| 1 | L1₹25.3 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹28.0 L+₹2.5 L (9.74%)Rejected-Finance 544 STREET NO 10 GHUMMAN NAGAR PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.4 L+₹6.0 L (23.4%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹32.2 L+₹6.8 L (26.5%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being L4 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
25 Jun 2022, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_521976_2
GE(S)/PAT/T-09/N/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹70,000
Yes
19 Jul 2022
6 Jun 2022
27 Jun 2022
6 Jun 2022
25 Jun 2022
13 Jun 2022
Amount
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed by Engr-in-Charge Note : Water proofing compound shall be measured and paid saparately under item .
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engr-in-Charge.
M&L 10mm thick cement plastering in cement mortar CM 1:6 on brick work/ concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint over a coat of cement primer complete all as specified and directed by Engr-in-Charge.
M&L Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over complete all as specified and directed by Engr-in-Charge.
Preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces complete all as specified and directed by Engr-in-Charge.
M&L for one coat of cement based paint on wall including preparation of old plastered or unplastered surface including washing rubbing down and stoping of distempered and painted surface complete all as specified and directed by Engr-in-Charge.
M&L for one coat of distemper on wall including preparation of old plastered or unplastered surface including washing rubbing down and filling nail holes with putty and painted surface complete all as specified and directed by Engr-in-Charge.
M&L for one coat of distemper on ceiling including preparation of old plastered or unplastered surface including washing rubbing down and stoping of distempered and painted surface complete all as specified and directed by Engr-in-Charge.
M&L Preparation old steel surfaces of any desription and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L Preparation old wooden surfaces of any desription and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment of any type/description such as cement base paint, external emulsion , internal distemper, internal painting etc from external surfaces/ Internal of walls/RCC surfaces/soffits of chajjas/ roof projections/ cantilevers/ balcony etc with mechanical means/ grinder including removal of waste material from site complete all as specified and directed by Engr-in-Charge.
Applying acrylic wall care putty in external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior/interiar painting complete all as specified and directed by Engr-in-Charge.
Applying 02 coats of exterior emulsion paint of Apex Weather proof paint (light shade) as per manufacturer instructions by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engr-in-Charge.
Applying 01 coats of exterior emulsion paint of Apex Weather proof paint (light shade) as per manufacturer instructions by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces by using following brands of emulsion complete all as specified and directed by Engr-in-Charge.
Applying 02 coats of interior emulsion paint (light shade) as per manufacturer intructions by using roller to wall surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engr-in-Charge.
Dismantling of brick tiles or terracing tiles single layar on roofs complete all as specified and directed by Engr-in-Charge.
Demolation and removal of mud puska on roof any thickness complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6, type B-0 using 12.5 mm graded stone aggregates as in padding over roof ,minimum thickness at khurra as 50mm maintain a slope of 1:100 using water proofing compound complete all as specified and directed by Engr-in-Charge
M&L PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred complete all as specified and directed by Engr-in-Charge
M&L for the following roof treatment. (a) 15 mm thick (average) cement screed/plaster in CM 1:4 on roof ( concrete surfces) finishing even and fair all as specified. (b) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed. (c) Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm. (d) Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed. (e) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces all as directed and specified.
M&L PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge including flat iror clamps 25x3mm complete all as specified including taking out old damaged AC rain water pipes.
M&L PVC (SWR) bends of any radius for 110 mm dia rain water pipes with rubber ring joints a complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing of 15mm size and removal to store complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing of 20mm size and removal to store complete all as specified and directed by Engr-in-Charge.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
Dismantling 500ltr water storage tank and removing to store complete all as specified and directed by Engr-in-Charge.
Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1.
S&F 20mm Stop valves/ gate valve , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams, ceilings and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including cutting grooves in brick /concrete wall and preparation of surfaces to receive finishes complete all as specified and directed by Engr-in-Charge.
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed by Engr-in-Charge.
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for complete all as specified and directed by Engr-in-Charge.
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for complete all as specified and directed by Engr-in-Charge.
M&L for rectangle / Squar /circular hollow section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165) complete all as specified and directed by Engr-in-Charge.
S&F for plates /cleats/connplates of Fe410-W(Gde-E-250)quality A etc for frame work complete all as specified and directed by Engr-in-Charge.
M&L for Preparation new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide as in primer complete all as specified and directed by Engr-in-Charge.
S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed by Engr-in-Charge.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Dismantling of brick work built in cement mortar incl all quoins, arches, pillar etc complete all as specified and directed by Engr-in-Charge.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge.
M&L 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed by Engr-in-Charge.
Providing and Laying Premium (1st quality) straight edge, stain free, gloss finish, square marbonite single charged vitrified tiles in 600x600x 9 to 10mm thick in floors etc in approved shade, set & jointed in neat cement including and over 20mm in screed bed in CM (1:4) and pointed in white coloured cement to match, in floors etc. complete all as specified and directed by Engr-in- Charge.
FAVOURITE ENGINEERS
Buttar Construction Co.
AGGARWAL & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .