 | 142 ₹2,840 | 123 ₹2,460 |
| 2.00 | Demolition of cement concrete un-reinforced in any position and paving not exc 15cm thick above or below ground level etc complete all as specified and as directed. | 23.7 | Cum | 3,680 ₹87,216 | 3,160 ₹74,892 | 3,380 ₹80,106 | 4,000 ₹94,800 | 3,750 ₹88,875 | 1,749 ₹41,451.3 Lowest |
| 3.00 | Removing building materials etc. to a distance of 5Kms or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
Note: One Load Equals to 0.62 Cum of Aggregate | 40 | Load | 1,500 ₹60,000 | 850 ₹34,000 | 1,000 ₹40,000 | 2,250 ₹90,000 | 1,250 ₹50,000 | 333 ₹13,320 Lowest |
| 4.00 | Demolition of Precast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed. | 2 | Cum | 2,500 ₹5,000 | 2,250 ₹4,500 | 1,775 ₹3,550 Lowest | 3,775 ₹7,550 | 2,000 ₹4,000 | 2,245 ₹4,490 |
| 5.00 | Dismantling floor, hearth or wall tiling including cement
mortar bedding (but not backing), removing serviceable
tiles to store and rubbish off the premises complete all as specified and as directed. | 25 | Sqm | 177 ₹4,425 | 162 ₹4,050 | 155 ₹3,875 | 217 ₹5,425 | 162 ₹4,050 | 113 ₹2,825 Lowest |
| 6.00 | M & L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) 25mm thick as in levelling course, sub-floors and paving etc complete all as specified and as directed. | 5 | Sqm | 385 ₹1,925 | 333 ₹1,665 | 298 ₹1,490 | 408 ₹2,040 | 355 ₹1,775 | 262 ₹1,310 Lowest |
| 7.00 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:4) bedding complete all as specified and as directed. | 5 | Sqm | 2,200 ₹11,000 | 1,825 ₹9,125 | 1,940 ₹9,700 | 2,375 ₹11,875 | 2,000 ₹10,000 | 1,775 ₹8,875 Lowest |
| 8.00 | M&L for glazed ceramic designed coloured tiles as in vertical surfaces of size 300x450x7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match designed incl 10 mm thick backing coat in CM (1:3) complete all as specified and as directed. | 20 | Sqm | 2,025 ₹40,500 | 2,177 ₹43,540 | 2,250 ₹45,000 | 2,425 ₹48,500 | 2,000 ₹40,000 | 1,995 ₹39,900 Lowest |
| 9.00 | M&L for Roughening surfaces of old concrete floor by picking, hacking for keys, sweeping clean and washing down with water to remove dust, etc. for preparation for tiling complete all as specified and as directed | 96 | Sqm | 52 ₹4,992 | 47 ₹4,512 | 55 ₹5,280 | 77 ₹7,392 | 48 ₹4,608 | 42 ₹4,032 Lowest |
| 10.00 | M&L for Machine cut kota stone slab flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including cement screed bed 15mm thick in cement mortar 1:6 etc complete all as specified. | 96 | Sqm | 2,025 ₹1,94,400 | 1,925 ₹1,84,800 | 1,777 ₹1,70,592 | 2,225 ₹2,13,600 | 2,000 ₹1,92,000 | 1,595 ₹1,53,120 Lowest |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
13 Aug 2025, 6:00 pmClosed
CHIEF ENGINEER A and N Zone
HQ CE A and N Zone MES Brichgunj Junglighat post Sri Vijaya Puram
UPGRADATION OF FIRE MAIN AND FRESH WATER ARRANGEMENTS OF IN JETTY UNDER GE HADDO
2025_MES_712976_2
801272/E8
Open Tender
Civil Works
Item Rate
365 days
port blair
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
GE HADDO
₹4.0 L
Yes
26 Sept 2025
16 Jul 2025
15 Aug 2025
16 Jul 2025
13 Aug 2025
30 Jul 2025
Amount
Dismantling 75mm / 100mm / 110mm / 150mm/160mm internal dia cast iron/ PVC drain or vent pipe jointed in cement mortar laid in trenches or in any position including bends, branch pieces etc. complete all as specified and as directed.
Demolition of cement concrete un-reinforced in any position and paving not exc 15cm thick above or below ground level etc complete all as specified and as directed.
Removing building materials etc. to a distance of 5Kms or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. Note: One Load Equals to 0.62 Cum of Aggregate
Demolition of Precast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) 25mm thick as in levelling course, sub-floors and paving etc complete all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:4) bedding complete all as specified and as directed.
M&L for glazed ceramic designed coloured tiles as in vertical surfaces of size 300x450x7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match designed incl 10 mm thick backing coat in CM (1:3) complete all as specified and as directed.
M&L for Roughening surfaces of old concrete floor by picking, hacking for keys, sweeping clean and washing down with water to remove dust, etc. for preparation for tiling complete all as specified and as directed
M&L for Machine cut kota stone slab flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including cement screed bed 15mm thick in cement mortar 1:6 etc complete all as specified.
Taking down chowkhats or frames of any description with shutters without taking off shutters from frame exe 1.5 Sqm but n. exc 4 Sqm each etc complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters without taking off shutters from frame n.exe 1.5 Sqm each etc complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube, fixed in opening as per specification all as directed
S & F for Factory made solid PVC molded with particle board core door shutter 28 to 30 mm thick (style)with 2,4 or 6 raised panel design with 2mm thick molded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing all as specified and directed.
S&F in butt hinges extruded aluminium alloy with galvanized mild steel hinge pin ,anodized and fixed of hinge size 100 mm type B-21 complete all as specified and directed.
S&F extruded aluminum alloy handle fabricated type anodized 150mm long complete all as specified and directed.
S&F Aluminum anodized barrel tower bolt of extruded section 150mm long complete all as specified and directed.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket and necessary Builder hardwares required for functioning etc, with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F for Powder coated Aluminium grill (minimum thickness of powder coating 50 micron) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in charge.
Supply only plain sheet glass 4.0 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum window shutter not exc 0.5 Sqm in each pane all as specified and directed.
Supply only Aluminium alloy wire cloth 0.45 mm nominal dia of wire average width of aperture 1.40 mm and fixed with aluminum wire staples all as specified and directed.
S&F in repairs for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors etc using synthetic rubber adhesive cement solvent complete all as specified.
S&F in repairs for 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors etc using synthetic rubber adhesive cement solvent complete all as specified and directed.
S&F in repairs for 75 mm dia PVC (SWR) grade bends of any radius etc cement complete all as specified and directed.
M&L in repairs PVC (SWR) multi floor trap 75mm with grating including jointing with solvent etc cement complete all as specified and directed.
M&L for low density polyethylene (LDPE) pipes of 50mm, pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
S&F in repairs vitreous china counter wash hand basin flat back of size 550x 400 mm including brackets, 32 mm CP waste coupling, chain and plug, waste fittings, waste pipe and all necessary inlet, out let connections complete all as specified and directed.
S&F in repairs 15 mm bore pillar taps, cast copper alloy, chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed etc all as specified and directed.
S&F in repairs 15mm dia bib taps long body with flange cast copper alloy chromium plated fancy type with capstan head handle screwed down for Iron pipe or for brass ferrule etc complete all as specified and as directed.
S&F in repairs 15mm dia CP Angle cock with flange fancy type with capstan head handle screwed down for Iron pipe or for brass ferrule etc complete all as specified and as directed.
S&F in repairs of Vitreous china squatting pan, Orissa pattern of size 580 x 440mm,white with integral foot rest including trap and set in concrete P or S trap as per site requirements including making good to floor complete all as specified and directed by Engr -in- charge.
S&F in repair PVC valveless syphonic action type flushing cistern 10 ltr capacity white with intel ball valve float flush pipe and handled including brackets etc complete all as specified and directed by Engr -in- charge.
S&F in repairs Brass chromium plated tubular towel rail 20mm dia & 60 cm long between flange etc complete all as specified and directed by Engr -in- charge.
S&F in repairs PVC connection 15 mm dia and 450 mm long with bolt and nuts etc cement complete all as specified and directed by Engr -in- charge.
S&F for 300mm size Acrylic Corner shelf (soap stand) with guard suitable for bathroom / kitchen and fixed to wall complete all as specified and directed.
Taking up or down 15mm dia steel tubing connection, including cleaning for refixing or removal to store etc complete all as specified and directed.
Taking up or down 20mm dia steel tubing connection, including cleaning for refixing or removal to store etc complete all as specified and directed.
Supplying and laying of 20 mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr -in- charge.
Supplying and laying of 25 mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr -in- charge.
S&F in repairs for providing 20mm dia Gun Metal, globe or gate valves with iron wheel head, screwed both ends suitable for CPVC pipes etc complete all as specified and as directed.
Cutting chases in PCC block or Brick or stone walls for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by engineer- in- charge.
Dismantling plain or corrugated steel sheeting any gauge, thickness including similar pattern roof coverings complete all as specified and directed.
Dismantling of wrought iron or mild steel work and structural steel work of any description or otherwise provided for complete all specified and directed.
S&F for pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws as specified.
S&F for pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering, ridge, eves gutters etc fixed with self tapping screws as specified and directed by Engr -in- charge.
S&F for mild steel plates (plain or chequired) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A complete all as specified and as directed.
S&F Steel rolling shutters 1.25mm thick laths, gear operated type with level gear box and crank handle, with out ball bearing but including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated; push pull or manual type all as specified and as directed.
Supply only Ball Bearings for Rolling shutters (Heavy duty) etc all as specified and as directed.
M&L precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded stone aggregate) and setting in cement mortar (1:6) etc all as specified and directed by Engr -in- charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engr -in- charge.
M&L for 15mm thick plastering in CM 1:4 on concrete/block masonry wall surfaces and finished even and smooth without using extra cement etc all as specified and directed by Engr -in- charge.
M&L for 10mm thick plastering in CM (1:6) on concrete/ masonry wall block surfaces of walls finished even and smooth without using extra cement etc all as specified and as directed.
M&L for preparation on newly plastered external wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard).
M&L for Preparation of newly plastered Internal wall surface and applying two coats of white wash complete all as specified and as directed
M&L for complete removal of existing treatment of old decorated external wall surface by scrapping, washing, cleaning etc and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over treated surfaces complete all as specified and as directed
M&L for complete removal of existing treatment on wall by scrapping, washing, cleaning etc and applying two coats of white wash complete all as specified.
M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate as in 75mm thick as in sub base complete all as specified & directed by Engineer-in-Charge.
S&F for glossy finished heavy duty chequered cement concrete tiles 30cmx30cmx25mm thick set jointed with grey cement and pigment and pointed in neat cement slurry over and including 20 mm thick screed bed in CM(1:6) etc all as specified and as directed.
M & L Cement concrete type B-1 1:2:4 (20mm graded stone aggregate) in roof padding concerte of average 50 mm thick with water proofing compound as per manufacturers instructions etc complete all as specified and as directed. (WPC will be measured & paid separately under relevant Item)
M & L for Rendering 10mm thick in cm 1:3 mixed with water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surfaces is still green including finished even and smooth etc for easy laying of APP membrane on roof, complete all as specified and as directed (WPC will be measured & paid separately under relevant Item).
M&L for preparing plastered surfaces and applying primer @ 0.30/Kg per sqm and applying snadwich tack coat of bitumen 85/25 @ 1.2 kg/Sqm laying 3.0mm thick polyster reinforced APP modified water proofing membrane weighing not less than 3kg/sqm including removal of existing water proofing treamant on sunken slabs, edges and vertical surfaces complete all as specified
M&L for applying a coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over APP membrane surface complete all as specified and as directed.
Supply only Liquid water proofing compound
M&L for two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of new steel/iron surface of any description exc 10 cm in width or girth complete all as specified and directed
Taking down old rolling shutter inclduing ball bearing and grear box complete all as specified and directed
Chipping loose concrete and Exposing existing RCC columns, including plaster beyond main reinforcement carefully by means of chisel,and hammer or mechanically including necessary double scaffolding, erecting horizontal platforms at working levels to collect the debris, proping with top and bottom runners as directed stacking the debris in the compound as directed and carting away the same outside the premises etc. complete all as specified and directed
Relieving columns/beams of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately.
Chipping off existing loose, damaged Concrete from all affected RCC Columns, beams, slabs, etc beyond main r/f. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing r/f. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying “Polyalk EP” or equivalent as specified in the Brand Names.Polymer modified cement mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering complete all as specified and directed
Providing and fixing 12 mm diameter aluminum /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete all as specified and directed
Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing, Micro concreting complete all as specified and directed.
Providing and laying Super fluid Microconcrete -Roffe crete repairs (or equivalent as specified in the List of Brand names) in columns, including mixing with 5mm to 10mm size aggregates, waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification complete all as specified and directed.The item shall be paid on actual consumption of Micro concrete.
Glass Fiber Wrapping System:.Providing & laying applying Glass Fiber sheet wrap at structural members including.Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete.Wrapping: Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours.Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.) complete all as specified and directed.
Note:- All the structural strengthening items from sl. no. 69 to 75 above shall be executed by the authorized applicator only. THe certificate in this regard shall be held in records of GE.
Taking down MS/Cast iron pipes and connections including cutting out damaged parts etc, for the following bores
200 mm dia
150 mm dia
80 mm dia
M & L for disconnection electric connection, taking down the existing elctric driven pumping set of cap 30 to 90 KW alongwith motor from its existing foundation without any damage of the equipment and deposite to MES store and dismantling of the existing old motor foundation also all as specified and directed by Engr In Charge.
Marterial, labour and laying in replacement of Ductile iron pipe of 200 mm dia (8") bore double flanged type (both end flanged) centrifugally cast (spun) including suitable specials class A, K-9, in any length, laid in trenches/ floor/in side of IN Jetty or on supporting pillars as per IS-8239/2000 and with inside cement mortor lining and outside complete all as specified and directed. ( Note :- The cost included the suitable size of stainless steel bolts, nuts, washer not (less than 16 mm dia) and leather gasket complete all as specified and directed by Engr In Charge.
Supply and fix MS flanged pipe 200 mm NB heavy duty thickness not less than 4.8 mm, including all fabrication fittings and joints, cutting/welding/making bend etc at any angle as required length and layed in ground fixed on wall/ floor/ sump etc duly painted with 2 coats of synthetic enamel paint red colour over coat of zinc chromate primer complete all as specified and directed by Engr In Charge.
Description all as Item No 82.0 but GI flanged pipe 150 mm dia.
Description all as Item No 82.0 but GI flanged pipe 100 mm dia.
Description all as Item No 82.0 but GI flanged pipe 80 mm dia.
S&F hydrant valve for fire fighting, double headed, ISI marked, conforming to IS:5290, 63 mm dia or bore, oblique type with instantaneous hose coupling adapter etc., with necessary fitting material including taking down old unsv fire hydrant valve complete all as specified and as directed.
S & F Outdoor type Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard suitable for keeping 2 Nos hose pipe , branch pipe, nozzle, coupling etc including taking down old unsv hose pipe Complete all as specified and as directed.
S & F 63 mm dia gun metal branch pipe with 15 mm nozzle short conforming to IS-903 including taking down old unsv nozzle complete all as specified and as directed.
S & F non-percolating rubber reinforced lined RRL hose type- A 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS: 903- 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete as specified and directed by the engineer-in-charge.
S & F hose reel of 20 mm dia and 30 meter length complete conforming to IS-5132 all as including taking down old unsv reel complete specified and as directed.
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 including taking down old unsv nozzle complete all as specified and as directed.
S&F Non return valve flange type of size 200 mm dia (8") , ISI marked, heavy duty complete all as specified and as directed.
S&F Non return valve flange type of size 150 mm dia (6") , ISI marked, heavy duty complete all as specified and as directed.
S&F Non return valve flange type of size 100 mm dia (4") , ISI marked, heavy duty complete all as specified and as directed.
S&F cast iron sluice valve, 200 mm size or bore, class PN 1.6, ISI marked, heavy duty with brass spindle, operating wheel, flanged on both ends along with suitable new rubber packing (leather gasket), stainless steel bolts, nuts & washers and necessary modifications if required for fixing in location including taking down old unserviceable sluice valve of any description complete all as specified and as directed.
Description all as per item no 96.0 above but 150 mm dia.
Description all as per item no96.0 above but 100 mm dia.
Description all as per item no 96.0 above but 80 mm dia.
Supply, install and testing of new yard fire hydrant stand post of 80 mm dia Galvanized Iron (high grade) both flanged type 1.5 m height both ends flanged including duck foot bend double end flanged and sluice valve including taking down old unserviceable one complete all as specified and as directed.
Supply, installation, testing and commissioning of electric driven Main Fire Pump to deliver 2850 LPM flowrate at 90 m head and suitable for automatic operation and consisting of following, complete with accessories as specified and directed by the engineer-in-charge. [i] Horizontal type, single suction, multi-stage pump of cast iron body & stainless bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable RPM to deliver 2850 LPM flow rate at 90 MWC head. [ii] Suitable HP squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS 12615: 2018 & IS 15301: 2003. [iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required. [iv] Suitable cement concrete foundation duly plastered with anti vibration pads as per OEM Recommendation.
NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. [v] Pump sets shall be as per NFPA-20. [vi] Pump sets shall be installed as per IS 15301: 2003 [vii] 08 hours continous testing of electric driven fire Pump will be carried out by IEM. The cost of testing is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of electric driven Jockey Pump to deliver 180 LPM flowrate at 90 m head and suitable for automatic operation and consisting of following, complete with accessories as specified and directed by engineer-in-charge. [i] Horizontal type, single suction, multi-stage pump of cast iron body & stainless bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable to deliver 180 LPM flowrate at 90 MWC head. [ii] Suitable HP squirrel cage induction motor, TEFC, synchronous suitable RPM and suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS 12615: 2018. [iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required. [iv] Suitable cement concrete foundation duly plastered with anti vibration pads as per OEM Recommendation.
NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. [v] Pump sets shall be as per NFPA-20 [vi] Pump sets shall be installed as per IS 15301: 2003 [vii] 08 hours continous testing of electric driven fire Pump will be carried out by IEM. The cost of testing is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of factory made, as OEM approved manufacturers, fully compartmentalized bolted type Fire Emergency Panel (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.3 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. Note: Rate quoted shall be included for control wiring for smooth functioning of fire control panel in auto mode / mannual mode.
The FEP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 250 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB (LSI protection), conforming to IEC 60947-2: 2016, having adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc - 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. (b) 250/5A Cl. 1.0 C.T. with 15 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set (c) LED status indicators (SC, CSH, RTC)- 01 Set
S & F for DI specials such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of size 200 to 300 mm bore complete as as specified and directed.
Description all as above item No 109.0 but suitable for upto 150 mm bore.
S & F Pressure gauge (outdoor type) 4" dial 0-14 kgs rating all as specified and as directed.
M & L Cast Iron Air Valves with two air Outlets, 80 mm dia bore and fixing Up in cast iron watewr supply mains
Dismantling rusted/ damaged iron or mild steel work of any description not otherwise provided for all as specified and directed
S & F framed bracket of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fastners for wall etc as necessary gusset plates, riveting etc including cutting tops to shape as directed, drilling holes, notching as required at site all as specified and directed by Engr In Charge.
Material & labour for laying of chequered plates by cutting / making in to the shape providing necessary angular supports and handles with 6 mm dia rod as per the site condition for cable trenches, hydrant chamber etc alongwith painting of one coat of synthetic enamel over a coat of two coats of redoxide all as specified and directed by Engr In Charge.
Supply and fix Foot Valve alonwith complete accessories, conforming to IS 4038, 200 mm (8”) dia fixing with stainless steel nut, bolt and washers complete all as specified and directed by Engr In Charge.
Description all as per Item No 116.0 above but 100-150 mm (6") dia.
Supply and fix Valve, butterfly conforming to IS 13095, 200 mm (8”) dia fixing with stainless steel nut, bolt and washers complete all as specified and directed by Engr In Charge.
S & F 25 mm dia outer dia CPVC pipies SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed.
S & F 40 mm dia outer dia CPVC pipies SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed.
M&L of PP-R Ball valves (brass insert) of size 25 mm dia as per requirement of the site all as specifed and directed by Engr in Charge.
M&L of PP-R Ball valves (brass insert) of size 40 mm dia as per requirement of the site all as specifed and directed by Engr in Charge.
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. RCC cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. Notes: (i) Cost of GI strip and GI protection pipe upto 7.5mtr length for one earth pit shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32 x 6 mm all as directed ad specified.
Material & labour preparation of new surfaces of steel/CI pipe line or any description by brushing/cleaning stain, greasy spots etc with thinner, applying two coats of spray painting on all sides after using priming with aluminium red oxide with spraying machine in the pump house/ pipe line in duct duly marking / showing direction etc complete all as specified and directed by Engr In Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor IS-7098, Part-I, of size 1 core 25 Sqmm, laid in tray, ducts, pole,wall etc for 2 x Jockey Pumps complete all as specified and directed by Engr In Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor IS-7098, Part-I, of size 1 core 70 Sqmm, laid in tray, ducts, pole,wall etc for 2 x centrifugal Pumps complete all as specified and directed by Engr In Charge.
M & L for cutting the road/ footpath/ hard standing etc for laying of pipe all as directed by Engr In Charge.
Taking down of old unsv LT UG XLPE cable, 1100 volt grade of size 25 to 70 sqmm 3.5 core from any position all as directed.
M & L for demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including aluminium lugs complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core including aluminium lugs complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core including aluminium lugs complete all as specified and directed.
Supply, Install & fixing of out door type dust & vermin proof LT feeder pillar box panel CPRI approved, IP 55 protection with canopy by using suitable angular iron frame for each unit panel fixing with nuts & bolts on 70 x 40 ICMS channel as per directions as per directions of Engineer-in-Charge and using 3.15 mm thick CRCA sheet all over body front and back cover with hinges and aldrops for locking armagments duty 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duty painted with ONE coat of redoxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 1.5 Sqmm FRLS copper cable and 6 A MCB's meters breaker control supply and indication lamps and the following switch gears /MCCB's alumunium bus bars and accessories :
Aluminium bus bar of 400 Amps for RYB (live) and 400 Amps for neutral as main bus bar. Aluminium bus bar as down links/connectivity links to LT MCCBs for connecting all incoming , outgoing cables and bus couplers. Digital ammeter ( 0-400 ) & voltmeter ( 0-500 ) for incoming Make: Schnider / Elmeasure. LED indication lamps for RYB for incoming supply and for breaker on / off indications. 1. 4 Pole MCCB - 250 Amps, 36KA - 01 No, as incomer and, 4 Pole MCCB 160 Amps, 25 KA-02 Nos ( 01 working & 01 stand by ) MCCBs 63 Amps, 16 KA - 3 No's and 20 A single phase timer with power contactor as outgoings all as directed by the engineer in charge All MCCBs of 4 pole 36 & 25 KA, 440 V AC with thermal triping system against Short circuit instantaneous and earth fault protection all as specified and directed. Make of MCCB: Schneider/SIEMENS/ABB/L&T
NOTE: (i) Rate quoted includes necessary grouting / chipping of concrete for Anchring fastners and making PCC foundation to fix the LT Panel and connecting of necessary LT cables with new end terminations as directed by the engineer - in - charge. (ii) Rate quoted includes necessary Digital ammeter, voltmeter, LED lamps, CTs, Aluminium bus bar and MCCB's. (iii) Drawing must be got approved by GE before fabrication of the panel.
Precast cement concrete (PCC) type D2 1:4:8 using 40mm graded aggregate stone for making foundation of Pole/stay assembly complete all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 180 mm (OD) x 163 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 125 mm (OD) x 107 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed.
Supply and installed water cooler Electric driven fully stain les steel body (single phase)having approximate storage capacity of 80 ltrs and nominal cooling capacity of 40 ltrs per hour including inlet and outlet pipe lines along with drain pipes of suitable CPVC pipe lines all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 20 mm dia on walls/ceiling or laying in floors complete along with necessary CPVC fittings including all as specified and directed.
M & L for Bib taps, of size 20 mm dia chromium plated fancy type alloy with crutch or butterfly handle, screwed down, screwed for iron pipe fixed in any length and type includung necessary fittings all as specified and directed.
M & L point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 3 pin 15 Amps socket out let on independent board, FRLS PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed conduit of size not less than 20mm dia, with all necessary fittings, concealed in walls /roof/ floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :- Make : Polycab/Havells /Finolex/ Gloster/Anchor
S & F Socket outlet 2 in 1 modular type, 3 pin,6/16A, flush type, universal all as directed.
S & F Switch piano modular type , flush type, single pole one way 16 amps all as directed.
S & F Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC Casing and capping (ISI marked) incl all specials and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA including all as specified and directed.
Supply and fix for Gun metal globe or gate valve of 20 mm dia ISI marked high pressure with iron wheel head screwed both ends for iron pipe line and fixed in any length of pipe line including all as specified and directed.
Dismantling of the existing HOT cranes of capacity 3 Ton located in sea water pump house including removal of DSL system with cable etc. for HOT crane and all the dismantling items deposited at MES storeyard all as directed and specified.
Design, manufacture, supply, installation, erection, testing and commissioning of Single Girder HOT cranes to suit the following specifications. 1. Capacity - 3.0 Tonne 2. span - 6.1 Mtrs. 3. height of lift - 4 Mtrs. 4. bay length - 15.65 Mtrs. Note: (i) This includes supply & fixing of GI Shrouded Bus Bar system = 15.65 Mtrs (ii) The existing long travel track and gantry girder shall beused. The gear trolley and chain pulley block shall be of preferably INDEF/MORRIS make. Location: Sea water pump house TheDesign and drawings shall be vetted by Government Engineering College/NIT/IIT. NOTE :- The testing of HOT crane continously for 08 hours will be carried out in presence of IEM. The cost of testing is deemed to be included in the quoted rates. The following test shall also be carried out at facory premises of Manufacturer in the presence of testing officer detailed by Accepting officer before dispatch:- (a) Deflection Test:- As per IS 3177-1999 (b) Brake test:- Hoist brake shall be checked with rated load as well as overload as per the codal provisions.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping of pole including use & waste of necessary form work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as as directed by engineer in charge.
Supply & fixed in repairs to wall, laid under floor, wall ceiling GI tubing medium grade ISI marked complete with all fittings, accessories all as directed of following sizes :
100mm dia
80mm dia
50mm dia
40mm dia
S&F in repairs for gunmetal gate valve, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, as fixed in repairs complete all as specified and as directed by the Engineer-in-charge of the following diameters:
80mm dia
50mm dia
50mm dia
Material,labour and laying in repairs for ductile iron pipe of 150 mm bore double flanged type(both end flanged) blue colour centrifugally cast (spun) including suitable specials class A, K-9, in any length, laid in trenches/floors/in side jetty or on supporting pillar as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour complete all as specified and as directed. Note : cost includes the suitable stainless steel nuts and bolts along with leather gasket.
Material,labour and laying in repiras for ductile iron pipe of 100 mm bore double flanged type(both end flanged) blue colour centrifugally cast (spun) including suitable specials class A, K-9, in any length, laid in trenches/floors/in side jetty or on supporting pillar as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour complete all as specified and as directed. Note : cost includes the suitable stainless steel nuts and bolts along with washer leather gasket.
Supply and fix for Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia.including all as specified and directed.
Material and labour for construction of Brick Masonary valve chamber of size 900x900x900mm (internal dimensions) with PCC 1:4:8 foundation 100mm thick, brick work using PCC block masonary 200 thick wall built in CM 1:6,PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal wall including floor,and exeternal wall upto 150mm below ground level, including excavtion earth work in hard/dense soil, MS sheet cover 4mm thick with locking arrangement with ISA 50x50x6 mm frame embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed
Material and labour for plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete including use and waste of from work complete all as specified and directed.
Material and labour for supporting pillar constructed of masonry of dimensions as required on site with precast cement concrete solid block masonry in PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 20 mm thick in CM (1:6) complete all as specified and directed.
M & L Lifting RCC cover slabs of size 2 to 4 meters long, 1 to 1.5 meter width and upto 300mm thick and about 2 to 4 tons in weight lying on jetty by cutting /chipping the clearance groove all around ,keeping aside using a crane for layiing of new LT cables/water pipe line including removing of old water pipes of any type and any sizeand making good surface with PCC 1:2:4 complete all as specified and as directed. Note : (a) two or three slabs shall be taken out/removed as per site condition for laying the new water pipe line in the span of 4 to 5 meters, as per site requirement extra slabs if required to remove it will be also measured separately (b) Cost of T & P required for the work shall be included in the quoted rate. (c) Site will be available in a restricted manner and prior approval shall be obtained before work (d) Contractor is liable for any damage caused to existing services or structtures during the execution of work.
M& L for Demolition of fresh water outlets PCC chambers for and create hole for fixing the new outlets as required and making good the disturbed portion with required PCC of 1:2:4 as per site condition complete all as specified as directed by Engr-In-Charge.
Supply and fixing for water meter industrial type, magnetically coupled, screwed, supplied and installed complete of size 150 mm dia complete all as specified and as directed.
Supply and fixing for brass strainer, complete of size 150 mm dia complete all as specified and as directed.
Supply,install and commissioning of cast ironThree Phase 15 HP Monobloc Pumpset, Model - KDS 1537 +, Make - KIRLOSKAR BROTHERS LIMITED (or equivalent as per Makes in PS) having discharge of minimum of 22 LPS and Head of 32 meter operating voltage of 415V and 50 HZ, AC supply, impeller bronze, shaft carbon steel, shast sleeve bronze(LTB2), protection IP 44 and class F, including ( 100 x 80 mm ) suction and delivery lines with suitable foot valve brass 100 mm dia connected, providing 63 MCB, 16 KA, 415 Volt , 50 HZ fixing with existing panel board complete all as specified and as directed.
Supply and fix CI/DI fitting for double flanged pipe such as bends (any type , radius and angle) tapers any type , (straight , bend increasing , decreasing or double socket etc) tee pieces single branch , Y junction double branch , of size - up to 150 mm dia all as specified and directed.
Taking down Old Unserviceable DI/CI Pipe of size 150 / 100 mm dia complete all as specified and directed.
Taking down Old Unserviceable GI Pipe of size upto 100 mm dia complete all as specified and directed.
Taking down Old Unserviceable Air release and sluice valve of size upto 150 mm dia complete all as specified and directed.
Taking down Old Unserviceable Gate valve of size upto 100 mm dia complete all as specified and directed.
Supplying , install , commissioning and testing wall mounted water level digital indicator for showing the capacity of overhead water tank/ under ground sump in 10 equal divisions electrically operated including sensor necessary electrical connections with Submersible copper cable of size 2.5 sqmm flat along with PVC conduit 20 mm dia including clamping from OHT/ UG sump to Digital visual Indicator Unit, necessary fabrication works, complete PCC works and comprising of the following:- (a) Automatic multilevel visual indicator-01No. (b) Sensor of stainless steel probe SS316- 10 Nos. (c) Alarm - 01 No.
M &L for Rotational moulded polyethylene 10000 LTRS PVC water storage tanks Tripple layer (cylindrical vertical with closed top) hoisted and fixed in position along with 50 mm float valve including base arrangement with necessary PCC all as specified in SSR Part I complete all as specified and as directed.
M & L for Star delta Starter fully automatic in sheet steel enclosure type MN/ML , Motor rating AC-3 duty, 50 HZ, 3 phase, MN 16 FASD, Cat No. SS94362 of L&Tsuitable for 415 V, AC of capacity 17.5 HP, 13 KW, relay range of 15 Amps, complete all as specified and as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4.0 sq mm ,3 core, 1100 Volts grade along with PVC conduit 25 mm dia including all as specified and directed.
Excavation in trenches hard soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out including all as specified and directed.
M&L for returning ,filling in including spreading, levelling,watering and well ramming in layers not exc 25cm in hard dense soil complete all as specified.
M & L for Removing excavated materials (soils) n exc 50m and depositing where directed at a level n exc 1.5m above the statrting point complete all as specified.
A.G.Construction (BID ID -3384712)
surendra infrastructure pvt ltd (BID ID -3384820)
P NAIDU (BID ID -3384748)
SALCON ENGINEERS AND FABRICATORS (BID ID -3384811)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3384810)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .