| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹35.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹36.1 LRejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | ₹36.1 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹40.2 LRejected-Finance | ₹40.2 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹40.5 LRejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹40.5 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹42.1 LRejected-Finance NO 3 PERIYAR STREET ANAIKATTUCHERI PATTABIRAM CHENNAI 600 072 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600072 | ₹42.1 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Banyan Engineers and Contractors L2 | PSK Enterprises L6 | Shri Varaghaa L5 | M/s Omm Muruga Enterprises L3 | muthu constructions L1 | SAMYDOSS CONSTRUCTIONS L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00PART - I - SPECIAL REPAIRS TO COOLING APPLIANCES AGAINST BER AT MTTI | |||||||||
| 2.00 | Disconnecting electrical supply from source and taking down split/window type Air Conditioner of any capacity along with voltage stabilizer and all accessories, without damaging other installations, making good disturbed surfaces to match with existing finish, and transporting the same to MES Store Yard GE Avadi, complete all as specified and as directed | 25 | Each Job | 500 ₹12,500 | 1,301 ₹32,525 | 130 ₹3,250 | 1,201 ₹30,025 | 1,500 ₹37,500 | 1,300 ₹32,500 |
| 3.00 | Supply, installation, testing and commissioning of Hi-wall split type Air Conditioner of 1.5 TR capacity complete with indoor and outdoor units, cordless remote control unit, inbuilt ionizer and plasma filter for improved indoor air quality, having minimum 5-star rating and EER not less than 3.2 with copper condenser coil; including fixing of GI powder coated brackets (16 SWG) for mounting of outdoor unit with suitable fasteners and grouting, laying of copper refrigerant tubing of suitable sizes (1/4" and 1/2") with PUF insulation along with all connected accessories, and PVC drain pipe of 20/15 mm dia for indoor unit, complete all as specified and as directed | 25 | Each | 57,000 ₹14,25,000 | 71,000 ₹17,75,000 | 71,000 ₹17,75,000 | 69,999 ₹17,49,975 | 60,000 ₹15,00,000 | 70,000 ₹17,50,000 |
| 4.00 | Supply and fixing of Automatic Voltage Stabilizer suitable for 1.5 TR split Air Conditioner, having input voltage range of 170–270 volts (or as specified), output voltage 230 volts ± 10%, capacity 5 kVA, with high/low voltage cut-off protection, time delay relay, thermal overload protection, complete with all connections, fixing arrangements and testing, complete all as specified and as directed | 25 | Each | 3,700 ₹92,500 | 7,002 ₹1,75,050 | 7,000 ₹1,75,000 | 6,969 ₹1,74,225 | 5,000 ₹1,25,000 | 7,000 ₹1,75,000 |
| 5.00PART - II - PROVN OF VITRIFIED TILES & ALUMINIUM PARTITION IN CQA (HV) | |||||||||
| 6.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing of unserviceable materials outside premises, complete all as specified and as directed. | 30 | Sqm | 90 ₹2,700 | 72 ₹2,160 | 72 ₹2,160 | 72 ₹2,160 | 50 ₹1,500 | 50 ₹1,500 |
| 7.00 | Demolition of cement concrete (unreinforced) in ground floor or pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed | 5 | Cum | 600 ₹3,000 | 821 ₹4,105 | 821 ₹4,105 | 750 ₹3,750 | 200 ₹1,000 | 800 ₹4,000 |
| 8.00 | Material and labour for 100 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub-base, complete all as specified and as directed. | 50 | Sqm | 400 ₹20,000 | 599 ₹29,950 | 599 ₹29,950 | 555 ₹27,750 | 500 ₹25,000 | 600 ₹30,000 |
| 9.00 | Material and labour for 25 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed | 200 | Sqm | 150 ₹30,000 | 369 ₹73,800 | 369 ₹73,800 | 333 ₹66,600 | 300 ₹60,000 | 250 ₹50,000 |
| 10.00 | Material and labour for 40 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed. | 70 | Sqm | 250 ₹17,500 | 382 ₹26,740 | 382 ₹26,740 | 399 ₹27,930 | 400 ₹28,000 | 700 ₹49,000 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
22 Apr 2026, 6:00 pmClosed
Garrison Engineer, Avadi
GE Avadi
SPECIAL REPAIRS TO COOLING APPLIANCES INCLUDING PROVN OF VITRIFIED TILES AND ALUMINIUM PARTITION IS ADM BLDG OF CQA (HV) AND CERTAIN OTHER MINOR WORKS UNDER GE AVADI
2026_MES_758869_1
8379/E8
Open Tender
Miscellaneous Works
180 days
GE Avadi
As per tender documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹75,000
Yes
30 Jun 2026
1 Apr 2026
24 Apr 2026
1 Apr 2026
22 Apr 2026
9 Apr 2026
1 Apr 2026 - 4 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | PART - I - SPECIAL REPAIRS TO COOLING APPLIANCES AGAINST BER AT MTTI | - | - | - | - |
| - | Disconnecting electrical supply from source and taking down split/window type Air Conditioner of any capacity along with voltage stabilizer and all accessories, without damaging other installations, making good disturbed surfaces to match with existing finish, and transporting the same to MES Store Yard GE Avadi, complete all as specified and as directed | - | Each Job | - | - |
| - | Supply, installation, testing and commissioning of Hi-wall split type Air Conditioner of 1.5 TR capacity complete with indoor and outdoor units, cordless remote control unit, inbuilt ionizer and plasma filter for improved indoor air quality, having minimum 5-star rating and EER not less than 3.2 with copper condenser coil; including fixing of GI powder coated brackets (16 SWG) for mounting of outdoor unit with suitable fasteners and grouting, laying of copper refrigerant tubing of suitable sizes (1/4" and 1/2") with PUF insulation along with all connected accessories, and PVC drain pipe of 20/15 mm dia for indoor unit, complete all as specified and as directed | - | Each | - | - |
| - | Supply and fixing of Automatic Voltage Stabilizer suitable for 1.5 TR split Air Conditioner, having input voltage range of 170–270 volts (or as specified), output voltage 230 volts ± 10%, capacity 5 kVA, with high/low voltage cut-off protection, time delay relay, thermal overload protection, complete with all connections, fixing arrangements and testing, complete all as specified and as directed | - | Each | - | - |
| - | PART - II - PROVN OF VITRIFIED TILES & ALUMINIUM PARTITION IN CQA (HV) | - | - | - | - |
| - | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing of unserviceable materials outside premises, complete all as specified and as directed. | - | Sqm | - | - |
| - | Demolition of cement concrete (unreinforced) in ground floor or pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed | - | Cum | - | - |
| - | Material and labour for 100 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub-base, complete all as specified and as directed. | - | Sqm | - | - |
| - | Material and labour for 25 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed | - | Sqm | - | - |
| - | Material and labour for 40 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed. | - | Sqm | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8379tenderdocuments.pdf
Tender Documents • 1.19 MB
BOQ_850000.xls
BOQ • 11.56 MB
Download all tender documents and submit your bid