Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
23 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mrs. Charanya Ambati
Power Grid Corporation of India Limited -Saudamini, 3rd Floor, Plot No 2, Sector-29 Gurugram (Haryana) - 122001
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with Transmission system for evacuation of power from Luhri Stage-I HEP through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
Open
Power/Energy Projects/Products
Works
Nange
₹25,000
23 Jan 2023
30 Aug 2022
25 Jan 2023
30 Aug 2022
23 Jan 2023
30 Aug 2022
13 Sept 2022
Name of Package Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Package No : SS01
Specification No. : TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
Completion Period 24 Months
General guidelines for filling up the Attachments : Substation Package -SS01 :
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Specification No.: TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 3 Bidder’s Eligibility: A separate sheet is enclosed in volume-III.
6 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
7 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
8 Attachment 19: Declaration
9 Format for Attachment 20 to 23 and 25 to 29 are attached herewith.
10 Format for Attachment 24 is available in Section-VI, Vol.-I of the Bidding Documents.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Name of Sole Bidder
Address of Sole Bidder
Address of other Partner
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any)
Any Tower Parts Manufacturer proposed other than the bidder [Yes / No] No
Proposed Tower Parts Manufacturer other than the bidder, if any [Maximum two nos.]
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-3(JV) SS01 Sole Bidder SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services &
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 24
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-3(QR) SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Attachment-QR of this volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-4 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-4(A) SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-4(B) SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-5 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additional to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-5(A) SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
S.No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract. .
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-6 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Annexure I toAttachment-6 SS01
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-7 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Details of Alternative Bid)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-9 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 ATTACHMENT-10SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. In particular, we declare that the (i)41.67MVAR, 420kV, 1-phase Reactor (ii)50 MVAR,420kV,3-phase Shunt Reactor , offered under this package shall meet the maximum loss requirement as stipulated in Technical Specifications. We further declare that in the event of any deficiencies in meeting the guarantees in respect of the characteristics mentioned below as established after conducting the factory test, you may at your discretion, reject or accept the equipment after assessing the liquidated damages as specified in the relevant clauses of Bid document. We note that in case we take any deviation regarding the maximum losses, as mentioned above, anywhere in the bid including Attachment-6 (Alternative, Deviations and Exceptions to Provisions), our bid shall be considered non –responsive in line with ITB clause 24.1(b) as modified in Section BDS. Further, We confirm that the equipment offered shall have minimum (or a maximum, as the case may be) performance specified in the Technical Specification. We further guarantee the performance/effiency of the equipments in response to the Technical Specification.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-10 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-11 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-12 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
WE HAVE QUOTED OUR BID PRICE ON FIRM PRICE BASIS.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-13 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-14 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. Package and Specification Number TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
during his participation in the tender process and during the contract execution :
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) TThe IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter..
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Integrity Pact Page 8 of 8
Specification No.: TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-15 SS02
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29 YES
Gurgaon (Haryana) - 122001 NO
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion: (Initial Advance)
Supply Portion: (Engineering Advance)
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3.(a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3.(b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement poliy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidenec is to be attached. Please refer remarks at the end of the attachment. NO
3.(c) If 3.(b) is 'Yes' please mention whether you are (Proprietary MSE/Partnership MSE/Private Limited Company) owned by SC/ST entrepreneurs.
3.(d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. NO
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
(i) Madhya Pradesh
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Contact Details
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
* The definition of MSEs owned by SC/ST is as given under:
(a) In case of Proprietary MSE, Proprietor(s) shall be SC/ST.
(b) In case of partnership MSE, then SC/ST partners shall be holding at least 51% shares in the unit.
(c) In case of Private Limited companies, at least 51% shares shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-16 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Additional Information)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
2.0 Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years:
Year Name of client Details of Transgression of Integrity Pact by the bidder
5.0 OTHER INFORMATION
5.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Additional Information)
Name(s) and Addresse(s) of other partner(s)
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
The Bidder shall furnish
1.1 A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
(i) The Bidder should accordingly also provide the following information/documents
Details of Banker:
Address of Banker
Contact Name and Title
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.1 OTHER INFORMATION
Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Additional Information)
Name(s) and Addresse(s) of other partner(s)
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference): Reference ITB clause 9.3(p)(ii)
The Bidder shall furnish
1.1 A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3 (p)(i)]
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
(i) The Bidder should accordingly also provide the following information/documents
Details of Banker:
Name of Banker `
Address of Banker
Contact Name and Title
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid.
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.1 OTHER INFORMATION
Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-17 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-17 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-17 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-18 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Attachment-19 SS01
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Date Month Year Pay Order 19 nineteen 19 th
(a) Attachment 1(SS01) : NOT APPLICABLE Bank Guarantee Banks certified Cheque 20 twenty 20 th
(b) Attachment 2(SS01) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee 21 st
(c) Attachment 3(SS01) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). Sole Bidder 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). 0 1 Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. Not Applicable 24 th
(d) Attachment 4(SS01) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(SS01) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A(SS01) : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
(g) Attachment 6(SS01) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(SS01) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8(SS01) : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9(SS01) : Work Completion Schedule. 30 th
(k) Attachment 10(SS01) : Guarantee Declaration. 31 st
(l) Attachment 11(SS01) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(SS01) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(SS01) : Declaration regarding Social Accountability.
(o) Attachment 14(SS01) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(SS01) : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(SS01) : Additional Information.
(r) Attachment 17(SS01) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(SS01) : Safety Pact
(t) Attachment 19(SS01) : Declaration
(u) Attachment 20(SS01) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(SS01) : Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products
(w) Attachment 22(SS01) : Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(x) Attachment 23(SS01) : Affidavit.
(y) Attachment 24(SS01) : Confirmation regarding furnishing Declaration regarding Non-Participation as a Bidding Company or as a member of any Bidding Consortium in Transmission Project under Tariff Based Competitive Bidding Route
(z) Attachment 25(SS01) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(aa) Attachment 26(SS01) : Certification by the Bidder as per DoE Order in line with ITB Clause 2.1(In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture)
(bb) Attachment 27(SS01) : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(cc) Attachment 28(SS01) : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(dd) Attachment 29(SS01) : CONFIRMATION IN REGARD TO DESIGN & TYPE TEST(To be furnished in case bidder is proposing to qualify through Note-4 under Route -1 of QR)
(ee) Attachment 30(SS01) : Bid Securing Declaration to be submitted by the Bidder.
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
3.0 A * (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with................, a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012, Notification dated 01/06/2020 and 26/06/2020 including subsequent amendments, read in conjunction with related notifications issued from time to time for such enterprises. (Delete if not applicable)
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We have noted the provisions of the Bidding Documents that POWERGRID intends to participate in the selection of Transmission Service Provider (TSP) for the "Transmission system for evacuation of power from Luhri Stage-I HEP’’. For this purpose, the bids have been invited by POWERGRID for the subject Package covering certain scope of work under the aforesaid TBCB Project. The qualified, lowest evaluated Bidder having requisite capacity and capability to perform the contract for the aforesaid Package(s) as per the provisions of the Bidding Documents shall be pre-selected, for the scope of work contained in the Bidding Documents, for associating with POWERGRID for the purpose of tariff bidding by POWERGRID in the RfP process of the BPC for the subject Project under TBCB route and, in case POWERGRID becomes successful Bidder, the successful Bidder for aforesaid mentioned Package(s) will be awarded the Contract for execution of scope of work contained in the Bidding Documents. An MOU shall be signed with the pre-selected Bidder prior to tariff bid submission by POWERGRID to BPC against its RfP process. This MOU shall, inter-alia, bind both POWERGRID and the pre-selected Bidder for associating on exclusive basis and maintaining strict confidentiality by the pre-selected Bidder of the prices, terms and conditions.
7.1 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the deadline of bid submission as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
Other Partner -1 Other Partner -2
Printed Name : Printed Name :
Designation : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Attachment-3 (QR)
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
SPECIFICATION No. : TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
(Qualifying Requirement Data)
Bidders’s Name & Address: Contract Services
Name: Power Grid Corporation of India Ltd.,
Address: "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Bidder/Lead Partner In case of Joint Venture
For Other Partner(s) For Other Partner(s)
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
TECHNICAL EXPERIENCE
1.1 Route-1: 1.1 The Bidder must have designed, manufactured, type tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least two (2) nos. Gas Insulated Switchgear (GIS) circuit breaker bays@ of 345kVor above voltage class in one (1) Substation or Switchyard during the last seven (7) years and these bays must be in satisfactory operation# for at least two (2) years as on the originally scheduled date of bid opening i.e. 03/10/2022.
2.1.1 In case the Bidder is a Foreign Entity, following requirements shall be complied:
i (i) If the bidder is submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, the bidder must, in its bid, propose an Indian Associate for executing the On-Shore Supply and On-Shore Services Contract, as per the provisions of bidding documents. The proposed Indian Associate must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays of 345kV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above For executing on-shore supply contract, the bidder in its bid, may alternatively propose its Indian Subsidiary or Group or Joint Venture Company as Indian Associate provided that the proposed Indian Associate has been registered in India (as per Companies Act 1956 or 2013 of India) for establishing manufacturing and testing facilities for 765kV GIS or above voltage level as on the date of bid opening mentioned above.
ii A) The Subsidiary or Group Company or a Joint Venture Company (JVC) of the bidder shall have manufacturing & testing facilities for 765kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned above. OR The bidder must have incorporated a Subsidiary or Group Company or a Joint Venture Company (JVC) as per Companies Act 1956 or 2013 of India, to manufacture 765kV or above voltage level GIS in India and it must have commenced the construction activities for establishment of 765kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening mentioned above. B) The bidder must supply at least one (1) no. 765kV GIS Circuit breaker bay* manufactured in the said facilities in India, for which Bidder shall furnish an undertaking (as per enclosed format in Volume-III of Bidding Document) along with the bid. C) Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from Indian works of its Subsidiary or Group Company or a Joint Venture Company (JVC) provided the Subsidiary/JVC/Group Company must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay should have been either supplied or type tested (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above.
1.2 Route-2: 1.2 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the collaborator(s), provided that the collaborator(s) meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 3 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.3 Route-3: 1.3 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the parent/principal, provided that the parent/principal meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 3 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.4 Route-4 1.4 In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 345kV or above voltage class in one (01) new GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# for at least two (02) years as on the originally scheduled date of bid opening mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. iii. A legally enforceable undertaking (jointly with the GIS Manufacturer(as per enclosed format in Section-VI, Vol-I of bidding document) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s) is submitted along with the bid stating that GIS Manufacturer shall furnish performance guarantee for an amount of two (2) % of the total contract price. This performance guarantee shall be in addition to the Contract Performance security to be submitted by the Bidder
Note :- 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. (@) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. In case bidder is a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company). 4. In case bidder is qualifying through Route-1, type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents.
Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder or of each Partner of a Joint Venture.
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder/ Lead Partner/ Partners of JV in case of Joint Venture/Indian GIS Mnaufacturer in support of meeting the requirement of para 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : #REF!
Single Firm/Lead Partner/Other Partners of a JV/Indian GIS Mnaufacturer #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 345kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
NOTE: type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents (Attachment-29 in Volume-III)
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 765kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Foreign Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from India provided his Subsidiary or Group Company or a Joint Venture Company (JVC) must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay either should have been supplied or should have been type tested ( as per IEC or equivalent standard) as on the originally scheduled date of bid opening as mentioned above
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
Format for the Indian Associate executing the On-Shore Supply and On-Shore Services Contract for a Foreign Entity submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, in support of meeting the requirement of para 1.1.1(i) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Associate executing the On-Shore Supply and On-Shore Services Contract
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 No. of GIS/AIS Circuit Breaker equipped bays under the contract
(Indicate nos. of Circuit Breaker equipped bays of 345 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
No. of years, the above CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (Route-2) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Bidder not meeting the requirement stipultaed in Clause 1.1 of Annexure-A (BDS), but has established manufacturing and testing facilities in India for 345kV or above Gas Insulated Switchgear (GIS):
1 Whether 345kV or above voltage level GIS Circuit Breaker bay manufactured by bidder have been supplied or Type tested
A if Type tested, details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 345kV or above voltage level GIS bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom 345kV or above voltage level GIS bays were supplied by the Bidder
iv No. of 345kV or above GIS Circuit Breaker bays under the contract
Name of the substation or switchyard
Whether 345kV or above voltage level GIS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Collaborator under the Contract.
If Yes, indicate the Name of Collaborator(s)
No. of years, the above GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 345kV or above GIS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2(Route-2) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 345kV or above GIS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) No. of 345kV or above GIS Circuit Breaker bays under the above contract
(Indicate nos. of GIS Circuit Breaker bays of 345kV or above where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above GIS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 345kV or above GIS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.2 of Annexure-A (BDS)
Whether confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 3% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.2 of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above GIS equipment in India has been enclosed with bid (in line with para 1.2 of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3 (Route-3) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian established as Subsidiary/JVC/Group company by its parent/principal
Whether bidder have established manufacturing and testing facilities in India for 345kV or above voltage level GIS
1 Whether 345kV or above voltage level GIS Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Priincipal Company
A if Type tested, details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 345kV or above voltage level GIS bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom 345kV or above voltage level GIS bays were supplied by the Bidder
iv No. of 345kV or above GIS Circuit Breaker bays under the above contract
Name of the substation or switchyard
Whether 345kV or above voltage level GIS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/ Principal Company under the Contract.
If Yes, indicate the Name of Parent/ Principal Company(s)
No. of years, the above AIS/GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 345 GIS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3(Route-3) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Parent Company/ Principal (refer para 1.3), if applicable: 0 #REF!
Name of the 345kV or above voltage level GIS Equipment Manufacturer (refer para 1.3), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) No. of 345kV or above GIS Circuit Breaker bays under the above contract
(Indicate nos. of GIS Circuit Breaker bays of 345kV or above where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above GIS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 345kV GIS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.3 of Annexure-A (BDS)
Whether confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 3% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.3 of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV GIS equipment in India has been enclosed with bid ? (in line with para 1.3 of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.4(Route-4) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 345kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Whether Undertaking (Jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 2.0 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive
b) Minimum Average Annual Turnover^(MAAT) of the bidder for best three years i.e. 36 months out of last five financial years of the bidder should be Rs. 1110 million.
^Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other operative income / other income”.
For Bidders to qualify for more than one package, their financial position shall not be less than the sum of the requirement for the packages they propose to qualify for ( strike through if only one package)
c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than Rs. 185million.
Note: i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) as on the originally scheduled date of bid opening as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he completes five (5) years from the date of commercial production of such equipment (s) in India as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered. iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 2.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2.0 (b) & 2.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
2.1 Financial Qualification Data: 2 or more
Name of the Bidder
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2021-22 No
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2021-22
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2021-22
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2021-22
C Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2021-22
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2021-22
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
3.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 1.0 and 2.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 2.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position criteria given at para 2.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position criteria given at para 2.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 2.0 (b) & (c) above.
b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner(s) must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays@ of 345kVor above voltage level in one (1) substation or switchyard during the last seven (7) years in India and these bays@ must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above. Note:
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
Note: (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
4 4.0 The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
For Name of Other Partner-1 of JV For Name of Other Partner-2 of JV
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
1st Year Yes Yes
2nd Year Yes Yes
3rd Year Yes Yes
4th Year Yes Yes
5th Year Yes Yes
Date : Printed Name :
Place : Designation :
Package Name : Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Specification No. TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
Spec.No. TBCB/Lahuri/Nange /400kV/GIS/SS01/G5
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-4, Sch-5, Sch-7, Discount (Optional), Guarantee Declariation and Bid Form 2nd Envelope.
2 All the cells in Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically in Sch-1, after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of GST applicable on Supply of Goods and Services) :
● Amount of GST shall be calculated autometically
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Spec.No. TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Spec.No. TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule 1
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contracts Services, 3rd Floor
Power Grid Corporation of India Ltd.,
Name : "Saudamini", Plot No.-2
Address : Sector-29,
Gurgaon (Haryana) - 122001
PLANT AND EQUIPMENT (INCLUDING MANDATORY SPARES PARTS) TO BE SUPPLIED
SI. No. PR No. PR Item No. Activity Description Material Code HSN Code Whether HSN in column ‘ 6 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Quantity Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST
I 400/200kV Nange GIS
1 400kV Bus Reactor 1000057268 85042330 18 41.67MVAR, 420kV, 1-phase Reactor excluding Insulating Oil EA 4 Included 0.00 0 0
2 400kV Bus Reactor 1000057272 85049010 18 Insulating Oil for 41.67MVAR, 420kV 1-phase Reactor SET 4 Included 0.00 0 0
3 LT transformer 1000004951 85042100 18 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0
4 AIS equipment 1000004535 85359090 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0.00 0 0
5 AIS equipment 1000020419 85354010 18 336kV Surge Arrester (1-phase) EA 17 Included 0.00 0 0
6 AIS equipment 1000004401 85462040 18 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 32 Included 0.00 0 0
7 AIS equipment 1000020417 85354010 18 216kV Surge Arrester (1-phase) EA 7 Included 0.00 0 0
8 AIS equipment 1000001695 85462040 18 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 27 Included 0.00 0 0
9 AIS equipment 1000001998 85049010 18 Current transformer (33kV) for transformer Netural along with supportstructure & terminal connector SET 2 Included 0.00 0 0
10 GIS Equipment 1000032699 85389000 18 3150A, 63KA, 1SEC SINGLE PHASE 420KV SF6 TO AIR BUSHING EA 17 Included 0.00 0 0
11 GIS Equipment 1000004287 85389000 18 420kV, 3000A, 63kA, Single phase, SF6Gas Insulated Bus Duct (GIB) outsideGIS Hall alongwith associated supportstructure M 500 Included 0.00 0 0
12 GIS Equipment 1000004533 85359030 18 420kV, 4000 A, 63 kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included 0.00 0 0
13 GIS Equipment 1000004634 85359030 18 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(with PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0
14 GIS Equipment 1000004638 85359030 18 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(without PIR) as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
15 GIS Equipment 1000004505 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
16 GIS Equipment 1000004635 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0
17 GIS Equipment 1000004637 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 2 Included 0.00 0 0
18 GIS Equipment 1000004632 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS BusReactor bay module as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
19 GIS Equipment 1000009711 85389000 18 Controlled switching device for 420 kV, 3 phase circuit breaker SET 2 Included 0.00 0 0
20 GIS Equipment 1000001690 85359030 18 245kV, 1600 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 2 Included 0.00 0 0
21 GIS Equipment 1000001832 85359030 18 245kV, 2500 A, 50 kA, SF6 GIS Buscoupler bay module as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
22 GIS Equipment 1000001853 85359030 18 245 kV, 4000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included 0.00 0 0
23 GIS Equipment 1000001693 85389000 18 245kV,1600A, 50kA,3 Single phase/3Phase, SF6 Gas Insulated Bus Duct (GIB)outside GIS Hall alongwith associatedsupport structure(Quantity mentionedhere is for 3 Phase type) M 250 Included 0.00 0 0
24 GIS Equipment 1000029503 85389000 18 245kV, 1600A, 50kA Single phase SF6 to Air Bushing EA 7 Included 0.00 0 0
25 GIS Equipment 1000004619 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS AuxiliaryBus module for Spare Transformer as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
26 GIS Equipment 1000004612 85359030 18 420kV, 3150 A, 50 kA, SF6 GIS AuxiliaryBus module for Spare Bus Reactor as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0
27 GIS Testing and maintainance equipment 1000024690 85389000 18 EOT Crane for GIS Building for 220kV GIS Station SET 1 Included 0.00 0 0
28 GIS Testing and maintainance equipment 1000024691 85389000 18 EOT Crane for GIS Building for 400kV GIS station SET 1 Included 0.00 0 0
29 GIS Testing and maintainance equipment 1000025329 90318000 18 Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 Included 0.00 0 0
30 GIS Testing and maintainance equipment 1000025436 90271000 18 SF6 Gas Leakage Detector EA 1 Included 0.00 0 0
31 GIS Testing and maintainance equipment 1000032132 85389000 18 SF6 GAS ANALYZER EA 1 Included 0.00 0 0
32 GIS Testing and maintainance equipment 1000025440 85389000 18 SF6 Gas processing Unit for 400kV GIS station SET 1 Included 0.00 0 0
33 Control and protection 1000003407 85371000 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0
34 Control and protection 1000003398 85371000 18 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0
35 Control and protection 1000004274 85371000 18 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 2 Included 0.00 0 0
36 Control and protection 1000002145 85371000 18 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0
37 Control and protection 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 9 Included 0.00 0 0
38 Control and protection 1000001166 85371000 18 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included 0.00 0 0
39 Control and protection 1000055443 85371000 18 220KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 3 Included 0.00 0 0
40 Control and protection 1000025391 82032000 18 Relay Test kit EA 1 Included 0.00 0 0
41 Control and protection 1000021642 85371000 18 Time synchronisation equipment EA 1 Included 0.00 0 0
42 SAS 1000003408 85371000 18 Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 6 Included 0.00 0 0
43 SAS 1000003410 85371000 18 Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 3 Included 0.00 0 0
44 SAS 1000001332 85371000 18 Complete Substation automation System for 220kV bay as per TechnicalSpecification EA 3 Included 0.00 0 0
45 SAS 1000018700 85371000 18 Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included 0.00 0 0
46 Power cables 1000032045 85446090 18 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2 Included 0.00 0 0
47 Power cables 1000031951 85446090 18 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included 0.00 0 0
48 Power cables 1000031919 85446090 18 1.1KV GRADE 1CX630 SQ. MM (XLPE) POWER CABLE KM 2 Included 0.00 0 0
49 Power cables 1000031911 85446020 18 1.1KV GRADE 1CX150 SQMM (PVC) POWER CABLE KM 1.5 Included 0.00 0 0
50 Power cables 1000031957 85446020 18 1.1KV GRADE 3.5CX70 SQMM (PVC) POWER CABLE KM 1.5 Included 0.00 0 0
51 Power cables 1000031953 85446020 18 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 3 Included 0.00 0 0
52 Power cables 1000031976 85446020 18 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 8 Included 0.00 0 0
53 Power cables 1000031943 85446020 18 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.5 Included 0.00 0 0
54 Power cables 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 3 Included 0.00 0 0
55 Control cables 1000031964 85446020 18 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 8 Included 0.00 0 0
56 Control cables 1000031987 85446020 18 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 15 Included 0.00 0 0
57 Control cables 1000031887 85446020 18 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 3 Included 0.00 0 0
58 Control cables 1000056264 85446020 18 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 2 Included 0.00 0 0
59 Control cables 1000056265 85446020 18 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 2.5 Included 0.00 0 0
60 Control cables 1000032049 85446020 18 4PAIR, 0.5 SQ.MM SCREENED CABLE KM 0.5 Included 0.00 0 0
61 400kV Hardware fittings 1000055986 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0.00 0 0
62 400kV Hardware fittings 1000055991 72169990 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0.00 0 0
63 Erection hardware 1000011295 72169990 18 Erection Hardware for the 33kV equipment for SEB supply as pertechnical specification SET 1 Included 0.00 0 0
64 Erection hardware 1000032412 85049010 18 ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included 0.00 0 0
65 Erection hardware 1000011348 72169990 18 Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included 0.00 0 0
66 Erection hardware 1000011252 72169990 18 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Transformer bay as per technical specification SET 2 Included 0.00 0 0
67 Erection hardware 1000011333 72169990 18 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Bus Reactor bay as per technical specification SET 1 Included 0.00 0 0
68 Erection hardware 1000011336 72169990 18 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 Included 0.00 0 0
69 Erection hardware 1000011334 72169990 18 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Transformer bay as per technical specification SET 2 Included 0.00 0 0
70 Erection hardware 1000057274 85049010 18 Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 420KV and neutral bushings terminal connectors etc for Neutral formationfor One (1) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to neutral grounding Reactors (asapplicable) and making connection arrangement to connect spare unit inplace of any unit of all the banks without pysical shifting LOT 1 Included 0.00 0 0
71 Erection hardware 1000029293 85049010 18 Neutral/Delta formation for each 3-phase 4200/220KV transformer bankincluding spare unit SET 2 Included 0.00 0 0
72 Equipment Structure 1000049654 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 6 Included 0.00 0 0
73 Equipment Structure 1000049655 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 17 Included 0.00 0 0
74 Equipment Structure 1000049652 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 32 Included 0.00 0 0
75 Equipment Structure 1000049656 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included 0.00 0 0
76 Equipment Structure 1000049649 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CLASS SA (1PH) EA 7 Included 0.00 0 0
77 Equipment Structure 1000049646 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV BPI (1PH) EA 27 Included 0.00 0 0
78 LT switchgear 1000004313 85371000 18 415V Main Switchboard SET 1 Included 0.00 0 0
79 LT switchgear 1000004303 85371000 18 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included 0.00 0 0
80 LT switchgear 1000004310 85371000 18 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included 0.00 0 0
81 LT switchgear 1000004754 85371000 18 48V DCDB SET 2 Included 0.00 0 0
82 LT switchgear 1000001144 85371000 18 220V DCDB SET 2 Included 0.00 0 0
83 LT switchgear 1000004307 85371000 18 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0
84 Battery and Battrey charger 1000037382 85072000 28 VRLA BATTERY BANK 220V 700AH SET 2 Included 0.00 0 0
85 Battery and Battrey charger 1000037384 85072000 28 VRLA BATTERY BANK 48V 700AH SET 2 Included 0.00 0 0
86 Battery and Battrey charger 1000001147 85044030 18 220V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0
87 Battery and Battrey charger 1000004758 85044030 18 48V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0
88 72.5kV and 36kV Equipment 1000002087 85353090 18 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0.00 0 0
89 72.5kV and 36kV Equipment 1000002032 85462040 18 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included 0.00 0 0
90 72.5kV and 36kV Equipment 1000020418 85354010 18 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0
91 72.5kV and 36kV Equipment 1000005070 85353090 18 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0.00 0 0
92 72.5kV and 36kV Equipment 1000005030 85462040 18 72.5kV ,1 phase Bus Post Insulators EA 6 Included 0.00 0 0
93 72.5kV and 36kV Equipment 1000005048 85359090 18 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0
94 72.5kV and 36kV Equipment 1000005061 85359090 18 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0
95 72.5kV and 36kV Equipment 1000005036 85352113 18 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0
96 72.5kV and 36kV Equipment 1000028100 85049010 18 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included 0.00 0 0
97 Structures-72.5 and 33kV Equipment 1000049660 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included 0.00 0 0
98 Structures-72.5 and 33kV Equipment 1000049661 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included 0.00 0 0
99 Structures-72.5 and 33kV Equipment 1000049658 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 6 Included 0.00 0 0
100 Structures-72.5 and 33kV Equipment 1000028542 73082011 18 STRUCTURE FOR-33KV H-TYPE POLE STRUCTURE EA 1 Included 0.00 0 0
101 Structures-72.5 and 33kV Equipment 1000049659 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included 0.00 0 0
102 PLCC Equipment-Nange 1000010014 85176210 18 Coupling device for PLCC SET 1 Included 0.00 0 0
103 PLCC Equipment-Nange 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0.00 0 0
104 PLCC Equipment-Nange 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 1 Included 0.00 0 0
105 PLCC Equipment-Nange 1000010638 85176210 18 Digital Protection Coupler EA 1 Included 0.00 0 0
106 PLCC Equipment-Nange 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included 0.00 0 0
107 PLCC Equipment-Nange 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 Included 0.00 0 0
108 PLCC Equipment-Nange 1000011082 85176210 18 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0
109 PLCC Equipment-Nange 1000004400 85462040 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0
110 PLCC Equipment-Nange 1000004290 85176210 18 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0
111 PLCC Equipment-Nange 1000001104 85176210 18 2wire telephone equipment EA 2 Included 0.00 0 0
112 PLCC Equipment-Koldam 1000010014 85176210 18 Coupling device for PLCC SET 1 Included 0.00 0 0
113 PLCC Equipment-Koldam 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0.00 0 0
114 PLCC Equipment-Koldam 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 1 Included 0.00 0 0
115 PLCC Equipment-Koldam 1000010638 85176210 18 Digital Protection Coupler EA 1 Included 0.00 0 0
116 DG SET 1000001893 85021200 18 250 kVA Diesel Generator along with control Panel SET 1 Included 0.00 0 0
117 Ventilation System 1000022408 84159000 28 Ventillation system for 400KV GIS Hall SET 1 Included 0.00 0 0
118 Ventilation System 1000022406 84159000 28 Ventillation system for 220KV GIS Hall SET 1 Included 0.00 0 0
119 Air Conditioning System 1000013502 84158210 28 High wall type split AC unit of 2 TR capacity EA 30 Included 0.00 0 0
120 Main Earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 5 Included 0.00 0 0
121 Fire Protection System 1000012014 85311020 18 Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included 0.00 0 0
122 Fire Protection System 1000012010 85311020 18 Fire Detection and Alarm System for 400kV GIS Hall SET 1 Included 0.00 0 0
123 Fire Protection System 1000012009 85311020 18 Fire Detection and Alarm System for 220kV GIS Hall SET 1 Included 0.00 0 0
124 Fire Protection System 1000049665 84241000 18 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 2 Included 0.00 0 0
125 Fire Protection System 1000012024 84241000 18 Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 10 Included 0.00 0 0
126 Fire Protection System 1000012027 84241000 18 9litre water type Portable Fire extinguisher EA 10 Included 0.00 0 0
127 Fire Protection System 1000012022 84241000 18 4.5 kg CO2 type Portable Fire extinguisher EA 10 Included 0.00 0 0
128 Fire Protection System 1000012064 84248990 18 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 105 MVA ,400 kV, 1-phaseAutotransformer SET 7 Included 0.00 0 0
129 Fire Protection System 1000057271 84248990 18 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 41.67 MVAR, 420kV, 1 phaseReactor SET 4 Included 0.00 0 0
130 Fire Protection System 1000012031 84819090 18 Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included 0.00 0 0
131 Illumination System- Indoor 1000049467 94059900 18 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 Included 0.00 0 0
132 Illumination System- Indoor 1000049469 94059900 18 INDOOR LIGHTNING FOR DG SET & FIRE FIGHTING PUMP HOUSE SET 1 Included 0.00 0 0
133 Illumination System- Indoor 1000030151 94059900 18 Security Room Illumination including conduit LS 1 Included 0.00 0 0
134 Illumination System- Indoor 1000009647 94059900 18 Control room cum administrative building (400kV) illumination LOT 1 Included 0.00 0 0
135 Illumination System- Outdoor 1000017691 94059900 18 Post top Lantern tubular pole EA 10 Included 0.00 0 0
136 Illumination System- Outdoor 1000038388 94051090 18 POLE MOUNTED LED POST TOP LUMINAIRE TYPE SL-D1 (= 30W)AS PER TECHNICALSPECIFICATION EA 10 Included 0.00 0 0
137 Illumination System- Outdoor 1000001050 94059900 18 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 3 Included 0.00 0 0
138 Illumination System- Outdoor 1000025538 76169990 18 Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 0
139 Illumination System- Outdoor 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included 0.00 0 0
140 Illumination System- Outdoor 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 4 Included 0.00 0 0
141 Illumination System- Outdoor 1000038397 94059900 18 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 30 Included 0.00 0 0
142 Illumination System- Outdoor 1000038042 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE SL-L1 AS PER TECH. SPECIFICATIONS EA 30 Included 0.00 0 0
143 Illumination System- Outdoor 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 15 Included 0.00 0 0
144 Illumination System- Outdoor 1000038039 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 30 Included 0.00 0 0
145 Illumination System- Outdoor 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 8 Included 0.00 0 0
146 Gantry Structure 1000054362 73045930 18 LINE TAKEOFF GANTRY STRUCTURE FOR A 420 KV LINE IN GIS SUBSTATIONINCLUDING FOUNDATION BOLT, ALL TYPES OF NUT, BOLT, WASHERS ETC EA 2 Included 0.00 0 0
147 Visual Monitoring System 1000025861 85287390 18 Visual Monitoring System for Watch & Ward SET 1 Included 0.00 0 0
148 Mandatory spares AIS & General-LS 1000025943 85359090 18 Spare-420kV CVT 1 SET 1 Included 0.00 0 0
149 Mandatory spares AIS & General-LS 1000028266 85049010 18 Spares for 420kV Shunt Reactor LS 1 Included 0.00 0 0
150 Mandatory spares AIS & General-LS 1000026087 85354010 18 Spares for 120kV Surge Arrester LS 1 Included 0.00 0 0
151 Mandatory spares AIS & General-LS 1000024186 85354010 18 SPARES FOR 336KV SURGE ARRESTER LS 1 Included 0.00 0 0
152 Mandatory spares AIS & General-LS 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 Included 0.00 0 0
153 Mandatory spares AIS & General-LS 1000019927 85389000 18 Spares-Substation Automation System LS 1 Included 0.00 0 0
154 Mandatory spares AIS & General-LS 1000025950 85176210 18 Spare-PLCC SET 1 Included 0.00 0 0
155 Mandatory spares AIS & General-LS 1000019925 84819090 18 Spares for Fire Protection System LS 1 Included 0.00 0 0
156 Mandatory spares AIS & General-LS 1000019915 85030010 18 Spares for DG set LS 1 Included 0.00 0 0
157 Mandatory spares AIS & General-LS 1000019913 85079090 28 Spares for 220V Batteries LS 1 Included 0.00 0 0
158 Mandatory spares AIS & General-LS 1000019920 85079090 28 Spares for 48V Batteries LS 1 Included 0.00 0 0
159 Mandatory spares AIS & General-LS 1000019914 85049090 18 Spares fpr 220V Battery Charger LS 1 Included 0.00 0 0
160 Mandatory spares AIS & General-LS 1000019921 85044030 18 Spares fpr 48V Battery Charger LS 1 Included 0.00 0 0
161 Mandatory spares AIS & General-LS 1000025940 85462040 18 Spare-420kV BPI SET 1 Included 0.00 0 0
162 Mandatory spares AIS & General-LS 1000025932 85462040 18 Spare-245kV BPI SET 1 Included 0.00 0 0
163 Mandatory spares AIS & General-LS 1000025930 85354010 18 Spare-216kV Surge Arrester SET 1 Included 0.00 0 0
164 Mandatory spares AIS & General-LS 1000053851 76169990 18 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included 0.00 0 0
165 Mandatory spares AIS & General-LS 1000025980 85446020 18 Power and Control Cables LS 1 Included 0.00 0 0
166 Mandatory spares 400kV GIS 1000058332 85359030 18 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 Included 0.00 0 0
167 Mandatory spares 400kV GIS 1000049817 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 3 Included 0.00 0 0
168 Mandatory spares 400kV GIS 1000049753 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 2 Included 0.00 0 0
169 Mandatory spares 400kV GIS 1000049762 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 3 Included 0.00 0 0
170 Mandatory spares 400kV GIS 1000058330 85359030 18 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 Included 0.00 0 0
171 Mandatory spares 400kV GIS 1000049750 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 3 Included 0.00 0 0
172 Mandatory spares 400kV GIS 1000058331 85359030 18 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 Included 0.00 0 0
173 Mandatory spares 400kV GIS 1000049783 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 3 Included 0.00 0 0
174 Mandatory spares 400kV GIS 1000049505 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 5 Included 0.00 0 0
175 Mandatory spares 400kV GIS 1000058334 85359030 18 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included 0.00 0 0
176 Mandatory spares 400kV GIS 1000058329 85359030 18 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included 0.00 0 0
177 Mandatory spares 400kV GIS 1000058333 85359030 18 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 Included 0.00 0 0
178 Mandatory spares 400kV GIS 1000049498 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 2 Included 0.00 0 0
179 Mandatory spares 400kV GIS 1000058317 85359030 18 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 Included 0.00 0 0
180 Mandatory spares 400kV GIS 1000058316 85359030 18 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 Included 0.00 0 0
181 Mandatory spares 400kV GIS 1000021873 85389000 18 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 Included 0.00 0 0
182 Mandatory spares 400kV GIS 1000009208 85389000 18 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 Included 0.00 0 0
183 Mandatory spares 400kV GIS 1000058324 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 Included 0.00 0 0
184 Mandatory spares 400kV GIS 1000007067 85389000 18 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 3 Included 0.00 0 0
185 Mandatory spares 400kV GIS 1000058323 85359030 18 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 Included 0.00 0 0
186 Mandatory spares 400kV GIS 1000058320 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
187 Mandatory spares 400kV GIS 1000049759 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
188 Mandatory spares 400kV GIS 1000058319 85359030 18 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
189 Mandatory spares 400kV GIS 1000058322 85359030 18 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
190 Mandatory spares 400kV GIS 1000049835 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
191 Mandatory spares 400kV GIS 1000049795 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
192 Mandatory spares 400kV GIS 1000049808 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
193 Mandatory spares 400kV GIS 1000049805 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
194 Mandatory spares 400kV GIS 1000058321 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
195 Mandatory spares 400kV GIS 1000049799 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
196 Mandatory spares 400kV GIS 1000058325 85359030 18 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 Included 0.00 0 0
197 Mandatory spares 400kV GIS 1000058318 85359030 18 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
198 Mandatory spares 400kV GIS 1000049495 85359030 18 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 Included 0.00 0 0
199 Mandatory spares 400kV GIS 1000049802 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
200 Mandatory spares 400kV GIS 1000058374 85359030 18 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 Included 0.00 0 0
201 Mandatory spares 400kV GIS 1000058314 85359030 18 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 Included 0.00 0 0
202 Mandatory spares 400kV GIS 1000058310 85359030 18 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 Included 0.00 0 0
203 Mandatory spares 400kV GIS 1000058305 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 Included 0.00 0 0
204 Mandatory spares 400kV GIS 1000058312 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 Included 0.00 0 0
205 Mandatory spares 400kV GIS 1000058308 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH SET 1 Included 0.00 0 0
206 Mandatory spares 400kV GIS 1000049776 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 2 Included 0.00 0 0
207 Mandatory spares 400kV GIS 1000049778 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 2 Included 0.00 0 0
208 Mandatory spares 400kV GIS 1000049777 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS SET 2 Included 0.00 0 0
209 Mandatory spares 400kV GIS 1000058306 85359030 18 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 Included 0.00 0 0
210 Mandatory spares 400kV GIS 1000058313 85359030 18 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 Included 0.00 0 0
211 Mandatory spares 400kV GIS 1000058309 85359030 18 DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH SET 1 Included 0.00 0 0
212 Mandatory spares 400kV GIS 1000058307 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 Included 0.00 0 0
213 Mandatory spares 400kV GIS 1000058315 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 Included 0.00 0 0
214 Mandatory spares 400kV GIS 1000058311 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH EA 1 Included 0.00 0 0
215 Mandatory spares 400kV GIS 1000058327 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 Included 0.00 0 0
216 Mandatory spares 400kV GIS 1000058326 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 Included 0.00 0 0
217 Mandatory spares 400kV GIS 1000058328 85359030 18 400KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 Included 0.00 0 0
218 Mandatory spares 220kV GIS 1000058295 85359030 18 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 Included 0.00 0 0
219 Mandatory spares 220kV GIS 1000058300 85359030 18 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 Included 0.00 0 0
220 Mandatory spares 220kV GIS 1000049816 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 3 Included 0.00 0 0
221 Mandatory spares 220kV GIS 1000049752 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 2 Included 0.00 0 0
222 Mandatory spares 220kV GIS 1000049761 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 3 Included 0.00 0 0
223 Mandatory spares 220kV GIS 1000058298 85359030 18 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 Included 0.00 0 0
224 Mandatory spares 220kV GIS 1000049749 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 3 Included 0.00 0 0
225 Mandatory spares 220kV GIS 1000058299 85359030 18 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 Included 0.00 0 0
226 Mandatory spares 220kV GIS 1000049782 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 3 Included 0.00 0 0
227 Mandatory spares 220kV GIS 1000049504 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 5 Included 0.00 0 0
228 Mandatory spares 220kV GIS 1000058302 85359030 18 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included 0.00 0 0
229 Mandatory spares 220kV GIS 1000058297 85359030 18 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included 0.00 0 0
230 Mandatory spares 220kV GIS 1000058301 85359030 18 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 Included 0.00 0 0
231 Mandatory spares 220kV GIS 1000049497 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 2 Included 0.00 0 0
232 Mandatory spares 220kV GIS 1000058284 85359030 18 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included 0.00 0 0
233 Mandatory spares 220kV GIS 1000058286 85359030 18 220KV GIS-ONE POLE OF 2500A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included 0.00 0 0
234 Mandatory spares 220kV GIS 1000058285 85359030 18 220KV GIS-ONE POLE OF 3000A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included 0.00 0 0
235 Mandatory spares 220kV GIS 1000021871 85389000 18 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 Included 0.00 0 0
236 Mandatory spares 220kV GIS 1000009185 85389000 18 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 1 Included 0.00 0 0
237 Mandatory spares 220kV GIS 1000058292 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 Included 0.00 0 0
238 Mandatory spares 220kV GIS 1000007066 85389000 18 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 3 Included 0.00 0 0
239 Mandatory spares 220kV GIS 1000058291 85359030 18 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 Included 0.00 0 0
240 Mandatory spares 220kV GIS 1000058288 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
241 Mandatory spares 220kV GIS 1000049758 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
242 Mandatory spares 220kV GIS 1000058272 85359030 18 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
243 Mandatory spares 220kV GIS 1000058290 85359030 18 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
244 Mandatory spares 220kV GIS 1000049834 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
245 Mandatory spares 220kV GIS 1000049794 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
246 Mandatory spares 220kV GIS 1000049807 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
247 Mandatory spares 220kV GIS 1000049804 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
248 Mandatory spares 220kV GIS 1000058289 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
249 Mandatory spares 220kV GIS 1000049798 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
250 Mandatory spares 220kV GIS 1000058293 85359030 18 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 Included 0.00 0 0
251 Mandatory spares 220kV GIS 1000058287 85359030 18 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 Included 0.00 0 0
252 Mandatory spares 220kV GIS 1000049797 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 Included 0.00 0 0
253 Mandatory spares 220kV GIS 1000049801 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0
254 Mandatory spares 220kV GIS 1000058371 85359030 18 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 Included 0.00 0 0
255 Mandatory spares 220kV GIS 1000058372 85359030 18 220kV GIS- Three phase of 2500Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 Included 0.00 0 0
256 Mandatory spares 220kV GIS 1000058373 85359030 18 220kV GIS- Three phase of 3000Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 Included 0.00 0 0
257 Mandatory spares 220kV GIS 1000058282 85359030 18 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 Included 0.00 0 0
258 Mandatory spares 220kV GIS 1000058278 85359030 18 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 Included 0.00 0 0
259 Mandatory spares 220kV GIS 1000058273 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 Included 0.00 0 0
260 Mandatory spares 220kV GIS 1000058280 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 Included 0.00 0 0
261 Mandatory spares 220kV GIS 1000058276 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 Included 0.00 0 0
262 Mandatory spares 220kV GIS 1000049773 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 2 Included 0.00 0 0
263 Mandatory spares 220kV GIS 1000049775 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 2 Included 0.00 0 0
264 Mandatory spares 220kV GIS 1000049774 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 2 Included 0.00 0 0
265 Mandatory spares 220kV GIS 1000058274 85359030 18 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 Included 0.00 0 0
266 Mandatory spares 220kV GIS 1000058281 85359030 18 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 Included 0.00 0 0
267 Mandatory spares 220kV GIS 1000058277 85359030 18 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 Included 0.00 0 0
268 Mandatory spares 220kV GIS 1000058275 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 Included 0.00 0 0
269 Mandatory spares 220kV GIS 1000058283 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 Included 0.00 0 0
270 Mandatory spares 220kV GIS 1000058279 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 Included 0.00 0 0
271 Mandatory spares 220kV GIS 1000058294 85359030 18 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 Included 0.00 0 0
272 Mandatory spares 220kV GIS 1000058296 85359030 18 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 Included 0.00 0 0
273 Mandatory spares 220kV GIS 1000058303 85359030 18 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 Included 0.00 0 0
274 Mandatory spares 220kV GIS 1000058304 85359030 18 220KV GIS- SURGE COUNTER/ MONITOR EA 1 Included 0.00 0 0
275 Tower-Structure 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 14 Included 0.00 0 0
276 Tower-Structure 1000015953 73082011 18 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 17 Included 0.00 0 0
277 Tower-Structure 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2 Included 0.00 0 0
278 Tower-Structure 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 3 Included 0.00 0 0
279 PMU & associated items (Nange SS) 1000017518 85364900 18 PMU with GPS Clock (clock can be either internal or external) EA 2 Included 0.00 0 0
280 PMU & associated items (Nange SS) 1000022512 90311000 18 WAMS Hardware - Time System (GPS receiver) EA 2 Included 0.00 0 0
281 PMU & associated items (Nange SS) 1000022510 85176290 18 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included 0.00 0 0
282 PMU & associated items (Nange SS) 1000022487 85447090 18 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0
283 Tele Eqpt at Nange GIS 1000031367 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0
284 Tele Eqpt at Nange GIS 1000014273 85176990 18 L16.2 SFP EA 2 Included 0.00 0 0
285 Tele Eqpt at Nange GIS 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0
286 Tele Eqpt at Nange GIS 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0
287 Tele Eqpt at Nange GIS 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0
288 Tele Eqpt at Nange GIS 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 Included 0.00 0 0
289 Tele Eqpt at Nange GIS 1000028495 84715000 18 NMS- CRAFT TERMINAL-HARDWARE EA 1 Included 0.00 0 0
290 Tele Eqpt at Nange GIS 1000028265 85238020 18 Software for Craft Terminal EA 1 Included 0.00 0 0
291 Tele Eqpt at Nange GIS 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included 0.00 0 0
292 Tele Eqpt at Nange GIS 1000030942 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included 0.00 0 0
293 Tele Eqpt at Nange GIS 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included 0.00 0 0
294 Spares-Tele Eqpt at Nange GIS 1000031369 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included 0.00 0 0
295 Spares-Tele Eqpt at Nange GIS 1000018706 85176990 18 S16.1 SFP EA 1 Included 0.00 0 0
296 Spares-Tele Eqpt at Nange GIS 1000014273 85176990 18 L16.2 SFP EA 1 Included 0.00 0 0
297 Spares-Tele Eqpt at Nange GIS 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included 0.00 0 0
298 Spares-Tele Eqpt at Nange GIS 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included 0.00 0 0
299 Spares-Tele Eqpt at Nange GIS 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0
300 Spares-Tele Eqpt at Nange GIS 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included 0.00 0 0
301 Spares-Tele Eqpt at Nange GIS 1000031398 85171890 18 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included 0.00 0 0
302 Spares-Tele Eqpt at Nange GIS 1000030942 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included 0.00 0 0
II 400kV Koldam Extn.
303 400kV Bus Reactor 1000057268 85042330 18 41.67MVAR, 420kV, 1-phase Reactor excluding Insulating Oil EA 4 Included 0.00 0 0
304 400kV Bus Reactor 1000057272 85049010 18 Insulating Oil for 41.67MVAR, 420kV 1-phase Reactor SET 4 Included 0.00 0 0
305 400kV AIS Equipment 1000004501 85352913 18 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 2 Included 0.00 0 0
306 400kV AIS Equipment 1000004463 85359090 18 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 6 Included 0.00 0 0
307 400kV AIS Equipment 1000004535 85359090 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 3 Included 0.00 0 0
308 400kV AIS Equipment 1000004498 85353090 18 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 6 Included 0.00 0 0
309 400kV AIS Equipment 1000020419 85354010 18 336kV Surge Arrester (1-phase) EA 3 Included 0.00 0 0
310 400kV AIS Equipment 1000004401 85462040 18 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 16 Included 0.00 0 0
311 Erection Hardware 1000011301 72169990 18 Erection Hardware for 400kV D type layout-Line bay as per technicalspecification SET 1 Included 0.00 0 0
312 Erection Hardware 1000011298 72169990 18 Erection Hardware for 400kV D type layout-Bus Reactor bay as pertechnical specification SET 1 Included 0.00 0 0
313 400kV Insulator &Hardware 1000055991 72169990 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0.00 0 0
314 400kV Insulator &Hardware 1000055988 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0.00 0 0
315 400kV Insulator &Hardware 1000055986 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0.00 0 0
316 400kV Insulator &Hardware 1000055984 72169990 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0.00 0 0
317 Control & Relay Panels 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 Included 0.00 0 0
318 Control & Relay Panels 1000003398 85371000 18 400kV Line Protection Panel (with Automation) EA 1 Included 0.00 0 0
319 Control & Relay Panels 1000002146 85371000 18 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 Included 0.00 0 0
320 Control & Relay Panels 1000003407 85371000 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0
321 Substation Automation 1000003409 85371000 18 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 Included 0.00 0 0
322 Substation Automation 1000003411 85371000 18 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 Included 0.00 0 0
323 PLCC Equipment 1000004290 85176210 18 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included 0.00 0 0
324 PLCC Equipment 1000004400 85462040 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 6 Included 0.00 0 0
325 Indoor Illumination system 1000013795 94059900 18 Illumination System for switchyard panel room of 6 m length LS 1 Included 0.00 0 0
326 Outdoor Illumination System 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0
327 Outdoor Illumination System 1000038039 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 Included 0.00 0 0
328 Outdoor Illumination System 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 Included 0.00 0 0
329 Outdoor Illumination System 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 Included 0.00 0 0
330 FF system 1000012018 85311020 18 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 Included 0.00 0 0
331 FF system 1000012022 84241000 18 4.5 kg CO2 type Portable Fire extinguisher EA 4 Included 0.00 0 0
332 FF system 1000012026 84241000 18 6Kg dry chemical powered type Portable Fire extinguisher EA 2 Included 0.00 0 0
333 FF system 1000057271 84248990 18 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 41.67 MVAR, 420kV, 1 phaseReactor SET 4 Included 0.00 0 0
334 Air condition 1000006284 84151090 28 Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included 0.00 0 0
335 Power and Control Cables 1000031964 85446020 18 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 1.2 Included 0.00 0 0
336 Power and Control Cables 1000031987 85446020 18 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 3 Included 0.00 0 0
337 Power and Control Cables 1000031887 85446020 18 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 4 Included 0.00 0 0
338 Power and Control Cables 1000056264 85446020 18 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 1 Included 0.00 0 0
339 Power and Control Cables 1000056265 85446020 18 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 0.4 Included 0.00 0 0
340 Power and Control Cables 1000031953 85446020 18 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1.6 Included 0.00 0 0
341 Power and Control Cables 1000031943 85446020 18 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 1 Included 0.00 0 0
342 Power and Control Cables 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 1 Included 0.00 0 0
343 Power and Control Cables 1000031976 85446020 18 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 6.5 Included 0.00 0 0
344 Power and Control Cables 1000031951 85446090 18 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included 0.00 0 0
345 Earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 1 Included 0.00 0 0
346 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included 0.00 0 0
347 Equipment Structure 1000049653 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 6 Included 0.00 0 0
348 Equipment Structure 1000049654 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 3 Included 0.00 0 0
349 Equipment Structure 1000049655 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 3 Included 0.00 0 0
350 Equipment Structure 1000049657 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 7 Included 0.00 0 0
351 Equipment Structure 1000049652 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 16 Included 0.00 0 0
352 Equipment Structure 1000049656 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 2 Included 0.00 0 0
353 Gantry Structure 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 9 Included 0.00 0 0
354 Gantry Structure 1000015953 73082011 18 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 11 Included 0.00 0 0
355 Gantry Structure 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included 0.00 0 0
356 Gantry Structure 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included 0.00 0 0
357 Mandatory Spares 1000019918 85359090 18 Spares for 420kV Circuit Breaker LS 1 Included 0.00 0 0
358 Mandatory Spares 1000019919 85353090 18 Spares for 420kV Double break Isolator LS 1 Included 0.00 0 0
359 Mandatory Spares 1000024186 85354010 18 SPARES FOR 336KV SURGE ARRESTER LS 1 Included 0.00 0 0
360 Mandatory Spares 1000025943 85359090 18 Spare-420kV CVT 1 SET 1 Included 0.00 0 0
361 Mandatory Spares 1000025941 85389000 18 Spare-420kV CT 1 SET 1 Included 0.00 0 0
362 Mandatory Spares 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 Included 0.00 0 0
363 Mandatory Spares 1000019927 85389000 18 Spares-Substation Automation System LS 1 Included 0.00 0 0
364 Mandatory Spares 1000025950 85176210 18 Spare-PLCC SET 1 Included 0.00 0 0
365 Mandatory Spares 1000053851 76169990 18 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included 0.00 0 0
366 Mandatory Spares 1000028245 85049010 18 Spare For 400kV Bus Reactor LS 1 Included 0.00 0 0
367 PMU & associated items (Koldam SS) 1000017518 85364900 18 PMU with GPS Clock (clock can be either internal or external) EA 1 Included 0.00 0 0
368 PMU & associated items (Koldam SS) 1000022512 90311000 18 WAMS Hardware - Time System (GPS receiver) EA 1 Included 0.00 0 0
369 PMU & associated items (Koldam SS) 1000022510 85176290 18 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 2 Included 0.00 0 0
370 PMU & associated items (Koldam SS) 1000022487 85447090 18 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0
371 Tele Eqpt at Koldam 1000031367 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0
372 Tele Eqpt at Koldam 1000018706 85176990 18 S16.1 SFP EA 4 Included 0.00 0 0
373 Tele Eqpt at Koldam 1000014273 85176990 18 L16.2 SFP EA 2 Included 0.00 0 0
374 Tele Eqpt at Koldam 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0
375 Tele Eqpt at Koldam 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0
376 Tele Eqpt at Koldam 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0
377 Tele Eqpt at Koldam 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 Included 0.00 0 0
378 Tele Eqpt at Koldam 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 Included 0.00 0 0
379 Tele Eqpt at Koldam 1000030942 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included 0.00 0 0
380 Tele Eqpt at Koldam 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included 0.00 0 0
III Switchable Line Rector at Ropar
381 50 MVAR Line Reactor 1000004900 85042310 18 50 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 1 Included 0.00 0 0
382 50 MVAR Line Reactor 1000014013 85049010 18 Insulating Oil for 50 MVAR,420kV ,3-phase Shunt Reactor SET 1 Included 0.00 0 0
383 50 MVAR Line Reactor 1000015913 85049010 18 Oil filled Neutral Grounding Reactor (NGR) along with supportstructure & terminal connector EA 1 Included 0.00 0 0
384 AIS Equipment 1000004501 85352913 18 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 1 Included 0.00 0 0
385 AIS Equipment 1000004498 85353090 18 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 1 Included 0.00 0 0
386 AIS Equipment 1000020419 85354010 18 336kV Surge Arrester (1-phase) EA 3 Included 0.00 0 0
387 AIS Equipment 1000020416 85354010 18 120kV Surge Arrester(1-phase) EA 1 Included 0.00 0 0
388 AIS Equipment 1000004401 85462040 18 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 3 Included 0.00 0 0
389 Erection Hardware 1000011321 72169990 18 Erection Hardware for 400kV I type layout-Line Reactor including NGRbypass arrangement as per technical specification SET 1 Included 0.00 0 0
390 400kV Insulator &Hardware 1000055986 72169990 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0.00 0 0
391 Control & Relay Panels 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 Included 0.00 0 0
392 Control & Relay Panels 1000003407 85371000 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0
393 Control & Relay Panels 1000009713 85389000 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 Included 0.00 0 0
394 Substation Automation 1000003413 85371000 18 Complete Substation automation System for 400kV Switchable LineReactor Bay as per Technical Specification EA 1 Included 0.00 0 0
395 Outdoor Illumination System 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0
396 Outdoor Illumination System 1000038039 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 2 Included 0.00 0 0
397 Outdoor Illumination System 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 Included 0.00 0 0
398 Outdoor Illumination System 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 Included 0.00 0 0
399 FF system 1000012045 84248990 18 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 50 MVAR, 420kV, 3 phaseshunt Reactor SET 1 Included 0.00 0 0
400 Power and Control Cables 1000031887 85446020 18 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 Included 0.00 0 0
401 Power and Control Cables 1000056264 85446020 18 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 0.5 Included 0.00 0 0
402 Power and Control Cables 1000056265 85446020 18 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 0.4 Included 0.00 0 0
403 Power and Control Cables 1000031953 85446020 18 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 0.8 Included 0.00 0 0
404 Power and Control Cables 1000031943 85446020 18 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.5 Included 0.00 0 0
405 Power and Control Cables 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.5 Included 0.00 0 0
406 Power and Control Cables 1000031976 85446020 18 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 Included 0.00 0 0
407 Power and Control Cables 1000031951 85446090 18 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included 0.00 0 0
408 Earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 1 Included 0.00 0 0
409 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included 0.00 0 0
410 Equipment Structure 1000049655 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 3 Included 0.00 0 0
411 Equipment Structure 1000049657 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 1 Included 0.00 0 0
412 Equipment Structure 1000049652 73045930 18 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 3 Included 0.00 0 0
Total Ex-Works Price 0.00 0.00
Type Test Charges (as per Schedule 7) 0.00
Total Ex-Works Price (Including Type Test charges) 0.00
Note The Price quoted against Supply, F&I & Erection & commissioning for BPL Service connection Including taxes and duties shall be limited to Rs 3000/- per service connection
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date -- Printed Name:
Place Designation :
Spec.No. Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
1.1 #REF! Bought-Out
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
1.2 #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
1.3 #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
2.0 #REF! #REF!
2.1 #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
3.0 #REF! #REF!
3.1 #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF! #REF!
(e) #REF! #REF! #REF! #REF! #REF! #REF!
(f) #REF! #REF! #REF! #REF! #REF! #REF!
4.0 #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
(c ) #REF! #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
(c ) #REF! #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF! #REF!
(e ) #REF! #REF! #REF! #REF! #REF! #REF!
(f) #REF! #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF! #REF!
(c ) #REF! #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF! #REF!
(e ) #REF! #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! #REF!
(i) #REF! #REF! #REF! #REF! #REF! #REF!
(ii) #REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price C) Direct #REF! Direct
Total Ex-Works Price C) Bought Out #REF!
Total Excise Duty #REF!
Total VAT #REF!
Total CST #REF!
Type Test Charges #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
Spec.No. TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 2
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount #REF!
Gurgaon (Haryana) - 122001
Local Transportation, In-transit Insurance, loading and unloading
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. PR No. PR Line Item No Activity Description Material Code Item Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
I 400/200kV Nange GIS Bought-Out
1 400kV Bus Reactor 1000057268 41.67MVAR, 420kV, 1-phase Reactor excluding Insulating Oil EA 4 Included Bought-Out
2 400kV Bus Reactor 1000057272 Insulating Oil for 41.67MVAR, 420kV 1-phase Reactor SET 4 Included Bought-Out STP 9M SP 33
3 LT transformer 1000004951 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included
4 AIS equipment 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included
5 AIS equipment 1000020419 336kV Surge Arrester (1-phase) EA 17 Included
6 AIS equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 32 Included
7 AIS equipment 1000020417 216kV Surge Arrester (1-phase) EA 7 Included
8 AIS equipment 1000001695 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 27 Included
9 AIS equipment 1000001998 Current transformer (33kV) for transformer Netural along with supportstructure & terminal connector SET 2 Included
10 GIS Equipment 1000032699 3150A, 63KA, 1SEC SINGLE PHASE 420KV SF6 TO AIR BUSHING EA 17 Included
11 GIS Equipment 1000004287 420kV, 3000A, 63kA, Single phase, SF6Gas Insulated Bus Duct (GIB) outsideGIS Hall alongwith associated supportstructure M 500 Included
12 GIS Equipment 1000004533 420kV, 4000 A, 63 kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included
13 GIS Equipment 1000004634 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(with PIR) as perSection-Project, Technicalspecification SET 2 Included
14 GIS Equipment 1000004638 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(without PIR) as perSection-Project, Technicalspecification SET 1 Included
15 GIS Equipment 1000004505 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 Included
16 GIS Equipment 1000004635 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification SET 2 Included
17 GIS Equipment 1000004637 420kV, 3150 A, 63 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 2 Included
18 GIS Equipment 1000004632 420kV, 3150 A, 63 kA, SF6 GIS BusReactor bay module as perSection-Project, Technicalspecification SET 1 Included
19 GIS Equipment 1000009711 Controlled switching device for 420 kV, 3 phase circuit breaker SET 2 Included
20 GIS Equipment 1000001690 245kV, 1600 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 2 Included
21 GIS Equipment 1000001832 245kV, 2500 A, 50 kA, SF6 GIS Buscoupler bay module as perSection-Project, Technicalspecification SET 1 Included
22 GIS Equipment 1000001853 245 kV, 4000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included
23 GIS Equipment 1000001693 245kV,1600A, 50kA,3 Single phase/3Phase, SF6 Gas Insulated Bus Duct (GIB)outside GIS Hall alongwith associatedsupport structure(Quantity mentionedhere is for 3 Phase type) M 250 Included
24 GIS Equipment 1000029503 245kV, 1600A, 50kA Single phase SF6 to Air Bushing EA 7 Included
25 GIS Equipment 1000004619 420kV, 3150 A, 63 kA, SF6 GIS AuxiliaryBus module for Spare Transformer as perSection-Project, Technicalspecification SET 1 Included
26 GIS Equipment 1000004612 420kV, 3150 A, 50 kA, SF6 GIS AuxiliaryBus module for Spare Bus Reactor as perSection-Project, Technicalspecification SET 1 Included
27 GIS Testing and maintainance equipment 1000024690 EOT Crane for GIS Building for 220kV GIS Station SET 1 Included
28 GIS Testing and maintainance equipment 1000024691 EOT Crane for GIS Building for 400kV GIS station SET 1 Included
29 GIS Testing and maintainance equipment 1000025329 Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 Included
30 GIS Testing and maintainance equipment 1000025436 SF6 Gas Leakage Detector EA 1 Included
31 GIS Testing and maintainance equipment 1000032132 SF6 GAS ANALYZER EA 1 Included
32 GIS Testing and maintainance equipment 1000025440 SF6 Gas processing Unit for 400kV GIS station SET 1 Included
33 Control and protection 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 Included
34 Control and protection 1000003398 400kV Line Protection Panel (with Automation) EA 2 Included
35 Control and protection 1000004274 400kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 2 Included
36 Control and protection 1000002145 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included
37 Control and protection 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 9 Included
38 Control and protection 1000001166 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included
39 Control and protection 1000055443 220KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 3 Included
40 Control and protection 1000025391 Relay Test kit EA 1 Included
41 Control and protection 1000021642 Time synchronisation equipment EA 1 Included
42 SAS 1000003408 Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 6 Included
43 SAS 1000003410 Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 3 Included
44 SAS 1000001332 Complete Substation automation System for 220kV bay as per TechnicalSpecification EA 3 Included
45 SAS 1000018700 Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included
46 Power cables 1000032045 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2 Included
47 Power cables 1000031951 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included
48 Power cables 1000031919 1.1KV GRADE 1CX630 SQ. MM (XLPE) POWER CABLE KM 2 Included
49 Power cables 1000031911 1.1KV GRADE 1CX150 SQMM (PVC) POWER CABLE KM 1.5 Included
50 Power cables 1000031957 1.1KV GRADE 3.5CX70 SQMM (PVC) POWER CABLE KM 1.5 Included
51 Power cables 1000031953 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 3 Included
52 Power cables 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 8 Included
53 Power cables 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.5 Included
54 Power cables 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 3 Included
55 Control cables 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 8 Included
56 Control cables 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 15 Included
57 Control cables 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 3 Included
58 Control cables 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 2 Included
59 Control cables 1000056265 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 2.5 Included
60 Control cables 1000032049 4PAIR, 0.5 SQ.MM SCREENED CABLE KM 0.5 Included
61 400kV Hardware fittings 1000055986 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 6 Included
62 400kV Hardware fittings 1000055991 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included
63 Erection hardware 1000011295 Erection Hardware for the 33kV equipment for SEB supply as pertechnical specification SET 1 Included
64 Erection hardware 1000032412 ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included
65 Erection hardware 1000011348 Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included
66 Erection hardware 1000011252 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Transformer bay as per technical specification SET 2 Included
67 Erection hardware 1000011333 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Bus Reactor bay as per technical specification SET 1 Included
68 Erection hardware 1000011336 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 Included
69 Erection hardware 1000011334 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Transformer bay as per technical specification SET 2 Included
70 Erection hardware 1000057274 Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 420KV and neutral bushings terminal connectors etc for Neutral formationfor One (1) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to neutral grounding Reactors (asapplicable) and making connection arrangement to connect spare unit inplace of any unit of all the banks without pysical shifting LOT 1 Included
71 Erection hardware 1000029293 Neutral/Delta formation for each 3-phase 4200/220KV transformer bankincluding spare unit SET 2 Included
72 Equipment Structure 1000049654 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 6 Included
73 Equipment Structure 1000049655 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 17 Included
74 Equipment Structure 1000049652 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 32 Included
75 Equipment Structure 1000049656 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 4 Included
76 Equipment Structure 1000049649 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV CLASS SA (1PH) EA 7 Included
77 Equipment Structure 1000049646 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-220KV BPI (1PH) EA 27 Included
78 LT switchgear 1000004313 415V Main Switchboard SET 1 Included
79 LT switchgear 1000004303 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included
80 LT switchgear 1000004310 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included
81 LT switchgear 1000004754 48V DCDB SET 2 Included
82 LT switchgear 1000001144 220V DCDB SET 2 Included
83 LT switchgear 1000004307 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included
84 Battery and Battrey charger 1000037382 VRLA BATTERY BANK 220V 700AH SET 2 Included
85 Battery and Battrey charger 1000037384 VRLA BATTERY BANK 48V 700AH SET 2 Included
86 Battery and Battrey charger 1000001147 220V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included
87 Battery and Battrey charger 1000004758 48V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included
88 72.5kV and 36kV Equipment 1000002087 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included
89 72.5kV and 36kV Equipment 1000002032 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included
90 72.5kV and 36kV Equipment 1000020418 30kV Surge Arrester (1-Phase) EA 3 Included
91 72.5kV and 36kV Equipment 1000005070 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included
92 72.5kV and 36kV Equipment 1000005030 72.5kV ,1 phase Bus Post Insulators EA 6 Included
93 72.5kV and 36kV Equipment 1000005048 72.5 kV Voltage Transformer (1- Phase) EA 3 Included
94 72.5kV and 36kV Equipment 1000005061 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included
95 72.5kV and 36kV Equipment 1000005036 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included
96 72.5kV and 36kV Equipment 1000028100 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included
97 Structures-72.5 and 33kV Equipment 1000049660 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included
98 Structures-72.5 and 33kV Equipment 1000049661 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included
99 Structures-72.5 and 33kV Equipment 1000049658 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 6 Included
100 Structures-72.5 and 33kV Equipment 1000028542 STRUCTURE FOR-33KV H-TYPE POLE STRUCTURE EA 1 Included
101 Structures-72.5 and 33kV Equipment 1000049659 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included Bought-Out
102 PLCC Equipment-Nange 1000010014 Coupling device for PLCC SET 1 Included Bought-Out STP 9M SP 33
103 PLCC Equipment-Nange 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included
104 PLCC Equipment-Nange 1000017887 Analog Protection Coupler for PLCC EA 1 Included
105 PLCC Equipment-Nange 1000010638 Digital Protection Coupler EA 1 Included
106 PLCC Equipment-Nange 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included
107 PLCC Equipment-Nange 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 Included
108 PLCC Equipment-Nange 1000011082 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included
109 PLCC Equipment-Nange 1000004400 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
110 PLCC Equipment-Nange 1000004290 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included
111 PLCC Equipment-Nange 1000001104 2wire telephone equipment EA 2 Included
112 PLCC Equipment-Koldam 1000010014 Coupling device for PLCC SET 1 Included
113 PLCC Equipment-Koldam 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included
114 PLCC Equipment-Koldam 1000017887 Analog Protection Coupler for PLCC EA 1 Included
115 PLCC Equipment-Koldam 1000010638 Digital Protection Coupler EA 1 Included
116 DG SET 1000001893 250 kVA Diesel Generator along with control Panel SET 1 Included
117 Ventilation System 1000022408 Ventillation system for 400KV GIS Hall SET 1 Included
118 Ventilation System 1000022406 Ventillation system for 220KV GIS Hall SET 1 Included
119 Air Conditioning System 1000013502 High wall type split AC unit of 2 TR capacity EA 30 Included
120 Main Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 5 Included
121 Fire Protection System 1000012014 Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included
122 Fire Protection System 1000012010 Fire Detection and Alarm System for 400kV GIS Hall SET 1 Included
123 Fire Protection System 1000012009 Fire Detection and Alarm System for 220kV GIS Hall SET 1 Included
124 Fire Protection System 1000049665 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 2 Included
125 Fire Protection System 1000012024 Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 10 Included
126 Fire Protection System 1000012027 9litre water type Portable Fire extinguisher EA 10 Included
127 Fire Protection System 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 10 Included
128 Fire Protection System 1000012064 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 105 MVA ,400 kV, 1-phaseAutotransformer SET 7 Included
129 Fire Protection System 1000057271 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 41.67 MVAR, 420kV, 1 phaseReactor SET 4 Included
130 Fire Protection System 1000012031 Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included
131 Illumination System- Indoor 1000049467 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 Included
132 Illumination System- Indoor 1000049469 INDOOR LIGHTNING FOR DG SET & FIRE FIGHTING PUMP HOUSE SET 1 Included
133 Illumination System- Indoor 1000030151 Security Room Illumination including conduit LS 1 Included
134 Illumination System- Indoor 1000009647 Control room cum administrative building (400kV) illumination LOT 1 Included
135 Illumination System- Outdoor 1000017691 Post top Lantern tubular pole EA 10 Included
136 Illumination System- Outdoor 1000038388 POLE MOUNTED LED POST TOP LUMINAIRE TYPE SL-D1 (= 30W)AS PER TECHNICALSPECIFICATION EA 10 Included
137 Illumination System- Outdoor 1000001050 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 3 Included
138 Illumination System- Outdoor 1000025538 Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included
139 Illumination System- Outdoor 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included
140 Illumination System- Outdoor 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 4 Included
141 Illumination System- Outdoor 1000038397 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 30 Included
142 Illumination System- Outdoor 1000038042 LIGHTING FIXTURE LED LUMINAIRES TYPE SL-L1 AS PER TECH. SPECIFICATIONS EA 30 Included
143 Illumination System- Outdoor 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 15 Included
144 Illumination System- Outdoor 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 30 Included
145 Illumination System- Outdoor 1000014547 Lighting Panel type ACP-2 as per technical specification EA 8 Included
146 Gantry Structure 1000054362 LINE TAKEOFF GANTRY STRUCTURE FOR A 420 KV LINE IN GIS SUBSTATIONINCLUDING FOUNDATION BOLT, ALL TYPES OF NUT, BOLT, WASHERS ETC EA 2 Included
147 Visual Monitoring System 1000025861 Visual Monitoring System for Watch & Ward SET 1 Included
148 Mandatory spares AIS & General-LS 1000025943 Spare-420kV CVT 1 SET 1 Included
149 Mandatory spares AIS & General-LS 1000028266 Spares for 420kV Shunt Reactor LS 1 Included
150 Mandatory spares AIS & General-LS 1000026087 Spares for 120kV Surge Arrester LS 1 Included
151 Mandatory spares AIS & General-LS 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 Included
152 Mandatory spares AIS & General-LS 1000019912 Relay & protection Panels (with automation) LS 1 Included
153 Mandatory spares AIS & General-LS 1000019927 Spares-Substation Automation System LS 1 Included
154 Mandatory spares AIS & General-LS 1000025950 Spare-PLCC SET 1 Included
155 Mandatory spares AIS & General-LS 1000019925 Spares for Fire Protection System LS 1 Included
156 Mandatory spares AIS & General-LS 1000019915 Spares for DG set LS 1 Included
157 Mandatory spares AIS & General-LS 1000019913 Spares for 220V Batteries LS 1 Included
158 Mandatory spares AIS & General-LS 1000019920 Spares for 48V Batteries LS 1 Included
159 Mandatory spares AIS & General-LS 1000019914 Spares fpr 220V Battery Charger LS 1 Included
160 Mandatory spares AIS & General-LS 1000019921 Spares fpr 48V Battery Charger LS 1 Included
161 Mandatory spares AIS & General-LS 1000025940 Spare-420kV BPI SET 1 Included
162 Mandatory spares AIS & General-LS 1000025932 Spare-245kV BPI SET 1 Included
163 Mandatory spares AIS & General-LS 1000025930 Spare-216kV Surge Arrester SET 1 Included
164 Mandatory spares AIS & General-LS 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included
165 Mandatory spares AIS & General-LS 1000025980 Power and Control Cables LS 1 Included
166 Mandatory spares 400kV GIS 1000058332 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 Included
167 Mandatory spares 400kV GIS 1000049817 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 3 Included
168 Mandatory spares 400kV GIS 1000049753 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 2 Included
169 Mandatory spares 400kV GIS 1000049762 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 3 Included
170 Mandatory spares 400kV GIS 1000058330 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 Included
171 Mandatory spares 400kV GIS 1000049750 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 3 Included
172 Mandatory spares 400kV GIS 1000058331 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 Included
173 Mandatory spares 400kV GIS 1000049783 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 3 Included
174 Mandatory spares 400kV GIS 1000049505 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 5 Included
175 Mandatory spares 400kV GIS 1000058334 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included
176 Mandatory spares 400kV GIS 1000058329 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included
177 Mandatory spares 400kV GIS 1000058333 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 Included
178 Mandatory spares 400kV GIS 1000049498 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 2 Included
179 Mandatory spares 400kV GIS 1000058317 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 Included
180 Mandatory spares 400kV GIS 1000058316 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 Included
181 Mandatory spares 400kV GIS 1000021873 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 Included
182 Mandatory spares 400kV GIS 1000009208 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 Included
183 Mandatory spares 400kV GIS 1000058324 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 Included
184 Mandatory spares 400kV GIS 1000007067 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 3 Included
185 Mandatory spares 400kV GIS 1000058323 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 Included
186 Mandatory spares 400kV GIS 1000058320 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
187 Mandatory spares 400kV GIS 1000049759 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
188 Mandatory spares 400kV GIS 1000058319 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
189 Mandatory spares 400kV GIS 1000058322 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 Included
190 Mandatory spares 400kV GIS 1000049835 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
191 Mandatory spares 400kV GIS 1000049795 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
192 Mandatory spares 400kV GIS 1000049808 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
193 Mandatory spares 400kV GIS 1000049805 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
194 Mandatory spares 400kV GIS 1000058321 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
195 Mandatory spares 400kV GIS 1000049799 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
196 Mandatory spares 400kV GIS 1000058325 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 Included
197 Mandatory spares 400kV GIS 1000058318 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 Included
198 Mandatory spares 400kV GIS 1000049495 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 Included
199 Mandatory spares 400kV GIS 1000049802 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 Included
200 Mandatory spares 400kV GIS 1000058374 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 Included
201 Mandatory spares 400kV GIS 1000058314 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 Included Bought-Out
202 Mandatory spares 400kV GIS 1000058310 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 Included Bought-Out STP 9M SP 33
203 Mandatory spares 400kV GIS 1000058305 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 Included
204 Mandatory spares 400kV GIS 1000058312 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 Included
205 Mandatory spares 400kV GIS 1000058308 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH SET 1 Included
206 Mandatory spares 400kV GIS 1000049776 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 2 Included
207 Mandatory spares 400kV GIS 1000049778 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 2 Included
208 Mandatory spares 400kV GIS 1000049777 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS SET 2 Included
209 Mandatory spares 400kV GIS 1000058306 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 Included
210 Mandatory spares 400kV GIS 1000058313 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 Included
211 Mandatory spares 400kV GIS 1000058309 DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH SET 1 Included
212 Mandatory spares 400kV GIS 1000058307 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 Included
213 Mandatory spares 400kV GIS 1000058315 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 Included
214 Mandatory spares 400kV GIS 1000058311 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH EA 1 Included
215 Mandatory spares 400kV GIS 1000058327 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 Included
216 Mandatory spares 400kV GIS 1000058326 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 Included
217 Mandatory spares 400kV GIS 1000058328 400KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 Included
218 Mandatory spares 220kV GIS 1000058295 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 Included
219 Mandatory spares 220kV GIS 1000058300 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 Included
220 Mandatory spares 220kV GIS 1000049816 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 3 Included
221 Mandatory spares 220kV GIS 1000049752 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 2 Included
222 Mandatory spares 220kV GIS 1000049761 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 3 Included
223 Mandatory spares 220kV GIS 1000058298 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 Included
224 Mandatory spares 220kV GIS 1000049749 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 3 Included
225 Mandatory spares 220kV GIS 1000058299 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 Included
226 Mandatory spares 220kV GIS 1000049782 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 3 Included
227 Mandatory spares 220kV GIS 1000049504 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 5 Included
228 Mandatory spares 220kV GIS 1000058302 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included
229 Mandatory spares 220kV GIS 1000058297 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 Included
230 Mandatory spares 220kV GIS 1000058301 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 Included
231 Mandatory spares 220kV GIS 1000049497 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 2 Included
232 Mandatory spares 220kV GIS 1000058284 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included
233 Mandatory spares 220kV GIS 1000058286 220KV GIS-ONE POLE OF 2500A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included
234 Mandatory spares 220kV GIS 1000058285 220KV GIS-ONE POLE OF 3000A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 Included
235 Mandatory spares 220kV GIS 1000021871 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 Included
236 Mandatory spares 220kV GIS 1000009185 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 1 Included
237 Mandatory spares 220kV GIS 1000058292 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 Included
238 Mandatory spares 220kV GIS 1000007066 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 3 Included
239 Mandatory spares 220kV GIS 1000058291 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 Included
240 Mandatory spares 220kV GIS 1000058288 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
241 Mandatory spares 220kV GIS 1000049758 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
242 Mandatory spares 220kV GIS 1000058272 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
243 Mandatory spares 220kV GIS 1000058290 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 Included
244 Mandatory spares 220kV GIS 1000049834 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
245 Mandatory spares 220kV GIS 1000049794 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
246 Mandatory spares 220kV GIS 1000049807 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
247 Mandatory spares 220kV GIS 1000049804 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
248 Mandatory spares 220kV GIS 1000058289 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 Included
249 Mandatory spares 220kV GIS 1000049798 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
250 Mandatory spares 220kV GIS 1000058293 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 Included
251 Mandatory spares 220kV GIS 1000058287 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 Included
252 Mandatory spares 220kV GIS 1000049797 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 Included
253 Mandatory spares 220kV GIS 1000049801 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 Included
254 Mandatory spares 220kV GIS 1000058371 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 Included
255 Mandatory spares 220kV GIS 1000058372 220kV GIS- Three phase of 2500Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 Included
256 Mandatory spares 220kV GIS 1000058373 220kV GIS- Three phase of 3000Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 Included
257 Mandatory spares 220kV GIS 1000058282 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 Included
258 Mandatory spares 220kV GIS 1000058278 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 Included
259 Mandatory spares 220kV GIS 1000058273 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 Included
260 Mandatory spares 220kV GIS 1000058280 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 Included
261 Mandatory spares 220kV GIS 1000058276 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 Included
262 Mandatory spares 220kV GIS 1000049773 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 2 Included
263 Mandatory spares 220kV GIS 1000049775 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 2 Included
264 Mandatory spares 220kV GIS 1000049774 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 2 Included
265 Mandatory spares 220kV GIS 1000058274 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 Included
266 Mandatory spares 220kV GIS 1000058281 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 Included
267 Mandatory spares 220kV GIS 1000058277 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 Included
268 Mandatory spares 220kV GIS 1000058275 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 Included
269 Mandatory spares 220kV GIS 1000058283 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 Included
270 Mandatory spares 220kV GIS 1000058279 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 Included
271 Mandatory spares 220kV GIS 1000058294 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 Included
272 Mandatory spares 220kV GIS 1000058296 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 Included
273 Mandatory spares 220kV GIS 1000058303 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 Included
274 Mandatory spares 220kV GIS 1000058304 220KV GIS- SURGE COUNTER/ MONITOR EA 1 Included
275 Tower-Structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 14 Included
276 Tower-Structure 1000015953 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 17 Included
277 Tower-Structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2 Included
278 Tower-Structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 3 Included
279 PMU & associated items (Nange SS) 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 2 Included
280 PMU & associated items (Nange SS) 1000022512 WAMS Hardware - Time System (GPS receiver) EA 2 Included
281 PMU & associated items (Nange SS) 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included
282 PMU & associated items (Nange SS) 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
283 Tele Eqpt at Nange GIS 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
284 Tele Eqpt at Nange GIS 1000014273 L16.2 SFP EA 2 Included
285 Tele Eqpt at Nange GIS 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
286 Tele Eqpt at Nange GIS 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
287 Tele Eqpt at Nange GIS 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
288 Tele Eqpt at Nange GIS 1000026228 Equipment Cabinets For SDH EA 1 Included
289 Tele Eqpt at Nange GIS 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 1 Included
290 Tele Eqpt at Nange GIS 1000028265 Software for Craft Terminal EA 1 Included
291 Tele Eqpt at Nange GIS 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 4 Included
292 Tele Eqpt at Nange GIS 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included
293 Tele Eqpt at Nange GIS 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included
294 Spares-Tele Eqpt at Nange GIS 1000031369 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included
295 Spares-Tele Eqpt at Nange GIS 1000018706 S16.1 SFP EA 1 Included
296 Spares-Tele Eqpt at Nange GIS 1000014273 L16.2 SFP EA 1 Included
297 Spares-Tele Eqpt at Nange GIS 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included
298 Spares-Tele Eqpt at Nange GIS 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included
299 Spares-Tele Eqpt at Nange GIS 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
300 Spares-Tele Eqpt at Nange GIS 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included
301 Spares-Tele Eqpt at Nange GIS 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included Bought-Out
302 Spares-Tele Eqpt at Nange GIS 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included Bought-Out STP 9M SP 33
II 400kV Koldam Extn. Bought-Out
303 400kV Bus Reactor 1000057268 41.67MVAR, 420kV, 1-phase Reactor excluding Insulating Oil EA 4 Included
304 400kV Bus Reactor 1000057272 Insulating Oil for 41.67MVAR, 420kV 1-phase Reactor SET 4 Included
305 400kV AIS Equipment 1000004501 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 2 Included
306 400kV AIS Equipment 1000004463 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 6 Included
307 400kV AIS Equipment 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 3 Included
308 400kV AIS Equipment 1000004498 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 6 Included
309 400kV AIS Equipment 1000020419 336kV Surge Arrester (1-phase) EA 3 Included
310 400kV AIS Equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 16 Included
311 Erection Hardware 1000011301 Erection Hardware for 400kV D type layout-Line bay as per technicalspecification SET 1 Included
312 Erection Hardware 1000011298 Erection Hardware for 400kV D type layout-Bus Reactor bay as pertechnical specification SET 1 Included
313 400kV Insulator &Hardware 1000055991 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included
314 400kV Insulator &Hardware 1000055988 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH THROUGH CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included
315 400kV Insulator &Hardware 1000055986 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included
316 400kV Insulator &Hardware 1000055984 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 3 Included
317 Control & Relay Panels 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 Included
318 Control & Relay Panels 1000003398 400kV Line Protection Panel (with Automation) EA 1 Included
319 Control & Relay Panels 1000002146 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 Included
320 Control & Relay Panels 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 Included
321 Substation Automation 1000003409 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 Included
322 Substation Automation 1000003411 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 Included
323 PLCC Equipment 1000004290 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included
324 PLCC Equipment 1000004400 420 kV ,1 phase Bus Post Insulators for Line Traps EA 6 Included
325 Indoor Illumination system 1000013795 Illumination System for switchyard panel room of 6 m length LS 1 Included
326 Outdoor Illumination System 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 Included
327 Outdoor Illumination System 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 Included
328 Outdoor Illumination System 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 Included
329 Outdoor Illumination System 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 Included
330 FF system 1000012018 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 1 Included
331 FF system 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 4 Included
332 FF system 1000012026 6Kg dry chemical powered type Portable Fire extinguisher EA 2 Included
333 FF system 1000057271 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 41.67 MVAR, 420kV, 1 phaseReactor SET 4 Included
334 Air condition 1000006284 Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included
335 Power and Control Cables 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 1.2 Included
336 Power and Control Cables 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 3 Included
337 Power and Control Cables 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 4 Included
338 Power and Control Cables 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 1 Included
339 Power and Control Cables 1000056265 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 0.4 Included
340 Power and Control Cables 1000031953 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1.6 Included
341 Power and Control Cables 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 1 Included
342 Power and Control Cables 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 1 Included
343 Power and Control Cables 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 6.5 Included
344 Power and Control Cables 1000031951 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included
345 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 Included
346 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included
347 Equipment Structure 1000049653 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CT (1PH) EA 6 Included
348 Equipment Structure 1000049654 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CVT (1PH) EA 3 Included
349 Equipment Structure 1000049655 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 3 Included
350 Equipment Structure 1000049657 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 7 Included
351 Equipment Structure 1000049652 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 16 Included
352 Equipment Structure 1000049656 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV WAVE TRAP (1PH) EA 2 Included
353 Gantry Structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 9 Included
354 Gantry Structure 1000015953 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 11 Included
355 Gantry Structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included
356 Gantry Structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included
357 Mandatory Spares 1000019918 Spares for 420kV Circuit Breaker LS 1 Included
358 Mandatory Spares 1000019919 Spares for 420kV Double break Isolator LS 1 Included
359 Mandatory Spares 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 Included
360 Mandatory Spares 1000025943 Spare-420kV CVT 1 SET 1 Included
361 Mandatory Spares 1000025941 Spare-420kV CT 1 SET 1 Included
362 Mandatory Spares 1000019912 Relay & protection Panels (with automation) LS 1 Included
363 Mandatory Spares 1000019927 Spares-Substation Automation System LS 1 Included
364 Mandatory Spares 1000025950 Spare-PLCC SET 1 Included
365 Mandatory Spares 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 Included
366 Mandatory Spares 1000028245 Spare For 400kV Bus Reactor LS 1 Included
367 PMU & associated items (Koldam SS) 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 1 Included
368 PMU & associated items (Koldam SS) 1000022512 WAMS Hardware - Time System (GPS receiver) EA 1 Included
369 PMU & associated items (Koldam SS) 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 2 Included
370 PMU & associated items (Koldam SS) 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
371 Tele Eqpt at Koldam 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
372 Tele Eqpt at Koldam 1000018706 S16.1 SFP EA 4 Included
373 Tele Eqpt at Koldam 1000014273 L16.2 SFP EA 2 Included
374 Tele Eqpt at Koldam 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
375 Tele Eqpt at Koldam 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
376 Tele Eqpt at Koldam 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
377 Tele Eqpt at Koldam 1000026228 Equipment Cabinets For SDH EA 1 Included
378 Tele Eqpt at Koldam 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 Included
379 Tele Eqpt at Koldam 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included
380 Tele Eqpt at Koldam 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included
III Switchable Line Rector at Ropar Bought-Out
381 50 MVAR Line Reactor 1000004900 50 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 1 Included
382 50 MVAR Line Reactor 1000014013 Insulating Oil for 50 MVAR,420kV ,3-phase Shunt Reactor SET 1 Included
383 50 MVAR Line Reactor 1000015913 Oil filled Neutral Grounding Reactor (NGR) along with supportstructure & terminal connector EA 1 Included
384 AIS Equipment 1000004501 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 1 Included
385 AIS Equipment 1000004498 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 1 Included
386 AIS Equipment 1000020419 336kV Surge Arrester (1-phase) EA 3 Included
387 AIS Equipment 1000020416 120kV Surge Arrester(1-phase) EA 1 Included
388 AIS Equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 3 Included
389 Erection Hardware 1000011321 Erection Hardware for 400kV I type layout-Line Reactor including NGRbypass arrangement as per technical specification SET 1 Included
390 400kV Insulator &Hardware 1000055986 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGSWITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included
391 Control & Relay Panels 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 Included
392 Control & Relay Panels 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 Included
393 Control & Relay Panels 1000009713 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 Included
394 Substation Automation 1000003413 Complete Substation automation System for 400kV Switchable LineReactor Bay as per Technical Specification EA 1 Included
395 Outdoor Illumination System 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 Included
396 Outdoor Illumination System 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 2 Included
397 Outdoor Illumination System 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 Included
398 Outdoor Illumination System 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 Included
399 FF system 1000012045 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 50 MVAR, 420kV, 3 phaseshunt Reactor SET 1 Included
400 Power and Control Cables 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 Included
401 Power and Control Cables 1000056264 1.1KV GRADE 19CX1.5 SQMM CONTROL CABLE KM 0.5 Included
402 Power and Control Cables 1000056265 1.1KV GRADE 27CX1.5 SQMM CONTROL CABLE KM 0.4 Included
403 Power and Control Cables 1000031953 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 0.8 Included
404 Power and Control Cables 1000031943 1.1KV GRADE 2CX6 SQMM (PVC) POWER CABLE KM 0.5 Included
405 Power and Control Cables 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.5 Included
406 Power and Control Cables 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 Included
407 Power and Control Cables 1000031951 1.1KV GRADE 3.5CX300 SQMM (XLPE) POWER CABLE KM 0.5 Included
408 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 Included
409 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 Included
410 Equipment Structure 1000049655 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV CLASS SA (1PH) EA 3 Included
411 Equipment Structure 1000049657 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV ISOLATOR (3PH) EA 1 Included
412 Equipment Structure 1000049652 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-400KV BPI (1PH) EA 3 Included
Note : The Price quoted against Supply, F&I & Erection & commissioning for BPL Service connection Including taxes and duties shall be limited to Rs 3000/- per service connection
Date -- Printed Name:
Place Designation :
Spec.No. Schedule - 2 Dis
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
#REF! Total Discount #REF!
Address : #REF!
#REF! Multipackage Discount #REF!
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
(a) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c ) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF!
(e) #REF! #REF! #REF! #REF! #REF!
(f) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF!
(e) #REF! #REF! #REF! #REF! #REF!
(f) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF!
(e) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(i) #REF! #REF! #REF! #REF! #REF!
(ii) #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : #REF! Printed Name : #REF!
Designation : #REF!
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 3
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage lum-sum #REF!
Gurgaon (Haryana) - 122001
INSTALLATION CHARGES
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. PR No. PR Line Item No. Activity Header PR Activity No. Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
I 400/200kV Nange GIS Revaluation of J column Tax Calculation
1 515 30 INST-420 kV,125 MVAR BUS REACTOR 100018035 998736 18 41.67 MVAR, 420KV, 1-PHASE BUS REACTOR EXCLUDING INSULATING OIL EA 4 Included 0 0 0
2 515 40 INST-420 kV,125 MVAR BUS REACTOR 100018036 998736 18 INSULATING OIL FOR 41.67 MVAR, 420KV 1-PHASE BUS REACTOR SET 4 Included 0 0 0
3 520 10 INST-LT transformer 100000078 998736 18 630kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0 0 0
4 530 50 INST-AIS equipment 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 27 Included 0 0 0
5 530 40 INST-AIS equipment 100000484 998736 18 216kV Surge Arrester (1-phase) EA 7 Included 0 0 0
6 530 30 INST-AIS equipment 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 32 Included 0 0 0
7 530 20 INST-AIS equipment 100000328 998736 18 336kV Surge Arrester (1-phase) EA 17 Included 0 0 0
8 530 10 INST-AIS equipment 100000275 998736 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0 0 0
9 530 60 INST-AIS equipment 100000011 998736 18 Current transformer (33kV) for transformer Netural along with support structure & terminal connector SET 2 Included 0 0 0
10 540 100 INST-GIS equipment 100000268 998736 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 2 Included 0 0 0
11 540 50 INST-GIS equipment 100002099 998736 18 420 kV, 3150 A, 63 kA, SF6 GIS Line feeder bay module(without PIR) as per Section-Project, Technical specification SET 1 Included 0 0 0
12 540 40 INST-GIS equipment 100001832 998736 18 420 kV, 3150 A, 63 kA, SF6 GIS Line feeder bay module(with PIR) as per Section-Project, Technical specification SET 2 Included 0 0 0
13 540 70 INST-GIS equipment 100002132 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Tie bay module(without PIR) as per Section-Project, Technical specification SET 1 Included 0 0 0
14 540 60 INST-GIS equipment 100001843 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Tie bay module(with PIR) as per Section-Project, Technical specification SET 2 Included 0 0 0
15 540 30 INST-GIS equipment 100000234 998736 18 420kV, 4000 A, 63 kA, 3-phase SF6 GIS bus bar SET 2 Included 0 0 0
16 540 20 INST-GIS equipment 100002140 998736 18 420kV, 3000A/3150, 63kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outsideGIS Hall along with associated support structure M 500 Included 0 0 0
17 540 10 INST-GIS equipment 100002392 998736 18 420kV, SF6 to Air Bushing alongwithassociated support structure for 3150A,63 kA for 1 sec. Single Phase EA 17 Included 0 0 0
18 540 80 INST-GIS equipment 100001826 998736 18 420kV, 3150 A, 63 kA, SF6 GIS ICT feeder bay module as per Section-Project, Technical specification SET 2 Included 0 0 0
19 540 90 INST-GIS equipment 100001840 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Bus Reactor bay module as per Section-Project, Technical specification SET 1 Included 0 0 0
20 540 110 INST-GIS equipment 100000367 998736 18 245kV, 1600 A, 50 kA, SF6 GIS ICT feeder bay module SET 2 Included 0 0 0
21 540 120 INST-GIS equipment 100000409 998736 18 245kV, 2500 A, 50 kA, SF6 GIS Bus coupler bay module SET 1 Included 0 0 0
22 540 130 INST-GIS equipment 100000401 998736 18 245 kV, 4000A, 50kA, 3 single phase(isolated), SF6 gas insulated, metalenclosed bus bars to interconnect eachof Circuit Breaker bay module completewith voltage transformer, disconnectorswith grounding switch, local controlcubicle, SF6 gas monitoring system forthe complete bus SET 2 Included 0 0 0
23 540 140 INST-GIS equipment 100002153 998736 18 245kV,1600A, 50kA,3 Single phase/3Phase, SF6 Gas Insulated Bus Duct(GIB) outside GIS Hall alongwithassociated support structure(Quantitymentioned here is for 3 Phase type) M 250 Included 0 0 0
24 540 150 INST-GIS equipment 100002390 998736 18 245kV,1600A, 50 kA for 1 sec SF6 to Air Bushing EA 7 Included 0 0 0
25 540 160 INST-GIS equipment 100002105 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Auxiliary Bus module for Spare Transformer as per Section-Project, Technical specification SET 1 Included 0 0 0
26 540 170 INST-GIS equipment 100002111 998736 18 420kV, 3150 A, 50 kA, SF6 GIS Auxiliary Bus module for Spare Bus Reactor as per Section-Project, Technical specification SET 1 Included 0 0 0
27 550 10 INST-GIS testing & Maintenance equipment 100000259 998736 18 EOT Crane for GIS Building for 400kV GIS station SET 1 Included 0 0 0
28 550 20 INST-GIS testing & Maintenance equipment 100000433 998736 18 EOT Crane for GIS Building for 220kV GIS Station SET 1 Included 0 0 0
29 560 10 INST-Control & Protection 100000732 998736 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0 0 0
30 560 60 INST-Control & Protection 100000741 998736 18 220kV Bus Bar Protection Panel (Single)-(with Automation) SET 1 Included 0 0 0
31 560 40 INST-Control & Protection 100000733 998736 18 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0 0 0
32 560 30 INST-Control & Protection 100000731 998736 18 400kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 2 Included 0 0 0
33 560 20 INST-Control & Protection 100000730 998736 18 400kV Line Protection Panel (with Automation) EA 2 Included 0 0 0
34 560 50 INST-Control & Protection 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 9 Included 0 0 0
35 560 70 INST-Control & Protection 100016778 998736 18 220kV Circuit Breaker Relay Panel (with Automation) EA 3 Included 0 0 0
36 560 230 INST-Control & Protection 100001891 998736 18 Time synchronisation equipment EA 1 Included 0 0 0
37 570 50 INST-SAS 100000783 998736 18 Complete Substation automation System for controlling and monitoring of Auxilary System including BCUs as per technicalspecification SET 1 Included 0 0 0
38 570 30 INST-SAS 100000772 998736 18 Complete Substation automation System for 220kV bay as per Technical Specification EA 3 Included 0 0 0
39 570 20 INST-SAS 100000777 998736 18 Complete Substation automation System for 400kV Tie bay as per Technical Specification EA 3 Included 0 0 0
40 570 10 INST-SAS 100000771 998736 18 Complete Substation automation System for 400kV Main bay as per Technical Specification EA 6 Included 0 0 0
41 580 10 INST-Power & Control Cable 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
42 580 20 INST-Power & Control Cable 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
43 580 30 INST-Power & Control Cable 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
44 585 10 Insta. Hardware fittings 100017133 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0 0 0
45 585 20 Insta. Hardware fittings 100017126 998731 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0 0 0
46 590 30 INST-Erection hardware 100002036 998731 18 Erection Hardware for the 72.5kV equipment for Tertiary loading as per technical specification SET 1 Included 0 0 0
47 590 10 INST-Erection hardware 100002037 998731 18 Erection Hardware for the 33kV equipment for SEB supply as per technical specification SET 1 Included 0 0 0
48 590 20 INST-Erection hardware 100003610 998736 18 Conductor, clamps,connector including eqpt connectors earthing material, risers etc required for connection of aux. LT transformer. SET 1 Included 0 0 0
49 590 40 INST-Erection hardware 100000513 998731 18 Erection Hardware for 220kV DM-type layout for GIS termination arrangement-Transformer bay as per specification SET 2 Included 0 0 0
50 590 50 INST-Erection hardware 100000331 998731 18 Erection Hardware for 400kV I type layout-Bus Reactor bay as per specification as per specification SET 1 Included 0 0 0
51 590 60 INST-Erection hardware 100002187 998731 18 Erection Hardware for 400kV I type layout for GIS termination arrangement-Line bay as per technical specification SET 2 Included 0 0 0
52 590 70 INST-Erection hardware 100002188 998731 18 Erection Hardware for 400kV I type layout for GIS termination arrangement-Transformer bay as per technical specification SET 2 Included 0 0 0
53 590 80 INST-Erection hardware 100018039 998731 18 BUS POST INSULATORS, SPACERS, EQUIPMENT SUPPORT STRUCTURES INCLUDING FOUNDATION BOLTS,CONDUCTOR(S), AL TUBE, CLAMP, CONNECTORSINCLUDING 420 KV AND NEUTRAL BUSHINGS TERMINAL CONNECTORS ETC FOR NEUTRAL FORMATION FOR ONE (1) REACTOR BANKS (EACH BANK COMPRISE OFTHREE SINGLE PHASE UNITS OF REACTORS) AND CONNECTION TO NEUTRAL GROUNDING REACTORS (AS APPLICABLE) AND MAKING CONNECTION ARRANGEMENTTO CONNECT SPARE UNIT IN PLACE OF ANY UNIT OF ALL THE BANKS WITHOUT PYSICAL SHIFTING LS 1 Included 0 0 0
54 590 90 INST-Erection hardware 100003892 998731 18 Bus post insulators, spacers, equipment support structures, conductors, Al tube, clamp, connectors (including 400kV, 220kV,tertiary and neutural bushing terminal connectors etc) for arrangement of netural formation for Transformer(s), DELTA formation forone bank (each bank comprises of 3 single phase units of Autotransformers) and making connection arrangement to connect spare unitin place of any unit of the bank without physical shifting LOT 2 Included 0 0 0
55 600 70 INST-Structure 100008230 995455 18 Equipment Structure including Foundation bolt-220kV BPI (1Ph) EA 27 Included 0 0 0
56 600 80 INST-Structure 100008228 995455 18 Equipment Structure including Foundation bolt-220kV class SA (1Ph) EA 7 Included 0 0 0
57 600 40 INST-Structure 100008224 995455 18 Equipment Structure including Foundation bolt-400kV Wave Trap (1Ph) EA 4 Included 0 0 0
58 600 30 INST-Structure 100008223 995455 18 Equipment Structure including Foundation bolt-400kV BPI (1Ph) EA 32 Included 0 0 0
59 600 20 INST-Structure 100008222 995455 18 Equipment Structure including Foundation bolt-400kV class SA (1Ph) EA 17 Included 0 0 0
60 600 10 INST-Structure 100008220 995455 18 Equipment Structure including Foundation bolt-400kV CVT (1Ph) EA 6 Included 0 0 0
61 620 10 INST-LT switchgear 100000894 998736 18 415V Main Switchboard SET 1 Included 0 0 0
62 620 20 INST-LT switchgear 100000895 998736 18 AC Distribution Board (ACDB) SET 1 Included 0 0 0
63 620 30 INST-LT switchgear 100002064 998731 18 415V MLDB(along with 2 nos. 100 kVA Lighting transformer) SET 1 Included 0 0 0
64 620 40 INST-LT switchgear 100000899 998736 18 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0 0 0
65 620 50 INST-LT switchgear 100000905 998736 18 48V DCDB SET 2 Included 0 0 0
66 620 60 INST-LT switchgear 100000902 998736 18 220V DCDB SET 2 Included 0 0 0
67 625 10 INST-Battery and Battrey charger 100000952 998736 18 48V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included 0 0 0
68 625 30 INST-Battery and Battrey charger 100000937 998736 18 220V, 100A/100A Float Cum Boost BatteryCharger EA 2 Included 0 0 0
69 625 50 INST-Battery and Battrey charger 100007271 998734 18 48 V VRLA Battery Bank SET 2 Included 0 0 0
70 625 60 INST-Battery and Battrey charger 100016318 998736 18 220V Battery set SET 2 Included 0 0 0
71 630 40 INST-72.5kV and 36kV Equipment 100001935 998736 18 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0 0 0
72 630 50 INST-72.5kV and 36kV Equipment 100000684 998736 18 36kV, 1ph Bus post insulator SET 3 Included 0 0 0
73 630 60 INST-72.5kV and 36kV Equipment 100000669 998736 18 30kV Surge Arrester (1-Phase) EA 3 Included 0 0 0
74 630 70 INST-72.5kV and 36kV Equipment 100000626 998736 18 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0 0 0
75 630 80 INST-72.5kV and 36kV Equipment 100001909 998736 18 72.5kV, Bus Post Insulator, 1-Phase EA 6 Included 0 0 0
76 630 90 INST-72.5kV and 36kV Equipment 100000624 998736 18 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0 0 0
77 630 100 INST-72.5kV and 36kV Equipment 100000623 998736 18 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0 0 0
78 630 110 INST-72.5kV and 36kV Equipment 100000611 998736 18 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0 0 0
79 630 120 INST-72.5kV and 36kV Equipment 100000701 998736 18 36 kV, 3-phase Horn Gap Fuse EA 1 Included 0 0 0
80 635 10 INST-Structures-72.5 and 33kV Equipment 100008231 995455 18 Equipment Structure including Foundation bolt-72.5kV CT(1Ph) EA 3 Included 0 0 0
81 635 20 INST-Structures-72.5 and 33kV Equipment 100008232 995455 18 Equipment Structure including Foundation bolt-72.5kV PT (1Ph) EA 3 Included 0 0 0
82 635 30 INST-Structures-72.5 and 33kV Equipment 100008233 995455 18 Equipment Structure including Foundation bolt-72.5kV Isolator (3Ph) EA 1 Included 0 0 0
83 635 40 INST-Structures-72.5 and 33kV Equipment 100008234 995455 18 Equipment Structure including Foundation bolt-72.5kV BPI (1Ph) EA 6 Included 0 0 0
84 635 50 INST-Structures-72.5 and 33kV Equipment 100001672 995455 18 Erection of 33kV ouble Pole Structure including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 Included 0 0 0
85 640 10 INST- PLCC Equipment-Nange 100002042 998734 18 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0 0 0
86 640 20 INST- PLCC Equipment-Nange 100000883 998734 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0 0 0
87 640 30 INST- PLCC Equipment-Nange 100000886 998734 18 Coupling device for PLCC EA 1 Included 0 0 0
88 640 40 INST- PLCC Equipment-Nange 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0 0 0
89 640 50 INST- PLCC Equipment-Nange 100000890 998734 18 Protection Coupler (Analog) EA 1 Included 0 0 0
90 640 60 INST- PLCC Equipment-Nange 100000891 998734 18 Digital Protection Coupler EA 1 Included 0 0 0
91 640 70 INST- PLCC Equipment-Nange 100000892 998734 18 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0 0 0
92 640 90 INST- PLCC Equipment-Nange 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 Included 0 0 0
93 640 100 INST- PLCC Equipment-Nange 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 2 Included 0 0 0
94 670 20 INST-PLCC Equipment-Koldam 100000891 998734 18 Digital Protection Coupler EA 1 Included 0 0 0
95 670 30 INST-PLCC Equipment-Koldam 100000890 998734 18 Protection Coupler (Analog) EA 1 Included 0 0 0
96 670 40 INST-PLCC Equipment-Koldam 100000886 998734 18 Coupling device for PLCC EA 1 Included 0 0 0
97 670 50 INST-PLCC Equipment-Koldam 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0 0 0
98 680 10 Shifting of PLCC 100001492 995429 18 Dismantling, transportation & re-erection of 400kV PLCC SET 1 Included 0 0 0
99 730 10 INST-DG SET 100000957 998736 18 250 kVA Diesel Generator along with control Panel SET 1 Included 0 0 0
100 760 10 INST-Ventilation System 100001874 995463 18 Ventillation system for 400KV GIS Hall SET 1 Included 0 0 0
101 760 20 INST-Ventilation System 100001875 995463 18 Ventillation system for 220KV GIS Hall SET 1 Included 0 0 0
102 770 10 INST-Air Conditioning System 100000960 995463 18 High wall type split AC unit of 2 TR capacity EA 30 Included 0 0 0
103 790 10 INST-Main Earthmat 100003103 998731 18 40 mm MS rod for Main Earthmat KM 5 Included 0 0 0
104 795 70 INST-Fire Protection System 100000975 995461 18 4.5 kg CO2 type Portable Fire extinguisher EA 10 Included 0 0 0
105 795 60 INST-Fire Protection System 100000972 998736 18 9litre water type Portable Fire extinguisher EA 10 Included 0 0 0
106 795 50 INST-Fire Protection System 100002752 998736 18 5Kg dry chemical powered type Portable Fire extinguisher EA 10 Included 0 0 0
107 795 40 INST-Fire Protection System 100008260 998736 18 60 litre foam type Trolley/Wheel mounted Fire extinguisher EA 2 Included 0 0 0
108 795 30 INST-Fire Protection System 100002060 995461 18 Fire Detection and Alarm System for 220kV GIS Hall SET 1 Included 0 0 0
109 795 20 INST-Fire Protection System 100002059 995461 18 Fire Detection and Alarm System for 400kV GIS Hall SET 1 Included 0 0 0
110 795 10 INST-Fire Protection System 100002056 995461 18 Fire Detection and Alarm System for Control Room Building(400kV) SET 1 Included 0 0 0
111 795 150 INST-Fire Protection System 100000967 998736 18 Pumping arrangement for HVW system & hydrant system, complete with all piping, valves, fittings,etc. inside pump house for FireProtection System of 400/220kV (New) Substation SET 1 Included 0 0 0
112 795 160 INST-Fire Protection System 100000987 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 105 MVA ,(400/v3)/(220/v3)/33 kV, 1-phase Autotransformer SET 7 Included 0 0 0
113 795 170 INST-Fire Protection System 100018037 998736 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING AND ACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 41.67 MVAR, 420KV, 1PHASE BUS REACTOR SET 4 Included 0 0 0
114 795 180 INST-Fire Protection System 100000970 998736 18 Hydrant system, complete piping andaccessories etc. outside the Pump Housefor Fire Protection of 400/220kV (New)Substation SET 1 Included 0 0 0
115 830 30 INST-Illumination system- Indoor 100001887 998739 18 Control room cum administrative building (400kV) illumination. LOT 1 Included 0 0 0
116 830 40 INST-Illumination system- Indoor 100002487 998731 18 Security Room Illumination including conduit LS 1 Included 0 0 0
117 830 20 INST-Illumination system- Indoor 100008184 998736 18 Indoor Lightning for DG set & Fire Fighting Pump House SET 1 Included 0 0 0
118 830 10 INST-Illumination system- Indoor 100008185 998736 18 Indoor Lightning for GIS Building (As per Technical specification) including AHU & Relay Rooms as applicable SET 1 Included 0 0 0
119 840 20 INST-Illumination system-Outdoor 100004933 998731 18 Pole Mounted LED Post Top Luminaire TYPE SL-D1 (= 30W)as per technical specification EA 10 Included 0 0 0
120 840 10 INST-Illumination system-Outdoor 100001110 998731 18 Post top Lantern tubular pole EA 10 Included 0 0 0
121 840 30 INST-Illumination system-Outdoor 100001051 998731 18 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as per technical specifications EA 3 Included 0 0 0
122 840 40 INST-Illumination system-Outdoor 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 4 Included 0 0 0
123 840 50 INST-Illumination system-Outdoor 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included 0 0 0
124 840 60 INST-Illumination system-Outdoor 100004934 998731 18 Type L1 Street Lighting Pole of 6 meter as per technical specification. EA 30 Included 0 0 0
125 840 70 INST-Illumination system-Outdoor 100004850 998731 18 Lighting Fixture LED Luminaires type SL-L1 as per tech. specifications EA 30 Included 0 0 0
126 840 80 INST-Illumination system-Outdoor 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 15 Included 0 0 0
127 840 90 INST-Illumination system-Outdoor 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 30 Included 0 0 0
128 840 100 INST-Illumination system-Outdoor 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 8 Included 0 0 0
129 860 10 INST-Gantry Structure 100015758 995455 18 Line takeoff gantry structure for a 420 kV line in GIS substation including foundation bolt, all types of nut, bolt, washers etc EA 2 Included 0 0 0
130 870 10 INST-visual monitoring system 100000869 998736 18 Visual monitoring system for watch & ward SET 1 Included 0 0 0
131 890 10 INST-Tower Structure 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 14 Included 0 0 0
132 890 20 INST-Tower Structure 100001209 995455 18 Erection of Lattice Structures (HT Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts. MT 17 Included 0 0 0
133 890 30 INST-Tower Structure 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 2 Included 0 0 0
134 890 40 INST-Tower Structure 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 3 Included 0 0 0
135 900 10 Dismantling & Re-erection 100001520 995429 18 Dismantling & re-erection of 400kV CVT EA 3 Included 0 0 0
136 900 20 Dismantling & Re-erection 100001522 995429 18 Dismantling & re-erection of 400kV SA EA 3 Included 0 0 0
137 900 30 Dismantling & Re-erection 100001521 995429 18 Dismantling & re-erection of 400kV Isolators EA 1 Included 0 0 0
138 900 40 Dismantling & Re-erection 100001493 995429 18 Dismantling, transportation & re-erection of 400kV BPI EA 3 Included 0 0 0
139 20 10 PMU & associated items (Nange SS) 170000502 998713 18 Service:- Phasor Measurement Unit (PMU) EA 2 Included 0 0 0
140 20 20 PMU & associated items (Nange SS) 170000530 998734 18 WAMS TIME SYSTEM(GPS RECEIVER) EA 2 Included 0 0 0
141 20 30 PMU & associated items (Nange SS) 170000503 998713 18 Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 3 Included 0 0 0
142 20 40 PMU & associated items (Nange SS) 170000504 998713 18 Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0 0 0
143 20 50 PMU & associated items (Nange SS) 170000501 998734 18 Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0 0 0
144 40 10 Ser- Tele Eqpt at Nange GIS 100002812 998734 18 SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0 0 0
145 40 30 Ser- Tele Eqpt at Nange GIS 170000435 998734 18 Optical Interface Cards/SFP# -L16.2 for SDH Equipment-STM-16 EA 2 Included 0 0 0
146 40 40 Ser- Tele Eqpt at Nange GIS 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0 0 0
147 40 50 Ser- Tele Eqpt at Nange GIS 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0 0 0
148 40 60 Ser- Tele Eqpt at Nange GIS 100002829 998734 18 Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0 0 0
149 40 70 Ser- Tele Eqpt at Nange GIS 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 Included 0 0 0
150 40 80 Ser- Tele Eqpt at Nange GIS 170000376 998734 18 NMS-Craft Terminal-Hardware EA 1 Included 0 0 0
151 40 90 Ser- Tele Eqpt at Nange GIS 170000377 998734 18 NMS-Craft Terminal-Software EA 1 Included 0 0 0
152 40 100 Ser- Tele Eqpt at Nange GIS 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 4 Included 0 0 0
153 40 110 Ser- Tele Eqpt at Nange GIS 100002882 998336 18 Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1 Included 0 0 0
154 40 120 Ser- Tele Eqpt at Nange GIS 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 Included 0 0 0
155 10 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 16378 Included 0 0 0
156 10 20 Civil Works 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 4095 Included 0 0 0
157 10 30 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 849 Included 0 0 0
158 10 40 Civil Works 100017393 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:3:6) M3 16 Included 0 0 0
159 10 50 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 57 Included 0 0 0
160 10 60 Civil Works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 6637 Included 0 0 0
161 10 70 Civil Works 100001329 995454 18 Steel Reinforcement MT 477 Included 0 0 0
162 10 80 Civil Works 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 200 Included 0 0 0
163 10 90 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 197 Included 0 0 0
164 10 100 Civil Works 100004748 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) including a layer of cement slurry of mix1:6 (1 cement : 6 fine sand) shall be laid uniformly over cement concrete layer. The cement consumption for cement slurry shall notbe less than 150 kg per 100 sq.m. M3 720 Included 0 0 0
165 10 110 Civil Works 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 9600 Included 0 0 0
166 10 120 Civil Works 100001713 995424 18 Antiweed treatment M2 9600 Included 0 0 0
167 10 130 Civil Works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 2160 Included 0 0 0
168 10 140 Civil Works 100008110 995421 18 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 1875 Included 0 0 0
169 10 150 Civil Works 100001457 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails for auto transformer. M2 603 Included 0 0 0
170 10 160 Civil Works 100001458 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 252 Included 0 0 0
171 10 170 Civil Works 100008611 995477 18 Swtichyard fencing: Providing and fixing fencing of GI barbed wire consisting of galvanized MS tubular posts at 3 m intervals; GIbarded wire shall run horizontally from post to post at a spacing of 300 mm (vertically) and a cross formation in each panel,complete as per technical specification and drawing. M 100 Included 0 0 0
172 10 180 Civil Works 100001392 995455 18 Switchyard Gate excluding Concrete EA 1 Included 0 0 0
173 10 190 Civil Works 130000761 995428 18 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 110 Included 0 0 0
174 10 200 Civil Works 130000762 995428 18 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 431 Included 0 0 0
175 10 210 Civil Works 100020960 995461 18 RCC culvert crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as per specification. M 20 Included 0 0 0
176 10 220 Civil Works 100020961 995461 18 RCC culvert crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as per specification. M 20 Included 0 0 0
177 10 230 Civil Works 100020962 995461 18 RCC culvert crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as per specification. M 20 Included 0 0 0
178 10 240 Civil Works 100001409 995462 18 Supplying and erecting dewatering pumps-5 HP EA 3 Included 0 0 0
179 10 250 Civil Works 100007701 995462 18 Supplying and erecting dewatering pumps- 2 HP EA 1 Included 0 0 0
180 10 260 Civil Works 100015791 995454 18 All civil works for Drains construction of Section A-A including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 400 Included 0 0 0
181 10 270 Civil Works 100015792 995454 18 All civil works for Drains construction of Section B-B including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 300 Included 0 0 0
182 10 280 Civil Works 100015793 995454 18 All civil works for Drains construction of Section C-C including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 200 Included 0 0 0
183 10 290 Civil Works 100015794 995454 18 All civil works for Drains construction of Section D-D including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 100 Included 0 0 0
184 10 300 Civil Works 100003477 995454 18 Rain water harvesting excluding reinforcement and concrete as per drawing EA 1 Included 0 0 0
185 10 310 Civil Works 100001683 995414 18 Control Room Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 300 Included 0 0 0
186 10 320 Civil Works 100001682 995416 18 FFPH Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork,finishing (externaland internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paid separately as per BPS M2 101 Included 0 0 0
187 10 330 Civil Works 100001700 995454 18 All civil works as per drawing and specification but excluding excavation, PCC, RCC, reinforcement but including finishing (internaland external) etc & all civil works complete in all respect - Water Tank for Fire Fighting Pump House EA 1 Included 0 0 0
188 10 340 Civil Works 100008638 995421 18 Supplying and laying CPVC pipe for external water supply system - 75 mm dia pipe M 200 Included 0 0 0
189 10 350 Civil Works 100008639 995421 18 Supplying and laying CPVC pipe for external water supply system - 50 mm dia pipe M 150 Included 0 0 0
190 10 360 Civil Works 100010100 995421 18 Supplying and laying CPVC pipe for external water supply system - 40 mm dia pipe M 150 Included 0 0 0
191 10 370 Civil Works 100010101 995421 18 Supplying and laying CPVC pipe for external water supply system - 25 mm dia pipe M 150 Included 0 0 0
192 10 380 Civil Works 100001740 995441 18 Septic tank and soakpit for CRB EA 1 Included 0 0 0
193 10 390 Civil Works 100001755 995424 18 Providing & Laying of SW pipes for external sewerage system as per technical specification 100mm dia pipe M 100 Included 0 0 0
194 10 400 Civil Works 100001756 995424 18 Providing & Laying of SW pipes for external sewerage system as per technical specification 150mm dia pipe M 100 Included 0 0 0
195 10 410 Civil Works 100001757 995424 18 Providing & Laying of SW pipes for external sewerage system as per technical specification 200mm dia pipe M 80 Included 0 0 0
196 10 420 Civil Works 100001433 995435 18 Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0 0 0
197 10 430 Civil Works 100002587 995411 18 Providing & Erecting security/watchman room as per drawing, including excavation, PCC, RCC, Services, etc. complete in all respectsas per drawing. M2 18 Included 0 0 0
198 10 440 Civil Works 100002488 995462 18 Septic tank and soakpit for Security Room EA 1 Included 0 0 0
199 10 450 Civil Works 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 16000 Included 0 0 0
200 10 460 Civil Works 100002583 995432 18 Supply of earth (excluding rock & boulders) at site including royalty, carriage and filling in specified areas in layers notexceeding 200mm in depth, compacting under optimum moisture condition to achieve 95% of Proctor density, finishing etc. allcomplete, for all leads & lifts, with all labour, material, tools, tackles, equipments, safeguards & incidentals as necessary as perdrawings, specification and direction of the Engineer- in- Charge. M3 4000 Included 0 0 0
201 10 470 Civil Works 100002914 995432 18 Earthwork in excavation in Hard rocks in open areas/nallas/ channels, to the required slopes, shapes, levels, elevations andprofile, including trimming of bottom and slopes of excavation and stacking and disposal of rock for a lead up to 2.0 KM beyondleveling boundary and all lifts , with all labour, material, tools, tackles and equipment, safeguards and incidentals,Royalty,taxesetc. as per directions of the Engineer-in-Charge. Serviceable material if available shall be stacked at site as identified byEngineer-in-Charge.(50% void deduction from stack measurement) M3 500 Included 0 0 0
202 10 480 Civil Works 100002361 995455 18 Main Gate EA 1 Included 0 0 0
203 10 490 Civil Works 100008612 995477 18 Providing & Erecting Boundary Wall (height of the wall shall be 1800 mm (excluding barbed wire and concertina coil) from NGL or asmentioned in the drawing) including excavation, PCC, RCC, reinforcement etc complete as per drawing in all respect. M 1000 Included 0 0 0
204 10 500 Civil Works 100001478 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 2-2 M 250 Included 0 0 0
205 10 510 Civil Works 100001479 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 3-3 M 50 Included 0 0 0
206 10 520 Civil Works 100001480 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 4-4 M 25 Included 0 0 0
207 10 530 Civil Works 100007097 995454 18 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete including construction of 600 mm high and230 mm wide cement concrete (1:3:6) (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) toe wall atthe lowest portion of stone pitching area etc. completed as per theinstruction of Engineer-In-Charge. . M2 201 Included 0 0 0
208 10 540 Civil Works 100001721 995428 18 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers notexceeding 250mm thickness including ramming, watering compacting M3 1799 Included 0 0 0
209 10 550 Civil Works 100001743 995414 18 PEB - 400 kV GIS - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 1000 Included 0 0 0
210 10 560 Civil Works 100004431 995416 18 400 kV PEB Panel Room for GIS Hall - Civil Works All civil works complete as per TS, including - brickwork, finishing (externaland internal), windows etc. However, excavation, concrete (all types) and reinforcement steel shall be measured and paid separatelyas per respective item of BPS. M2 100 Included 0 0 0
211 10 570 Civil Works 100004427 995416 18 400 kV PEB AHU Room for GIS Hall - Civil Works All civil works complete as per TS, including - brickwork, finishing (external andinternal), windows etc. However, excavation, concrete (all types) and reinforcement steel shall be measured and paid separately asper respective item of BPS. M2 50 Included 0 0 0
212 10 580 Civil Works 100001697 995454 18 Car Parking (8 cars) - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc.However,excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 150 Included 0 0 0
II 400kV Koldam Extn. Revaluation of J column Tax Calculation
213 200 10 Insta. Bus Reactor 100018035 998736 18 41.67 MVAR, 420KV, 1-PHASE BUS REACTOR EXCLUDING INSULATING OIL EA 4 Included 0 0 0
214 200 20 Insta. Bus Reactor 100018036 998736 18 INSULATING OIL FOR 41.67 MVAR, 420KV 1-PHASE BUS REACTOR SET 4 Included 0 0 0
215 210 10 Insta. AIS Equipment 100000267 998736 18 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 2 Included 0 0 0
216 210 20 Insta. AIS Equipment 100000274 998736 18 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 6 Included 0 0 0
217 210 30 Insta. AIS Equipment 100000275 998736 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 3 Included 0 0 0
218 210 40 Insta. AIS Equipment 100000287 998736 18 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 6 Included 0 0 0
219 210 50 Insta. AIS Equipment 100000328 998736 18 336kV Surge Arrester (1-phase) EA 3 Included 0 0 0
220 210 60 Insta. AIS Equipment 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 16 Included 0 0 0
221 220 10 Insta of erection hardware 100000343 998731 18 Erection Hardware for 400kV D type layout-Bus Reactor bay as per specification SET 1 Included 0 0 0
222 220 20 Insta of erection hardware 100000341 998731 18 Erection Hardware for 400kV D type layout-Line bay as per specification SET 1 Included 0 0 0
223 230 10 Insta of Insulator & Hardware 100017126 998731 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 6 Included 0 0 0
224 230 20 Insta of Insulator & Hardware 100017127 998731 18 400KV TENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITHOUT TURN BUCKLE SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0 0 0
225 230 40 Insta of Insulator & Hardware 100017132 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH THROUGH CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0 0 0
226 230 50 Insta of Insulator & Hardware 100017133 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0 0 0
227 240 10 Insta. Control & Relay panels 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 2 Included 0 0 0
228 240 20 Insta. Control & Relay panels 100000730 998736 18 400kV Line Protection Panel (with Automation) EA 1 Included 0 0 0
229 240 30 Insta. Control & Relay panels 100000735 998736 18 Augmentation of existing 400kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 Included 0 0 0
230 240 40 Insta. Control & Relay panels 100000732 998736 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0 0 0
231 250 10 Insta. of Substation automation system 100002069 998736 18 Augmentation of Substation automation System for 400kV Main bay as per Technical Specification EA 1 Included 0 0 0
232 250 20 Insta. of Substation automation system 100002075 998736 18 Augmentation of Substation automation System for 400kV Tie bay as per Technical Specification EA 1 Included 0 0 0
233 260 10 Insta. of PLCC 100002042 998734 18 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included 0 0 0
234 260 20 Insta. of PLCC 100000883 998734 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 6 Included 0 0 0
235 270 10 Insta. of Indoor Illumination system 100001116 998739 18 Illumination System for switchyard panel room of 6 m length SET 1 Included 0 0 0
236 275 10 Insta. of Outdoor Illumination system 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 1 Included 0 0 0
237 275 20 Insta. of Outdoor Illumination system 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 10 Included 0 0 0
238 275 30 Insta. of Outdoor Illumination system 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 10 Included 0 0 0
239 290 10 Insta of FF system 100002062 995461 18 Fire Detection and Alarm System for Switchyard Panel Room of 6 m length SET 1 Included 0 0 0
240 290 20 Insta of FF system 100000975 995461 18 4.5 kg CO2 type Portable Fire extinguisher EA 4 Included 0 0 0
241 290 30 Insta of FF system 100000976 998736 18 6Kg dry chemical powered type Portable Fire extinguisher EA 2 Included 0 0 0
242 290 40 Insta of FF system 100018037 998736 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING AND ACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 41.67 MVAR, 420KV, 1PHASE BUS REACTOR SET 4 Included 0 0 0
243 295 10 Insta. of Air condition system 100001882 995463 18 Air conditioning system for Switchyard Panel Room of 6m length SET 1 Included 0 0 0
244 310 10 Insta. of Power & control cable 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
245 310 20 Insta. of Power & control cable 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
246 310 30 Insta. of Power & control cable 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
247 320 10 Erection of Earthmat 100003103 998731 18 40 mm MS rod for Main Earthmat KM 1 Included 0 0 0
248 330 10 Insta. of VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 1 Included 0 0 0
249 340 10 Erection of Equip. Structure 100008219 995455 18 Equipment Structure including Foundation bolt-400kV CT (1Ph) EA 6 Included 0 0 0
250 340 20 Erection of Equip. Structure 100008220 995455 18 Equipment Structure including Foundation bolt-400kV CVT (1Ph) EA 3 Included 0 0 0
251 340 30 Erection of Equip. Structure 100008222 995455 18 Equipment Structure including Foundation bolt-400kV class SA (1Ph) EA 3 Included 0 0 0
252 340 40 Erection of Equip. Structure 100008221 995455 18 Equipment Structure including Foundation bolt-400kV Isolator (3Ph) EA 6 Included 0 0 0
253 340 50 Erection of Equip. Structure 100008223 995455 18 Equipment Structure including Foundation bolt-400kV BPI (1Ph) EA 16 Included 0 0 0
254 340 60 Erection of Equip. Structure 100008224 995455 18 Equipment Structure including Foundation bolt-400kV Wave Trap (1Ph) EA 2 Included 0 0 0
255 360 10 PMU & associated items (Koldam SS) 170000502 998713 18 Service:- Phasor Measurement Unit (PMU) EA 1 Included 0 0 0
256 360 20 PMU & associated items (Koldam SS) 170000530 998734 18 WAMS TIME SYSTEM(GPS RECEIVER) EA 1 Included 0 0 0
257 360 30 PMU & associated items (Koldam SS) 170000503 998713 18 Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 2 Included 0 0 0
258 360 40 PMU & associated items (Koldam SS) 170000504 998713 18 Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0 0 0
259 360 50 PMU & associated items (Koldam SS) 170000501 998734 18 Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0 0 0
260 380 10 Ser- Tele Eqpt at Koldam 100002812 998734 18 SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0 0 0
261 380 20 Ser- Tele Eqpt at Koldam 170000433 998734 18 Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0 0 0
262 380 30 Ser- Tele Eqpt at Koldam 170000435 998734 18 Optical Interface Cards/SFP# -L16.2 for SDH Equipment-STM-16 EA 2 Included 0 0 0
263 380 40 Ser- Tele Eqpt at Koldam 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0 0 0
264 380 50 Ser- Tele Eqpt at Koldam 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0 0 0
265 380 60 Ser- Tele Eqpt at Koldam 100002829 998734 18 Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0 0 0
266 380 70 Ser- Tele Eqpt at Koldam 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 Included 0 0 0
267 380 80 Ser- Tele Eqpt at Koldam 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 Included 0 0 0
268 380 90 Ser- Tele Eqpt at Koldam 100002882 998336 18 Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1 Included 0 0 0
269 380 100 Ser- Tele Eqpt at Koldam 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 Included 0 0 0
270 390 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 4994 Included 0 0 0
271 390 20 Civil Works 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 1249 Included 0 0 0
272 390 30 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 153 Included 0 0 0
273 390 40 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 47 Included 0 0 0
274 390 50 Civil Works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1212 Included 0 0 0
275 390 60 Civil Works 100001329 995454 18 Steel Reinforcement MT 91 Included 0 0 0
276 390 70 Civil Works 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 58 Included 0 0 0
277 390 80 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 56 Included 0 0 0
278 390 90 Civil Works 100001712 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 5500 Included 0 0 0
279 390 100 Civil Works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 720 Included 0 0 0
280 390 120 Civil Works 100008110 995421 18 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 375 Included 0 0 0
281 390 130 Civil Works 100001458 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 252 Included 0 0 0
282 390 140 Civil Works 130000761 995428 18 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 40 Included 0 0 0
283 390 150 Civil Works 130000762 995428 18 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 172 Included 0 0 0
284 390 160 Civil Works 100020960 995461 18 RCC culvert crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
285 390 170 Civil Works 100020961 995461 18 RCC culvert crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
286 390 180 Civil Works 100020962 995461 18 RCC culvert crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
287 390 190 Civil Works 100001409 995462 18 Supplying and erecting dewatering pumps-5 HP EA 1 Included 0 0 0
288 390 200 Civil Works 100015791 995454 18 All civil works for Drains construction of Section A-A including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 Included 0 0 0
289 390 210 Civil Works 100015792 995454 18 All civil works for Drains construction of Section B-B including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 Included 0 0 0
290 390 220 Civil Works 100015793 995454 18 All civil works for Drains construction of Section C-C including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 Included 0 0 0
291 390 230 Civil Works 100015794 995454 18 All civil works for Drains construction of Section D-D including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 Included 0 0 0
292 390 240 Civil Works 100001433 995435 18 Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0 0 0
293 390 250 Civil Works 100001478 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 2-2 M 20 Included 0 0 0
294 390 260 Civil Works 100001479 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 3-3 M 20 Included 0 0 0
295 390 270 Civil Works 100001480 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 4-4 M 20 Included 0 0 0
296 390 280 Civil Works 100007097 995454 18 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete including construction of 600 mm high and230 mm wide cement concrete (1:3:6) (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) toe wall atthe lowest portion of stone pitching area etc. completed as per theinstruction of Engineer-In-Charge. . M2 99 Included 0 0 0
297 390 290 Civil Works 100001721 995428 18 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers notexceeding 250mm thickness including ramming, watering compacting M3 374 Included 0 0 0
298 390 110 Civil Works 100003437 995454 18 Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 30 Included 0 0 0
299 400 10 Erection of Towers & Gantry Structure 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 9 Included 0 0 0
300 400 20 Erection of Towers & Gantry Structure 100001209 995455 18 Erection of Lattice Structures (HT Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts. MT 11 Included 0 0 0
301 400 30 Erection of Towers & Gantry Structure 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 1 Included 0 0 0
302 400 40 Erection of Towers & Gantry Structure 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 2 Included 0 0 0
III Switchable Line Rector at Ropar Revaluation of J column Tax Calculation
303 130 10 Insta. Line Reactor 100000057 998736 18 50 MVAR,420kV,3-phase Shunt Reactor excluding Insulating Oil EA 1 Included 0 0 0
304 130 20 Insta. Line Reactor 100001925 998736 18 Insulating Oil for 50 MVAR,420kV ,3-phase Shunt Reactor SET 1 Included 0 0 0
305 130 30 Insta. Line Reactor 100000052 998736 18 Oil filled Neutral Grounding Reactor (NGR) along with support structure & terminal connector SET 1 Included 0 0 0
306 140 10 Insta. of AIS Equipment 100000267 998736 18 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 1 Included 0 0 0
307 140 20 Insta. of AIS Equipment 100000287 998736 18 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 1 Included 0 0 0
308 140 30 Insta. of AIS Equipment 100000328 998736 18 336kV Surge Arrester (1-phase) EA 3 Included 0 0 0
309 140 40 Insta. of AIS Equipment 100000587 998736 18 120kV Surge Arrester(1-phase) EA 1 Included 0 0 0
310 140 50 Insta. of AIS Equipment 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 3 Included 0 0 0
311 150 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 840 Included 0 0 0
312 150 20 Civil Works 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 210 Included 0 0 0
313 150 30 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 39 Included 0 0 0
314 150 40 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 18 Included 0 0 0
315 150 50 Civil Works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 266 Included 0 0 0
316 150 60 Civil Works 100001329 995454 18 Steel Reinforcement MT 19 Included 0 0 0
317 150 70 Civil Works 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 15 Included 0 0 0
318 150 80 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 15 Included 0 0 0
319 150 90 Civil Works 100001712 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 1500 Included 0 0 0
320 150 100 Civil Works 100008110 995421 18 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 113 Included 0 0 0
321 150 110 Civil Works 100001458 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 126 Included 0 0 0
322 150 120 Civil Works 130000761 995428 18 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 10 Included 0 0 0
323 150 130 Civil Works 130000762 995428 18 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 61 Included 0 0 0
324 150 140 Civil Works 100020960 995461 18 RCC culvert crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
325 150 150 Civil Works 100020961 995461 18 RCC culvert crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
326 150 160 Civil Works 100020962 995461 18 RCC culvert crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as per specification. M 10 Included 0 0 0
327 150 170 Civil Works 100015791 995454 18 All civil works for Drains construction of Section A-A including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 15 Included 0 0 0
328 150 180 Civil Works 100015792 995454 18 All civil works for Drains construction of Section B-B including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 15 Included 0 0 0
329 150 190 Civil Works 100015793 995454 18 All civil works for Drains construction of Section C-C including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 15 Included 0 0 0
330 150 200 Civil Works 100015794 995454 18 All civil works for Drains construction of Section D-D including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 15 Included 0 0 0
331 150 210 Civil Works 100001433 995435 18 Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0 0 0
332 150 220 Civil Works 100001479 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 3-3 M 10 Included 0 0 0
333 150 230 Civil Works 100001480 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 4-4 M 10 Included 0 0 0
334 150 240 Civil Works 100007097 995454 18 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete including construction of 600 mm high and230 mm wide cement concrete (1:3:6) (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) toe wall atthe lowest portion of stone pitching area etc. completed as per theinstruction of Engineer-In-Charge. . M2 99 Included 0 0 0
335 150 250 Civil Works 100001721 995428 18 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers notexceeding 250mm thickness including ramming, watering compacting M3 101 Included 0 0 0
336 150 260 Civil Works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 240 Included 0 0 0
337 160 10 Insta. of Erection Hardware 100000336 998731 18 Erection Hardware for 400kV I type layout-Line Reactor as per specification SET 1 Included 0 0 0
338 170 10 Insta. 400kV Insulator & hardware 100017133 998731 18 400KV SUSPENSION INSULATOR STRING AND ASSOCIATED HARDWARE FITTINGS WITH DROP CLAMP SUITABLE FOR QUAD CONDUCTOR EA 3 Included 0 0 0
339 180 10 Insta Control & Relay Panel 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 1 Included 0 0 0
340 180 20 Insta Control & Relay Panel 100000732 998736 18 400kV Reactor Protection Panel (with Automation) EA 1 Included 0 0 0
341 180 30 Insta Control & Relay Panel 100000268 998736 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 1 Included 0 0 0
342 190 10 Insta. Susstation Automation 100000779 998736 18 Complete Substation automation System for 400kV Switchable Line Reactor Bay as per Technical Specification EA 1 Included 0 0 0
343 200 10 Insta. Outdoor Illumination system 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 1 Included 0 0 0
344 200 20 Insta. Outdoor Illumination system 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 2 Included 0 0 0
345 200 30 Insta. Outdoor Illumination system 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 2 Included 0 0 0
346 200 40 Insta. Outdoor Illumination system 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 Included 0 0 0
347 210 10 Insta. of FF System 100001007 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 50 MVAR, 420kV, 3phase shunt Reactor SET 1 Included 0 0 0
348 220 10 Insta. of Power & Control Cable 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
349 220 20 Insta. of Power & Control Cable 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
350 220 40 Insta. of Power & Control Cable 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0 0 0
351 230 10 insta. of Earthmat 100003103 998731 18 40 mm MS rod for Main Earthmat KM 1 Included 0 0 0
352 240 10 Insta of VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 1 Included 0 0 0
353 250 10 Insta of Equipment structure 100008222 995455 18 Equipment Structure including Foundation bolt-400kV class SA (1Ph) EA 3 Included 0 0 0
354 250 20 Insta of Equipment structure 100008221 995455 18 Equipment Structure including Foundation bolt-400kV Isolator (3Ph) EA 1 Included 0 0 0
355 250 30 Insta of Equipment structure 100008223 995455 18 Equipment Structure including Foundation bolt-400kV BPI (1Ph) EA 3 Included 0 0 0
GRAND TOTAL 0 0
Note : The Price quoted against Supply, F&I & Erection & commissioning for BPL Service connection Including taxes and duties shall be limited to Rs 3000/- per service connection
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date -- Printed Name:
Place Designation :
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 4
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES : TRAINING CHARGES)
Bidder’s Name and Address (Sole Bidder) : To: To:
#REF! Contracts Services, 3rd Floor
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No.-2
#REF! Sector-29,
#REF! Gurgaon (Haryana) - 122001
TRAINING CHARGES
PRICE COMPONENT OF TRAINING TO BE IMPARTED TO OWNER'S PERSONNEL BY BIDDER'S INSTRUCTOR
All Prices are in Indian Rupees.
Sl. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘….’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Country where training is to be imparted Item for which training is to be imparted Training duration in days Unit Quantity Unit Chargers Total Training Charges Total GST as confirmed by Bidder
1 Not Applicable 0.00 0 0
Total for Training Charges [Total Schedule 4)] 0 0.00
1 All reasonable expenses for trainee including the round trip air fare up to manufacturer's plant, the food & hotel accomodation charges and local travel during their stay for training period, accommodation for the Instructor (Trainer) and Training material for the Trainees shall be included in the prices quoted by the bidder
2 * In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
3 For taining at site, the bidder shall considered the expenses of the instructor (Trainer) only
Date : -- Printed Name Printed Name:
Place : Designation : Designation :
Spec.No. Schedule - 3
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
#REF! Total Discount #REF!
Address : #REF!
#REF! Multipackage lum-sum #REF!
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
2.1 #REF! #REF! #REF! (a) Detailed Soil Investigation
(a) #REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
(b) #REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF! Wet Soil
(b) #REF! #REF! #REF! #REF! #REF! Dry Fissured Rock
(c) #REF! #REF! #REF! #REF! #REF! Wet Fissured Rock
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
4.3 #REF! #REF! #REF! #REF! #REF!
4.4 #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
(d) #REF! #REF! #REF! #REF! #REF!
(e) #REF! #REF! #REF! #REF! #REF!
(f) #REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
(c) #REF! #REF! #REF! #REF! #REF!
9.1 #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
(a) #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
11.2 #REF! #REF! #REF! #REF! #REF!
11.3 #REF! #REF! #REF! #REF! #REF!
11.4 #REF! #REF! #REF! #REF! #REF!
11.5 #REF! #REF! #REF! #REF! #REF!
11.6 #REF! #REF! #REF! #REF! #REF!
11.7 #REF! #REF! #REF! #REF! #REF!
11.8 #REF! #REF! #REF! #REF! #REF!
11.9 #REF! #REF! #REF! #REF! #REF!
11.10 #REF! #REF! #REF! #REF! #REF!
11.11 #REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B+C) #REF!
Place : #REF! Printed Name : #REF!
Designation : #REF!
Spec.No. Schedule - 4
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES : TRAINING CHARGES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : #REF! #REF!
Address : #REF!
Training Charges
1. Price Component of training to be imparted to Employer's Personnel by Bidder's instructor
Sl. No. Description Country where training is to be imparted Item for which training is to be imparted Training duration in days Training Charges
per DIEM Rate Total Amount
1 The Bidder shall impart necessary training to Employer's Six personnel on design, operation, maintenance and commissioning aspect as per technical specification at manufacturer’s /supplier’s works. Transformer 3 Included
PLCC 3 Included
Control, Protection & Automation 5 Included
Switchyard Equipments (CB,CT,CVT, Isolators & LA 3 Included
Total for Training Charges [Total Schedule 4)] #REF! #REF!
NOTE: To and fro charges and accommodation for the Instructor (Trainer) and Training material for the Trainees shall be included in the prices quoted by the bidder.
Date : #REF! #REF!
Place : #REF! #REF!
Spec.No. Schedule - 4b
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES : MAINTENANCE CHARGES)
Bidder’s Name and Address (Sole Bidder) : To:
Name : #REF! #REF!
Address : #REF!
Maintenance Charges
Sl. No. Description Unit Qty. Total
1 Maintenance Charges for Communication system for one (1) year during Warranty period Year 1
2 Maintenance Charges for Communication system for Six (6) years after expiry of Warranty period Year 6
Total Maintenance Charges for Communication Equipment #REF! #REF!
Date : #REF! Printer Name: 0
Place : #REF! Designation: 0
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 5
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : To: To:
Contracts Services, 3rd Floor #REF! #REF!
Name : Power Grid Corporation of India Ltd., #REF! #REF!
Address : "Saudamini", Plot No.-2 #REF!
Sector-29, #REF!
Gurgaon (Haryana) - 122001 #REF!
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4) 0.00
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name: Printed Name
Place : Designation : Designation :
Spec.No. Schedule - 5
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Sole Bidder) : To:
Address : #REF!
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL EXCISE DUTY #REF! Excise Duty #REF! Excise Duty #REF!
Total Excise Duty for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
Rate of Excise Duty for Direct items indicated in Sch-1 #REF!
2 TOTAL SALES TAX #REF! Sales Tax 0.00 Sales Tax 0.00
Total Sales Tax for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. #REF! #REF! #REF! #REF!
Amount on which Sales Tax is applicable [only ex-w price] #REF! Amount #REF! Amount #REF!
#REF! #REF! ED #REF! ED #REF!
Rate of Sales Tax #REF!
3 TOTAL VAT #REF! Vat 0 Vat 0
Total VAT for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable #REF! #REF! #REF! #REF!
Amount on which VAT is applicable [only ex-w price] #REF! Amount #REF! Amount #REF!
#REF! #REF! ED #REF! ED #REF!
Rate of VAT #REF!
4 TOTAL OCTROI #REF!
Total Octroi as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1.
Amount on which Octroi is applicable Click here for details of Octroi
5 TOTAL ENTRY TAX #REF!
Total Entry Tax as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1.
Amount on which Entry Tax is applicable Click here for details of Entry Taxes
6 TOTAL OTHER TAXES & DUTIES #REF!
Total Others levies payable in India (please specify) as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1.
Amount on which Other Taxes & Duties are applicable Click here for details of Other Taxes & Duties
GRAND TOTAL [1+2+3] #REF! Grand Total after Discount #REF! Grand Total after MPD #REF!
Above Grand Total does not include Octroi, Entry Tax , Other Taxes & Duties quoted by bidder at Sl. No. 4,5 & 6 above Plus Octroi, Entry Tax , Other Taxes & Duties quoted by bidder at Sl. No. 4,5 & 6 above
Note : The reimbursement of Excise Duty, Sales Tax/VAT and other levies as per Sl. No. 1, 2 & 3 above subject to provision of ITB Clause 11.4 shall be only against those items for which the Mode of Transaction indicated in Schedule - 1 is 'Direct'. In case of those items in the said Sechedule-1 against which the mode of transaction has been left blank, the same shall be deemed to be 'Bought-out' for the purpose of Evaluation and award of Contract and the price indicated in Schedule 1 against such items shall be deemed to be inclusive of all such taxes, duties and levies.
Date : #REF! Printed Name : #REF!
Place : #REF! Designation : #REF!
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 6
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To: To:
Contracts Services, 3rd Floor #REF! #REF!
Name : Power Grid Corporation of India Ltd., #REF! #REF!
Address : "Saudamini", Plot No.-2 #REF!
Sector-29, #REF!
Gurgaon (Haryana) - 122001 #REF!
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name: Printed Name
Place : Designation : Designation :
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule - 6
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
(GRAND SUMMARY: AFTER DISCOUNT)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00 #DIV/0! 0.00 0
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00 #DIV/0! 0.00 0
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00 #DIV/0! 0.00 0
Installation Charges
4 TOTAL SCHEDULE NO. 4 #DIV/0! 0.00 0
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 #DIV/0! 0.00 0
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name:
Place : Designation :
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Schedule 7
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount #REF!
Gurgaon (Haryana) - 122001
TYPE TESTS CHARGES
All Prices are in Indian Rupees.
Sl. No. PR No Line Item No Activity Description Code HSN Code Whether HSN in column ‘ 2 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Charges Type test Charges (INR) Total for Type Test charges
NOT APPLICABLE Included 0 0 0
Total Type Test Charges 0.00 0
Note * In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Discount Sche-7 #REF! MPD Sche-7 #REF!
Date: -- Printed Name:
Place: Designation :
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. 0
(SCHEDULE OF RATES AND PRICES) 0
Bidder’s Name and Address (Sole Bidder) :
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
#REF! Total Discount #REF!
Address : #REF!
#REF! Multipackage Discount #REF!
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (A.1) #REF!
TOTAL TEST CHARGES #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : #REF! #REF!
Place : #REF! #REF!
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Letter of Discount Schedule 1 0.00
LETTER OF DISCOUNT Schedule 3 0
To: Schedule 4 0
Contract Services Schedule 7 0.00
Power Grid Corporation of India Ltd., Total 0.00
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3 Sch-4 Sch-7 Discounts in Rs.
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3] In Rs. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3] In Percent (%) 0.00 0.00 0.00 0.00 0.00 #REF!
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1: Ex Works prices In Rs. 0.00 X X X X 0.00
Schedule-2 : Freight & Insurance In Rs. X 0.00 X X X 0.00
Schedule-3 : Erection Charges In Rs. X X 0.00 X X 0.00
Schedule-4 : Training Charges In Rs. X X X 0.00 X 0.00
Schedule-7 : Type Test Charges In Rs. X X X X 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1: Ex Works prices In Percent (%) 0.00 X X X X
Schedule-2 : Freight & Insurance In Percent (%) X 0.00 X X X
Schedule-3 : Erection Charges In Percent (%) X X 0.00 X X
Schedule-4 : Training Charges In Percent (%) X X X 0.00 X
Schedule-7 : Type Test Charges In Percent (%) X X X X 0.00
Discount(s) offered at sl. No. 1 to 3 will automatically get displayed and accounted for in the respective items of the Schedules.
Please consider this letter of discount as the integral part of our price bid. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Thanking you, we remain, #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges #REF! #REF!
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. #REF! #REF!
3 TOTAL SCHEDULE NO.3: Installation Charges #REF! #REF!
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) #REF! #REF!
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! #REF!
B) CENTRAL SALES TAX #REF! #REF!
C) VAT #REF! #REF!
D) ENTRY TAX / OCTROI #REF! #REF!
E) OTHERS #REF! #REF!
F) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] #REF! #REF!
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
#REF! #REF! Excise Duty #REF! #REF! #REF! #REF!
#REF! #REF! CST #REF! #REF! #REF! #REF!
#REF! #REF! VAT #REF! #REF! #REF! #REF!
#REF! #REF! Entry Tax/ Octroi #REF! #REF!
#REF! #REF! Others #REF! #REF!
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. #REF!
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. #REF!
c) Amount on which Sales Tax is applicable #REF! #REF!
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. #REF!
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% #REF!
f) Others [……………………………………………] Rs. #REF!
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF!
h) Entry Tax, as applicable on (e) above at the rate : Rs. #REF!
Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC. Statement of Quoted / Corrected Prices Page
#REF! Excise Duty #REF! #REF! #REF! #REF!
Sl. No. Clause Ref. No. Description of Clause Observation/ Comment of the Bidder Remarks #REF! CST #REF! #REF! #REF! #REF!
1 Clause 10 Taxes and Duties, Section-IV, GCC 10. Taxes and Duties #REF! VAT #REF! #REF! #REF! #REF!
10.1 The Supplier shall be entirely responsible for payment of all taxes, duties, licence fees ………………………. #REF! #REF! Entry Tax/ Octroi #REF! #REF!
10.2 The Supplier shall be solely responsible for the taxes that may be levied on the Supplier's persons ……………………….. #REF! #REF! Others #REF! #REF!
10.3 In respect of direct transaction between the Purchaser and the Supplier, the EXW price is inclusive………………………….. #REF!
10.4 Octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items, which shall be dispatched directly from the …………………………………… #REF!
10.5 Purchaser would not bear any liability on account of Service Tax. ………………. #REF!
10.6 Sales Tax/VAT on Works Contract, Turnover Tax or any other similar taxes under the …………………………………..
10.7 For the purpose of the Contract, it is agreed that the Contract Price specified in Article 2(Contract Price and Terms of Payment) of the Contract Agreement is based on the taxes, duties, levies and charges prevailing at the date seven (07) days prior to the last date of bid submission (hereinafter called “Tax” in this GCC Sub-clause 10.7). .……………........................................
In respect of raw materials, intermediary components etc and bought out items, neither the Purchaser nor the Supplier shall be entitled to any claim arising due to increase or decrease in the rate of Tax, ……………………………………………....
2 Clause 29 Change in Laws and Regulations, Section-IV, GCC 29.1 If, after the date seven (07) days prior to the date of Bid Opening, any law, regulation, ordinance, order or by-law having the force of law is enacted, promulgated, abrogated or changed in India (which shall be deemed to include any change in interpretation or application by the competent authorities) ……………………………………….
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Spec.No TBCB/Lahuri/Nange /400kV/GIS/SS01/G5 Bid Form 2nd Envelope
BID FORM (Second Envelope)
Bid Proposal Ref. No.
Contracts Services, 3rd Floor
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Name of Contract : Pre Bid Tie up for 400kV GIS Substation Package SS01 associated with “Transmission system for evacuation of power from Luhri Stage-I HEP”through Tariff Based Competitive Bidding (TBCB) route prior to RfP bid submission by POWERGRID to BPC.
Dear Ladies and/or Gentlemen,
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges.
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading
Schedule 3 Installation Charges.
Schedule 4 Training charges for training to be imparted.
Schedule 5 GST not included in Schedule 1
Schedule 6 Grand Summary [Schedule 1to 5]
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all GST and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01-First Envelope - Bid Form and Attachments_Nange GIS.xlsx
xlsx • 1.30 MB
02-Attachment-8-Manufacturer Authorisation Form.doc
doc • 0.03 MB
03-Attachment-18-SAFETY PACT.docx
docx • 0.03 MB
04_Attachment-20_KMP Declaration.doc
doc • 0.04 MB
05-Attachment 21- Authorization certificate issued by Domestic Manufacturer.docx
docx • 0.02 MB
06-Attachment-22- Affidavit for self-certification.DOCX
docx • 0.02 MB
07-Attachment - 23-Affidavit.docx
docx • 0.02 MB
08-Attachment -25-Declaration regarding events encountered.docx
docx • 0.03 MB
09-Attachment 26- certifacte by bidder.docx
docx • 0.02 MB
10-Attachemnt-27- Affidavit for self-certifictaion.DOCX
docx • 0.02 MB
11-Attachment 28- certificate by Auditor.docx
docx • 0.02 MB
12-Attachment-29_Confirmation in regard to Design and Type Test.docx
docx • 0.02 MB
13-Attachment-30-Bid-Securing Declaration.docx
docx • 0.02 MB
14_Attachment -3 (QR)-Nange GIS.xlsx
xlsx • 0.17 MB
15-Second Envelope - Bid Form and Price Schedule_Nange GIS.xlsx
xlsx • 1.24 MB
10 Details of drain.pdf
pdf • 2.24 MB
11 Standard drawing for Rain water harvesting structr.pdf
pdf • 0.19 MB
12 SPR 6 MTR.pdf
pdf • 3.93 MB
13 Typical module.pdf
pdf • 0.14 MB
14 Standard_AC_DC_SLD_765kVSubstation.pdf
pdf • 0.23 MB
4 Details of Main entrance gate.pdf
pdf • 0.85 MB
5A Architectural Details of security hut-1.pdf
pdf • 0.28 MB
5BStructural Details of security hut-1.pdf
pdf • 0.25 MB
6 Standard details for switchyard barbed wire fencing.pdf
pdf • 0.47 MB
7 Details of switchyard gate.pdf
pdf • 1.20 MB
8 Details of bituminous road.pdf
pdf • 0.44 MB
9 Details of cable trench and cable trench road crossings.pdf
pdf • 0.63 MB
1 Architectural details of FFPH.pdf
pdf • 2.29 MB
2 Architectural Drawing 8cars parking shed.pdf
pdf • 2.50 MB
3 Details of Pre-fabricated RCC Boundary wall.pdf
pdf • 4.30 MB
19_ TS Civil Works Rev 11A with correction slips.pdf
pdf • 4.56 MB
20_ Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
21_Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
21_Section-Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
22_ Section PMU Rev 0.pdf
pdf • 0.59 MB
23_ PLCC R5.pdf
pdf • 0.06 MB
24_ Section Telecommunication Systems Rev 02.pdf
pdf • 1.78 MB
11_ Fire Protection Rev 6.pdf
pdf • 1.97 MB
12_ LT Transformer-Rev05.pdf
pdf • 0.07 MB
13_DG Set Rev 5.pdf
pdf • 0.27 MB
14_ Battery&Charger R6.pdf
pdf • 1.05 MB
15_ LT Switchgear R5.pdf
pdf • 0.47 MB
16_ Air conditioning R4.pdf
pdf • 0.04 MB
17_ Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
18_ Section Structure Rev 6.pdf
pdf • 0.10 MB
10_ Lighting Specification Rev.07.pdf
pdf • 4.29 MB
4_ GIS Rev-5A.pdf
pdf • 1.95 MB
5_Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
6_Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
7_Section-Switchgear-SA_Rev12.pdf
pdf • 0.34 MB
8_Section-Switchgear-ISO_Rev12.pdf
pdf • 0.17 MB
9_Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
2_GTR Rev 15.pdf
pdf • 7.12 MB
3_420kV Reactor_REV_11.pdf
pdf • 2.60 MB
1_Section Project R0.pdf
pdf • 8.54 MB
00-Cover.doc
doc • 2.56 MB
01- Section-I IFB(GIS).doc
doc • 0.10 MB
02 - Section - II ITB.pdf
pdf • 1.95 MB
03 - Section - III BDS.docx
docx • 0.08 MB
04-Annexure-A (BDS)-Nange GIS.doc
doc • 0.09 MB
05 - Section - IV GCC.pdf
pdf • 1.93 MB
06- Section-V-SCC (GIS).docx
docx • 0.06 MB
07-Appendix -I to SCC.doc
doc • 0.17 MB
08-Section - VI Forms and Proceedures (GIS).doc
doc • 0.61 MB
OBD_EXTN-XIV_Letter-Lahuri-Nange_GIS.docx.pdf
pdf • 0.23 MB
OBD_EXTN-XII_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
15-Second Envelope - Bid Form and Price Schedule_Nange GIS_Rev3.xlsx
xlsx • 1.24 MB
OBD_EXTN-XII_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
OBD_EXTN-XI_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
OBD_EXTN-X_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
OBD_EXTN-IX_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
OBD_EXTN-VIII_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
01_Clarification No-V-Lahuri.pdf
pdf • 0.17 MB
01_Clarification No-IV-Lahuri.pdf
pdf • 0.18 MB
OBD_EXTN-VII_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
15-Second Envelope - Bid Form and Price Schedule_Nange GIS_Rev2.xlsx
xlsx • 1.24 MB
OBD_EXTN-VI_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.23 MB
OBD_EXTN-V_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.22 MB
01_Amendment No-IV.pdf
pdf • 0.06 MB
OBD_EXTN-IV_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.22 MB
OBD_EXTN-III_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.22 MB
Annexure IV Rev-01 -Technical Particulars 41.67 MVAR Reactor.pdf
pdf • 0.16 MB
OBD_EXTN-II_Letter-Lahuri-Nange_GIS.docx
docx • 0.17 MB
01_Clarification No-I-Commercial portion-Lahuri.docx
docx • 0.03 MB
OBD_EXTN-I_Letter-Lahuri-Nange_GIS.pdf
pdf • 0.22 MB
01_Amendment No-II.pdf
pdf • 0.10 MB
01_Amendment No-I.pdf
pdf • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .