Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹1.3 Cr | 1 | Accepted-AOC Being lowest bidder |
| 2 | 2₹2.0 Cr+₹64.9 L (49.7%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹2.0 Cr+₹64.9 L (49.7%) | 2 | Rejected-Finance Being more than L1 |
| 3 | 3₹2.0 Cr+₹70.6 L (54.1%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.0 Cr+₹70.6 L (54.1%) | 3 | Rejected-Finance Being more than L1 |
| 4 | 4₹2.1 Cr+₹78.4 L (60.1%)Rejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹2.1 Cr+₹78.4 L (60.1%) | 4 | Rejected-Finance Being more than L1 |
| 5 | 5₹2.1 Cr+₹81.7 L (62.6%)Rejected-Finance | ₹2.1 Cr+₹81.7 L (62.6%) | 5 | Rejected-Finance Being more than L1 |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
12 Mar 2021, 6:00 pmClosed
Sr DDG and CE
Director General Naval Project (MB) Naval Dockyard SBS Road Mumbai 400023
AUGMENTATION OF MAIN MACHINE SHOP AND PROVISIONING OF OFFICES AT NAVAL DOCKYARD MUMBAI
2021_MES_411393_1
8517_1
Open Tender
Civil Works
Item Rate
540 days
NAVAL DOCKYARD MUMBA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
DGNP Mumbai
₹2.4 L
13 May 2021
19 Jan 2021
19 Mar 2021
19 Jan 2021
12 Mar 2021
26 Feb 2021
Amount
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) all as specified and directed.
Demolition of brick work or stone masonery built in cement mortar complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or Similar pattern in roof coverings all as specified and directed.
Dismantling framed truss having span n.exc 10m all as specified and directed.
Dismantling wrought iron or mild steel work of any description otherwise not provided in any position at purlin, rafter, channel, colomns etc all as specified and directed.
Dismantling structural Steel work including doors, gates but excluding framed truss etc all as specified and directed.
Dismantling timber scantlings 40 Sq. cm and over in section and in any position in unframed work all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulatin boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
Taking down cement plaster from brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
Dismantling floor, hearth or wall tiling including CM bedding (but not backing) as in skirting and rubbish off the premises all as specified and directed.
Taking down chowkats or frames n exc 1.5 Sqm each but without taking off shutters from the frames all as specified and directed.
Taking down chowkats or frames exc 1.5 Sqm but n. exc 4.00 Sqm with shutter( without taking off shutters from the frames) all as specified and directed.
Cement concrete 150mm thick, Type D2, 1:4:8 (40mm graded Aggregate) in foundations, filling of floor and mass concrete complete all as specified and directed.
Cement concrete 40mm thick, Type D1, 1:2:4 (20mm graded Aggregate) in subbase of flooring all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
Dark Shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Rendering 10mm thick in CM 1:4as in backing coat to receive the tiles on fair faces of brick work or concrete surfaces all as specified and directed.
Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
MS work for roof trusses (framed),of grade Fe 410W Gde-E-250 quality 'B' trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed.
Preparation of steel and iron Surfaces of any description, over 10cm in width or girth,not otherwise described and fininshing with two coats of synthetic enamel paint over a coat of red oxide zinc primer all as specified and directed..
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ( Note: The self driven screw shall be of adequate length to drive into complete thickness of purlin/rafter etc and to be provided with one bitumen washer and the gap if any shall be filled with silicon gel to avoid any leakages) all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Plain, black, mild steel 1.25mm thick sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) all as specified and directed.
Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces and making good complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but not exc 20 cm girth complete all as specified and directed.
Expanded metal (weight per Sqm not exc 4kg) cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed.
Hangers 6 mm dia. G.I. (upto 1200mm length) for grid size 605 x 605mm adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Gl frame work (Grid size 605x605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre comlete all as specified and directed.
Seamless calcium silicate ceiling of 12mm thick made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and directed.(Frame work for ceiling shall be measured and paid separately)
Two coats of oil bound distemper on celing board surfaces of any description all as specified and directed.
Preparation of old surface of wall and applying two coats of oil bound distemper over 3 mm wall care putty all as specified and directed.
Preparation of new surface of wall and applying two coats of oil bound distemper over 3 mm wall care putty all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bond distemper over chalk whitening preparatory to distempering all as specified and directed.
Complete removal of existing treatment from old walls and applying two coats of acrylic exterior emulsion paint over a coat of approved primer (all as per instructions and recommendations of manufacturer) including a thin layer of white cement based putty to obtain desired surface to receive new treatment and preparation of surface etc complete all as specified and directed.
Three coat of white wash on ceiling including preparation of new plastered surafce ofwall all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Stone walling of squared rubble, regular, coursed, well bonded, bedded and solidly hearted, built in CM 1:6 all as specified and directed.
Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 all as specified and directed.
Rendering 15mm thick on fair faces in CM 1:6 without using extra cement on brick work or concrete surfaces all as specified and directed.
Rendering 5mm thick on fair faces in CM 1:3 in ceiling, soffits slabs etc to be finished even and smooth (without using extra lime or cement) all as specified and directed.
Rendering 15mm thick on fair faces in CM 1:4 in external surfaces to be finished even and smooth (without using extra lime or cement) all as specified and directed.
Framed MS work of grade Fe.290.Gde-E-165 such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work all as specified and directed.
MS flat iron clamps, hold fasts, plain angle cleats and similar small articles for fixing water tank conforming to Fe-290 Gde-E-165 all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Taking up or down steel tubing of dia 20 mm and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing of dia 15 mm and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Galvanised steel water tubing 25mm bore dia medium grade with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Galvanised steel water tubing 20mm bore dia medium grade with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Galvanised steel water tubing 15mm bore dia medium grade with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Cutting existing steel tubing of size 25 or 32 mm bore of pipes for alterations or additions (Each cut measured) all as specified and directed.
Bib taps, 15mm bore dia chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed.
Wash hand basin, vitrous china ( flat back or angle back type) size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, 15mm bore dia pillar tap and stop valve, cast copper alloy with capstan head, chromium plated, screwed down high pressure with fly nuts, screwed for iron pipe, 32mm bore waste coupling of PTMT (Half threaded, min wt 45gms) 32mm dia of low density polyethylene piples (LPDE) of pressure rating 6kgf/cm2 fixed complete to walls, ceiling or in floors of 1mtr length, PVC connection 15mm size with PTMT nuts of lenght 450mm etc and fixed complete all as specified and as directed.
Soap dish, vitreous China white, approximate size 160x 160x90mm, fixed to plugs with Chromium plated brass screws complete all as specified and directed.
Toilet paper holder white of vitreous china fixed to walls with chromium plated (CP) brass screws all as specified and directed.
Tubular towel rail brass chromium plate , 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Vitrous China Urinals, Half stall type (590x 390x375mm), white complete including proving and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing all around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for dishcharge pipe, 32 mm dia low density polyethylen pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceiling or in floors of 1 mtr length, PVC connections 15mm size with PTMT nuts of length 450mm etc, 15mm bore dia consussive push button taps of cast copper alloy screwed for iron pipe including connection to flushing pipe, 15mm bore dia stop valves, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with fly nuts, screwed for iron pipe, urinal spreader of PTMT any colour for fixin with 15mm dia pipe(Mininimum weight 60 gms) complete all as specified and as directed
Vitrous China Wash down water closet pan (pedestal pattern), white with 'P' Trap, seat and cover, PVC Connections 15mm size with PTMT nust of length 450mm, PVC Valveless syphonic action type flushing cistern, 10 ltrs, low level, white with inlet ball valve, float and handle incl brackets and flush pipe of polythene of low density or PVC 32 mm dia for low level cistern with and including joint between flushing pipe and socket of EWC pan pre-made and concrete all around complete all as specified and directed.
Mild steel stairs (framed) (Fe-290, Grade E-165) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete as per approved design by GE
Exposing the existing loose damage RCC element of thickness varying from 20mm to 50mm by means of hand held electric chisel hammer so as to expose the reinforcement as per the requirement etc as directed by GE including necessary scaffolding/ working platform as per site requirement complete all as specified.
Free flowing, non-shrink, high strength M-55 grade micro concrete for lintel beam / various openings of window/ gate all as specified & directed by Engineer- in-Charge.
Cleaning the RCC element using water jet, wire brush, removing rust scales from the old reinforcement rods and allowing to dry and applying primer on the exposed reinforcement rods as per manufacturers specifications etc including necessary scaffolding/working platform as per site requirement complete all as specifiedand as directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out in hard/dense soil and soil mixed with boulder/stone all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and exc 1.5 m and n.exc 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil and soil mixed with boulder/stone all as specified and directed..
Concrete bed with 100 mm thick PCC 1:3:6 Type C2 using 40mm graded stone aggregate to drain pipes of 150 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested as directed and speicified
Saltglazed stoneware drain pipe of grade 'A quality, 150 mm internal dia of pipe laid in trenches or in floors all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in the soil all as specified and directed.
Removing excavated soil outside MD land /Naval Dockyard Area and depositing where directed at a level n exc. 1.5 m above the starting point all as directed.
Plain Cement concrete 1:2:4 Type B1 using 20mm graded stone aggregate as in coping including weathering, throating, chamfereing and similar works as required all as specified and directed.
Precast cement concrete cover slab with concrete 1:2:4 Type B1 with using 20mm graded stone aggregate set in CM 1:4 as in manhole cover all as specified and directed.
TMT Bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diaall as specified and directed.
TMT Bars of 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 with using 20mm graded stone aggregate, smooth finished, and reforming benching as required (Internal dia of pipe 150mm)
PVC (SWR) pipes of bore dia 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) 110mm bore dia pipe bends complete all as specified and directed.
PVC (SWR) 110mm bore dia pipe branch piece, single (single Y) equal or unequal with oval access complete all as specified and directed.
PVC (SWR) 110mm bore dia pipe reducers complete all as specified and directed.
PVC (SWR) 110mm bore dia pipe vent cowl complete all as specified and directed.
PVC (SWR) pipes of bore dia 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) 75 mm bore dia pipe bends complete all as specified and directed.
PVC (SWR) 75mm bore dia pipe branch piece, single (single Y) equal or unequal with oval access complete all as specified and directed.
PVC (SWR) 110mm bore dia pipe vent cowl complete all as specified and directed.
Collapsible steel gate, double leaves top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified , eracted in position and securing runners with holdfasts and brackets, complete all as specified and directed and as per approved design and make. The specification shall conforming to SSR Part-I all as specified and directed.
Aluminium powder coated frame for doors, windows, ventilators and partition etc. with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Min thickness of powder coating 50 micron)
12mm Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination on one side & other side balancing white lamination, fixed with screws to timber frame work all as specified and directed.
Sheet glass of ordinary quality 4.00 mm thick in panes exc 0.5 Sqm in each pane all as specified and directed.
Sheet glass of ordinary quality 5.50 mm thick in panes exc 0.5 Sqm in each pane all as specified and directed.
Figured glass 4mm, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and directed.
Powder coated of approved colour aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.(Min thickness of powder coating 50 micron)
Aluminium powder coated door shutters, aluminium section minimum weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. (Min thickness of powder coating 50 micron)
Floor door stopper having overall length of cover plate 150 mm of aluminium alloy body and tounge,anodised,with hard drawn steel spring ,fixed in floor complete all as specified and directed.
Aluminium (extruded section) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fix as specified and as directed
100mm, 4 levers brass Mortice Locks verticle type with two keys complete all as specified and directed.
75mm long butt hings medium weight cold rolled mild steel & fixed to chowkats all as specified and directed.
200 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
150mm long Aluminium handles, cast type, anodised all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 300mm long all as specified and directed.
PVC(SWR) floor trap 75mm dia of outlet ,plain with grating including jointing with solvent cement all as specified and directed.
MS work for single stanchions of Fe 410-W, Gde-E-250 quality 'B', built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections all as specified and directed.
20mm thick Granite black colour, tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Preparation of new painted wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed..
Providing Cement Concrete 1:2:4 , Type B0, (12.5mm graded aggregate) including weathering, slightly rounded or chamfered angles and throating, as in coping, cill, plinth courses etc all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning and removing from site complete all as specified and directed.
Cast Iron rainwater socket pipe with cement joint without ears of size 150 mm dia complete all as specified and directed.
Cast Iron rainwater Head, sqaure type, flat complete of size 150 mm dia complete all as specified and directed.
Cast Iron rainwater Bends or elbows, sqaure or obtuse complete of size 150 mm dia complete all as specified and directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 20 mm bore dia of size 150 mm dia complete all as specified and directed.
Gun-metal 20mm bore dia, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Fillet work in 2nd class Hardwood, plain fillets, square, rectangular or triangular in section n exc 3 sqcm fixed with screws complete all as specified and directed.
Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing of solid PVC wall lining at SSR Part-I and Part-II complete all as specified and directed.
5mm thick printed PVC colour sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site all as specified and directed.
5.5 mm thick tinted glass fixed with necessary rubber gasket and aluminium beading complete all as specified and directed.
12 mm thick tinted glass fixed with necessary rubber gasket and aluminium beading complete aall as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC colour sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing at SSR Part-I and Part-II complete all as specified and directed.
Factory made solid panel PVC door shutter,30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing at SSR Part-I and Part-II
2nd class hardwood, 40 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
30mm thick 2nd class hardwood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed.
MS rolled mild steel in Plates (Fe 410W, GdeE-250 quality -A)plain or chequered) chamfered, square cut or notched(ordinary & counter sunk) forming holes with riveted, bolted or welded attachment all as specified and directed.
2nd class hard wood, plain straight, solid chawkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed all as specified and directed.
2nd class Hardwood Glazed and skelton shutters,30 mm thick in window, vintilators open rebeted and prepared to receive glass, gauze, etc with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for scuring glass etc; Sizes of members of shutters as specified in SSR Part - I, Section 8, clause 8.20 (a).
Formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etcall as specified and directed.
Cement concrete mix (M-20) using 20mm graded stone aggregate as in lintel beam complete all as specified and are directed
Rolled Mild Steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates complete (Fe 410W Gde-E-250 quality 'A' ) all as specified and directed.
Steel work in tubular trusses, pipes of noimnal bore dia 65mm (having min wt 6.53kg/mtr) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and directed.
Timber scantling of Second class clean sawn hard-wood and fixed in any position complete all as specified and directed.
Weather boarding of 2nd class hardwood clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed complete all as specified and directed.
Internal Electrifications:- Taking down carefully copper/aluminium submain and point wiring (light,fan,socket or power) complete, with fittings such as switches,ceiling roses,pendants,regulators,sockets etc. for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc all as specified and directed.
Taking down carefully unservicable fan/air circulators complete, for handing over to users as directed
Point wiring one light point controlled by one switch with 1100 Volt grade single core, ISI marked with IS : 694 PVC insulated unsheathed 1.5 Sq mm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated unsheathed (color coding of wires shall be for Phase, neutral and earth wire in PVC casing caping including necessary accessories and PVC terminal boxes modular type 3 mm thick sheet cover fixed complete all as specified and directed .
All as per Sl Item No 134 above but for one fan point controlled one switch.
All as per Sl Item No134 above but for one call bell controlled by one bell push
All as per Sl Item No134 above but for one light point controlled by two two way switches
All as per Sl Item No 134 above but for one 6A switch socket on independent board
Point wiring for one 6A socket on same board, controlled by one switch with 1100 Volt grade single core, ISI marked with IS : 694 PVC insulated unsheathed 1.5 Sq mm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated unsheathed (color coding of wires shall be for Phase, neutral and earth wire in casing caping including all fittings and necessary accessories all as specified and as directed.
Point wiring for one 16A switch socket combination on independent board, controlled by one switch with 1100 Volt grade single core, ISI marked with IS : 694 PVC insulated unsheathed 2.5 Sq mm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 2.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated unsheathed (color coding of wires shall be for Phase, neutral and earth wire all as specified) in casing caping including necessary accessories and PVC terminal boxes modular type 3 mmthick sheet cover fixed complete all as specified and as directed.
Modular switch 1 way 6A, 1 module complete all as specified and as directed.
Modular switch 2 way 6A, 1 module complete all as specified and as directed.
Bell push modular, 6 Amp, single pole, one way 230V with white cover plate with frame complete all as specified and as directed.
Ding Dong bell AC 230 volts single pole 50 Hz complete all as specified and as directed
Ceiling rose, 3 terminal 230 Volt AC single phase polycarbonate, isolated body ISI marked complete all as specified and as directed.
Ceiling fan five star rating with double ball bearing, 350 rpm, 1200mm sweep 140-285 volts, AC, 50Hz pf 0.99 with super energy efficient BLDC motor alongwith down rod, canopy and all accessopries, along with smart remote controlled, all as supllied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 volts grade of suitble size not less than 1.5 sqmm and suitable length including and making, necessary electric connection etc all as directed. NOTE: Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 3 years for any defects developed during the period.
Modular switch socket outlet 6 Amps 3 pin combined shuttered ISI marked with IS:1293 having finger proof terminals with captive screws having front fixing and removing features without removing plates complete all as specified and as directed.
Modular switch socket combination 16 Amps 6 pin combined shattered ISI marked with IS:1293 having finger proof terminals with captive screws having front fixing and removing features without removing plates complete all as specified and as directed.
LED 36 watt surface mounted 2'x2' light fitting with diffused acrylic cover with all accessories having High lumen output, driver PF >0.98, having over voltage protection upto 400volts, surge protection level 7-10kv, thermal short circuit protection THD <10%, made up of long life LED chips(SMD) in modular with Ra >70 and LED lumen efficiency >120 lumen per watt, and connected with surface mounted square Backelite panel 2 x 2 LED luminaire with diffuser,including 3 core flexible copper cable PVC insulated of size 1.5 Sqmm complete all as directed .Model No BZSSQL 36W LED WH of Bajaj make or equivalent in other make. Note:The firm has to give warranty for light fitting including driver minimum for 2 years for any defects developed during the period.
LED 18 watt surface mounted 1'x1' light fitting with diffused acrylic cover with all accessories having High lumen output, driver PF >0.98, having over voltage protection upto 400volts, surge protection level 7-10kv, thermal short circuit protection THD <10%, made up of long life LED chips(SMD) in modular with Ra >70 and LED lumen efficiency >120 lumen per watt, and connected with surface mounted square Backelite panel 2 x 2 LED luminaire with diffuser,including 3 core flexible copper cable PVC insulated of size 1.5 Sqmm complete all as directed.Model No BZSSQL18 W WH of Bajaj make or equivalent in other make. Note:The firm has to give warranty for light fitting including driver minimum for 2 years for any defects developed during the period.
BATTEN LED Luminiare, 10 Watt, with all accessories having polymer extruded channel with diffuser for glare free light, High lumen output, driver PF >0.98, having over voltage protection upto 400volts, surge protection level 7-10kv, thermal short circuit protection THD <10%, made up of long life LED chips(SMD) in modular with Ra >70 and LED lumen efficiency >120 lumen per watt, internally pre-wired including PVC insulated three core flexible copper conductor 1.5 sq mm drawn through flexible pipe connecting with ceiling rose all as directed.Model No BCLSB 10WH of Bajaj make or equivalent in other make. Note:The firm has to give warranty for light fitting including driver minimum for 2 years for any defects developed during the period.
Sheet metal MCB DB SPN 8 way,240 V, double door type powder coated with 200 Amps copper bus bar, neutral link, earth rail and din rail ISI marked,for fixing MCB/MCCB complete all as directed. Note :- (i) MCBs , Isolator, RCOBs/RCCBs, ELCBs measured & paid for separately under respective items. (ii) MCBs, Isolator, RCOBs/RCCBs, ELCBs shall be of same make.
MCB, SP, 6-32 Amps,10 KA 'C' Curve, 230 volts, 50 Hz, ISI marked complete all as specified and as directed.
Sub main wiring with 2 run,single core, 4 sq mm nominal area with 1100 Volt grade ISI marked with IS 694, PVC insulated unsheathed with one run of 4 sqmm multi stranded copper conductor cable (FRLSH) for continuous earth wire drawn in and including PVC casing caping. complete all as specified and as directed. Note : Two runs of cable and one run of earth cable in PVC Casing caping shall be measured as one length.
Sheet metal MCCB DB TPN 4 way 415 V ,vertical double door type powder coated with 200 Amps copper bus bar, neutral link, earth rail and din rail ISI marked. complete all as directed. Note :- (i) MCBs , Isolator, RCOBs/RCCBs, ELCBs measured & paid for separately under respective items. (ii) MCBs, Isolator, RCOBs/RCCBs, ELCBs shall be of same make
MCCB 4 pole 40 Amps, Icu=Ics=16 KA (with adjustable thermal and magnetic release), 415 volts, 50 Hz, ISI marked complete all as directed.
MCB SPN, 6-32 Amps 240 volts AC ,"C" curve,10 KA 50 Hz all as specified and as directed.
GI hot dip perforated cable tray of size 200mmX50mm not exceeding total sheet width as per site requirement made out of not less than 2mm thick GI sheet including MS clamps made out of 25x3mm flat at an interval of every 01 Mtrs including GI bolts nuts washers etc all as specified and as directed.
PIR ceiling detector sensor with 180°-360° detection angle, IP 20- IP55 all as specified and as directed.
Cable 3 core 2.5 sqmm copper conductor cable with multistrand 11/.3mm confirming to IS 8130/1994 class 5 PVC FRLSH insulated along wall/roof/cabletray etc surface type (for light sensor) all as specified and as directed.
Exhaust fan 250mm sweep 230V 50 Hz complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
Air circulator fan 450mm sweep 230V 50 Hz complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requied 4 mm dia galvanised iron or steel wire all as specified and as directed.
Fire Alarm System:- Detectors Complying with and type certified to EN - 54 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence. Detectors with housings shall be moulded in pure white self-extinguishing polycarbonate. Detectors will be unobtrusive when installed as specified or indicated including testing on completion all as specified and as directed.
Addressable manual call point resettable type, Each MCP installed on the loop shall have a unique address, set at the commissioning stage. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion all as specified and as directed.
Addressable loop powered sounder strobe, Dual tone hooter electronic type and shall give discontinuous/intermittent audible alarm automatically when ever smoke detector or heat detector operates complete with magnetic coil ( sound coil ) and accessories, ready for mounting ( fixing ). The hooter shall also have facilities for speaker announcement. Hooter shall also have the capability for adjusting the sound output. Hooter casing shall be fabricated from 16 gauge MS sheet stove enameled to smooth finish. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion all as specified and as directed.
Short circuit Isolators complete in all respect as specified or indicated including testing on completion all as specified and as directed.
Remote response indicators, housed in a 16-gauge aluminium casing. It shall glow clearly incase the detector to which it is connected gives an alarm signal. The word "FIRE" shall be clearly written on the visible face of the box. It shall have two numbers of red LED to compensate for fusing of either LED complete in all respect as specified or indicated including testing on completion.
Addressable control module Complete in all respect as specified or indicated including testing on completion.
Cable 2 core 1.5 sqmm armored copper conductor cable with multistrand 11/.3mm confirming to IS 8130/1994 class 5 PVC FRLSH insulated along wall/roof/cabletray etc surface type all as specified and as directed.
DCP fire extinguisher, 6 Kg, ISI marked with stored pressure, handheld, floor mounted type suitable for class ABC fire ISI marked with IS:15683 complete with refill, full length back bracket, hose and clip complete all as specified and as directed.
Carbon-di-Oxide fire extinguisher ISI marked of capacity 6.5 Kilogram consisting of welded mild steel cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 300mm long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked with IS:15683, finishing externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners with internal charge, complete all as specified and as directed.
MS structural fabricated section made out of MS angel/tubing/flat including painting with 2 coats of synthetic enamel paint over one coat of red oxide for holding fire extinguishers complete all as specified and directed
Air Conditioning:- Suppy,installation,testing and commissioning of variable refrigerant volume/Variable refrigent flow air -conditioning outdoor units 24.00 HP suitable for cooling,compressors complete with inverter based scroll compressors,precoated fin type heat exchanger,low noise,condenser fans,GI coated condenser stands,microprocessor panel with sequential starting of condensing units,coils,expansion valves,filters,single phase preventer,complete with controllewr & with accessories & subassemblies fittings etc. full charging of R-410 A refrigerant gas complete,powder coating complete as per specifications,vibration isolator& necessary accessories all as specified and directed.
Hiwall Type 1.3 TR indoor units includes washable prefilter,fan section,DX-coil section etc with cordless remote controller complete all as specified and directed
Hiwall Type 1.7 TR indoor units includes washable prefilter,fan section,DX-coil section etc with cordless remote controller complete all as specified and directed
Hiwall Type 2.0 TR indoor units includes washable prefilter,fan section,DX-coil section etc with cordless remote controller complete all as specified and directed
Group controller is touch screen based user friendly ,upto 16IDU and 3 systems can be controlled and parameters of individual indoor units can be set all as specified and directed (Central Control Monitor For Entire System)
Special refrigent 'Y' joints/Refnets for VRV/VRF system as per standard specifications all as specified and directed
Air refrigerant piping of size 6.4 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 9.5 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 12.7mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 15.9 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 19.1 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 22.2 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Air refrigerant piping of size 28.6 mm O.D.(insulation :19/13 mm thick)(Suction/Liquid) between indoor & outdoor units using eddy current free Copper pipes and fittings like elbows, couplers,tee joints,brass fittings.Supports Consisting of GI box/ "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 2 metre each, insulation Suction /liquid pipes using 19/13 mm thick elastpmeric closed cell Nitrile Rubber insulation material & having class"O" for fire properties ,structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports.
Rigid PVC drain pipe of size 25 mm Dia , 2 Kg /cm2 rating with insulated with 6 mm nitrile foam rubber trenched on walls,ceiling suspended ,hanged ,hanged with all necessary clamps,saddles & support all as specified and directed.
Rigid PVC drain pipe of size 32 mm Dia , 2 Kg /cm2 rating with insulated with 6 mm nitrile foam rubber trenched on walls,ceiling suspended ,hanged ,hanged with all necessary clamps,saddles & support.
First charge of R407c/R-410A refrigerant and oil for the complete.
GI Slotted C Channel of size 40 x 1.5 mm for pipes and cables horizontally and vertically along with threaded rod,nut,bolt,saddle ,tie etc complete all as specified & directed.
Sheet metal enclosure with socket and plug and MCB single pole and neutral with a two pin and earth plug and socket ISI maked complete with one MCB SP 20A, 240 V AC complete all as specified and as directed.
PVC Insulated cable copper conductor 1100 Volts grade 3 Core flexible 2.5 sq mm confirming to IS-694 laid surface/ recessed Pipe /fixed on wall etc as required at site complete all as specified and directed by Engr-In-Charge.
PVC Insulated cable copper conductor 1100 Volts grade 3 Core flexible 6.0 sq mm confirming to IS-694 laid surface/ recessed Pipe /fixed on wall etc as required at site complete all as specified and directed by Engr-In-Charge.
PVC Insulated cable copper conductor 1100 Volts grade 2 Core flexible 1.0 sq mm confirming to IS-694 laid surface/ recessed Pipe /fixed on wall etc as required at site complete all as specified and directed by Engr-In-Charge.
Non metallic PVC conduit medium grade of size 20 mm incuding of all bendss, elbows, reduces,bell mounth tube ends and couplers,locknuts,saddles ,locknuts, pipe hook etc. for laying of 3 core flexible cable etc omplete all as specified and directed by Engr-In-Charge.
Non metallic PVC conduit medium grade of size 25 mm incuding of all bendss, elbows, reduces,bell mounth tube ends and couplers,locknuts,saddles ,locknuts, pipe hook etc. for laying of 3 core flexible cable etc omplete all as specified and directed by Engr-In-Charge.
Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole 63 Amp MCB complete all as specified and directed.
Sheet metal MCB DB SPN 8 way 240 volts, double door type powder coated with 200 Amps rated copper bus bar , neutral link, earth rail & din rail, ISI marked for fixing of MCBs , Isolator, RCOBs/RCCBs, ELCBs etc complete. Note : (i) MCBs , Isolator, RCOBs/RCCBs, ELCBs measured & paid for separately under respective items. (ii) MCBs, Isolator, RCOBs/RCCBs, ELCBs shall be of uniform make.
MCB SP 6 to 20A, ‘C’ curve breaking capacity 10KA, 240 Volts with ISI marked with cable connection and copper lugs complete all as specified and directed.
MCB SPN 32A, ‘C’ curve breaking capacity 10KA, 240 Volts with ISI marked with cable connection and copper lugs complete all as specified and directed.
Factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted,415 volts,3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts forwith and including following:- (i)BUSBAR CHAMBER: Electrically grade copper shrouded bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators.
OUTGOING a. MCCB 4P 63 Amps, 415 volts, 50Hz, 16 KA( Ics = 100%Icu) of Quantity-02 No s (Adjustable Thermal & Magnetic type) complete all as specified and directed (b). MCB SPN 32A, 25 KA,50 Hz, C curve with ISI marked complete with all accessories. - 01 No (c ) MCB SPN 32A, 16 KA,50 Hz, C curve with ISI marked complete with all accessories. - 03 Nos (FOR indoor DB )
Notes:-1. Panel manufacturers should have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes: degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing /passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. 3. Pre dispatch inspection shall be carried out by the authorized rep of accepting officer. in case of any deviation from approved drawing, the same will be rejected and fresh LT panel has to be fabricated by the manufacturer. Testing shall be done at ufacturer's premises and all routine test like IR and continuity tests shall be performed/recorded in presence of authorized rep of Accepting officer. 4. The panel manufacturer should have following certification: (i) CPRI certification Degree of protection IP-54 should be in accordance to IEC:61439 as applicable (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A 5. MCCB/ACBs provided should be capable for on line setting of the current. 6. ACBs provided should be capable for on line setting to the time delay. 7. All the electrical switch gear like MCCBs, MCBs and ACBs should be of same make. 8. All incomer ACBs and MCCBs should have provision of capability with SCADA through communication port for monitoring purpose only. 9. Drawing of panel board should be got approved from GE before fabrication. 10. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Earthing complete with Galvanized steel pipe electrode, 40 mm bore, medium grade ,2.5 m length buried directly and preferably vertically in ground with top edge not less than 1.25m below ground level connected with GI strip of size 25 X 4 mm as eathing lead by means of bolts, nut & check nuts and washers thimbles, including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, with fair finish,internal surface of concrete chamber shall be given internal size 300mm x 300 mm ,15 mm thick plaster in CM 1:4,funnel with wire mesh ,RCC pit cover of 320 x 320 x 80 mm size (1:2:4) Type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all as shown in electrical plate No 2 of MES SSR Part -1 (2009) and specified including and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 15 mm bore, medium grade ,including all excavation in any type of strata and earth work and connecting the earthing strip to an earthing test point/panel including testing on completion complete all as specified and directed. by Engr-In-Charge. (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover. (2) Cost of additional GI strip more than 7.5 meter will be measured and paid seperately under relevant item
Earth continuity connductor or main earthing lead of size 25x4mm GI strip fixed on wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated or situation etc.duly scrwed/saddled as required.at ste and connecting up complete all as specified and as diredted.
Electric Supply : Dismanling of existing old unserviceable panel complete including accessorie etc andhanding over over to user all as sirected.
Factory made, LT panel board Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, fuly compartmentalized,front openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLS cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for grouting, PCC foundation etc with and including following:-
Factory made, LT panel board Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, fuly compartmentalized,front openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLS cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for grouting, PCC foundation etc with and including following:-
Notes for Sl Item No 205&206:_ 1. Panel manufacturers should have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes: degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing /passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. 3. Pre dispatch inspection shall be carried out by the authorized rep of accepting officer. in case of any deviation from approved drawing, the same will be rejected and fresh LT panel has to be fabricated by the manufacturer. Testing shall be done at ufacturer's premises and all routine test like IR and continuity tests shall be performed/recorded in presence of authorized rep of Accepting officer. 4. The panel manufacturer should have following certification: (i) CPRI certification Degree of protection IP-54 should be in accordance to IEC:61439 as applicable (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A 5. MCCB/ACBs provided should be capable for on line setting of the current. 6. ACBs provided should be capable for on line setting to the time delay. 7. All the electrical switch gear like MCCBs, MCBs and ACBs should be of same make. 8. All incomer ACBs and MCCBs should have provision of capability with SCADA through communication port for monitoring purpose only. 9. Drawing of panel board should be got approved from GE before fabrication. 10. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured,electric power cable (heavy duty) of size 3.5 Core 120 Sqmm , 1100 Volts grade with stranded copper conductor , confirming to IS-7098(part-II) laid in cable trenches/Duct/Wall/surfaces/Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and directed
XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured,electric power cable (heavy duty) of size 3.5 Core 95Sqmm , 1100 Volts grade with stranded copper conductor , confirming to IS-7098(part-II) laid in cable trenches/Duct/Wall/surfaces/Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and directed
XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured,electric power cable (heavy duty) of size 3.5 Core 25Sqmm , 1100 Volts grade with stranded copper conductor , confirming to IS-7098(part-II) laid in cable trenches/Duct/Wall/surfaces/Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and directed
Supply,installation,commissioning & testing of advance encapsuated compound based CPRI tested maintenance free ,pipe in-pipe technology upgraded (Zinc &alloy ) ,Zinc coated (80-100) microns with pure Zinc (99.9%)&alloy coating (200-250) microns.Earthing system confirming to IS 3034.Outer and inner pipe shall be be 41.09 mm dia & 26.4 mm dia and 2.00 meter in length,zinc coated with additrional special alloy coating 300 mm on the top side for additional protection of the terminal.Annular space between the pipes being filled up with compact fill (CF) (crystalline Conductive Compound ).The Compact Fill (CF) mixure which is machine pressed in the pipes shall not be disintegrated or collapse when poutrt pipe corrodes .The inner pipe shall be extended with terminals for connectivity the job includes digging the pits and refilling the same by Electrodite/Conductolite Back Fill compound (Ground Enhancer), the BFC should be ecofriendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 Bags (as per soil condition) extra per pit/ unit. The material should have good electrical condutivity & anti corrosion property in wide range of soil conditions complete work must be executed all as per manufacturer's instruction. Make "ASHOK"Model-ASEEL-19, 2m length (ZC & AC) or equivalent (All the above given dimensions may vary ± 1MM) Note:- The quantity of BFC "Electrodite shall be acheve the earth value less than 1Ω
GI earth strip 25x4mm thick for extending earth continuity, buried in ground or drawn in pipe or any other indicated situation etc.
Total
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .