| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC | ₹6.4 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹6.5 Cr+₹15.0 L (2.35%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹6.5 Cr+₹15.0 L (2.35%) | L2 | Rejected-Finance Quoted rates higher than L1 |
| 3 | L3₹6.6 Cr+₹22.6 L (3.54%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹6.6 Cr+₹22.6 L (3.54%) | L3 | Rejected-Finance Quoted rates higher than L1 |
| 4 | L4₹6.7 Cr+₹33.0 L (5.16%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹6.7 Cr+₹33.0 L (5.16%) | L4 | Rejected-Finance Quoted rates higher than L1 |
| 5 | L5₹6.7 Cr+₹34.4 L (5.38%)Rejected-Finance | ₹6.7 Cr+₹34.4 L (5.38%) | L5 | Rejected-Finance Quoted rates higher than L1 |
Tender Value
₹6.8 Cr
EMD Value
₹6.7 L
Closing Date
18 Nov 2023, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Provn of 1MWproof top solar power generation system under GE AF Sulur
2023_MES_623062_1
CWE(AF)TVM/82471E8 1 MW roof top solar sulur
Open Tender
Miscellaneous Works
Item Rate
365 days
Sulur
Class A MOU with Solar power firms as per NIT
8 documents required · 8 mandatory
₹3,000
GE AF Sulur
₹6.7 L
Yes
6 Feb 2024
13 Oct 2023
20 Nov 2023
13 Oct 2023
18 Nov 2023
4 Nov 2023
14 Oct 2023 - 31 Oct 2023
Amount
SCHEDULE 'A'
Material and labour for designing , installing , testing , synchronization and commissioning of 1 MWp On grid solar roof top solar power generation system along with module mounting structure comprising of the following:- BIS certified and MNRE ALMM Registered, DCR Mono Crystalline PERC Half cut cells solar PV module/panels suitable for installation on roof tops with each panel having capacity not less than 540Wp complete with poly carbonate junction boxes, having sufficient number of fused incomers and outgoing terminals (positive/negative) suitable for 6 Ssqmm cables and connecting cables not less than 2.5 Sqmm copper conductor multistranded (solar cross linked poly olefin cables double insulated , UV resistant halogen free low smoke ) from panel to panel all as specified and directed. All modules will have minimum 25 years OEM linear output warranty. (a) Output power (Pmax) 540 Wp or above. (b)Module Efficiency: Not less than 22% c) Number of cells: 72 Nos full cells (144 half cut cells) (d) Maximum System Voltage : 1500 Vdc (e) Application Class - A (f) Fire Class - A (g) Junction Box: IP 67, 1.5 kV 1000 mm length cable. (h)Type of PV Cell: Mono Crystalline Silicon (i) Module Glass transmission shall be > 93 % (j) Glass Thickness shall be min 3.2 mm (k) Each PV module used in any solar power project must use a RF identification tag (l) Bypass diode for optimizing PV out to be incorporated in each solar module (m) Module Output: MC Electronic Plug (n) Modules only with Same rating and manufacturer shall be connected. (o) Solar Module must have IV curve Test report in NABL Lab for the specified wattage (p) Entire B&R scheme (mounting structure etc) and E &M scheme (from solar module till generation of electricity i.e solar modules, strings, string inverters, transformer, SCADA etc) shall be submitted by contractor (or his consultant) as per requirement of MNRE CE and further vetted by IIT/ NIT and for approval of Accepting officer. (q) DCR :- Domestic content requirement (DCR) mandates shall be strictly adhered i.e, for the use of solar cells and modules etc shall be manufactured domestically as per specifications and testing rquirements fixed by MNRE.
(i)Module Mounting Structure :- Design, Supply and install prefabricated roof top solar panel mounting structure made of Hot deep galvanized steel angles/channels/flats including nuts/bolts and washers suitable for wind resistance upto 160 Kmph including necessary PCC foundations of grade Type B1 - 1:2:4 using 20 mm graded stone aggregate at suitable points to provide for a stable robust support all as directed at site all as specified and directed including designing of Suitable mounting structure for SPV Module and shall be provided as per design criteria considering live load, dead load, wind load and as per condition of roof slabs/ foundation of existing Bldgs etc by a approved structural Engineer and vetted by NIT/IIT and approval by Accepting officer before execution at site. a)Structures shall be of flat-plate design using minimum size of C (75 x 40 x 5mm) or L (55 x 55 x 5mm) or I (60x 40x 4mm) or C LIP (75x54x15x2mm) sections or higher dimensions for respective sections. b)Each structure with fixed tilt should have a tilt angle as per the site conditions to take maximum insolation which will be approximately equal to the latitude of the location south ± 20ᵒ as per the site condition with North - South orientation. c)The PV module mounting structure shall have a capacity to withstand a wind velocity of 160 Kmph unless specified for dedicated requirements d) The materials used for structures shall be Hot dip Galvanized Mild Steel conformed to IS 2062:1992. e)The minimum thickness of galvanization for hot dip Galvanized Mild Steel should be at least 80 microns as per IS 4759. f)The Bolts, Nuts, fasteners, and clamps used for panel mounting shall be of Stainless-Steel SS Grade. g)Additional Structures/Frames for required for the installation of modules if any need to be provided by the Contractor. h) The structures shall be designed to allow easy replacement of any module, repairing and cleaning of any module. i) The structure shall be designed to withstand operating environmental conditions for a period of minimum 25 years. And shall be free from corrosion while installation. j) Minimum distance between the lower level of PV Module and the ground shall be 0.5m from the ground level. k) The structures should be suitably loaded with reinforced concrete blocks of appropriate weight made out of M25 concrete mixture. l) Photovoltaic must be mounted on a stable, durable structure that can support the array and withstand wind, rain, and other adverse conditions. The modules will be fixed on structures with fixed arrangement. (m) 100% indigenous company (n) The details of foundation alongwith structural drawings of each bldg will be handed over to contractor by department. The ccontractor has to submit the schemematic drawing obtained from consultant showing No of solar mounting structure with panels etc to NIT/IIT for ascertaining the structural stability of the building. The same shall be got vetted from NIT/IIT before commencement of work.
Special Note :- (1) The work involves provision of roof top panels in all maint support group complex (MSG) buildings, contractor should visit the site before quoting the tender. (2) Suitability for Grid Connected System. (3) PV Modules & Solar Cells shall be made in India and makes and manufacture by India Only. The contractor shall submit all required documents . The panel should be of latest edition. (4) Power Warranty - 10 year warranty on 90% of the design output and 25 years warranty on 80% of the design output as per MNRE ALMM registered. . (5) TANGEDCO registration fees, all the fees related to commissioning should be borne by the Contractor. (6) Work shall be executed as per TANGEDCO & CEIG norms. (7) All materials makes shall be approved as per MNRE, TANGEDCO. (8) Contractor Should have valid TEDA Empanelment Certificate. (9) No drilling is allowed on the roof slabs. Existing structures shall not be damaged, if any damage shall be rectified by contractor without any extra cost as original as directed by Engineer-in-charge. (10) Each PV module must have RFIO TAG which contain Name of manufacture of PV module, solar cells & month and year of manufacturing, I-V curve for module, peak voltage, Im , Vm, FF, Unique serial No, Name of test lab issued IEC. (11) Liaisoning with TANGEDCO authority for obtaining any relevant documents/approved of installation solar power plant to Grid from TANGEDCO for smooth functioning shall be contractor responsibility. (12) Feasibility clearance from state electricity board: Rate quoted by bidder is inclusive charges for feasibility clearance and Liaison work regarding the plant from starting to commissioning with TANGEDCO will be done by the contractor and plant will be taken over after it is fully functional including Installation of Energy Reading meter and certified BY TANGEDCO. (13) Standby supply shall be provided by contractor without any extra cost to department at the time of Synchronizing with existing 11 KV system. (14) Technical feasibility report shall be obtained from TANGEDCO before starting work in ground. (15) Capacity of Invertor shall be as per design criteria and approved by Accepting officer. (16) String Inverters only to be use for this project. (17) Solar meter and Bi-directional meter : Supply HT net meter / Bi-directional meter and solar meter to deposit to TANGEDCO for testing and calibration thereafter taken back to site for installation. Contractor will not be claim extra cost from department for carried out of above said process. (18) Blank. (19) The Bidder shall carefully design and accommodate requisite numbers of the modules in each buildings to get the design output as per topography. Also ensure sufficient circulation/movement area on the roof top for the maintenance and cleaning purpose all around. (20)Necessary Parapet Wall may be ensured of each Building for the protection of Men (21) Contractor shall maintain the solar plant by employing 2 well experienced technician in handling SPV for 24 hrs upto 2 years from the date of completion of work . The necessary labour wages etc are deemed to be included in quoted rate.
Inspection of TANGEDCO electrical Inspector: Rate quoted by bidder is inclusive Electrical inspector inspection charges to State electricity department by Sr Electrical Inspector. Contractor is bound to arrange all the documents/ inspection reports/ test sheets in prescribed format by TANGEDCO on their official website & pay charges for inspection after successfully installation of the solar power generation systems. No extra payment will be made in this effects. Note : After successfully installation of system, Contractor will submit inspection reports duly signed by Chief Electrical Inspector of TANGEDCO to MES for buyback agreement with TANGEDCO. If the Power will not generated at a correct level /limit , a penalty will be charged against contractor as decided by accepting officer
GENERAL NOTES : The items of work mentioned in item above of this schedule shall be executed as per following:- (a) The above item shall be quoted and executed on roof top based on Contractor’s own design on Performance Guarantee Basis. The Performance Guarantee is related to achieving the 1 MWp generation with specified efficiency and efficacies. The Contractor shall also be responsible for desired operational efficiency and desired efficacies of the System during its life cycle of minimum 25 years. (b) The design shall be got vetted from any one of the following agencies(Approved Agencies):- (i) National Institute of Solar Energy (NISE). (ii) Sardar Swarn Singh National Institute of renewable energy (iii) Solar energy corporation of India(SECI). (iv) The Indian renewable energy development agency (c) The successful Contractor shall submit the following document duly vetted by any one of the approved agency, within Four weeks of placement of work order for approval of Accepting Officer. (i) Design Calculations : The tenderer should work out design based on the conditions prevalent at Air Force Station sulur ground situation and site conditions as existing. (ii) This shall be self contained and self explanatory representation of layout of equipment's and sub-system. The dimensioned drawing of the site of work clearly marked with all subsystems components etc shall be submitted. (iii) Schematic Diagram of the electrical system: This shall contain specifications, sizes, current, voltage and fault levels rating of all cables, switch gears and instrumentation & control systems and all metering and interlocking etc. (iv) Blank (v) All the documents/ technical details mentioned above duly vetted as specified above shall be approved by Accepting officer before placing final order. The GE may approve the document with concurrence of Accepting Officer as submitted by contractor or may suggest modification/ alteration in documents/ technical specifications duly supported with reasons for the same. The work shall be executed based on the approval. (vi) The design drawings and other technical details submitted by the successful contractor, along with all calculations, drawings, technical write ups etc shall become department property. Department may use these subsequently as deemed necessary. The contractor shall have no claim on these document and their subsequent use by the department. (d) During execution the contractor must engage experienced engineer in the same field for supervision, monitoring and execution. The contractor shall certify that execution of the work has been done satisfactorily. The contractor shall certify that the work has been executed in accordance with vetted and approved design. All cost and charges for engagement of consultant shall be born by the contractor. (e) Department will give completion of the work to the contractor only on the basis of basis of completion report submitted by the consultant engaged by the contractor for design. (f) After Execution of project the contractors will verify generation of electricity as per vetted design in the PVSYST/PVSOL report submitted and connection of the same with existing power supply network. (g) The contractor shall ensure suitable arrangement for solar PV panels.
Design ,supply , install testing and commissioning of Data Logger (SCADA) with Online Monitoring Portal all as specified and directed with the following features:-. a) Solar Irradiance: A Pyranometer/ Solar cell-based irradiation sensor (along with calibration certificate) shall be provided, with the sensor mounted in the plane of the array. b) Temperature: Integrated temp, sensors for measuring the module surface temp., inverter inside enclosure temp, and ambient temp to be provided complete with readouts integrated with the data logging system. (c) It is recommended that the following important parameters shall be accessible through the Data Logging Facility. i) AC Voltage ii) AC Output current iii) Output Power iv) Energy in kWh v) DC Input Voltage vi) DC Input Current vii) Temperatures (C) viii) Invertor Status ix) Irradiation x) Module temperature xi) String Voltage & Current" (d) All Communication and Control Cables as per the design. ( e) Contractor shall install one PC( latest configurations) with printer and other required accessories to monitor real time solar data at a designated place as directed by GE. Note :- (i) Since the work lies in tech area, necessary permission have to be taken from user for internet connection. Contractor has to submitt all the necessary documnets to GE for obtaining permission from the user unit befor installation. (ii) The data logger (SCADA) system will be maintained by the contractor up to 24 months from the date of competion.
Design , supply, install , testing and commissioning BIS certified and BIS approved IP65 rated on grid inverter suitable output for 1 MW, natural cooled, suitable for ambient temperature range 0 to 60 deg Celsius, 50/60 Hertz frequency, with anti islanding features, having three phase AC output with inbuilt surge protection devices, Anti reverse power controller, fuse protection, DC/AC switches, LCD display for generating data, Wi-Fi/GPRS data logger, multiple MPPT for optimum generation, wide input voltage range all as specified and directed by engineer in charge. Note:- Only string inverter can be used, number of inverters will be based on design submitted by the bidder through MNRE CE duly vetted IIT/ NIT and approved by Accepting officer.
Minimum Requirement and specification for on grid inverter :- (a) For initializing the Inverters from the sleep mode, it is important that there is sufficient sunlight and that the Utility Grid is available. Sufficient sunlight in the morning is needed to provide adequate power to the inverter so that it could start up from the over night sleep mode. Availability of the Grid is required to the inverter as it has been programmed to a logic and a pre-set window of Grid voltage and frequency. If the available Grid has all these qualities for which the inverter is designed, it would initialize the main out put contactor and couple with the Grid and start evacuating the power to the Grid it is coupled with. In case the Grid fails due to any reason, the inverter should come to idle mode till the Grid comes back again. Even during the power evacuation, if the sun light falls below the desired limit, due to clouds etc., the inverter also stops working, although the Grid is available, till it starts getting the desired solar power required to power the Inverter it self. (b) If the power evacuation goes on till the evening the inverter should keep on getting the desired solar power which is in excess of the power needed to operate the inverter itself. As soon as It attains the power which is just sufficient to run the inverter, the power evacuation stops and only the inverter keeps running till the power drops further low due to decreasing sunlight in the evening, resulting in the inverter going to sleep mode to initialize again automatically the next morning. (c) A record shall be maintained with input from inverter in the event of failure of the utility grid resulting in inverter going to sleep mode and stop generating power. (d) The PCU / Inverters should be tested from the MNRE approved test centres/NABL/BIS/IEC accredited testing-calibration laboratories.+C50:C59C50:C61C50:C62C50:C61C50:C60C55C50:C57C50:C59C50:C60C50:C61 (e) Inverter Manufacturer should supplied and installed minimum of 10 MW cumulative capacity of inverter in last 5 years in India (f) Minimum efficiency 98.5%. (g) The DC to AC ratio not grater than 1.25 is to be maintained at all sites. (For eg. – For DC capacity of 100 kWp, the AC capacity of minimum 80 kW is to be maintained). (h) The PCU shall have a higher degree of ingress protection of IP 65 to handle robust environment conditions from dust and water ingress under complete outdoor installations. (i) The data logger should possess the feature of extracting the data externally with open protocols like Modbus TCP/RTU. The manufacturer should provide the Modbus register mapping file to utilise this feature (j) Specifications: (i)Nominal voltage - 680 to 880 V (ii)Voltage Band - Between 80% and 110% of V nominal, pollution degree-IV (ii)Nominal Frequency - 50 Hz safety class (iv) Operating Frequency Range - 47.5 to 50.5 Hz (v)Waveform - pure Sine wave (vi) Harmonics -AC side total harmonic current distortion < 3%
Minimum Requirement and specification for on grid inverter (contd/-...):- (vii) Ripple - DC Voltage ripple content shall be not more than 1% (viii) Casing protection levels - Degree of protection: Min IP-65 (ix) Operating ambient Temp range: -10 to + 60 degree Celsius (x) RH : 0-100% non condensing" (k) Protections: (i)Reverse polarity protection (ii)Over voltage: both input and output (iii)Over current: both input and output (iv)Over / Under grid frequency (v)Over temperature (vi)Short circuit (vii)Lightning (viii)Surge voltage induced at output due to external source (ix)Islanding (x) Ingress Protection - IP 65" (l) Communication Interface : RS485/ RS232/Wi-Fi (with or without USB) (m) Synchronization: Photovoltaic system must be equipped with a grid frequency synchronization device, if the system is using synchronizer inherently built in to the inverter then no separate synchronizer is required (n) DC Injection: Photovoltaic system shall not inject DC current greater than 0.5% of full rated output at the interconnection point or 1% rated inverter output current into distribution system under any operating conditions. (o) Power Factor: While the output of the inverter is greater than 50%, a lagging power factor greater than 0.9 shall be maintained.
Supply,Installation,testing and commissioning DC distribution boards (Array Junction Box) ,IP 65,suitable for roof top solar generation system of rating upto 250 KW, 1500 volts, 8 incomer and 8 outgoing with DC surge protection device 1500 V ,DC fuse 30 A -8 Nos and MCBs for Eight string network. The DB will be having terminals suitable for 4/6 Sqmm copper conductor cables and the enclosure for the DB shall be made of FRP/ABS with IP65/66 protection all as specified and directed by engineer in charge . Note : (i)DC panel should be equipped with an adequate capacity, DC circuit breaker along with control circuit, protection relays, fuses. (ii) DCDB shall have sheet from enclosure of dust and vermin proof, the busbar/ cables are to be made of copper of desired size. DCDB shall be fabricated to comply with IP 65 protection.
Supply ,Installation, testing and commissioning ACDC Breaker, Outdoor type,IP 65 Protected with following specifications:- - Breaker- 800V, 4P, 200 Amp - 1 No( Outgoing to LT Panel) - RYB Indicator lamps - Double compression - Glands for Inputs, Double Compression glands for output - Enclosure CRCA Powder Coated PU Paint - All Input and Output lugs (Cu & Al lugs as per cable type)
Desgin,fabrication ,Supply ,Installation, and commissioning Outdoor type Solar power isolation LT panel double door (CPRI Approved) IP65 made of powder coated CRCA sheet steel 3.15 mm with necessary Floor mounted MS Channel frame made of 100x100x10 mm duly painted with one coat of primer and two coats of synthetic paint including necessary PCC foundation. The panel board shall have the following switchgear enclosed within :- (a) Adjustable thermal and fixed magnetic setting type MCCB 4 Pole, 800 V, 200 Amps, 36 KA rating – 05 Nos ( as incoming from AC Breakers) b) Aluminium busbars TPN 800 volt, 1000 amps rating c ) Electric Draw Out ACB 4 Pole,50 KA, 800 V, 1000 Amps rating – 02 Nos ( as outgoing )(01 Main and 01 Spare) LT,Air Circuit Breaker, operational voltage 660 Volt,Insulation voltage 1000 Volt,AC,50 Cycles,3 phase,4 pole, Electrical draw type, rated current rating 1000 Amps and of breaking capacity 50 KAw with quick make, quick break, with auto/manual operating mechanism,microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating "Trip Healthy Circuit" ancillary switch etc complete over load release rating 2500 Amp d) Energy meter for measuring solar energy output with CTs and PT Based e) Cable glands for armoured LT cables f) Surge protection device ,4 Pole Type I and Type II of Capacity ,Iimp 8 KA/Pole max 32KA (g) Muliti function Microprocessor Based Meter-01 Nos
Supply,Installation,Testing and Commissioning of HT panel with Vacuum Circuit Breaker panel board, factory made, outdoor type, metal clad, totally enclosed, free standing floor mounting type HT 11 KV, 3 Phase, 4 wire, 50 cycles, AC supply system suitable for housing trolley mounted vacuum circuit breaker, horizontal isolation and horizontal draw out type, cubicle fabricated out of CRCA sheet 3.15 mm thick weather, dust and vermin proof, epoxy powder coated, of IP-65 protection class of IS-2147 with self contained air insulated compartments for bus bars and cable boxes with necessary supports and 800 Amp rated Aluminium bus bar including cable galleries, interconnecting bus-bar connection/ linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance with IS-13947 (Part-1) 1993 & IS-8623 and all as specified and directed by Engineer-in-Charge.
Supply,Installation, Testing and Commissioning of step up transformer out door Suitable for plinth mounting complete with standard accessories or fittings suitable for Inverter voltage / 11 KV (at no load) AC, 3 phase, 50 cycles, 4wire, capacity 1250 KVA double copper wound, immersed C R GO core type naturally cooled, built-up with class "A" Insulation conforming - IS-1180 (Part-1) 2014 (Level-III) Including amendments as an the date of receipt of tender with following requirement:- (a) Continuous Rating : 1250 KVA (b) No Load Voltage ration : 800/11kV (c) Taping on HV ) +/- 7.5%, +/- 5%. +/- 2.5 % (d) Phase and Frequency : 3 phase & 50 Hz (e) Vector Group: As per Design (f) Cooling: ONAN (g) Type : Outdoor "h) Terminal management: HV Side: Quad furcating cable box with 03 Nos bushing type terminal for connecting HT XLPE cable and 01 No for earthing LV Side: Bus Duct" (i) First filling of new and unused conforming to IS-335-1993 (fourth revision) shall be marked, filtered and tested upto 50 kV di electric strength at 2.5mm air gap between testing electrodes
item No.9 Contd/-:- (j) Fittings: (i) Externally Hand Operated Off - Circuit tap switch with position indicator and locking arrangement device. (ii) Conservator with oil gauge, filling hole with plug and drain hole with plug. (iii) Undercarriage with four plain rollers. (iv) Lifting lugs for core. (v) Earthing terminals. (vi) 150mm Oil temperature indicator with alarm and trip contacts, (vii) 150mm Winding temperature indicator with alarm and trip contacts. (viii) OCTC(Off circuit Tap Changer) (ix) Buchholtz relay-01 No. (x)TOP Filter valve with plug. (xi) Rating plate with diagram plate. (xii) Lifting lugs for transformer. (xiii) Oil-Filling hole cum air release plug. (xiv) Drain valve cum sampling valve. Thermometer Pockets. (xv) Silica Breather. (xvi) Marshalling Box with double window.
Supply, Fixing, Testing and Commissioning UV protected XLPE/XLPO Solar Grade copper Cable of size,PVC insulated 1 Core 4 Sqmm with DC Connectors (male & female) pair MC4, 1.5 kV Volts rated all as specified and directed by engineer in charge.
Supply, Fixing, Testing and Commissioning UV protected XLPE/XLPO Solar Grade copper Cable of size,PVC insulated 1 Core 6 Sqmm with DC Connectors (male & female) pair MC4, 1.5 kV Volts rated all as specified and directed by engineer in charge.
Supply and laying High density polyethylene pipes 50 mm dia (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc
Supply and fixing Trunking GI cable tray of size 150 mm width, 50mm height, thickness 2mm with cover of size 155mm width, 12mm height, 2mm thickness and accessories (any type of Joint and Bends) with fittings (Channel, fasteners, anchor bolt) complete all as specified and directed.
Supply, Laying, Testing and Commissioning cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 300 sq mm 3.5 core with Consumables like Lugs, Ferrules, Cable Ties, uPVC tape, uPVC saddle, Cable clips etc. complete all as specified and directed.
Supply, Laying, Testing and Commissioning cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 1000 sq mm Single core with Consumables like Lugs, Ferrules, Cable Ties, UPVC tape, uPVC saddle, Cable clips etc. complete all as specified and directed.
Supply, Laying, Testing and Commissioning cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 185 Sqmm ,3 Core core and with Consumables complete all as specified and directed.
Supply and Laying of Aluminium bus duct from LT panel to Transformer as per the current rating of LT panel and TANGEDCO Specification complete all as specified and directed.
Material and labour earthing with GI earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to GI strip of size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 X 6 mm galvanised iron strip ,Strip will be fixed by epoxy insulators without making hole at the distance of 60 CM from each other complete all as specified and directed. Note - Earth strip shall be connected by Welding Only.
Material and labour for air termination rods with 40mm light grade pipe 1.5meters long, with 300 mm long, 6mm dia copper rod clamped at one end and base of pipe embedded in PCC foundation of grade 1:3:6 of 20 mm grade aggregate on roof slab complete all as specified and directed.
Test Point terminal block made of gun metal or phosphor bronze size 75mmx75mmx 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 min depth for laying of UG cable and getting out in hard soil complete all as specified and directed. Note- Excavation shall be done by Manual process.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of excavated soil complete all as specified and directed.
Removing excavated material to a distance not exc 50 m and deposited where as directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV,type 1,ISI Marked, Factory manufactured, size 250 mm x 150mm x 40mm complete all as specified and directed.
Supply and Spread Natural riddled soil in trenches for cushioning and covering to cable complete all as specified and directed. Note: (i) Natural soil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 cm and 15cm after laying of cable. This is then gently punned down to a depth of 10cm above the top of upper-most cable. (ii) For the purpose of measurement only punned thickness only will be considered for payment.
Supply and laying High density polyethylene pipes(HDPE) of 32 mm dia pressure rating 6 kgf/cm2 laid in trenches and fixed on poles complete all as specified and directed.
Material and labour Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M & L for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable route marker welded to angle iron 40 x 40 x4 mm thick fixed in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate including necessary earth work, form work etc complete all as specified and directed.
Supply and fix Fire extinguisher ABC Type of capacity 4 Kg complete all as specified and directed.
Supply and fix Fire Bucket Stand with buckets -03 Nos complete all as specified and directed.
Supply and fix Rubber Mat of size 2 Mtr x 1 Mtr of Thickness 2 mm ,ISI Marked complete all as specified and directed.
Design and Supply of Backup source for SCADA & Internal lighting as per Design (Min 5 KVA with 3 Hours Back up) complete all as specified and directed.
External Water Supply
Supply and fixing of HDPE Rotational moulded polyethylene water storage tanks Capacity 2000 ltr (Cylindrical vertical with closed top) hoisted and fixed in position as per ISI Masked IS 12701 / 1996 all as specified in SSR Part -I complete all as specified and directed.
Supply and Fixing of Solar module water cleaning system kit for the 1000 KW solar power plant system for complete proposed Buildings. Complete Design of the cleaning systems duly vetted by IIT/NIT for the approval of Accepting officer before execution at site. complete bill of material,specification and necessary certificates if any shall be submitted by the bidder duly signed in duplicated before execution of the work. The design should comply with the following minimum requirements : - (a) Supply & Fixing of Spraying Nozzle with following specifications: -Material : ABS (plastic) - Working Angle - 0 to 90 deg - Discharge: 5 to 7 LPM - Pressure: 1 KG/Sq.cm to 2 KG/Sq.cm Qty :- As per Design (b) Supply & Fixing of Automatic Valve with following specifications; - Working Medium: Water - Motion Pattern: Diaphragm Type - Electromagnetic Actuator, - Working pressure 0 to 10 Bar - Working medium Temperature: 0 to 85 deg C - Material of Body: NV 66/ CF 8/ CF 8M Qty :- As per Design (c) Supply & Fixing of screen filter with following specifications; - Maximum Working Pressure : 10 KG/sq.com - Range of water flow: 5 - 8 cum / Hour - Screen Cartridge: Double Screen 30/120 Mesh -Filtration surface Area: 12p Sq.cm Qty :- Qty of spraying nozzle shall be such that spray nozzle should clean the complete solar module.
item No. 36 Contd/-.. (d) Supply & Fixing of Auto controller with following specifications; - Single Phase SMPS - 3A/12Vdc Output - Control Card -Qty : Based On Design (e) Supply & Fixing of Submersible Pump with following specifications; - Stator : SS 304 - HP/KW : Based on Design - Phase : Single/Three - RPM : 2900 - Current 7.5 Amp -Qty : Based On Design Note : All the above are minimum essential requirements. Contractor has to submit detailed design along with layout and details of all components and bifurcation details of rates for each component considered in the quoted rates as per design. The quoted rates are deemed to be included with rates of all the components as per design where not mentioned here in before. Nothing extra will be payable on this account.
UPVC pipes (SCH 80) HSN Code : 3917 of pressure rating 10 kgf/cm2 ,class 'A' laid in trenches of the following sizes,
(a) 110 mm dia
(b) 75 mm dia
(c ) 50mm dia
(d) 40 mm dia
(e) 32 mm dia
Supply & fix UPVC Ball Valve,100 mm Dia
Supply & fix UPVC Ball Valve,75 mm Dia
Supply and fix PPR Gate Valves (Brass Insert) of 50 mm bore.
Supply and fix PPR Gate Valves (Brass Insert) of 40 mm bore.
Supply and fix PPR Gate Valves (Brass Insert) of 32 mm bore.
Supply and Fixing of Wet Type Submersible Pressure pump capacity of 5 HP(1W+ 1SB) With Suitable panel board as per IS 8034/1989 and IS 9283/1995 suitable to pump with dry run preventor etc. Complete as per ISI standard specification.
S&F of 80 mm NRV for Water Pipe line Type - Swing type flange end Bolted cover MOC - CI complete all as specified and directed.
S&F of pressure gauge 4" dial - SS Glycerine; Type - Diaphragm; complete all as specified and directed.
Supply, laying and testing XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Construction of Valve Chamber of following internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified. (a) 900X 900 X 900mm type 'C'
(b) 600 X 600 X 600 mm type 'B'
External Electric Supply
S&F 6 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
Material and labour Cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 80 Watts LED Flood Light with fittings on the Roof of solar Module installed floors complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core PVC Insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through including non metallic rigid PVC conduit with all conduit accessories not less than 20mm dia (concealed) and including provision of 1.5 sqmm PVC insulate unsheathed cable FRLS as earth continuity conductor, metal flush box and white cover plate with frame for suitable number of modules flush box concealed in walls with suitable screws for housing the switches, socket outlets, fan regulators etc, complete all as specified and as directed.
Switch piano, one way, 6 Amps, for one module complete all as specified and as directed.
Supply and lay GI pipe 80 mm bore Medium grade for cable protection complete all as specified and as directed.
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Security fencing with wicket gate
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in hard/dense soil, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggreggate as in foundation filling and mass concrete complete all as specified and directed.
S & F Mild Steel con-forming to Fe-290 Gde E-165 quality A as in angle post or struts in fencing fixed independently including cutting and bending to shape as directed, drilling holes, notching for wire, flat iron fillet for securing wire mesh etc complete all as specified and directed.
M&L mild steel structural Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square exc 5 cm not exceeding 10cm long and 5 to 10 mm dia complete all as specified and directed.
Supply only Chain link MS galvanised fencing wire made with 3mm dia GI wire & 100x100mm mesh size all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts,etc. including provision of binding wire complete all as specified and directed.
Mild steel round bars 10 mm dia and over as in strengthening bars for chainlink fencing conforming to Fe-290 Gde E-165complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description exc 10 cm girth or width complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description not exc 10 cm girth or width complete all as specified and directed.
Foot path
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soi complete all as specified and directed.
M&L for Hard core of gauge not exc 63 mm size depositing spreading , leveling watering and well ramming with broken stone boulders / stone specified complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in floors surface finished cement surface all as specified and directed.
M&L Sand filling under floor or in foundation including watering and consolidation and all as specified and directed.
M &L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement & Pigment all as specified and directed.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in kerbs, coping etc including necessary formwork complete all as specified and directed.
Removing excavated soil in hard/dense soil exc 1.50 Km and not exc 5.00 Km out side the campus including loading and unloading etc., where responsibility regarding place of deposition and permission from all authorities etc., in this regard will be of contractor and complete all as specified and directed.
Mild steel Ladder
Mild Steel base plates & cleats (Chequered or plain) channels, squared cut or notched (Ordinary and counter sunk) forming holes for nuts and bolt or welded attachment including Anchor Nuts & bolts 20mm dia 400mm long (machine made) with hexagonal or square heads conforming to Fe-410- W(Gde E-250) quality- 'A' complete all as specified and as directed.
M&L Plain cement concrete, type B2, 1:2:4 in foundation filling and mass concrete complete all as specified and directed.
M & L for two coats of Black bituminous paint of any description wood,steel, iron, concrete,brick, stone, etc.,exceeding 10cm in width or girth including preparation of new steel surfaces complete all as specified and directed.
UG sump of capacity 20000 litres
M & L for provn of RCC UG sump of capacity 20000 litres using M-30 mix design including excavation in all types of strata, timbering, shoring and strutting including bailing/pumbing out of water where required, foundation concrete, RCC bottom slab, side wall, top slab with man hole covers including water proofing plaster inside and refilling of earth and disposal of surplus soil, including all piping connections valves,MS rungs, plinth protection 750 mm allround,Internal plaster and external plaster, painting of exposed surfaces etc complete all as specifiedin as per CWF (AF) TVM TD drawings and as directed. Note : (i)The UG Sump shall be constructed all as per Drg No. TD/106/2021 Sht No. 1/6 to 6/6 (ii) All the testing of UG sump against leakage / seepage has to be carried out after competion of the work and neccessary test result shall be submitted to GE by the contractor (iii) Quoted rates shall deemend to be included for all the above provisions.
Total of Schedule 'A'
rvelectricals
Phoenix Infra
Sant Construction Co.
Spectrum Consultants
N RAJEGOWDA and CO
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .