Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC | ₹3.4 Cr | L1 | Accepted-AOC Accepted being lowest tenderer |
| 2 | L2₹3.6 Cr+₹17.6 L (5.20%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹3.6 Cr+₹17.6 L (5.20%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹3.7 Cr+₹27.8 L (8.23%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹3.7 Cr+₹27.8 L (8.23%) | L3 | Rejected-Finance Other than L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical 2 class Below eligible category |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
22 Jan 2021, 6:00 pmClosed
HQ Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone Pathankot
PROVN OF ADDITIONAL AND ALTERATION OF WATER SUPPLY DISTRIBUTION NETWORK AT 2204 AT BIRPUR AT MIL STN RATNUCHAK
2020_MES_403833_1
CEPZ-08/2020-21
Open Tender
Civil Works
Lump-sum
365 days
GE (P) Jammu
All as per tender documents
7 documents required · 7 mandatory
₹2,000
GE Kaluchak
₹4.1 L
2 Mar 2021
15 Dec 2020
25 Jan 2021
16 Dec 2020
22 Jan 2021
5 Jan 2021
Amount
Lumpsum price worked out by the contractor for "Building work" as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for "Internal water supply work" as listed in Schedule 'A' Part-II (Sec-I).
Lumpsum price worked out by the contractor for "Internal electric Supply work" as listed in Schedule 'A' Part-III (Sec-I).
Lumpsum price worked out by the contractor for "Plumbing work" as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for "Sewage Disposal works" as listed in Schedule 'A' Part-V (Sec-I).
Lumpsum price worked out by the contractor for "Repairs to SWT 25000 gallons capacity works" as listed in Schedule 'A' Part-VI (Sec-I).
Lumpsum price worked out by the contractor for "Lightning protection works" as listed in Schedule 'A' Part-VII (Sec-I).
Lumpsum price worked out by the contractor for "Road, Path & Hardstanding" as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for "Area Drainage Works" as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for "Chain link fencing works" as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for "External Water supply work" as listed in Schedule 'A' Part-XI (Sec-I).
Lumpsum price worked out by the contractor for "External Electrification work" as listed in Schedule 'A' Part-XII (Sec-I).
Lumpsum price worked out by the contractor for "Earthwork for schedule ‘A’ Part ( II To XII)" as listed in Schedule 'A' Part-XIII.
Internal Water Supply works (Sch 'A' Part-II Sec-II)
Angle valve one way cast copper alloy, fancy type, chromium plated with cup (bore of pipe 15 mm) all as specified and directed. Make L- Prayag cat No 8310,or equivalent in NMV/SOMA
Internal Electrification works (Sch 'A' Part-III Sec-II)
Supply and fixing ceiling fans including accessories single phase 230 V, 1200 mm sweep BEE 5 Star rated complete including connecting with 3 core PVC insulated copper cable multistrandard suitable size from ceiling rose to fan connector all as specified and directed.
Supply and fixing exhaust fan 300/350 mm sweef including louvers connecting ith three core PVC insulated copper cable of suitable size multi-starded from ceiling rose to connector of exhaust fan.
S & F LED type tube light fitting 1 x 18 w with and including LED tube light 1X18 watt 230 volts,AC wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accesssories internally pre- wired and including connecting up with three core copper conductor cable of suitable size.Cat Part No-LCTL-18-CDL Make of -Crompton or make- Equivalent in philips, Bajaj and Havells.
M & L for earthing complete with G .l earth plate electrode 60 cm x 60 cm and 6 mm thick burried directly in ground ( earth pit not less than 2.25 m deep below GL ) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including provision of 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 40mmx40mmx3mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No. 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge .
S & F building security LED street light, 1X25 Watt,230 volt,energy saving and enviormental friendly long life versatile pressure dicast aluminium IP- 66 road way luminary with high power LED as light source and electronic driver.cat pt- No- LSTS-25-CDL Make of -Crompton or make- Equivalent in philips, Bajaj and Havells complete with suitable size GI pipe bracket for fixing of fitting on building wall surface.
Sewage Disposal works (Sch 'A' Part-V Sec-II)
Construction of on site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete for 10 users complete all as specified and directed.
Repairs to SWT 25000 gallons capacity works (Sch 'A' Part-VI Sec-II)
Treatment of all concrete defects to opening the joints/cracks such as cold joint, construction joints, cracks, corner joints and areas around honeycomb in the RCC of raft slab and column/footing/retaining wall by forming V/U shape groove with approx 15mm x 15mm size thereafter providing and applying a bond coat of Smart Care Multipurpose polymer in the groove thereafter sealing the groove with polymer modified mortar.
Injection grouting wherever required routing the joints through PVC injection nozzles fixed @1M c/c or less, using cement slurry grout with smartcare injection grout added @250 gm per bag of cement to full saturation etc complete all as specified and directed
Supplying and applying two component elastomeric acrylic polymer modified cementitious water proofing coating obtaining a consumption of 3KG/Sqm in 2-3 coats, smartcare damp block 2K or approved equivalent having 100% elongation as per ASTM D 412, resisting 5 bars hyrostatic pressure as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5, The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2parts of powder & 1 part of liquid without any water addition in the mixing etc, complete as per manufacturers specifications
Protection screed/render Application of screed/render admixed with smartcare multipurpose polymer @ 7% of the cement weight to achieve thickness of 15-20mm screed and 10-12 mm render as per approved methodology complete all as specified and directed
Lightning protection works (Sch 'A' Part-VII Sec-II)
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanised Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
External Water supply Works (Sch 'A' Part-XI Sec-II)
Relaying of old unserviceable galvanised iron pipe and connections as obtained including cleaning of pipe (externally & internally) by using wire brush, water etc and fixing the old pipe with new fittings and fixing the old pipe with new fittings to new / old position complete all as specified and directed for Galvanised iron pipe of 100mm bore
Relaying of old unserviceable galvanised iron pipe and connections as obtained including cleaning of pipe (externally & internally) by using wire brush, water etc and fixing the old pipe with new fittings and fixing the old pipe with new fittings to new / old position complete all as specified and directed for Galvanised iron pipe of 80mm bore
Air release valve confirming to IS-14845 with two air outlets 50mm dia and fixing with rising main 150mm dia Ductile iron pipe duly making hole by any means not more than 50mm dia , making clamps ( two flaps) fabricated out of 75 mm long MS plate 10mm thick and 150mm wide bent to shape making two nos suitable holes on both sides of each flap making 50mm hole in one hole and welding 50mm dia GI socket , fixing on rising mains with 3mm thick rubber inserting sheets and suitable nuts,bolts and washers (4 nos) and 50mm dia GI pipe medium grade one metre long duly threaded at both ends and fixed on 50mm socket at one end and other ends fixed with air release valve for fixing up in water supply rising main after making holes by any means including insertion of GI pipeline of 50mm dia at one end and fixing of air release valve at other end
Construction of 230mm thick brick masonary valve chamber built in CM 1:6 for valve pit of size 105cm x 105cm x 105cm ( internal dimentions) with 100mm thick foundation using PCC 1:4:8 type D2 with 100mm offset 15mm thick plastering internally and 15mm thick plastering externally in CM 1:6 up to 15 cm below GL, 3mm thick MS sheet cover , double door welded to 50mmx50mmx6mm MS angle iron frame fixed with hold fasts in PCC 1:23:4 type B1, coping 50mm thick with PCC 1:2:4 type B1,20mmx6mm flat iron hinges with locking arrangements including lock 65mm brass and keys,MShandles and applying one coat of red oxide primer and two coats of synthetic enamel paint too all steel surfaces including excavation and earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and as directed.
Flanges suitable for 150 mm bore pipe of thickness not less than 12mm duly drilled holes of suitable size matching with flanges of sluice vlave. Note :- (i) Flange joints will be measured separately under relevant item. (ii) Welding of flanges will be measured separately under relevant item
Flanges suitable for 100 mm bore pipe of thickness not less than 10mm duly drilled holes of suitable size matching with flanges of sluice vlave. Note :- (i) Flange joints will be measured separately under relevant item. (ii) Welding of flanges will be measured separately under relevant item
Flanges suitable for 80 mm bore pipe of thickness not less than 10mm duly drilled holes of suitable size matching with flanges of sluice vlave. Note :- (i) Flange joints will be measured separately under relevant item. (ii) Welding of flanges will be measured separately under relevant item.
Water Mains route indicator precast with PCC 1:2:4 of size 300x230x97.5 mm duly errected in ground upto 90 cm and duly painted with approved colour on top painted surface as "MES WATER MAINS - 100/150/200/ mm including necessary earth work all as specified and directed.
Welding to MS flanges to pipe line of dia upto 150 mm bore complete all as per site requirement and as specified and directed. Note :- (i) MS flanges shall be measured separately under relevant item. (ii) All T&P required for job is deemed to be included in this item rate.
Cutting existing cast iron of size 100/150 mm by means (2 cut) in position for insertion of DI fittings viz Tee, Collar, Bend or Tail piece etc upto 150 mm bore pipe complete all as specified and directed. Note :-(i) DI fittings shall be measured under relevent item. (ii) Excavation and earth work is deemed to be included in the unit rate.
Foot valve conforming to IS 4038 complete of size 150 mm dia complete all as specfied and directed at site.
Cutting of existing road not less than 0.35 meter in depth and not less than 0.6 metre wide for laying of DI pipe line of dia 150 mm all as specified and directed. Note:- (i) Removal of spoil in road cutting for laying of pipe line shall be measured under relevant item. (ii) Making good of disturbed/damaged road shall be measured under relevent item. (iii) Excavation and earth work beyond 0.35 metre depth will be measured under relevent item.
Dismantling , shifting and reassembling, fitting, testing and commissioning of Pumping sets, centrifugal ,electric driven, of rating 60HP from Base pump house to intermediate pumphouse at Birpur complete Including the following:- (i) Electric connection using suitable size brass lugs and glands with 95sqmm 3.5 core size of aluminium cable from Main LT panel to incoming MCCB of starter panel.(ii)Electric connection using suitable size brass lugs and glands with 50 sqmm 3 core size of copper cable from starter panel to motor terminals. (iii) Making the water pipe line connection to the water supply net work with 150 mm dia MS pipe and required materials including any item like cutting, welding etc required at site for making connections is deemed to be included in this item as directed at site. (iv) PCC foundations to install new pump set shall be as per manufacturer design including grouting suitable size of nuts, bolts and anti vibration pads for vibration free running of pump set shall be as per manufacturer design and the rates are deemed to be included in this item as directed at site. Note:- (i) Cable shall be measured separately under relevant items (ii) MS pipe shall be measured and paid separately under relevant item.
Supply, Installation, Commissioning and Testing of Horizontal centrifugal multistage pumping set electric driven 1450 RPM with bronze impeller and steel shaft having discharge 93M3/ HR at 125 Mtr head coupled with squirrel cage induction motor of capacity not less than 75 HP, 5 stage at 415 volts AC, 3 phase 50 Hz mounted on common base plate. Pump Model :- RKB125/27 or equivalent in Kirloskar, M&P, Grandfos & Beacon. Including the following:- (i) Electric connection using suitable size brass lugs and glands with 120 sqmm 3.5 core size of aluminium cable from Main LT panel to incoming MCCB of starter panel.(ii)Electric connection using suitable size brass lugs and glands with 70 sqmm 3 core size of copper cable from starter panel to motor terminals. (iii) Making the water pipe line connection to the existing water supply net work with 150 mm dia MS pipe and required materials including any item like cutting, welding etc required at site for making connections is deemed to be included in this item as directed at site. (iv) PCC foundations to install new pump set shall be as per manufacturer design including grouting suitable size of nuts, bolts and anti vibration pads for vibration free running of pump set shall be as per manufacturer design and the rates are deemed to be included in this item as directed at site. Location :- At Base Pump House Note:- (i) Cable shall be measured separately under relevant items (ii) MS pipe shall be measured and paid separately under relevant item.
Supply, Installation, Commissioning and Testing of Horizontal centrifugal multistage pumping set electric driven 1450 RPM with bronze impeller and steel shaft having discharge 45M3/ HR at 20 Mtr head coupled with squirrel cage induction motor of capacity not less than 10 HP, 2 stage at 415 volts AC, 3 phase 50 Hz mounted on common base plate. Pump Model :- Kirloskar Model No RKB65/19L or equivalent in KSB, M&P, Grandfos & Beacon. Including the following:- (i) Electric connection using suitable size brass lugs and glands with 16sqmm 4 core size of aluminium cable from Main LT panel to incoming MCCB of starter panel.(ii)Electric connection using suitable size brass lugs and glands with 16 sqmm 3 core size of copper cable from starter panel to motor terminals. (iii) Making the water pipe line connection to the existing water supply net work with 100 mm dia MS pipe and required materials including any item like cutting, welding etc required at site for making connections is deemed to be included in this item as directed at site. (iv) PCC foundations to install new pump set shall be as per manufacturer design including grouting suitable size of nuts, bolts and anti vibration pads for vibration free running of pump set shall be as per manufacturer design and the rates are deemed to be included in this item as directed at site. Location :- At Base Pump House Note:- (i) Cable shall be measured separately under relevant items (ii) MS pipe shall be measured and paid separately under relevant item.
External Electric supply Works (Sch 'A' Part-XII Sec-II)
Supply, installation, commissioning and testing of Diesel Engine driven water cooled generating set of capacity 200 KVA, 415 Volts, BHP as per manufacture recommendation, AC Supply, 50 Hz, 3 phase 4 wire, 0.8 PF at NTP, speed 1500 RPM at Ratnuchak mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 01 metre complete including PCC foundation in all respect as per norms of OEM. DIESEL ENGINE : Water cooled diesel engine of adequate capacity suitable to deliver 200 KVA power at 1500 RPM generally in accordance with latest BIS/IS Specification provided with blower fan, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/alternator , air cleaner, diesel/oil filters, complete in all respect. The engineer shall be capable of takings 10% over load for one hour for every 12 hours running conforming to the environment (PROTECTION ACT 1986) (29 OF 1986) and as amended vide Gazette of India Notification Part II sections III Sub Section (I) dated 12 Jul 2004.
ENGINE INSTRUMENT PANEL : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, oil pressure, battery charging, ammeter, hours meter, starting switch etc FUEL TANK : In built fuel tank adequate capacity for 12 hours running with stop cock, drain plug as per recommendation of OEM ALTERNATOR : 200 KVA at NTP at Ratnuchak Mil Stn, 3 phase 50 Hz, 415 volts, AC supply, 0.8 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule. CONTROL PANEL : The standard control panel shall be built in accoustic enclosures with the following accessories complete wired with suitable size of copper cable with following accessories:- (i) MCCB of suitable rating with over load and short circuit protection. (ii) Digital Ammeter (iii) Digital Voltmeter (iv) One set of indicating LED lamps RYB and fuses. (v) Frequency meter, RPM meter, Hour meter, Fuel level indicator. (vi) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load. (vii) Water temperature gauge, oil pressure gauge
Note : The Gen set must be affixed with label meeting the following requirement ( The label shall be durable and legible) (a) Name and address of the engine manufacturer. (b) Statement that this engine conforms to the environment (PROTECTION) (c) Type and approval certificate number. (d) Date of manufacturing of Gen set. ACOUSTIC ENCLOSURE : Acoustic enclosure should be as per manufacturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 meter sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions : (i) Fitting arrangement (ii) Point for neutral and bod earthing (iii) Fuel drain (iv) Lub oil drainage (v) Air breather (vi) Easy stop push button (vii) Panel meter viewing window (viii) Canopy light as per OEM recommendations Note : (i) DG set should be sound proof as per latest policy (ii) First filling of Engine oil and Fuel etc should be arranged by contractor for testing.
Supply, installation, commissioning and testing of Diesel Engine driven water cooled generating set of capacity 100 KVA, 415 Volts, BHP as per manufacture recommendation, AC Supply, 50 Hz, 3 phase 4 wire, 0.8 PF at NTP, speed 1500 RPM at Ratnuchak mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 01 metre complete including PCC foundation in all respect as per norms of OEM. DIESEL ENGINE : Water cooled diesel engine of adequate capacity suitable to deliver 100KVA at 1500 RPM generally in accordance with latest BIS/IS Specification provided with blower fan, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/alternator , air cleaner, diesel/oil filters, complete in all respect. The engineer shall be capable of takings 10% over load for one hour for every 12 hours running conforming to the environment (PROTECTION ACT 1986) (29 OF 1986) and as amended vide Gazette of India Notification Part II sections III Sub Section (I) dated 12 Jul 2004.
ENGINE INSTRUMENT PANEL : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, oil pressure, battery charging, ammeter, hours meter, starting switch etc FUEL TANK : In built fuel tank adequate capacity for 12 hours running with stop cock, drain plug as per recommendation of OEM ALTERNATOR : 100 KVA at NTP at Ratnuchak Mil Stn, 3 phase 50 Hz, 415 volts, AC supply, 0.8 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule. CONTROL PANEL : The standard control panel shall be built in accoustic enclosures with the following accessories complete wired with suitable size of copper cable with following accessories:- (i) MCCB of suitable rating with over load and short circuit protection. (ii) Digital Ammeter (iii) Digital Voltmeter (iv) One set of indicating LED lamps RYB and fuses.
(v) Frequency meter, RPM meter, Hour meter, Fuel level indicator. (vi) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load. (vii) Water temperature gauge, oil pressure gauge Note : The Gen set must be affixed with label meeting the following requirement ( The label shall be durable and legible) (a) Name and address of the engine manufacturer. (b) Statement that this engine conforms to the environment (PROTECTION) (c) Type and approval certificate number. (d) Date of manufacturing of Gen set. ACOUSTIC ENCLOSURE : Acoustic enclosure should be as per manufacturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 meter sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions : (i) Fitting arrangement (ii) Point for neutral and bod earthing (iii) Fuel drain (iv) Lub oil drainage (v) Air breather (vi) Easy stop push button (vii) Panel meter viewing window (viii) Canopy light as per OEM recommendations Note : (i) DG set should be sound proof as per latest policy (ii) First filling of Engine oil and Fuel etc should be arranged by contractor for testing.
Supply and fix Integral LED security light luminaire 90W LED(Efficacy :120LM/W) 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 with 10 KV inbuilt surge protector including complete all as specified and as directed. Make: Crompton Greaves Cat part No LSTP-90-CDL-M/C&S Cat No-LTESS90WLED/LS/ Bajaj Cat Part No BRTFG90WLEDCR
Supply and fix pole bracket bent to shape made out of GI pipe 40 mm dia medium grade of length not less than 1.2 mtr fixed with and including two sets of MS clamps made out of flat iron of size 50x6mm fabricated to shape and fix with nuts ,bolts and washers and two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed..
M & L for junction box hot press moulded SMC of inside dimension size 300 x 200 x 100 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar 4 strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amp MCB SPN, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed. Make- RMC SWITCHGEARS LTD
Design, Supply, install, testing and commissioning of HT 11KV outdoor type Kiosk Box ( size:1000mm x 1500mm x 1500mm) suitable for input and output cable size 185sqmm 3 core XLPE Al cable, dust and vermin proof degree of protection IP 66,factory made CPRI approved with locking arrangement made out of CRCA sheet 3.15mm thick with suitable size of channel for base complete with 800 Amps rated copper bus bar(current density 1.6A/sqmm) fixed on HT porcelain insulator with cable gland and lugs of size 185sqmm x 3 core and fixing the HT cable properly on HT bus bar and duly powder coated in Siemens grey shade as per IS : 5,mounted on PCC platform(45cm below and 60cm above ground level) of PCC 1:2:4 type B1 using 20mm graded aggregate on angle iron frame which is made out of 50 x 50 x 6mm thick angle iron(4 legs each length 75cm, duly embedded in PCC/ground ) duly marked the incoming outgoing controls complete all as specified and directed. Make of HT Panel Builder: M/s Core Metal Krafts Limited, Chandigarh. Note: The Contractor Should produce diagram from CPRI certified Panel manufacturer for approval from Accepting officer prior to procurement action.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cable including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following:- (for 200 KVA TR) (a) Aluminium bus bar with proper colour code-04 Nos 600 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations. (b) Indicator Lamp-01 Set (Set of three) with control wiring. (c) Incoming MCCB, 4 Pole, 400 amp, 415 V, 36 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (d) Outgoing MCCB, 4 Pole, 200 amp, 415 V, 25 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No
(e) Outgoing MCCB, 4 Pole, 100 amp, 415 V, 16 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (f) Outgoing MCCB, 4 Pole, 63 amp, 415 V, 16 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (g) Multifunction Digital meter(VAF,W/VA/VAr/PF) - 01 No Make:- Schneider CAT No: ELF3234-3 CI0.5 (h) On-Load 400A, 415V, AC 50HZ Panel mounted Change over switch - 01 No (j)CT 400/5A, Set of three Make:- Legrand (k) Complete wiring with copper cable, thimble etc.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cable including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following:- (for 100 KVA TR) (a) Aluminium bus bar with proper colour code-04 Nos 300 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations. (b) Indicator Lamp-01 Set (Set of three) with control wiring. (c) Incoming MCCB, 4 Pole, 200 amp, 415 V, 36 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (d) Outgoing MCCB, 4 Pole, 160 amp, 415 V, 25 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-03 No
(e) Outgoing MCCB, 4 Pole, 63 amp, 415 V, 16 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (f) Outgoing MCCB, 4 Pole, 63 amp, 415 V, 16 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (g) Multifunction Digital meter(VAF,W/VA/VAr/PF) - 01 No Make:- Schneider CAT No: ELF3234-3 CI0.5 (h) On-Load 200 A, 415V,AC 50Hz, Panel mounted Change over switch - 01 No (j)CT 200/5A, Set of three Make:- Legrand (k) Complete wiring with copper cable, thimble etc.
Supply, installation, testing and commissioning of Pump Starter panel of suitable size (10 HP) for 3 Phase 415 volt, indoor type made out 2.00mm thick CRCA sheet with angle iron frame of size 50x50 x6 mm cubical type complete with MCCBs, copper bus bar 100 Amp , with IP 54 as per IS 13947 protection, fault rating 50 KA/1Sec, complete with following-location-Base Pump House Birpur including the following items (a) Incoming MCCB, 4 Pole, 32 amp, 415 V, 16 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (b) Star delta Starter fully automatic suitable for 415 V AC for 10 HP motor---01 No (c) Multifunction Digital meter(VAF,W/VA/VAr/PF) - 01 No Make:- Schneider CAT No: ELF3234-3 CI0.5 (d)CT 100/5A, Set of three Make:- Legrand (e) Smart motor controller protection having feature as protection against under voltage, over voltage, phase loss, phase unbalance, phase asymmetry and auto phase polarity correction with time delay and having display of voltage, current, power factor, frequency(SMPC100DV00)--01 No
Supply, installation, testing and commissioning of Pump Starter panel of suitable size (75 HP) for 3 Phase 415 volt, indoor type made out 2.00mm thick CRCA sheet with angle iron frame of size 50x50 x6 mm cubical type complete with MCCBs, copper bus bar 300 Amp , with IP 54 as per IS 13947 protection, fault rating 50 KA/1Sec, complete with following-location-Base Pump House Birpur including the following items :- (a) Incoming MCCB, 4 Pole, 200 amp, 415 V, 36 KA rupturing capacity, with adjustable settings 80% to 100%, Thermal Magnetic Release (Ics=100% Icu)-01 No (b) Star delta Starter fully automatic suitable for 415 V AC for 75 HP motor--- 01 No (c) MD—XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase, 440 V, 50 Hz system for permissible non- leaner load 20% of capacity 15 KVAR (d) Multifunction Digital meter(VAF,W/VA/VAr/PF) - 01 No Make:- Schneider CAT No: ELF3234-3 CI0.5 (e)CT 200/5A, Set of three Make:- Legrand (f) Smart motor controller protection having feature as protection against under voltage, over voltage, phase loss, phase unbalance, phase asymmetry and auto phase polarity correction with time delay and having display of voltage, current, power factor, frequency(SMPC100DV00)--01 No
Platform for installation of transformer of size 3x2.5x1 metre for installation of transformer with brick steps on one side, chain link fencing around transformer , fencing should have hinged door and locking arrangements complete all as shown on drawing No CEPZ/C-TD/002/13 Sheet 2/5 complete all as directed
GUPTA CONSTRUCTION
SATISH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .