Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | ₹2.2 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹2.3 Cr+₹5.2 L (2.31%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | ₹2.3 Cr+₹5.2 L (2.31%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹2.3 Cr+₹6.8 L (3.02%)Rejected-Finance 1 1 NORTH ROAD JADAVPUR KOLKATA | KOLKATA | WEST BENGAL | ₹2.3 Cr+₹6.8 L (3.02%) | L3 | Rejected-Finance REJECTED |
| 4 | L4₹2.3 Cr+₹7.7 L (3.45%)Rejected-Finance 76 CRIPER ROAD KONNAGAR HOOGHLY | KONNAGAR | HOOGHLY | WEST BENGAL | ₹2.3 Cr+₹7.7 L (3.45%) | L4 | Rejected-Finance REJECTED |
Tender Value
Refer Docs
EMD Value
₹4.8 L
Closing Date
2 Feb 2021, 2:00 pmClosed
EXECDUTIVE ENGINEER BOLPUR MECHANICAL DIVISION PHE
SRINIKETAN ROAD NEAR HOTEL MARK MEADOWS PO SRINIKETAN DIST BIRBHUM PIN 73123
Supply and installation of HT equipment and other allied works of PWSS for Suri I Suri II and Sainthia Block
2020_PHED_311595_1
PHED/10/EE/BOLMD/2020-21
Open Tender
MECHANICAL
Item Rate
120 days
SURI BIRBHUM
Please refer Tender documents.
6 documents required · 6 mandatory
₹4.8 L
BOLPUR
26 Feb 2021
29 Dec 2020
4 Feb 2021
30 Dec 2020
2 Feb 2021
30 Dec 2020
14 Jan 2021
Amount
Supply and delivery and storage at site the following Specification :- H.T. automatic voltage regulator with following specification : Capacity – 400 KVA, Cooling and insulation – ONAN, Contract type – Rolling Contact Conductor materials : Electrolytic grade copper, Lamination : CRGO Silicon steel, Duty : Continuous, Controller – Step less load, Operation – Auto / manual Service - Indoor Type, Input Range – 7KV-12KV, Output Range – Stabilized at 11KV ± 1% with 3Φ 50HZ Balanced or unbalanced load. Max temp, rise - 35ºC rise of oil temp over an ambient of 50ºC . Tank – Should have two separate tank one for step up/down units with beck booster transformer and other for voltage regulator unit. Oil – should be provided with first filling as per – IS335 .
H.T. Automatic Voltage regulator with following specification :- Capacity – 250 KVA, Cooling and insulation – ONAN, Contract type – Rooling Contract. Conductor materials : Electrolytic grade copper, Lamination CRGO Silicon steel, Duty - Continuous, Controller – Step less load. Operation –Auto/Manual Service – Indoor Type. Input Range – 7 KV-12 KV, Output Range – Stabilizer at 11KVI 1% with 3 Φ 50 Hz balanced or unbalanced load. Max temp, Rise - 50ºC rise of top oil over an ambient of 50ºC. Tank – Should have two separate tank on for step up/down units with back booster transformer and other for voltage regulator unit. Oil – Should be provided with first filling as per – IS335
12 KV 26 KA 630A single panel horizontal draw out type vacuum circuit breaker with all relay and meter suitable for above AVR with following specification :- VCB – Manually draw out type with motorized spring charging mechanism suitable for 230V AC and closing tripping coil with 110V DC. Service - Indoor
Supply delivery and storage at site 11KV(E) grade 3 core 185 sq mm XLPE insulated aluminum conductor armoured cable conforming to IS7098 Part – II. (for 250 KVA AVR).
Supply and delivery and storage at site 11KV (E) grade 3 core 240 sq mm XLPE insulated aluminum conductor armoured cable conforming to IS7098 Part – II. (for 400KVA AVR).
Providing GI Rack/Tray for laying of H.T cable inside the substation room (for above AVR & VCB). (300 mm X 50 mm)
Providing curb angle & removable chequerred plate over the open portion of the cable trench after installation of the equipments as per direction of the EIC. & with a provision of lifting lug over the MS chequerred plate. (After above AVR & VCB)
Indoor type heat shrinkable H.T. Termination kit suitable for the above cables two for power cables and two for inter connection between AVR Tank.
240 sq mm Joint kit
185 sq mm joint kit
Installation of the above materials i.e. AVR, VCB at site on the existing position part by part including making suitable frame for HT panel with grouting of the equipments complete the job as per direction of EIC
Earthing of the above AVR and HT panel using 50 mm dia electrode and electrolytes as per IE rules and as per direction of EIC
Supply and delivery of 65 mm x 8 mm GI Strip for earthing purpose
Laying the above new H.T. 11KV (E) 240 sq mm x 3 core and 185 sq mm x 3 core al. Ar. Cable with two site jointing of the cable with cutting the trenchers as per IE rules with dressing and ramping the same after laying the cable by manual labour and expert jointer complete the job as per direction of EIC
Commissioning and testing of the system installation above in of manufacture authorized service personal complete the job as per direction of EIC
Supply delivery and storage at site (Raw water) of the following XLPE insulated armoured 1.1KV grade Al. conductor cable :-
150 sq mm, 3 core, 1.1 KV grade XLPE armoured Al. cable (Transformer secondary to incomer MCCB’S – 2 feeder with 2 length per feeder.)
16 sq mm x 4 core 1.1 KV grade XLPE armoured Al cable (for lighting, Ventilation etc. 1 length per feeder, 2 feeders).
10 sq mm x 3 core 1.1 KV grade XLPE armoured al. cable (for battery charger, valve actuator ECBC etc.). (1 Length per feeder).
6 sq mm x 2 core 1.1 KV grade XLPE armoured Al. cable for various single phase supply.
Supply and delivery and storage at site of 1.1 KV grade 6 core PVC insulated 2.5 sq mm stranded copper conductor armoured control cable conforming to relevant I.S
Laying of the above new cable in an underground trench in single tier formation horizontal the trench size 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 Nos. brick per mtr. And 4 Nos. brick per mtr. As separated between the cables including filling the space between the bricks and cable and also the trench with shifted Soil, Leveling up and restoring surface duly rammed.
Full Bore Electromagnetic Flow meter _Raw Water, Full Bore Electromagnetic Flow meter - DN 400, Protection: IP68 (Minimum inbuilt 25 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART/Modbus Output and Totalizer Pulse Output: 0.05cu.m/Pulse) With LCD Display, Calibration lab as per ISO 17025 , Accuracy: 0.5% , +/- 2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner ,Supply: 24V DC/230 V AC
Supply delivery and storage at site 400 mm dismantling joint. PN-1.0
Construction of RCC pit of suitable size with manhole / removable cover for installation of common delivery header flow meter with DM Joint including supply of all material, labour, shuttering, excavation, back filling complete.
Chlorine Measurement (Clear Water) Analyzer with pH Compensation: (Clear Water Pump House), Electrode, Digital functionality with Inductive Data Transmission from Sensor to Transmitter, Diaphragm: PTFE , Signal transmission: Digital. Reference system: Gel., Conductivity: min 50uS/cm , Temperature sensor integrated. Transmitter liquid analysis for Digital pH and Chlorine, Digital sensors; Digital protocol, In built Digital Display, Input: 2x Digital Sensor, Output: 2x 4-20mA , Supply: 230VAC/24V DC Plug &Play for sensors modules, SD-slot data logger, alarm relay, Protection: IP66, Input: 2x Digital Sensor, Output: 2x 4-20mA , Supply: 24V DC, Flow Fit Assembly along with Standing Sample Handling Panel
Pressure Transmitter for Clear water Common Header: (Clear Water Pump House) Application Area: CLEAR WATER PUMP, COMMON HEADER=1, Piezo Resistive Sensor Type, Measuring membrane: Ceramic. Linearity +/-0,5%. Range: 0-10BAR Output: 1Chx4-20mA, SIL, 0.1% Accuracy, Connecting Cable: Plug M12 10 meter, IP67, Process Connection: Thread ANSI MNPT1/2, Protection: IP68 .
Chlorine Measurement (OHR) Analyzer with pH Compensation: (OHR Site) : Electrode, Digital functionality with Inductive Data Transmission from Sensor to Transmitter, Diaphragm: PTFE , Signal transmission: Digital. Reference system: Gel., Conductivity: min 50uS/cm , Temperature sensor integrated. Transmitter liquid analysis for Digital pH and Chlorine, Digital sensors; Digital protocol, In built Digital Display, Input: 2x Digital Sensor, Output: 2x 4-20mA , Supply: 230VAC/24V DC Plug &Play for sensors modules, SD-slot data logger, alarm , relay, Protection: IP66, Input: 2x Digital Sensor, Output: 2x 4-20mA , Supply: 24V DC, Flow Fit Assembly along with Standing Sample Handling Panel .
Installation of the above item covered in Sl. No. 9 to 14 including supply of installation & connection materials part by part on the OHR site by expert mechanic complete the job as per direction of EIC
Commissioning and testing of item covered in Sl. No. 9 to 14 with PH compensation by smooth operating system by expert mechanic complete the job as per direction of EIC
Add: GST @ 12% on sum of Item No: 1 to 23
Add Cess @1% on sum of Item No. 24
WEST BENGAL ENGINEERING CO.
MACHINE SUPPLIERS SYNDICATE PVT LTD
MAHADEV ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .