Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹40.4 L+₹1.5 L (3.83%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹44.2 L+₹5.2 L (13.5%)Rejected-Finance 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹46.6 L+₹7.7 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹47.8 L+₹8.9 L (22.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
5 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
PROVISION OF STAND BY SUPPLY AND VOLTAGE SERVO STABILIZER UG CHOC AND OTHER SANCTION WORKS UNDER GE (AF) BAMRAULI
2021_MES_494142_1
8710/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹93,200
20 Apr 2022
11 Dec 2021
6 Jan 2022
11 Dec 2021
5 Jan 2022
31 Dec 2021
60 days
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets all as sfd and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F in position premium sand textured finished mineral fibre acoustical ceiling tiles of size 600x600x16mm thick and placed on GI grid powder coated snap grid ceiling 600x600 module consisting of wall angle section19x19 mm and tee section with web height of 38mm and flange 15mm (colour white) (having rotary stitching on all T Section) with suspension system as shown in sketch 'B' and as approved by GE Note : (i) Ceiling tiles shall be of make Armstrong brand "DUNE RH99 (Bevelled/Tegular) or equivalent brand of make as specified in Appendix 'B' to particular. (ii) Thickness og GI section shall not less be less than 3mm and shall be procured from the tile manufacturer. (iii) Section and hanging system shall have galvanising of minimum 90 grams per sqm and same make of tile. (iv) Work shall be executed by manufacturer's authorised vendor.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for Rubber tiles 5mm thick with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
M&L for rendering 15mm thick on faces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:6, all as specified and directed.
M&L for rendering 15mm thick on other than faces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:4, all as specified and directed.
M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
M&L finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) approved shade of colour
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each. all as specified and directed.
M&L for power coated anodised aluminium doors (sliding/ hanging type) with frame size 101.60 x 44.45 x 2.00 mm thick and shutter aluminium anodised and top rail 47.62 x 44.45 x 1.50 mm style 47.5 x 44.5x1.5mm, lock rail 83.50 x 44.45 x 1.50 mm and bottom rail 150.00 x 44.50 x 2.50 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handle 150mm 02 Nos, aluminium tower bolts 200 mm 01 No, aluminium door stopper 01 Nos, jointing cleats glazing cleats, rubber packing, anodised aluminium shape beading screws etc with panelling in two parts with 12mm thick prelaminted particle board in lower panel and 5mm thick tinted glass in upper panels including all fittings & fixture complete all as specified and directed.
Taking down carefully LT Cable of any size and refix in into cable ducting or concealed it in wall as specified and directed by Eng-in-Charge( Note:- Cable ducting shall be measured and paid separately ).
S & F DLP UPVC trunking compartmant of 150x50 mm size with all accessories ie flexiable cover clip on seperates partitions lef tright top internal angle, flat angle, rasie function cover to body joints mosaic clip & supprot from mosaic isolation bracket 2 mm thick plastic complete all as directed by Engr-in-Charge
S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, verticle type suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, triple pole and neutral, 8 ways, 415 volts Note :- MCBs/MCCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement Factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, SPN, 8 ways, 240 volts, Note : MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement Factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, SPN, 4 ways, 240 volts, Note : MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in repair MCCB, four pole, 125 Amp rating, 25 KA ultimate breaking capacity , 415 Volt fixed in DBs catered here-in-before.
MCB, SP &N , 240 Volt ,32-63 Amp rating, 10 KA ultimate breaking capacity fixed in DBs catered herein before.
MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series suitable for fixing in DBs
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FR, 1100 Volts grade cable drawn into and including rigid PVC Conduit including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete including taking down old sub main wiring. Note:- (a) Two runs of 6.0 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 1.5 sq mm FR with stranded copper conductor 1 100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sq mm unsheathed copper conductor earth wire connected to earth dolly incl metal junction box ,grid plate,base plate suitable for modular switches, sockets, regulators. Note- (1) The rates of chase cutting on wall concealing conduit and steel terminal boxes are included in the unit rates.(2) colour code of wire will be strictly followed , Red for Phase , Black for neutral and green for earth wire(3) Switches & sockets shall be measured and paid for separately.
(a) One light/fan/bellpoint controlled by one switch single pole one way
All as per item No. 25 here-in-before but one 3 pin 5 amp switch socket out let independent .
All as per item No 25 here inbefore but one 3 pin 5 amps socket outlet on the same board with other switch complete .
All as per item No. 25 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board.
Supply and fix switch modular flush 6A single pole one way ISI marked (One module)
Supply and fix switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked
Supply and fix modular sockets 6 Amp 2 in 1 2/3 pin combined (Two module)
Supply and fix modular sockets 16 Amp 2 in 1 3/5 pin combined (Two module)
Supply and fix ceiling rose PVC/ polycarbonate, isolated body
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fix AC starter unit consisting of one 25 Amp capacity starter, one 240 volt 25 Amp 10 KA SP MCB, one 25 Amp sockets and one 25 Amp plug top prewired of make North west/Anchor/Legrand/complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
S&F LED Flood light fitting 100 watt, with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete making connection with 1.5 Sqmm, 3 core, copper round wire and suitable for mounted on pole with angle iron frame. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed. Note :- Contractor make good the existing PCC foundation / Pillars and the cost will be in the above quoted rate.
Supply and fix junction box [FRP] of size 250x200x100mm complete with 100 Amp AL bus bar, 4 way, fixed on SMC insulator alongwith 01 No MCB SP 06 amps capacity with necessary fixing arrangements by providing MS clamps 2 nos made out of MS flat 25 x 5mm including nut bolts etc complete.
Supply & Laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 Core.
Excavation in trenches/Pits in any type of soil(soft/loose soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete, all as specified & directed .
Returning filling in with the earth obtained from Item No 1 here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified & directed.
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified & directed
M&L for providing old size sub Class 'B' bricks laid perpendicular to the cable abutting each other all as specified and directed by the Engineer-in-charge.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning all as specified & directed
M&L for Boring of holes of 150 mm dia under the Road/hard Standing by horizontal borig method 1 mtr below the surface. All Equipments & Machinery required to carry out the work will be provided by the Contractor (If due to any obstruction during boring, reboring has to be done, the same will be done by the Contractor at his own cost the rates deem to cover the same) including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Boring of holes (manually) under road , hard standing without damaging the surface for 50 mm bore GI Pipe. NOTE:- (i) Depth of hole shall be 1 Metre below the top surface of Road / hard standing. (ii) Pipe shall be measured and paid seperately under respective item of the schedule.
M&L for GI tubing 50 mm dia light grade with all necessary fittings laid in trenches flxed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elect power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 400 Sqmm 3.5 core.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elect power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 300 Sqmm 3.5 core.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 300 KVA.
Supply & fixing and testing of bus-bar chamber outdoor type double door made of 3.15 mm thick factory made sheet of 1.5x1 mtr size with , 4 Nos copper strip bus bar 600 Amps,rating mounted on insulator, including all incomming and out going connections with lugs of suitable size etc. complete. Note : Cable glands should be provided for all incoming /outgoing connections and PCC work for foundation including coted rate.
Supply & fixing in replacement of ON Load change over switch 400 Amps, 4 pole,415 volts , 50 Hz, with enclouser type.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
DEORA ELECTRIC WORKS
Z N Enterprises
M/S Shivam Industries
FRIENDS N FRIENDS
A S ENTERPRISES
Pleiad Complex On
M/s RN Kharwar & Sons
M/S Rakesh Singh
M/S SATISH KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .