Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC RATES WERE REASONABLE | |
| 2 | L2₹17.2 L+₹39,002.90 (2.31%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹17.4 L+₹57,871.69 (3.43%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.6 L+₹73,113.60 (4.34%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹17.6 L+₹79,128.96 (4.69%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
23 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGRS
SPL REPAIR OF 11 KV KANCHANJUNGA OFFICERS ENCLAVE POWER HOUSE AT KALIMPONG MIL STN UNDER GE 867 EWS 2nd CALL
2020_MES_401262_2
CWE/136-WE/68 OF 2020-21
Open Tender
Civil Works
Item Rate
182 days
KALIMPONG
Class e, Category b (I)
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹31,000
23 Jul 2021
9 Jan 2021
25 Jan 2021
9 Jan 2021
23 Jan 2021
16 Jan 2021
9 Jan 2021 - 14 Jan 2021
60 days
Amount
Dismantling of plain or corrugated steel sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws all as specified and directed by Engr-in-Charge.
M & L hardcore (Broken stone or boulders)of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed
M & L 75mm thick Cement concrete type D- 2, 1:4:8 (40mm graded crushed aggregate)as in sub base all as specified and directed
M & L 75mm thick Cement concrete type C- 1, 1:3:6 (20mm graded crushed aggregate) finishing cement concrete surface even and smooth as in plinth protection ,path,step etc. all as specified and directed
M & L 100mm thick Cement concrete type B- 1, 1:2:4 (20mm graded crushed aggregate) finishing cement concrete surface even and smooth as in floor finished all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in Cement concrete in foundations, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type A1 1:1½:3 (20mm graded crushed stone aggregate) as in beam,lintel/plinth band including form work complete all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces complete all as specified and directed.
Use & Waste of formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide rough finished flat surfaces complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
Supply only integral water proofing compond all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash as in wall complete all as specified and directed.
M&L for preparation on newly plastered / previously untreated surfaces of wall and applying two coats of exterior emulsion paint(Apex) over one coat of priming coat of alkali-resistant priming paint complete all as specified and directed.
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
S&F of rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete Fe 410-W (Gde-E- 250)quality-A, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F of rolled mild steel in 10043Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250)quality-A, complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.
S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 M in depth and getting out in ordinary soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified.
Removing excavated surplus materials to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point all as specified and as directed.
M&L for providing precast cement concrete solid block over 10 cm in width and setting in mortar 1:6 using pre cast cement concrete block 1:3:6 type C1 using 20 mm graded stone agg all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured.
Supply and laying reinforced precast concrete cable cover, class LV, type 1, flat, size 250mmx150mmx40mm complete.
Supply and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete.
Taking out carefully cable protection brick/cable cover from trenchs and reuse as cable protection cover complete location n.exc. 200 mtr away from site all as specified by Engineer-in-charge
Dismantling of HT cable from ground/transformer/OCB/Four pole structure and relaying carefully without damaging the cable complete location n.exc. 200 mtr away from site all as specified by Engineer-in-charge
Dismantling of insulators any type any size from existing poles all as directed.
Dismantling of unserviceable ACSR conductor of any type and size from existing broken poles at various location all as directed by Engr - in - charge at site.
Dismantling of cross arms (Clamp, nut bolts ),care fully from site complete all as specified and directed by Engr-in-charge.
Dismantling of existing earthing with galvanised steel strip 32x6 mm and 10/8 SWG wire complete including removing of PCC from site at various locations complete all as specified and directed by Engineer-in-chage.
Supply, install, testing and commissioning in replacement LT Busbar Panel board Outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and cable gland to incoming and outgoing cable with 2 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge.
Supply and fix security light DK Thermoplastic junction boxes of Dimension –[205 x 255 x 112]mm with aluminium bus bar of 100 Amps rating incl insulator , shockproof, rustproof, termite resistant, weather proof, with knockouts for cable entry , pole mounting arrangement including clamps,nuts & bolts of suitable size, IP 66, along with provision of Cable Glands incl three core copper cable with pvc conduit from junction box to LED fitting. Make :Hensel Code No KF 2525 G or equivalent.
Supply and Laying underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on pole with the help of GI Saddle of size 120 Sqmm 3.5 core as required at site.
Supply and Laying underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on pole with the help of GI Saddle of size 25 Sqmm 4 core as required at site.
Supply and Laying underground cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on pole with the help of GI Saddle of size 150 Sqmm 3.5 core as required at site.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including using 32 x 6 mm galvanized MS strip wire upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe 40 mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (a) Length of earthig connection incl GI strip and protection pipe more than 7.5 Mtr will be measured separately.
M&L U/S plate earthing with Chemical Earthing of 100% Copper Electrode of size (50X3000mm), terminal size:50/6, outer pipe diameter(min) 58mm, Inner strip : 25/3 with chemical bag of 50 Kg BFC at 3.3 mtr deep connected with by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified and testing on completion including all excavation & earth work in any type of soil/hard rock incl PCC pit (1:3:6) type C-1 with RCC complete all as directed at site. Note : Cost of excavation of soft/hard rock deemed to be included in the quoted rate.
Material and Labour for disconnection of existing Transformer 400 KVA by disconnecting electrically HT and LT Cable, dismantling of earthing and transporting carefully to Annexe (MES IB) with the help of crane and vehicle and reconnecting to HT/LT supply complete all as required at site and directed by Engr-in-Charge. Note : (i) Tool, machinery and transportation required for carry out of dismantling work and shifting of Transformer to Annexe (MES IB) will be arranged by contractor and rates for the same deemed to be included in quoted rate. (ii) Rate deemed to be included for removing of existing power house sheet for taking out of existing transformer and VCB and refixing it at its place after completion of the work. Note :- Before quoting the rates, contractor should check the site and scope of work.
Material and Labour for disconnection of existing OCB by disconnecting electrically HT and LT Cable, dismantling of earthing and transporting carefully to Annexe (MES IB) with the help of crane and vehicle and reconnecting it to HT supply complete all as required at site and directed by Engr-in-Charge. Note : (i) Tool, machinery and transportation required for carry out of dismantling work and shifting of Transformer to Annexe (MES IB) will be arranged by contractor and rates for the same deemed to be included in quoted rate. Note :- Before quoting the rates, contractor should check the site and scope of work.
Material and Labour for disconnection of existing LT Panel by disconnecting electrically LT Cable, dismantling of earthing and transporting carefully to Annexe (MES IB) with the help of crane and vehicle and reconnecting it to HT supply complete all as required at site and directed by Engr-in-Charge. Note : (i) Tool, machinery and transportation required for carry out of dismantling work and shifting of Transformer to Annexe (MES IB) will be arranged by contractor and rates for the same deemed to be included in quoted rate.
Material and Labour for disconnection of existing Security light timer by disconnecting electrically LT Cable, shifting carefully to Annexe (MES IB) includinng all necessary connection and fixing arrangement including clamps,nuts and bolts complete all as required at site and directed by Engr-in-Charge.
Material and Labour for carefully disconnection of existing LT Cable from LT panel , ground/wall and shifting to location as specified and directed by engr-in-chage including necessary electrical connection by using thimbles and lugs of suitable size complete all as required at site and directed by Engr-in-Charge. Note :- Excavation, removing, refilling of soil, filling of sand and cable cover will be mearued under suitable items.
M& L stay assembly with accessories as shown in Elect plate No- 01 complete with diameter of rod 20 mm . Note -loop type insulator , stay clamps , excavation and concrete will be measured and paid separately .
S&F loop type insulator, porcelain, vitreous white/brown or green of size 90 x 140 mm with clearance of hole 25.5 mm including taking down existing insulator complete all as specifed and directed by Engineer-in-charge.
M&L for galvanised stay strand 7/4 mm as stay wire including binding etc including taking down existing stay wire complete all as specified and directed by Engineer-in-charge
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts (E) grade, of size 3 core 95 sq mm.
M&L for cable jointing kit for 11000 volts grade HT cable with & including outdoor end termination type heat shrinkable jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sqmm x 3 core sizes complete all as specified and as directed.
M&L for cable jointing kit for 11000 volts grade HT cable with & including indoor end termination type heat shrinkable jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sqmm x 3 core sizes complete all as specified and as directed.
Material and Labour for 80 mm dia GI tubing medium grade incl. accessories for protection of cables on poles / under road crossing of following sizes.
Material and Labour for 50 mm dia GI tubing medium grade incl. accessories for protection of cables on poles / under road crossing of following sizes.
Material and labour for PCC cable path indicators with embosed on voltage, location and size of cable of 60cmx60cm size of indicator and embedded in PCC block (1:3:6) type using 20 mm grade stone aggregate including painting and earth work complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating, as directed and necessary form work complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces, rendering finished even and smooth includinng two coats of white paint (without using extra cement complete all as directed.
S& F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed by Engr-in-charge.
Note:- The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
GEETA CONSTRUCTION
SANJAY KAUSHIK
DEEP CHANDRA JOSHI
SANJAY SAW MILL
PRASAD PRADHAN AND SON
JAYSHREE CONCERN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .