Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹5.7 L
Closing Date
30 Sept 2026, 2:00 pm7d left
Published by the portal on this tender, for queries and grievance redressal.
AMC of Airfield Ground lighting
9903923
GEM/2026/B/8046065
Two Packet Bid
Operation and Maintenance of Electrical And Mechanical
Tuticorin, Tamil Nadu
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹51 L
80%
APD Thoothukudi Airport, O/o Airport Director, Airports Authority of India, Thoothukudi Airport, Tuticorin -628103, (Airport Director)
₹5.7 L
16 Sept 2026
16 Sept 2026
1 Oct 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Operation and Maintenance of Electrical And Mechanical installations Ref ATC Pg.no SOQ 1 to 6 | Job Contract for Operation, preventive and breakdown Maintenance of various Electrical and Mechanical Installations, Such as Airport Ground Lighting, Old Power House, Nav-Aids and Ancillary Building, Fire detection and alarm system at Thoothukudi Airport as detailed on the tender Document on round the clock basis / as per need basis in line with the requirements indicated in the tender document and as required including providing Tools and Tackles, consumables, annual Calibration of measuring instruments complete etc as detailed in the special conditions/Technical specification of the contract. | 24 | Months | votk_elect_1 | 730 |
| 2 | Items under Electrical and mechanical DSR 2025 as per requirement Ref ATC Pg.no SOQ 1 to 6 | Execution of items of schedule of rates E and M CPWD DSR-2025 as and when required for attending breakdowns, repair and maintenance and upkeep of internal and external electrical installations at different locations of thoothukudi Airport as per direction of E-I-C. The bidder shall quote percentage (percentage) above / below the DSR 2025 rates in the form of multiplication factor. i.e. (for eg - If the bidder desires to quote 5percentage above on DSR 2025 rates, the rate column shall be filled as 1.05 and 5percentage below, the rate column shall be filled as 0.95). (Note DSR-2025 is inclusive of GST). | 8,26,000 | Percentage | votk_elect_1 | 730 |
| 3 | Installation of CI Housing Box Ref ATC Pg.no SOQ 1 to 6 | Installation of CI housing box along with cover plate of size 330 mm dia and depth up to 450 mm as per drawing i/c excavation of hard rock/pavement of all types/ concrete/bitumen etc. and all kinds of soil to the required depth, as per specifications, refilling the side surface, sloping and making good the same as original, providing cement concrete foundation of ratio 136 ( 1 cement, 3. coarse sand and 6 graded stone of 40 mm nominal size) and thickness of concrete at 75 mm in all sides i/c bottom dressing of earth, with brick and finishing with 13 mm thick cement plaster of ratio 13 on exposed surface and neat cement finishing on top etc. as required. | 10 | Job | votk_elect_1 | 730 |
| 4 | Laying of HDPE Pipe upto 63mm dia in ground Ref ATC Pg.no SOQ 1 to 6 | Laying of one number HDPE /PVC Pipe upto 63mm dia direct in ground upto depth of 80cm including excauation and refilling, leveling etc., | 500 | metre | votk_elect_1 | 730 |
| 5 | Drawing of AGL cables of 6 or 16sqmm cable Ref ATC Pg.no SOQ 1 to 6 | Drawing of AGL cables of 6/16 sq.mm size of cable in HDPE/GI/Hume Pipe | 500 | Metre | votk_elect_1 | 730 |
| 6 | Annual Servicing of 22KV 3 nos of HT breakers VCB Ref ATC Pg.no SOQ 1 to 6 | Servicing of 22KV, 3 Nos of HT breakers (VCB) (ABB make model VD4/W 36.12.32, 36KV,1250A VCB) provided at various power houses/substations, by deploying authorized service personnel of Manufacturer / Service dealer / Specialized service engineers experienced in similar nature of work, including drawing out of the VCB, opening the same, inspection, servicing, cleaning of contact surfaces, overhauling of operating mechanism, lubrication of moving parts, cleaning of CTs and measuring of contact resistance, meggering, testing of ON-OFF time, Testing and of operation etc. as required. ( Servicing of Three Breaker is considered as one Job) | 2 | Job | votk_elect_1 | 730 |
| 7 | Annual Servicing of 13 nos of L and T ACBs Ref ATC Pg.no SOQ 1 to 6 | Annual Inspection /Overhauling/Servicing of 13 Nos ACBs of L andT Make of various capacities (ACBs Make L andT,Model OMEGA ( U-Power ) FP, 2000A-3 Nos, 1250 A-10 Nos ) provided in the various LT panels at old Powerhouses/Substations by deploying Authorised Service Personnel of manufacturer/Service Dealer/Specialised Agencies experienced in servicing of ACBs including cleaning of ACBs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, checking of UV coils, Trip circuits, checking of control circuits, replacement of defective components and spares supplied by AAI, testing and commissioning etc as required. | 2 | Job | votk_elect_1 | 730 |
| 8 | Main Contact Assembly Fixed and Moving for 1600A OMEGA model ACBs Ref ATC Pg.no SOQ 1 to 6 | Main Contact Assembly (Fixed Moving) for 1600A ACBs | 4 | Each | votk_elect_1 | 730 |
| 9 | Main Contact Assembly Fixed and Moving for 1250A OMEGA model ACBs Ref ATC Pg.no SOQ 1 to 6 | Main Contact Assembly (Fixed and Moving) for 1250A ACBs | 8 | Each | votk_elect_1 | 730 |
| 10 | Shunt release operating voltage of 240V for OMEGA model ACBs Ref ATC Pg.no SOQ 1 to 6 | Shunt release suitable for operating voltage of 240V for L and T make OMEGA model ACB | 2 | Each | votk_elect_1 | 730 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9903923.pdf
GEM_BID • 0.33 MB
soq_final1_2026-09-16-20-08-04_f43e938da9661a5d1266f6c0f187c11e.pdf
BOQ • 0.18 MB
boq_item_sample_file1_2026-09-16-20-08-04_f13b3294bc8b171270fb3013a72d6c09.csv
BOQ • 0.02 MB
ATCAMC_ecd59449-2da6-4657-af701789574348376_votk_elect_1.pdf
GEM_OTHER • 3.44 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .