Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹27.5 LAccepted-AOC 1897 TS NO 6 5 VELLIANGKATTU RAMASAMY GOWNDER LAY OUT 60 FEET ROAD TIRUPUR | TIRUPPUR | TAMIL NADU | 638051 | ₹27.5 L | L2 | Accepted-AOC BIDDER QUOTED VALUE IS LESS THAN ESTIMATE AMOUNT |
| 2 | L1₹25.1 LRejected-Finance | ₹25.1 L | L1 | Rejected-Finance BIDDER QUOTED ABNOMALLY LOW RATE |
| 3 | L3₹27.5 LRejected-Finance 2 914 A9 8 641 687 | TIRUPPUR | TAMIL NADU | 641687 | ₹27.5 L | L3 | Rejected-Finance BIDDER QUOTED VALUE IS MORE THAN ESTIMATE AMOUNT |
| Sl No | Description | Qty | Unit | A Rajesh Kumar L3 | EVERLASTING CONSTRUCTIONS L1 | SENTHILKUMAR L2 |
|---|---|---|---|---|---|---|
| 1.00 | FULL BORE ELECTROMAGNETIC FLOW METER WITH 5 YEARS WARRANTY Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished. | 1 | 1 No | 1,51,841 ₹1,51,841 | 9,05,000 ₹9,05,000 | 1,51,741 ₹1,51,741 Lowest |
| 2.00 | Installation and Commissioning Charges for STP Alalyzer and ELECTROMAGNETIC FLOW METER and Providing Required 2 Data Connectivity to CPCB & SPCB with 1 year subscription with Data logger hardware device 1 year warranty (internet will be client scope) | 1 | 1 No | 2,27,600 ₹2,27,600 | 3,00,000 ₹3,00,000 | 2,27,400 ₹2,27,400 Lowest |
| 3.00 | The Effluent Water Quality Monitoring (Extractive Type)
Parameters:
Ph, BOD, COD, TSS, FLOW METER.
Specifications:
Cod By Uv Correlation Standard Range: 0-1000 Mg/L, Accuracy: +/-12% Bod By UV Correlation Standard, Range: 0-1000 Mg/L Bod Accuracy: +/- 12% Ph (ion Exchange), Standard Range: 0-14 Ph, Accuracy: +/-2% TSS Standard Range :0-1000mg/l Accuracy: +/-12%
Description:
Supply: 220-240 VAC, 50/60 Hz 40VA, Screen: Color, HMI Size:7" inch Resolution: 800 x 400Pixels, LED Backlight Capacitive Touch Screen, (upto16 Channels) With Date & Time Enclosure: Stainless Steel with Epoxy Coating, IP68 Surge protection Micro controller-based circuit Voltage protection Real time data sampling Acid Dosing Required Friendly Interval Easy to install Rigid body Durable sensors RS485 output 4 to 20mA including packing and Transportation Charges | 1 | 1 No | 19,49,400 ₹19,49,400 | 9,25,000 ₹9,25,000 Lowest | 19,49,200 ₹19,49,200 |
| 4.00Add G.S.T. @ 18% | ||||||
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
25 Feb 2026, 3:00 pmClosed
Commissioner
Tiruppur City Municipal Corporation Office, Tiruppur
Supply and Installation of EMF meter, The Effluent Water Quality Monitoring and Data Connectivity to CPCB and SPCB with 1 year subscription in Kasipalayam STP Site in Ward No 46
2026_MAWS_660161_25
E1 / 6349 / 2025 / Z3
Open Tender
Civil Works - Others
Works
90 days
Tiruppur City Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹56,000
27 Aug 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | FULL BORE ELECTROMAGNETIC FLOW METER WITH 5 YEARS WARRANTY Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished. | 1 | 1 No | - | - |
| 2 | Installation and Commissioning Charges for STP Alalyzer and ELECTROMAGNETIC FLOW METER and Providing Required 2 Data Connectivity to CPCB & SPCB with 1 year subscription with Data logger hardware device 1 year warranty (internet will be client scope) | 1 | 1 No | - | - |
| 3 | The Effluent Water Quality Monitoring (Extractive Type)
Parameters:
Ph, BOD, COD, TSS, FLOW METER.
Specifications:
Cod By Uv Correlation Standard Range: 0-1000 Mg/L, Accuracy: +/-12% Bod By UV Correlation Standard, Range: 0-1000 Mg/L Bod Accuracy: +/- 12% Ph (ion Exchange), Standard Range: 0-14 Ph, Accuracy: +/-2% TSS Standard Range :0-1000mg/l Accuracy: +/-12%
Description:
Supply: 220-240 VAC, 50/60 Hz 40VA, Screen: Color, HMI Size:7" inch Resolution: 800 x 400Pixels, LED Backlight Capacitive Touch Screen, (upto16 Channels) With Date & Time Enclosure: Stainless Steel with Epoxy Coating, IP68 Surge protection Micro controller-based circuit Voltage protection Real time data sampling Acid Dosing Required Friendly Interval Easy to install Rigid body Durable sensors RS485 output 4 to 20mA including packing and Transportation Charges | 1 | 1 No | - | - |
| 4 | Add G.S.T. @ 18% | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.23 MB
BOQ_792705.xls
BOQ • 0.35 MB
25_Conditions.pdf
Tender Documents • 3.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].