Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-Finance | ₹12.1 L | L1 | Accepted-Finance First Lowest |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
17 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONSTRUCTION OF ADDITIONAL TWO ROOMS FOR INMATE OF NARI NIKETAN TRUST, NAKODAR ROAD JALANDHAR (MPLAD SCHEME)
2026_CEPW_163198_1
Re-Bid No 56 of 10/03/2026
Open Tender
Civil Works - Buildings
90 days
JALANDHAR
Please refer Tender documents.
13 documents required · 13 mandatory
₹5,000
₹27,000
Yes
20 Mar 2026
10 Mar 2026
18 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONSTRUCTION OF ADDITIONAL TWO ROOMS FOR INMATE OF NARI NIKETAN TRUST, NAKODAR ROAD JALANDHAR. (MPLAD SCHEME)
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 A1) BUILDING WORK GROUND FLOOR 2
2 Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. 3 Cum Excess(+) Full Conversion INR
3 Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type 4 Cum Excess(+) Full Conversion INR
4 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 5 Cum Excess(+) Full Conversion INR
5 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 6 Qtl Excess(+) Full Conversion INR
6 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels 7 Sqm Excess(+) Full Conversion INR
7 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 8 Sqm Excess(+) Full Conversion INR
8 First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth 9 Cum Excess(+) Full Conversion INR
9 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres aboveplinth level. 10 Cum Excess(+) Full Conversion INR
10 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure 11 Sqm Excess(+) Full Conversion INR
11 12.5 mm thick cement plaster 1:5 12 Sqm Excess(+) Full Conversion INR
12 20mm thick cement plaster 1:5 in two coat work 13 Sqm Excess(+) Full Conversion INR
13 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 14 Sqm Excess(+) Full Conversion INR
14 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. 15 Metre Excess(+) Full Conversion INR
15 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 16 Each Excess(+) Full Conversion INR
16 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. 17 Metre Excess(+) Full Conversion INR
17 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a UPVC 110 mm bend 18 Each Excess(+) Full Conversion INR
18 Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a UPVC 110 mm Coupling/ Sockets 19 Each Excess(+) Full Conversion INR
19 Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 20 Each Excess(+) Full Conversion INR
20 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres 21 Cum Excess(+) Full Conversion INR
21 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 22 Cum Excess(+) Full Conversion INR
22 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material 23 Sqm Excess(+) Full Conversion INR
23 Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. a Size 600x600 mm 24 Sqm Excess(+) Full Conversion INR
24 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 25 Sqm Excess(+) Full Conversion INR
25 Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 26 Sqm Excess(+) Full Conversion INR
26 Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 27 Sqm Excess(+) Full Conversion INR
27 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (a) For fixed portion and chawkhats 28 Kgs Excess(+) Full Conversion INR
28 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required 29 Kgs Excess(+) Full Conversion INR
29 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. 30 Sqm Excess(+) Full Conversion INR
30 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) i) Float glass panes of 5 mm thickness 31 Sqm Excess(+) Full Conversion INR
31 Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. 32 Sqm Excess(+) Full Conversion INR
32 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300mm x 16mm 33 Each Excess(+) Full Conversion INR
33 Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. 34 Kgs Excess(+) Full Conversion INR
34 Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. 35 Sqm Excess(+) Full Conversion INR
35 A2) BUILDING WORK FIRST FLOOR 36
36 First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 37 Cum Excess(+) Full Conversion INR
37 Extra for work done in additional storey upto 4 metre above the top of structural roof of lowerstorey for Brick Work/ Concrete Block/ Clay Block. 38 Cum Excess(+) Full Conversion INR
38 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure 39 Cum Excess(+) Full Conversion INR
39 Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 40 Sqm Excess(+) Full Conversion INR
40 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 41 Cum Excess(+) Full Conversion INR
41 Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 42 Cum Excess(+) Full Conversion INR
42 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 43 Qtl Excess(+) Full Conversion INR
43 Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19 44 Qtl Excess(+) Full Conversion INR
44 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels 45 Sqm Excess(+) Full Conversion INR
45 Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 46 Sqm Excess(+) Full Conversion INR
46 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 47 Sqm Excess(+) Full Conversion INR
47 Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 48 Sqm Excess(+) Full Conversion INR
48 12.5 mm thick cement plaster 1:5 49 Sqm Excess(+) Full Conversion INR
49 Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. 50 Sqm Excess(+) Full Conversion INR
50 20mm thick cement plaster 1:5 in two coat work 51 Sqm Excess(+) Full Conversion INR
51 Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. 52 Sqm Excess(+) Full Conversion INR
52 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 53 Sqm Excess(+) Full Conversion INR
53 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. 54 Metre Excess(+) Full Conversion INR
54 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 55 Each Excess(+) Full Conversion INR
55 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. 56 Metre Excess(+) Full Conversion INR
56 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a UPVC 110 mm bend 57 Each Excess(+) Full Conversion INR
57 Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a UPVC 110 mm bend 58 Each Excess(+) Full Conversion INR
58 Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 59 Each Excess(+) Full Conversion INR
59 Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material 60 Sqm Excess(+) Full Conversion INR
60 Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. a Size 600x600 mm 61 Sqm Excess(+) Full Conversion INR
61 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. a Size 600x600 mm. 62 Sqm Excess(+) Full Conversion INR
62 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 63 Sqm Excess(+) Full Conversion INR
63 Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 64 Sqm Excess(+) Full Conversion INR
64 Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 65 Sqm Excess(+) Full Conversion INR
65 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (a) For fixed portion and chawkhats 66 Kgs Excess(+) Full Conversion INR
66 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required 67 Kgs Excess(+) Full Conversion INR
67 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. 68 Sqm Excess(+) Full Conversion INR
68 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) i) Float glass panes of 5 mm thickness 69 Sqm Excess(+) Full Conversion INR
69 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : A) 300mm x 16mm 70 Each Excess(+) Full Conversion INR
70 Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron covermoulding of 12.5 mm width, fixed with machine screws, complete in all respects. 71 Sqm Excess(+) Full Conversion INR
71 Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. 72 Kgs Excess(+) Full Conversion INR
72 Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. 73 Sqm Excess(+) Full Conversion INR
73 Stripping and stacking slate or tiles of a roof. 74 Sqm Excess(+) Full Conversion INR
74 A3) ELECTRICAL WORK:- 75
75 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 Buniversal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 76
76 I) Wiring fan point (With fan box) 77 Each Excess(+) Full Conversion INR
77 II) Wiring light point 78 Each Excess(+) Full Conversion INR
78 (iv) Wiring 6Amp. wall socket point 79 Each Excess(+) Full Conversion INR
79 (v) Wiring 6Amp. Plug control comprising wall socket point 80 Each Excess(+) Full Conversion INR
80 (vi) Wiring 16/20Amp. power plug control point 81 Each Excess(+) Full Conversion INR
81 PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 82
82 (ii) Overall size 1.5sq.mm (Un-sheathed) 83 Per Metre Excess(+) Full Conversion INR
83 (iii) Overall size 2.5sq.mm (Un-sheathed) 84 Per Metre Excess(+) Full Conversion INR
84 (iv) Overall size 4sq.mm (Un-sheathed) 85 Per Metre Excess(+) Full Conversion INR
85 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- (x) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 86 Per Metre Excess(+) Full Conversion INR
86 Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- (a) SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement 87 Each Excess(+) Full Conversion INR
87 Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in charge at site. 88 Each Excess(+) Full Conversion INR
88 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory 89 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
BOQ_330622.xls
BOQ • 0.36 MB
Technical_Conditions.pdf
Tender Documents • 0.46 MB
SBD.pdf
Tender Documents • 4.37 MB
Download all tender documents and submit your bid