Tender Value
₹30.8 L
EMD Value
₹61,540
Closing Date
11 Sept 2023, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINT CENTRIFUGAL MONOBLOCK PUMP SETS STARTER AND ALLIED WORKS IN THE AREA OF AGE U WS III UNDER GE U WATER SUPPLY DELHI CANTT 10
2023_MES_612580_1
GE/WS/IFA-05/Token-12 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹61,540
Yes
30 Oct 2023
7 Aug 2023
13 Sept 2023
7 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Opening the electric induction motor of cap 10-25 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and directed. (Note : "Copper winding wire of appropriate gauge will be measured and paid under item No. 17 as supply only").
Opening the electric induction motor of cap 30-40HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and directed. (Note : "Copper winding wire of appropriate gauge will be measured and paid under item No. 17 as supply only").
Opening the electric induction motor of cap 50-75 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed (Note : "Copper winding wire of appropriate gauge will be measured and paid under item No. 17 as supply only").
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 10-25 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and directed
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 30-40 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and directed.
Disconnecting of electrical connections from panel board and taking out electic motor of capacity 50-75 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and directed.
Supply and fixing in replacement of terminal box suitable for 30-40 HP Motor complete all as specified and directed..
Supply and fixing in replacement of terminal box suitable for 50-75 HP Motor complete all as specified and directed..
Supply and Fixing of terminal connection plate suitable for 10-25 HP motor complete all as specified and directed.
Supply and Fixing of terminal connection plate suitable for 30-40 HP motor complete all as specified and directed.
Supply and Fixing of terminal connection plate suitable for 50-75 HP motor complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate suitable for electric motor 10-25 HP complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate suitable for electric motor 30-40 HP complete all as specified and directed.
Supply and Fixing in replacement of CI bearing plate suitable for electric motor 50-75 HP complete all as specified and directed.
Disconnecting of electrical connection from panel board and taking out monoblock pump of Cap upto 10 HP from foundation transporting the monoblock to workshop and back after repair, reinstall and testing complete all as specified and directed.
Openig the monoblock pump set of cap upto 10 HP and taking out the burnt winding wire complete and cleaning the slots rewinding the motor with super enamelled copper wire of existing gauge/size with and including insulating material. Compete all as specified and as directed. (Note : "Copper winding wire of appropriate gauge will be measured under item No. 17 as supply only").
Supply only super enamelled copper winding wire of suitable gauge including insulation complete all as specified and directed. (Note:- BOO for measuring of new copper winding wire incorporated in each motor shall be prepared alongwith inventory of old scrap copper winding wire obtained after opening of motor and signed by EIC/JE (E/M).
Disconnecting and de-coupling the centrifugal pump of cap 10-25 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and directed.
Disconnecting and De-coupling the centrifugal pump of cap 30-40 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and directed.
Disconnecting and De-coupling the centrifugal pump of cap 50-75 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and directed by engr-in-charge
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 10 to 25 HP complete all as specified and directed (Note :- Spare Part will be measured & paid spaerately).
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 30 to 40 HP complete all as specified and directed (Note :- Spare Part will be measured & paid spaerately)
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 50 to 75 HP complete all as specified and directed Note :- Spare Part will be measured & paid spaerately
Supply only following spare parts for centrifugal Pump of capacity 10-25 HP:-
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/P/011 make unique
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 30-40 HP
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014 make unique
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 50-75HP
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/P/017 make unique
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
MS coupling key
M&L painting of steel surfaces by applying two coat of synthetic Enamel paint on centrifugal pump & motor of any capacity rating 10-75 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed.
S&F in replacement of MS base channel of existing size including cutting welding making hole complete all as specified and directed.
S&F in replacement of MS foundation bolts with nuts and washers size 20 mm dia and 450 mm long complete all as specified and directed
Supply only Ball bearing 6305
Supply only Ball bearing 6306
Supply only Ball bearing 6307
Supply only Ball bearing 6308
Supply only Ball bearing 6309
Supply only Ball bearing 6310
Supply only Ball bearing 6311
Supply only Ball bearing 6312
Supply only Ball bearing 6313
Supply only Ball bearing 6314
Supply only of double ball bearing 3307
Supply only of double ball bearing 3309
Supply only of double ball bearing 21309
Supply only of Rollar bearing No-313
Supply only of Rollar bearing No-314
Supply and fixing in replacement of CI Foot Valve Flanged 100 mm bore complete all as specified and as directed
Supply and fixing in replacement of CI Foot Valve Flanged 150 mm bore complete all as specified and as directed
Supply and fixing of CI Non return valve of follolwing sizes complete all as specified and as directed
80 mm dia.
100 mm dia
150 mm dia
200 mm dia
Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed
100 mm dia.
150 mm dia.
200 mm dia.
Supply and fixing in replacement of star delta starter type ML-1.5 complete all as specified and directed
Supply and fixing in replacement of star delta starter type ML-2 complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-3 complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-12 complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-6 complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-4 complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-1.5 complete all as specified and directed
M&L in replacement of phase failure relay with under and over voltage relay setting (variable) Auto reset 4%-20% unbalance with neutral tail protection type DZV MR-2 complete all as specified and directed
M&L in replacement of panel mounting single phase preventor type VSP-II complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 10.00 Sq mm complete all as specified and directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 16.00 Sq mm complete all as specified and directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 25.00 Sq mm complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 50.00 Sq mm complete all as specified and directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 95.00 Sq mm complete all as specified and directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 9-14 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 13-21 amp complete all as specified and directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 20-32 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 28-42 amp complete all as specified and directed
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and directed
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and as directed
S&F in replacement of Indicating light complete all as specified and directed
S&F in replacement moulded case circuit breakers 3 pole 400 Amps having breaking capcity 50 KA at 415 volts complete all as specified and directed
S&F in replacement moulded case circuit breakers 3 pole 200 Amps having breaking capcity 35 KA at 415 volts complete all as specified and directed
S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity 25 KA at 415 volts complete all as specified and directed
S&F in replacement Timer (ST-100) switch complete all as specified and directed
Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible Sewage pump set of any size 5 HP to 25 HP capacity and removing the pipe line connections from discharge side and taking out submersible pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including replacement of rusted nuts bolts, rubber gasket complete all as specified and directed
Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 5HP to 10 HP capacity complete all as specified and as directed. (Note :- Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only).
Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 12.5 HP to 25 HP capacity complete all as specified and as directed. (Note :- Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)
Supply and in replacement following spare parts for non-clogging sewage submersible pump set vertical type (KRTU type) of capacity upto 25 HP:-
SS rotor sleeve
SS rotor shaft ASS 410
Water Seal
Connection Plate
Remetaling of rotor & turning/grinding
GM suction ring
GM/SS Impeller
SS stud with nut
Impeller Nut
Impeller Key
Joint of submersible cable
Submersible cable flat/round 3 Core 10Sqmm
Repairing of stamping of stator
Jointing of cable kit without float switch
CI suction plate
O Ring set
Insulation kit
Temperature sensor
Moisture sensor
Ball bearing 6312ZZ
Roller Bearing 3310
Roller Bearing NU 305
Bearing 6306 2RS1/C3
Bearing 6308 2RS1/C3
Bearing 6309 2 R S1/C3
Bearing 3212
Supply and fixing in replacement CI Casing body of pump cap 40/50 HP kirloskar make as site with and including Installation testing allignment and nut bolt washer etc complete all as specified and directed.
M&L of earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead 32mm x 6mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all surrounded by adequete quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, earth strip encased in 40 mm bore GI medium grade pipe, including providing watering pipe 20 mm bore GI pipe medium grade from bottom of the earth pit to the top of the electrode complete with earth pit in PCC 1:2:4 type B - O using 12 mm graded crushed stone aggregate, earth work and RCC cover Complete all as specified and shown in electrical plate number 3 of SSR part -1, incl taking down of old earthing complete all as specified and directed.
S&F in replacement GI Earthing strip 32x6mm including nut bolts and connecting items complete all as specified and directed
NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost alongwith other penalities as mentioned in contract. The decision of accepting officer in this regard shall be final concluding and binding on the contractor.
M&L for replacing U/s gland packing champion of pump set of any capacity at site complete all as specified and directed.
Note:- Sch of credit amount of Rs. 226112/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
PRASAD ELECTRICALS
M/s Shri Shyam Bharat Builders
KUSHAL ENTERPRISES
B.R. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .