GEMC-511687740884682
Awarded to KRISH BIOMEDICALS
₹1.6 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Semiautomated Biochemistry Analyzer | KRISH BIOMEDICALS, Model: SA-5000 | - | 2 NOS | ₹79,000 | 158,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LQualified Make: NA
Model: KRISH BIOMEDICALS, Model: SA-5000 I P EXTENSION DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: NA
Model: KRISH BIOMEDICALS, Model: SA-5000 | L1 | Qualified MSE |
Tender Value
Refer Docs
EMD Value
₹5,960
Closing Date
4 Jun 2018, 3:00 pmClosed
PORTABLE MOBILE LAB -WITH POWER BACKUP PORTABLE MOBILE LAB -WITH POWER BACKUP ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type of Portable mobile Lab Windows based user friendly interface 7.0 inch touch screen LCD Auto sleep for lamp protection
self-defined stand by time 5 USB port
Ethernet port for LIS Up to 300 tests can be programmed Up to 2
00
000 result storage Online Reaction Curve Database backup by USB port Can attach external Key Board and Mouse Universal power supply - Case or Mobile carrying platform specification NA - Accessories & spares including in standard pack YES - Capacity of stands and number of stands provided for blood centrifuge tubes NA - Cuveettes stand provided false 1/8 Number of Cuvettes provided 0 - material of the Stand NA - warranty on Product 1 Power back up Duration (HOURS) 0.5 Power Back up Facility Provided Yes - Product code available on supplier website false - Incubation unit provided false Microtips provided false Free Service Available true Number of Free Services 3 Power Supply for Incubation Unit NA - Number of investigation the kit can perform 100 Power Supply for Bio Chemistry Analyser (VDC
Hz) Voltage: 100 – 240 Vac
Frequency: 50 – 60 Hz - Power Supply for Centrifugation Unit (VAC) NA - Microtip box provided false Micropipettes provided false Reagents Containers provided false - Supply of free spare parts under warranty true - Cuvettes provided false Blood Centrifuge Tube Stand provided false - Number of Centrifugation units provided in the kit 1 Centrifugation unit Provided false Blood Centrifuge Tube false - 2/8 provided Bio-Chemistry Analyzer provided true Capacity of Stands and Number of Stands provided NA - Number of units of Bio Chemistry analyzer provided with Kit 1 1
2
0 Capacity of Cuvettes (ml) 0 - Sample system capacity and Volume required in the Centrifuge unit NA - Number of Incubation Units provided with the Kit 1 - Portable Fridge/Cold Storage for maintaining reagents at 2 to 8 degree C false Microscope Provided false Portable PC based ECG 12 lead provided false Portable Tri- Foldable BMI (Body Mass Index) with bluetooth app
battery operated with Carry Bag false External Battery Packs false Satellite Control Application provided for Data Collection and to access location false FUNCTIONAL FEATURES Weather Kit Performs Serology Test- Widal
IgM
Maleria Antigen
Dengue NS1 Antigen
HBSAG
HCV
VDRL
RA Factor
CRP
Pregnancy (UPT)
false 3/8 Semen Analysis
Semen Fructose Weather Kit performs Lipid Profile test- HDL
LDL
VLDL
Tri glyceride
HDL/LDL Ratio
Cholestrol HDL ratio
Cholestrol
CK_MB true Weather Kit performs Liver Function Test- Albumin Test
Alkaline Phosphate
Direct Bilurubin
Indirect Bilurubin
Total Biliurubin
AST (SGOT)
ALT (SGPT)
Total Protein
Gloublin
Albumin/Gloublin Ratio
ALP true Weather Kit Performs Urine Test- Leukocyte
Nitrite
Bilinogen
Protein
PH
Blood
Specific Gravity
Ketone
Biliurubin
Glucose
Appearance
Color
Reaction
Quantity
Bacteria false Weather Kits perform Hematology Test- Hemoglobin
RBC
PCV
MCV
MCH
MCHC false Weather Kit performs Electrolytes Test- Sodium
Potassium
Chloride
Phosphorus
Calcium
Magnesium true Weather Kit perform Sugar (Glucose) test- Fasting
random
PP true Weather kit perform Kidney Function Test- Creatanine
Urea
Uric Acid
BUN
EGFR true 4/8 Weather kit perform Body Mass Index Test false TECHNICAL FEATURES Sample System Capacity & Volume required in the Analyzer 350 Micro Litter - Type of Charging Facility External Charging External Charging
Solar Power Cell
Solar Power & Battery (Both) Type of Data logging option 4 USB Slave
1 USB host
1 Ethernet Port for LIS - Technical Specification of the Centrifugation Unit provided NA - Data Recorder/Mini Laptop provided false Details of Patient Data Management Software LIS - Technical Specification of Bio-Chemistry Analyzer provided Analysis Methods End Point
Kinetics
Fix time (2 Point Kinetic)
2 Point End
Turbidity
Absorbance Calibration Type 1- Point Linear (Factor)
2- Point Linear
Multi-Standard (Linear & non-Linear)
Logit Log (3P/4P/5P)
Exponential
Spline & Parabola Wave Length 340
405
450
505
546
578
630nm; 2 extra spaces for optional filters Light source 6V/10W Halogen Lamp Photometric range 0.0000 - 3.0000 Abs Abs. Resolution 0.0001 Abs Stability < 0.005 Abs/hour Carry Over < 0.5% Flow Cell Volume 32 µL Cuvette Mode Yes
available. Flow Cell Temperature Control Peltier controlled: RT
25⁰ C
30⁰ C
and 37⁰ C Test Parameter Programmable 300 Programs Test Result Storage 2
000 - 5/8 Results Display & Input 7″ Color LCD with Touch screen operation. Virtual Keyboard incorporated for input External Mouse External USB Mouse attachable External Keyboard External USB Keyboard attachable Printer Built- in thermal Printer Supports External USB Printer PCL 3 GUI Language Communication Interface 4 USB slave; 1 USB Host and 1 Ethernet Port for LIS Q.C. Full QC Programme with L-J Curve Aspiration Peristaltic Pump with minimum Aspiration 200 μl to 1000 μl Power requirement Wide range power supply: AC 100 - 240V
50/60HZ Ambient temperature 15°C~35°C
with fluctuation less than ±2°C/H Relative humidity 35%RH - 80%RH
without condensation. Dimension 400(L) X 300(W) X 160(H)mm Weight 6.0 kg technical Specification of Incubation Unit provided NA - Additional Safety Features Fuge - Patient Data Management software provided false External Dimensions of the Mobile Lab (the case): (Height X Width X Width) (mm X mm X mm) 400x300x160 - Operating and reading method of Analyzer True Rendom acess with Direct reading System - 6/8 CERTIFICATIONS & REPORTS Firm Certified to ISO9001:2008 or latest yes - Product is CE Certified false - Certification of Incubation Unit Yes - Certification of Bio Chemistry Analyzer Yes - Certification of Centrifugation Unit Yes - Certification for ISO 13485 Yes - Submission of all the Certificates to the buyer along with supplies on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sugarajan Thangavel 628004
V.O.CHIDAMBARANA R PORT TRUST ADMIN OFFICE TUTICORIN 628004 2 15 EMD Advisory Bank HDFC Bank EMD Percentage(%) 2.00 EMD Amount 5960 ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 14
97581
GEM/2018/B/13923
GeM Contract
PORTABLE MOBILE LAB -WITH POWER BACKUP
GeM Contract
15 days
Tamil Nadu; Tuticorin
PRODUCT
Awarded to KRISH BIOMEDICALS
₹1.6 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Semiautomated Biochemistry Analyzer | KRISH BIOMEDICALS, Model: SA-5000 | - | 2 NOS | ₹79,000 | 158,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| PORTABLE MOBILE LAB -WITH POWER BACKUP PORTABLE MOBILE LAB -WITH POWER BACKUP ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type of Portable mobile Lab Windows based user friendly interface 7.0 inch touch screen LCD Auto sleep for lamp protection | - | - | - |
| self-defined stand by time 5 USB port | - | - | - |
| Ethernet port for LIS Up to 300 tests can be programmed Up to 2 | - | - | - |
| 00 | - | - | - |
| 000 result storage Online Reaction Curve Database backup by USB port Can attach external Key Board and Mouse Universal power supply - Case or Mobile carrying platform specification NA - Accessories & spares including in standard pack YES - Capacity of stands and number of stands provided for blood centrifuge tubes NA - Cuveettes stand provided false 1/8 Number of Cuvettes provided 0 - material of the Stand NA - warranty on Product 1 Power back up Duration (HOURS) 0.5 Power Back up Facility Provided Yes - Product code available on supplier website false - Incubation unit provided false Microtips provided false Free Service Available true Number of Free Services 3 Power Supply for Incubation Unit NA - Number of investigation the kit can perform 100 Power Supply for Bio Chemistry Analyser (VDC | - | - | - |
| Hz) Voltage: 100 – 240 Vac | - | - | - |
| Frequency: 50 – 60 Hz - Power Supply for Centrifugation Unit (VAC) NA - Microtip box provided false Micropipettes provided false Reagents Containers provided false - Supply of free spare parts under warranty true - Cuvettes provided false Blood Centrifuge Tube Stand provided false - Number of Centrifugation units provided in the kit 1 Centrifugation unit Provided false Blood Centrifuge Tube false - 2/8 provided Bio-Chemistry Analyzer provided true Capacity of Stands and Number of Stands provided NA - Number of units of Bio Chemistry analyzer provided with Kit 1 1 | - | - | - |
| 2 | - | - | - |
| 0 Capacity of Cuvettes (ml) 0 - Sample system capacity and Volume required in the Centrifuge unit NA - Number of Incubation Units provided with the Kit 1 - Portable Fridge/Cold Storage for maintaining reagents at 2 to 8 degree C false Microscope Provided false Portable PC based ECG 12 lead provided false Portable Tri- Foldable BMI (Body Mass Index) with bluetooth app | - | - | - |
| battery operated with Carry Bag false External Battery Packs false Satellite Control Application provided for Data Collection and to access location false FUNCTIONAL FEATURES Weather Kit Performs Serology Test- Widal | - | - | - |
| IgM | - | - | - |
| Maleria Antigen | - | - | - |
| Dengue NS1 Antigen | - | - | - |
| HBSAG | - | - | - |
| HCV | - | - | - |
| VDRL | - | - | - |
| RA Factor | - | - | - |
| CRP | - | - | - |
| Pregnancy (UPT) | - | - | - |
| false 3/8 Semen Analysis | - | - | - |
| Semen Fructose Weather Kit performs Lipid Profile test- HDL | - | - | - |
| LDL | - | - | - |
| VLDL | - | - | - |
| Tri glyceride | - | - | - |
| HDL/LDL Ratio | - | - | - |
| Cholestrol HDL ratio | - | - | - |
| Cholestrol | - | - | - |
| CK_MB true Weather Kit performs Liver Function Test- Albumin Test | - | - | - |
| Alkaline Phosphate | - | - | - |
| Direct Bilurubin | - | - | - |
| Indirect Bilurubin | - | - | - |
| Total Biliurubin | - | - | - |
| AST (SGOT) | - | - | - |
| ALT (SGPT) | - | - | - |
| Total Protein | - | - | - |
| Gloublin | - | - | - |
| Albumin/Gloublin Ratio | - | - | - |
| ALP true Weather Kit Performs Urine Test- Leukocyte | - | - | - |
| Nitrite | - | - | - |
| Bilinogen | - | - | - |
| Protein | - | - | - |
| PH | - | - | - |
| Blood | - | - | - |
| Specific Gravity | - | - | - |
| Ketone | - | - | - |
| Biliurubin | - | - | - |
| Glucose | - | - | - |
| Appearance | - | - | - |
| Color | - | - | - |
| Reaction | - | - | - |
| Quantity | - | - | - |
| Bacteria false Weather Kits perform Hematology Test- Hemoglobin | - | - | - |
| RBC | - | - | - |
| PCV | - | - | - |
| MCV | - | - | - |
| MCH | - | - | - |
| MCHC false Weather Kit performs Electrolytes Test- Sodium | - | - | - |
| Potassium | - | - | - |
| Chloride | - | - | - |
| Phosphorus | - | - | - |
| Calcium | - | - | - |
| Magnesium true Weather Kit perform Sugar (Glucose) test- Fasting | - | - | - |
| random | - | - | - |
| PP true Weather kit perform Kidney Function Test- Creatanine | - | - | - |
| Urea | - | - | - |
| Uric Acid | - | - | - |
| BUN | - | - | - |
| EGFR true 4/8 Weather kit perform Body Mass Index Test false TECHNICAL FEATURES Sample System Capacity & Volume required in the Analyzer 350 Micro Litter - Type of Charging Facility External Charging External Charging | - | - | - |
| Solar Power Cell | - | - | - |
| Solar Power & Battery (Both) Type of Data logging option 4 USB Slave | - | - | - |
| 1 USB host | - | - | - |
| 1 Ethernet Port for LIS - Technical Specification of the Centrifugation Unit provided NA - Data Recorder/Mini Laptop provided false Details of Patient Data Management Software LIS - Technical Specification of Bio-Chemistry Analyzer provided Analysis Methods End Point | - | - | - |
| Kinetics | - | - | - |
| Fix time (2 Point Kinetic) | - | - | - |
| 2 Point End | - | - | - |
| Turbidity | - | - | - |
| Absorbance Calibration Type 1- Point Linear (Factor) | - | - | - |
| 2- Point Linear | - | - | - |
| Multi-Standard (Linear & non-Linear) | - | - | - |
| Logit Log (3P/4P/5P) | - | - | - |
| Exponential | - | - | - |
| Spline & Parabola Wave Length 340 | - | - | - |
| 405 | - | - | - |
| 450 | - | - | - |
| 505 | - | - | - |
| 546 | - | - | - |
| 578 | - | - | - |
| 630nm; 2 extra spaces for optional filters Light source 6V/10W Halogen Lamp Photometric range 0.0000 - 3.0000 Abs Abs. Resolution 0.0001 Abs Stability < 0.005 Abs/hour Carry Over < 0.5% Flow Cell Volume 32 µL Cuvette Mode Yes | - | - | - |
| available. Flow Cell Temperature Control Peltier controlled: RT | - | - | - |
| 25⁰ C | - | - | - |
| 30⁰ C | - | - | - |
| and 37⁰ C Test Parameter Programmable 300 Programs Test Result Storage 2 | - | - | - |
| 000 - 5/8 Results Display & Input 7″ Color LCD with Touch screen operation. Virtual Keyboard incorporated for input External Mouse External USB Mouse attachable External Keyboard External USB Keyboard attachable Printer Built- in thermal Printer Supports External USB Printer PCL 3 GUI Language Communication Interface 4 USB slave; 1 USB Host and 1 Ethernet Port for LIS Q.C. Full QC Programme with L-J Curve Aspiration Peristaltic Pump with minimum Aspiration 200 μl to 1000 μl Power requirement Wide range power supply: AC 100 - 240V | - | - | - |
| 50/60HZ Ambient temperature 15°C~35°C | - | - | - |
| with fluctuation less than ±2°C/H Relative humidity 35%RH - 80%RH | - | - | - |
| without condensation. Dimension 400(L) X 300(W) X 160(H)mm Weight 6.0 kg technical Specification of Incubation Unit provided NA - Additional Safety Features Fuge - Patient Data Management software provided false External Dimensions of the Mobile Lab (the case): (Height X Width X Width) (mm X mm X mm) 400x300x160 - Operating and reading method of Analyzer True Rendom acess with Direct reading System - 6/8 CERTIFICATIONS & REPORTS Firm Certified to ISO9001:2008 or latest yes - Product is CE Certified false - Certification of Incubation Unit Yes - Certification of Bio Chemistry Analyzer Yes - Certification of Centrifugation Unit Yes - Certification for ISO 13485 Yes - Submission of all the Certificates to the buyer along with supplies on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sugarajan Thangavel 628004 | - | - | - |
| V.O.CHIDAMBARANA R PORT TRUST ADMIN OFFICE TUTICORIN 628004 2 15 EMD Advisory Bank HDFC Bank EMD Percentage(%) 2.00 EMD Amount 5960 ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 14 | - | - | - |
₹5,960
30 Jul 2018
16 May 2018
contract_GEMC-511687740884682.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_97581.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .