| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹45.9 L+₹4.5 L (10.8%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.7 L+₹5.2 L (12.6%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹47.8 L+₹6.4 L (15.5%)Rejected-Finance 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹49.0 L+₹7.5 L (18.2%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIRS TO STEEL GATES, ROLLING SHUTTERS, PARKING SHEDS, CGI SHEET, AC SHEET ROOFS, STRUCTURAL STEEL WORKS, SKY LIGHTS, VALLEY GUTTERS ETC TO VARIOUS BUILDINGS INSIDE FORT WILLIAM AND REPAIR/MAINT TO FIRE HAZARD AFFECTED AREA/ROOM IN THE BASEMENT OF
2021_MES_491592_2
8805/E8
Open Tender
Civil Works
Item Rate
210 days
GE (FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE (FW) Kolkata
₹74,000
10 Feb 2022
3 Dec 2021
24 Dec 2021
3 Dec 2021
23 Dec 2021
17 Dec 2021
60 days
Amount
SCHEDULE 'A PART-II (BLDG WORKS) Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
Dismantling fencing wire mesh any type complete all as specified and directed.
Dismantling of post struts (wood, steel or RCC) any section incl Taking out embedded portion in concrete and making good disturbed ground complete all as specified and directed.
-ditto- but embedded in natural ground
M&L for providing precast cement concrete in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat ing etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/SQM on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but using old serviceable sheets obtained from dismantling of sheets
All as per Item No. 14 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing etc complete all as specified and directed.
S&F galvanized, plain mild steel sheeting 0.63 mm thick, with minimum zinc coating of 120 gram/Sq m, as in ridge, hips, valley gutters, drip and straight flashing, complete all as specified and directed.
S&F in repair fibre glass reinforcement translucent corrugated sheeting of 2mm thick with two corrugation side lap fixed with fixed with L type or J type or cranked hook bolts in roofs, walls etc complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
S&F in repairs 35mm thick precast cement concreate (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) louvers and jallies including all moulding, set in cement mortar 1:4 fixed complete all as specified and directed.
M&L for brick work using fly-ash bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L in brick work using fly-ash bricks straight or curved on plan to any radius in half brick wall, built in cement mortar 1:4 all as specified and directed
M&L for use and waste for form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for rough finished surfaces of concrete flat complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L for formwork to side of pillars, posts, struts, piers, columns for fair finished surfaces complete all as specified and directed.
M&L for RCC type A1 1:1½: 3 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers , lintels over 1.5 mtr span complete all as specified and as directed.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded aggregate)as in slabs supported on walls, beams and columns in floors, roofs, drain, ducts, canopies etc. complete complete all as specified and as directed.
M & L for RCC 1:1½:3 (nominal mix) using 20 mm dia graded stone aggregates as in columns, pillars, posts etc complete all as specified and directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed .
M&L granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
-ditto- but as in vertical surfaces over and including 10 mm thick screed bed in cement mortar 1:3
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender)
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/Paving etc, finished even and smooth using extra cement complete all as specified and directed.
M&L for forming construction/dummy joints 65 mm deep x 10 mm wide filled with sealing compound Grade 'A' complete all as specified and directed.
M&L for providing 100 mm thick, Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in footpath, sub base of floor completed all as specified and directed.
M&L 10mm thick cement plaster on ceiling surfaces finishing even and smooth without using extra cement in cement mortar 1:4 including necessary scaffolding complete all as specified and directed.
M&L 5 mm thick cement plaster on ceiling surfaces finishing even and smooth without using extra cement in cement mortar 1:3 including necessary scaffolding complete all as specified and directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
Supply only liquid water proofing compound
M&L 15mm thick cement plaster on brick or concrete walls in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for 2 coats of acrylic distemper over a coat of alkali resistant primer over 2 mm thick wall putty on new internal plastered wall surfaces after preparation of surfaces complete all as specified and as directed.
Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L preparing newly plastered ceiling surface and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L applying two coat of cement base paint over a coat of alkali resistant primer on newly plastered surfaces of walls including preparation of surfaces.
M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed.
M&L applying one coat of cement base paint on walls, cornices incl preparation of old plastered or unplastered surfaces of wall complete all as specified and directed.
Material and labour for applying one coat of exterior acrylic emulsion weather proof paint to old decorated surfaces of walls of any description, over 10cm width or girth not otherwise described, including preparation of surfaces complete all as specified and as directed.
M&L for applying two coats of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) including preparation of newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described complete all as specified and directed.
S&F in repair mild steel Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
S&F in repairs steel rolling shutters not exc 8.0 sqm of laths thickness 1.00 mm, with out ball bearing, as specified including top cover , anchoring rod, hasp and staple erected in position as indicated complete and two coats of synthetic enamel paint over a coat of primer incl taking down existing shutter complete all as specified and directed.
S&F in repairs steel rolling shutters exc 8.0 sqm but not exc 12.00 sqm, of laths thickness 1.25 mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple erected in position as indicated complete and two coats of synthetic enamel paint over a coat of primer incl taking down existing shutter complete all as specified and directed.
Taking down existing rolling shutter of area not exc 8.00 sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding as required and refixing in position etc complete all as specified and directed by Engr-in-Charge (Note : Spare parts required will be measured and pad separately under respective items)
Taking down existing rolling shutter of area exc 8.00 sqm but not exc 12sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding as required and refixing in position etc complete all as specified and directed by Engr-in-Charge (NOTE: Spare parts required will be measured and paid separately under respective items)
M&L servicing, overhauling, greasing, easing of existing rolling shutters of any area complete all as specified and directed.
S&F in repair safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
Supply only ball bearing for rolling shutters complete all as specified and directed.
Supply only guide channel complete all as specified and directed.
Supply only locking system for rolling shutter complete all as specified and directed.
M&L for running welding in repairs , not exceeding 2.5 cm length, thickness of metal to be welded not exceeding 6mm thick, complete all as specified and directed.
M&L for running welding in repairs , exceeding 2.5 cm but not exceeding 5 cm length, thickness of metal to be welded not exceeding 6mm thick, complete all as specified and directed.
Excavation in post holes each not exc 0.5 cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft /loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
S&F mild steel fencing posts and struts including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets including all necessary drilling bolting or riveting etc and similar work confirming to fe -290 gde E-165 complete all as specified and directed.
Re-fixing of old serviceable mild steel fencing posts and struts including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets including all necessary drilling bolting or riveting etc and similar work complete all as specified and directed.
S&F 3mm dia PVC Coated galvanised mild steel chain link fencing of mesh size 100mm x 100mm fixed with string bolts including provn of binding wire etc complete all as specified and directed.
Re-fixing of old serviceable mild steel chain link fencing, any size or thickness, fixed with string bolts including provn of binding wire etc complete all as specified and directed.
S&F MS round bar for holding chain link fencing nibs etc with fencing posts complete all as specified and directed.
S&F MS Screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to the fitted with washers &one hexagonal or square nut exe 5cm n exc 10cm long &11 to 15mm in dia complete all as specified and directed.
S&F in repairs galvanized 2 strand steel barbed wire fencing conforming to IS : 278, with 2.24 mm dia. barb wire conforming to IS : 280 with zinc coating as per IS : 4826, barbed with 2 mm dia. barbs at 75 mm spacing and straining and fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc., incl dismantling of existing barbed wires complete all as specified and directed. (Note: - Each line of wire will be measured)
Re-straining, resecuring incl making good barbed wire, any type and re-fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed. (Note: - Each line of wire will be measured)
M&L rolled mild steel in joist, channel, angle, or tee section fixed independently, without connecting plates, etc (cut to ordinary length i.e.. within 20mm of the length indicated) of FE-410- W(Gde-E-250) quality-B complete all as specified and directed.
M&L rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe 410-W (Gde-E- 250) quality-B (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L Mild steel framed work such as grills of ornamental type, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works incl portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc confirming to grade Fe-290. Gde-E-165 complete all as specified and directed.
M&L for applying one coat of white wash to old decorated surfaces of wall including preparation of surfaces complete all as specified and as directed.
M&L for applying one coat of white wash to old decorated surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
Suppy & laying in repairs Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed. (NOTE: Sand cushioning shall be measured and paid seperately)
M&L Sand filling under floors under paver block, thickness not exc 40 mm including consolidation complete all as specified and as directed
S&F in repair cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 150 mm bore, fixed with cement joints complete all as specified and directed.
S & F in repair 150 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S & F in repair 150 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
S&F in repair cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 100 mm bore, fixed with cement joints complete all as specified and directed.
S & F in repair 100 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S & F in repair 100 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required and similar small articles conforming to Fe-290 Gde-E-165 including painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair 110mm OD PVC (SWR) pipes, single socketed, conforming to IS:13592-1992, type 'A', in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius for 110 mm OD PVC pipes complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal for 110 mm OD PVC pipes complete all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface and reinforcement bars, lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed. (NOTE: Measurement shall be considered for the surface area of RCC member)
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Reinforcement bars shall be paid seperately)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litreand adhjesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for grouting of voids/cracks with high strenth epoxy resin grout as per manufacturers instructions complete all as specified and directed. (Make- Conbexta EP 10 of FOSROC or equivalent product in other makes specified in tender) (NOTE: The item shall be executed if any voids/cracks are found during execution/removing of concrete mortar from the surface).
M&L for applying two coats of elastomeric and protective anticarbonation coating, on concrete/masonry surfacs over a coat of silane-siloxane primer as per manufacturer's instructions complete all as specified and directed. (Make- Dekguard E2000 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
GENERAL NOTES FOR ITEM NO. 95 TO 102 :- (i) The work shall be got executed through authorised applicator of the chemical manufacturers. Necessary documents to this effect shall be obtained from manufacturer and submitted to the Engineer-in-Charge. (ii) Contractor shall provide additional manpower, resources, preparatory work etc. required for execution of the work as required by the authorised applicator. Quoted rates are deemed to be inclusive of the above aspects. No extra claim shall be admissible during execution of work on this account.
Dismantling of ceiling board alongwith snap grid frame of any thickness including cover fillets complete all as specified and directed.
M&L for snap grid system with powder coated aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and powder coated aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with supporting hangar 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
Re-fixing of aluminium snap grid sytem using serviceable grid sections and ceiling board obtained from taking down of false ceiling including hanging arrangements with supporting hangar 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
S&F non asbestos fibre cement building board, 4mm thick, fixed to aluminium frame work with screw as in ceiling duly finished with two coats of oil bound distemper over a coat primer complete all as specified.
Re-fixing of serviceable ceiling board/tiles (obtained from Item 104 above), any thickness, fixed to aluminium frame work with screw as in ceiling duly finished with two coats of oil bound distemper complete all as specified.
M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 2 mm thick wall care putty complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling and applying one coat of acrylic distemper on ceiling, cornices etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling and applying two coats of acrylic distemper on ceiling, cornices etc complete all as specified and directed.
M & L Vitrified coloured (light shade) Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
-ditto- but as in skirting over 10 mm thick screed in cement mortar 1:3 complete
Taking down PVC shutter, of any description, exceeding 1.0 sqm and not exceeding 2.0 sqm each and removing from the site complete all as specified and directed.
S&F factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) complete all as specified and directed.
S&F 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300 mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Supply and fixing in repairs 150mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F welded steel wire fabric n. exc 4 Kg/sqm, fixed to steel members complete all as specified and directed.
SCHEDULE 'A PART-II (INT ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 122 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 122 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 122 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
MODULAR FAN REGULATOR
S & F Modular Fan step regulator, 120 watt, 2 module
MODULAR BELL PUSH
S & F Modular Bell push 6A, 1 module
MODULAR BLANKING PLATE
S & F Modular Blank plate, 1 module
MODULAR TYPE COVER PLATE WITH FRAME
S&F Modular White cover plate with frame 3 module
S&F Modular White cover plate with frame 6 module
MODULAR TYPE METAL FLUSH BOX
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 6 module
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
Supply and Fix in repairs recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND)
SCHEDULE 'A' PART-III (AIR CONDITIONING) Taking down/dismantling of existing air ducting, of any size with insulation, diffusers etc from any position by unscrewing nuts, bolts and washers etc, of any size and removal from site complete all as specified and directed.
Supply, fabrication, installation and testing of factory/site made rectangular ducts as per IS specifactions, made out of galvanised steel sheet of 20 gauge (1 mm thick), with Class VIII galvanisation conforming to IS 277 complete with mild steel frame structure and necessary supports using thread rods and anchor bolts, supplying air collars, vanes complete with splitter, damper, duct damper etc, for supply and return air, with maximum acceptable noise level in conditioned space of 40 dB at 3 m distance from diffusers as per IS 1950-1962 complete all as specified and directed. (NOTE: The duct fabrication and installation shall confirm to IS 655-2006. All dampers, splitters shall be fabricated out of galvanised steel sheet of two gauges higher than the duct piece. All items related to fabrication ducts shall conform to the relevant IS mentioned in IS 655-2006).
Supply and fix in repair powder coated extruded aluminium diffusers with VCD complete all as specified and directed.
Supply and fixing thermal insulation on the sheet metal duct with aluminium foil laminated closed cell nitrile rubber Class "0" insulation complete all as specified and directed.
S&F in repair DVRF connected DSA handset, fully wired, properly fixed on walls duly clamped complete all as specified and directed.
M&L for vacuuming complete system of VRF air conditioning plant (1 x 21 TR and 1 x 18 TR) with double stage vacuum pump of (-) 2 Kg/cm² vacuum pressure after repairs to compressor or repair in refrigeration system, charging the dry nitrogen gas and hold up to 24 hours and rectifying the leakage, if any by repairing of copper pipes, service valves/oil seal including top up of compressor oil and charging R-410A gas complete all as specified and directed. (NOTE: Refrigerant gas R-410A, Nitrogen gas will be measured and paid seperately under relevant items. Once charged, the R-410A gas should hold in the system for a minimum of six months. In case of leakage, before six months, the contractor shall re-charge the gas under his own arrangement).
Supply only nitrogen gas for leak testing of VRF AC plant system complete all as specified and directed.
Supply only refrigerant gas R-410A complete all as specified and directed.
dutta and dutta
MAZUMDER ENTERPRISE
ARJUN DAS VALECHA
GHOSH ENTERPRISE
SHEIKH ENTERPRISE
Somani Builders
MS HORIZEN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .