| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 0 RUPSINGH JOTE BAGDOGRA DARJEELING WEST BENGAL 734014 UDYAM WB 06 0007631 | DARJEELING | WEST BENGAL | 734014 | L1 | Accepted-AOC Bidder is L1. Recommended for award of contract and approved by the competent authority. | |
| 2 | Rejected-Technical AT JAWAHAR NAGAR PO BERMO DIST BOKARO PIN 829104 JHARKHAND | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical L-2 BIDDER. DOCUMENTS NOT EVALUATED. BID REJECTED | |
| 3 | Rejected-Technical | - | Rejected-Technical L-3 BIDDER. DOCUMENTS NOT EVALUATED. BID REJECTED |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
1 Mar 2024, 11:00 amClosed
P E EnM, Bokaro OCP
PO office, Bokaro colliery
Electrical repair and maintenance of different blocks/departments chambers and rooms located in DD mines area and one portion of area account office, 01 no minus type quarter at 3 nos colony and providing and fixing service wire for shiv mandir and f
2024_CCL_302546_7
CCL/BnK/Bokaro/EnM /23-24/26
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
bokaro colliery
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,500
29 Nov 2024
24 Feb 2024
2 Mar 2024
24 Feb 2024
1 Mar 2024
24 Feb 2024
24 Feb 2024 - 26 Feb 2024
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group A)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required - Single pole and neutral
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supply and fixing of 9 W LED bulb
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply of minimum inverter type 20 Watt LED Tube light with minimum backup time of 4 hours of standard make
Supply and providing of 63 Amp RCCB of sensitivity 30mA
Supply & providing of 6 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity
Supplying and drawing 2x2.5 sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing 2 x 4 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and fixing of 32mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Fitting & fixing charges of Item No 9,10 & 11, Labour cost @ 10% of the estimated value of Sl. No. 9,10 & 11
Total impact of GST for the purpose of CTC
M/S JAI MAA ENTERPRISES
S KUMAR ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .