| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹13.0 L+₹16,275 (1.27%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹14.9 L+₹2.1 L (16.1%)Rejected-Finance 6 U 34 JAWAHAR NAGAR SRI GANGANAGAR SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | Rejected-Technical 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | - | Rejected-Technical Slow Prog. Ser No 73 of WLR for the QE Jun 2023 of HQ CE BTZ. |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
19 Oct 2023, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR AND MAINT OF AC PLANT WINDOW AND SPLIT AIR CONDITIONER AND MISC CONNECTED WORKS AT MIL STN SRIGANGANAGAR
2023_MES_619467_1
CA NO CWE SGNR T-34 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SRI GANGANAGAR
As per NIT
9 documents required · 9 mandatory
₹500
GE SRI GANGANAGAR
₹30,000
6 Dec 2023
18 Sept 2023
21 Oct 2023
18 Sept 2023
19 Oct 2023
5 Oct 2023
Amount
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler, supply & fixing of new Hermetic sealed unit compressor along with OLP & starting relay of capacity 1 ton suitable for water cooler of cooling capacity 150 Litres per hour including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 1.00 above but of capacity 1/2 HP suitable for water coolers of cooling capacity 60 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 1.00 above but of capacity 1/3 HP suitable for water coolers of cooling capacity 40 Ltrs/Hr complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of fan motor, Capacitor starter with blade, single phase, AC, 50 HZ suitable for water cooler of cooling capacity 40/60 litre per hour including fittings on existing MS plate form and making connection all as specified and directed by Engineer-in-Charge. Make : Polar/Khaitan/Cool Home.
All as per Ser item No 4.00 above but suitable for water Cooler 150 Ltrs Cap.
Rewinding of fan motor with super enameled copper winding wire of adequate size and gauge as per existing winding including insulating material, varnish drying, baking etc for water cooler of capacity 150 litre per hour all as specified and directed by Engineer-in-Charge.
All as per Ser item No 6.00 above but suitable for 40 Ltrs Cap.
Supply and fixing in replacement push cock CP brass 15 mm dia bore suitable for water cooler
Cleaning/ flushing the unit with N2 gas and supplying and recharging the refrigerant gas in water cooler capacity 150 litre per hour including replacement of strainer complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 9.00 above but of cooling capacity 40/60 Ltrs/Hr all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting relay suitable for water cooler of capacity 150 litre per hour all as specified and directed by Engineer-in-Charge. Make : Renutrol/USHA or equivalent.
All as per Ser item No 11.00 above but of cooling capacity 40/60 ltrs/Hr all as specified and directed by Engineer-in-Charge.
Supply and fixing replacement of copper tubing size 3/5 mm dia for suction & discharge lines in water cooler.
Supply and fixing in replacement of running capacitor 25 MFD oil filled suitable for water cooler of capacity 150 litre per hour all as specified and directed by Engineer-in-Charge. Make - USHA / KELTRON / SEATRON
All as per Ser item No 14.00 above but of capacity 10/20 MFD for water cooler of cooling capacity 40/60 Ltrs/Hr all as specified and directed by Engineer-in-Charge. Make : USHA / KELTRON / SEATRON.
Supply and fixing in replacement of starting capacitor 80/100 MFD oil filled suitable for water cooler of capacity 150 litre per hour and making necessary electric connection all as per specified and directed by Engineer- in-Charge. Make : USHA / KELTRON/ SEATRON
All as per Ser item No 16.00 above but of capacity 40/60 MFD for water cooler of cooling capacity 40/60 Ltrs/Hr all as specified and directed by Engineer-in-Charge. Make : USHA / KELTRON / SEATRON/ Tib Cap
Supply and replacement of thermostat switch complete with plate and screw suitable for water cooler of cooling capacity 150/60/40 litre per hours and making necessary electric connection all as specified and directed by Engineer -in-Charge. Make : RENUTROL/DANFOSS /Honeywell
Supply and fixing in replacement of copper wiring kit complete suitable for water cooler of capacity 40/60/150 litre per hour and making necessary electric connection all as specified and directed by Engineer-in-Charge.
M&L for Spray painting to water cooler of capacity 150 Litre per hour with one coat of synthetic enamel paint including preparing the existing painted surface. Colour shall be as per existing shade complete all as specified and directed by Engineer -in-Charge.
All as per Ser item No 20.00 above but for water cooler of cooling capacity 40/60 Ltrs/Hr all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement PVC drain pipe 25/32 mm bore heavy duty including clamp for water cooler all as specified and directed by Engineer-in-Charge.
Welding and patch repair of bottom and side panel of water coolers including replacement of bottom MS Sheet of 16 gauge for mounting compressors and blower motors all as specified and directed by Engineer-in-Charge.
REPAIRS OF REGRIGERATORS Disconnecting , dismantling and taking out existing burnt out compressor from the machine, supply & fixing Hermetic sealed unit compressor along with OLP & starting relay as per existing model & make suitable for Refrigerator of capacity 165/170 litre, suitable for operation on 280 volt AC supply including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : Kirloskar/ Whirlpool or equivalent.
All as per Ser item No 24.00 above but for refrigerator of capacity 280/300/310 Ltrs & 320 ltrs of deep freezer all as specified and directed by Engineer- in-Charge.
Cleaning / Flushing the gas system with N2 gas and supplying and recharging the refrigerator of capacity 165 to 310 litre& deep freezer with refrigerant gas including replacement of strainer and compressor oil and rectification of leakage in the entire system complete all as specified and directed by Engineer- in- Charge.
Supply and fixing in replacement of over load protector suitable for 310 / 286 / 165 litre capacity refrigerator & 300/320 ltr deep freezer all as specified and directed by Engineer -in-Charge. Make : Renutrol/ Whirlpool / Classic.
Supply and fixing in replacement of thermostat switch with knob, plate and screws for automatic defrosting device suitable for 310/286/165 litre capacity refrigerator & deep freezer 320/300 ltrs all as specified and directed by Engineer -in-Charge. Make : INDFOS/WHIRLPOOL/KIRLOSKAR.
Supply and fixing in replacement of door gasket suitable for deepfreezer 300/320 ltr &310/286/165 litre capacity refrigerator all as specified and directed by Engineer -in-Charge.
Spray painting to refrigerator of capacity 165 to 310 litre with one coat of synthetic enamel paint including preparing the existing painted surface complete all as specified and marked with MES all as directed by Engineer -in- Charge.
Welding and patch repair of bottom and side panels of refrigerators including replacement of bottom sheet 16 gauge for housing compressors all as specified and directed by Engineer -in-Charge.
Supply and fixing in replacement of freezer including necessary capillary suitable for 165 litr capacity complete all as specified and directed by Engineer -in-Charge.
All as per Ser item No 32.00 above but 286 to 300 litrs
All as per Ser item No 32.00 above but 310 to 325 litres
Supply and fixing in replacement replacement condenser coil/Tube set suitable for 310/ 286 Ltr cap & deep freezer 300/320 ltrs
All as per Ser item No 35.00 above but for 165/ 175 Ltr cap .
REPAIR TO WINDOW /SPLIT TYPE AC Supply & fixing in replacement of condenser coil set suitable for Window Type Air Conditioner of cap 1.5 Ton as per existing size.
Supply & Fixing in replacement of condenser coil set suitable for Split Type Air Conditioner of cap 1.5/2.0 Ton as per existing size.
Disconnecting, dismantling and taking out existing burnt out compressor from the machine ,supply & fixing of Hermetic sealed unit compressor of cap 1.5/2 Ton , Split AC including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
Disconnecting , dismantling and taking out existing burnt out compressor from the machine ,supply & fixing of Hermetic sealed unit compressor of cap 2 Ton , Window AC including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 40.00 above but for 1.5 Ton compressor.
All as per Ser item No 40.00 above but for 1.0 Ton compressor.
S&F of blower motor of single phase for exhaust fan fitted in window/ split type air conditioner of capacity upto1/ 1.5/2 ton with supper enameled copper winding wire of gauge & weight equal to existing and replacing gun metal bushes including taking out from the air conditioner and refixing in its original position after rewinding complete all as directed by Engineer -in- Charge.
Rewinding of blower motor of any make single phase for exhaust fan fitted in window type air conditioner of capacity upto1/ 1.5/2 ton with supper enameled copper winding wire of gauge & weight equal to existing and replacing gun metal bushes including taking out from the air conditioner and refixing in its original position after rewinding complete all as directed by Engineer -in- Charge.
S&F of blower motor for split AC fitted In internal unit capacity 1200 to 1400 RPM suitable for 1.5/2 Ton with copper winding wire all as specified and directed by Engr-in-Charge.
S&F of swing motor for split AC fitted in internal unit capacity 3 to 5 watt , RPM 5 to 8 RPM suitable for 1.5/2 Ton with wiring kit and thimble all as specified and directed by Engr-in-Charge.
Taking out split/window type air conditioner upto 1.5 ton capacity from its position, checking , removing the leakage from refrigeration and charging the refrigerant gas including replacement of strainers and injecting anti moisture dose, fixing in position after testing complete all as specified and directed by Engineer - in charge.
Supply and fixing in replacement of starting relay suitable for window /split type air conditioners upto 1.5/2 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in -Charge.
Supply and fixing in replacement of over load protector suitable for window/split type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge. Make : Renutrol/Usha/ Shriram
Supply and fixing in replacement of starting capacitor 6 MFD oil filled, 230 volts for blower fan motor including making necessary connections complete all specified and directed by Engineer- in-Charge. Make :TIBCAP or equivalent.
Supply and fixing in replacement of running capacitor for window / split tyep AC of 40/50 MFD (reqd as existing machine) , 230 volts , thimble type including making necessary connections complete all specified and directed by Engineer- in-Charge. Make :TIBCAP or equivalent.
Supply and fixing in replacement of thermostat switch protector suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge. Make : Renutrol/Indfos or equivalent
Supply and fixing in replacement of copper wiring kit suitable for 1.5/2 TR capacity air conditioner and making necessary connections with brass thimbles all as specified and directed by Engineer - in- Charge.
Supply and fixing in replacement of air filter for window type air conditioner as per sample suitable for capacity upto 1.5 ton all as specified and directed by Engineer - in- Charge.
Supply and fixing in replacement of front grill of window type air conditioners upto 1.5 ton capacity as per model of the air conditioner all as specified and directed by Engineer - in- Charge.
Maintenance, servicing and testing of split type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site all as directed by Engineer - in- Charge.
Maintenance, servicing and testing of window type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site all as directed by Engineer - in- Charge.
Taking out the unserviceable copper cable by disconnecting all the electrical connections and supply and fix new PVC sheathed copper cable .3 core of size 70 / 0.0076 including reconnecting and resting complete all as directed.
Supply and fix industrial type sheet metal enclosure with metal clad plug and socket single phase with a two pin and earth plug & socket complete rated 240V 30 Amps capacity controlled by and including 01 No 30 Amps MCB SP 9 KA rupturing capacity all as specified and directed.
Taking down the unserviceable printed circuit board (PCB) by disconnecting all the electrical connections and supply and fix new printed circuit board (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed. Make : Hitachi or equivalent
Taking down the unserviceable printed circuit board (PCB) by disconnecting all the electrical connections and supply and fix new printed circuit board (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for window type AC and complete all as directed. Make : Hitachi or equivalent
Supply and fix the copper pipe for 1.5TR/2TR/3TR(2x1.5TR) capacity of the following sizes:-
Taking out the unserviceable metallic fan blades suitable for blower motor for the split type air conditioners and S&F new metallic fan blade of blower motor for split type air conditioners of 1.5 / 2 capacity all as directed.
S & F in replacement, PVC connection wire woven 15mm size with nickel plated brass adapter, both sides threaded, in standard length of 600 mm to suit the size of geysers complete all as specified and directed by Engineer-in-Charge.
M & L lagging to 15mm bore galvanized iron tubing used in internal water supply or plumbing all round with 25mm thick banded mineral wood preformed “SNAPON” pipe sections of density 144 Kg/Cum conforming to IS-9842 including provision of chicken wire mesh netting 25 gauge, 20mm mesh and finally covered with 0.01mm aluminium foil complete all as specified and directed by Engineer-in-Charge.
M & L lagging to 20mm bore galvanized iron tubing used in internal water supply or plumbing all round with 25mm thick banded mineral wood preformed “SNAPON” pipe sections of density 144 Kg/Cum conforming to IS-9842 including provision of chicken wire mesh netting 25 gauge, 20mm mesh and finally covered with 0.01mm aluminium foil complete all as specified and directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300V with output voltage stabilized at 230 V with accuracy of ± 2.5% can operate upto 12 Amp and above capacity 15 Amp all as specified and directed by Engr-in-Charge.
Dismantling and opening up the defective Voltage Stablizers of capacity 5.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 69.00 above but capacity of 3.0 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of buck/boost relay rating 25 Amps as per existing pattern suitable for voltage stabilizers 5.0/3.0 KVA complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 71.00 above but relay rating 08/05 Amps as per existing pattern suitable for voltage stabilizers 1.0/0.5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of PCB assembly complete with necessary accessories suitable for 5.0/3.0 KVA capacity voltage stabilizers as per existing model complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole 32 Amp (B-32) 240 volt with rupturing capacity not less than 9 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement GI union of 15mm bore, ISI marked complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 75.00 above but 150mm x 10mm complete all as specified and directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tank 500 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked and having two layers and white colour )
M & L for painting to metallic desert cooler any capacity with one coat of synthetic enamel paint inside and black bitumenus paint in side of bottom of water starage tank and balance portion synthetic enamel paint over a coat of red oxide primer including preparing the existing painted surface as per required patching works . Colour shall be as per existing shade complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. Note : (i) PVC cable and PVC conduit shall be ISI marked. (ii) Two run of cable, one run of earth wire and PVC conduit shall be measured as one unit.
Supply and fixing of water drain out pipe for ACs size as per existing on site all as specified and directed by Engr-in-Charge.
M&L for repair of electronic fire alarm panel with chagne of wiring kit and replacement of PCB, commissioning required after repair, all as specified and directed by Engr-in-charge.
M&L for complete servicing of central AC plant of capacity 3 x 11 TR (installed at 16 RAPID Div HQ, Ops room) cleaning with soap water and carbon tetra chloride to the cooling coil, oiling, greasing to blower motor and pumps , during service of unit existing refrigerant gas will pump down and store to re-use , cleaning of air filters and condenser unit all components comprising of following :-
Compressor 11 TR capacity - 03 Nos
Shell & tube type condenser - 03 Nos
AHU with electric driven motor - 01 No
FRP cooling tower - 01 No
Monoblock pump set for condenser - 06 Nos
M&L for gas charging in scroll type semi hermatic compressors capacity of 11 TR (refrigerant type R-407/410) including checking of all electrical connections , burnt out thimbles , and testing of plant all as specified and directed by Engr-in-Charge.
Taking down dismataling and opening of the compressor (Make : Voltas) for over hauling , cleaning, , washing , machining and mechanically repair work etc. checking of its all parts of serviceability / unservicability and reassembling all servicable parts all as per original and replacement of defective parts as reqd for smooth functionning of the compressor and testing after erection it in original position to the entire satisfaction of Engr-in-Charge. (Note:- (i) all defective / unserviceable spare parts / items reqd for overhauling /defective sensor shall not be paid separately.
S&F for thermostatic bio-metal fuse for fridge capacity of 210 ltr to 320 ltr all as specified and directed by Engr-in-Charge.
S&F in replacement fan motor for deep freezer capacity upto 320 Ltr, motor load capacity 16 watt all as specified and directed by Engr-in-Charge. --------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 38826.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page Nos 27 & 28 (Schedule of Credit) of Tender document
Ganganagar Enterprises
Ankit Jindal And Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .