Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹40.0 L+₹1.1 L (2.80%)Accepted-AOC | L2 | Accepted-AOC Other than lowest bid | |
| 3 | L3₹44.7 L+₹5.8 L (15.0%)Accepted-AOC | L3 | Accepted-AOC Other than lowest bid | |
| 4 | L4₹45.9 L+₹7.0 L (18.0%)Accepted-AOC | L4 | Accepted-AOC Other than lowest bid | |
| 5 | L5₹47.0 L+₹8.1 L (20.9%)Accepted-AOC | L5 | Accepted-AOC Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS
GE 874 EWS C/O 56 APO
SPECIAL REPAIR TO BLDG NO (EST-81) UNDER GE 874 EWS
2024_MES_660714_1
GE 874/EWS-43/2024-25
Open Tender
Civil Works
Works
90 days
KUPWARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 874 EWS C/O 56 APO
₹92,000
26 Oct 2024
19 Jun 2024
7 Sept 2024
20 Jun 2024
4 Sept 2024
24 Jul 2024
Amount
Demolition cement concrete (unreinforced) in ground floors and paving not exceeding 30 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
M & L for dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
Dismantling of mild steel cross arms of mild steel channel or angle sections etc complete setting aside for re-use in safe custody within 50 mtr distance complete all as specified and directed.
S & F in repair bird proof wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples, size of mesh 25x25 mm complete all as specified and directed.
M & L for removing excavated/demolition materials beyond 500 m upto 1.5 Km complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 as in foundation filling mass concrete and paving complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L preparation of new wall plastered surface and applying two coats of cement paint over a coat of primer complete all as specified and directed.
M&L for providing cement concrete in kerbs or mud stops, rounded or chamfered on edges 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in lintels uptp 1.5 mtr clear span, cills, steps and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm height, copings, kneelers, apex stone, bed plates and the like including weathering slightly rounded or chamfered angels and throating complete all as specified and directed.
M&L for rendering 15mm thick in cm (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.
S&F for Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer or hooks in roof wall etc complete all as specified and directed.
M & L for cleaning the joints to remove all loose dust, dirt oil laitance be removed by vacuum cleaning and filling dummy /contraction joint of size 10 mm width and 110 mm deep from top by applying epoxy primer Nito prime 25 and filling the joint in two parts with epoxy resin primer Nit floor TF 5000 of Fosroc or equivalent of Sika India Limited, Thermax Ltd BOSTIC India Pvt Ltd complete all as specified and directed. Note:-Only Joint filling work to be carried out in the existing joint cut in cement concrete floor.
Synthetic resin floor in hanger floor:- Surface preparation and primer application:-Material and labour for Surface preparation by cleaning the surface and removing dust, unsound or contaminated material, plaster, oil, grease, corrosion deposits or algae, oil and grease deposits by mechanical means. Floor to be cleaned by using all mechanised equipment such as scrubbers sanders, blowers, cleaners etc and priming the existing concrete surfaces with epoxy primer using NITRO PRIMER 25 @ 6sqm/litre on clean and dry surfaces, applied in a thin continuous film using roller all as per manufacturers instructions and as directed by Engineer in charge.
Under coat: Nito floor SL conductive primer under coat @ 6.3 - 7.3 sqm per litre.
Copper Strip: (10mm-25mm width x 0.05-0.01mm thickness) copper strip shall be fixed to floor framing 3mx3m grid and covering entire area.
Top coat: 2mm thick using Nito floor SL conductive Top coat @ 7.5 sqm per 15 litre pack.
Surface resistance in accordance with BS 2050 1976 (A‐1984) and DIN EN 1081, the Static conductive topping Gincl under coat shall be in the range of 5 x 10^4 ‐1 x 10^6 Ohms, When tested for static decay with +5 KV peak charge to 0% The surface resistance of the conductive under coat shall be in the range of 3 x 10^4‐ x 10^4 Ohms, The Cured film should have compressive strength of 34 N/MM2 and a flexural strength of 12 N/MM2 when tested as per BS 6319 compete all as specified and directed. (A)Cost of copper strip to connect earthing point for safe discharge charge shall be deemed to be included in the quoted rates. (B) Flooring shall be carried out as per manufacturers instruction and by the authorised applicators of the manufacturers MAKE: FOSROC / DR. CIPY / PEDILITE / BSF / BOSTIC / STP LTD / CHOKSEY CHEMICAL
M & L for 200 mm wide line marking with traffic guard line marking point as TLMP as approved by GE, min two coats over the epoxy coating floor topping, the paint should be applied after 5 days of application of floor topping complete all as specified and directed.
M&L for fabrication, erection and fixing structural steel work rolled mild section with riveted, bolted or welded complete all as specified and directed.
M&L for mild steel work Fe 410 A quality roof trusses (framed ), trussed, Purlins, crane gantries, rails, roller and fastenings and heavy bracket framing (Beam, Tee, angle, channel or flat /rolled sections)including distance pieces, cleats etc including welding rebated & screwing etc complete all as specified and directed.
M & L for 150 mm thick PCC (1:4:8) type D-2 as in sub floor, Sub bases, floors and paving’s complete all as specified and directed.
M & L for 150 mm thick PCC1:2:4 type B-2 (40 mm graded stone aggregate) as in Sub floors, Sub bases, floors and paving complete all as specified and directed.
M & L for forming contraction/Dummy joints 65 mm deep x10 mm wide, filled with sealing compound grade 'A" complete all as specified and directed.
M & L for providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portion) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make confirming to IS-733 & IS 1285 fixing with dash fasteners of required dia of size, including necessary filling up the gaps at junctions i.e.at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /panelling /C.P. brass/stainless steel screws, including taking down old unserviceable door/windows complete all as specified and directed.
S&F 4.8 mm thick plain sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed.
M&L for preparation of new steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for preparation of old steel surface and applying two coats of synthetic enamal paint complete all as specified and directed.
Taking down copper/aluminium point wiring (light fan, socket or power) complete including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions separately) and making good distributed surface of wall, floor etc complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC (FR-LS-H) insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC (FR-LS-H) insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/ fan point controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
M&L for wiring for one light point/Ex/fan point controlled by one switch with 2.5 sqmm PVC FR-LS-H insulated un-sheathed copper conductor single core multi strand cable and 1.5 sqmm PVC FR-LS-H insulated un-sheathed copper conductor single core multi stranded cable (green colour) as earth lead in and including cable 1100 volts grade PVC Conduit (ISI marked) for one light/ fan point controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per item No 30 herein before but wiring with 1.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board.
All as per item No 30 herein before but wiring with 1.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board.
All as per item No 30 herein before but wiring with 2.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
M&L for point wiring in PVC Conduit with 4 sqmm copper wire ( FR-LS-H) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board complete all as specified and directed.
S& F of 100W High Bay LED with PDC housing suitable for ceiling (surface/suspended) mounting with system efficiency up to 150 lm/Watt complete all as specified and directed.
S & F of 100W IP66 flood light suitable for highlighting architectural façade and general-purpose lighting complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fixing Switch piano type flush 6 Amp Single pole one way (ISI Marked) complete all as specified and directed.
Supply & Fixing Socket outlet 2 in1, 3 pin 5 Amps flush type complete all as specified and directed.
S & F switch socket combination 2 in 1,5A, flush type complete all as specified and directed.
S & F switch socket combination 5 pin 16A, flush type completes all as specified and directed.
Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
Supply and fixing of Industrial insulated plug and socket 63A 3P+N and earthing complete all as specified and directed.
Supply and fixing of MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fixing of MCCB 3 Pole, 415 V, Adjustable type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB’s, made out of sheet steel enclosure, recessed type, factory made powder coated 4 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB’s, made out of sheet steel enclosure, recessed type, factory made powder coated 12 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
Supply & Fixing RCBO, single pole and neutral (SPN) 30mA, 240V, 63 Amp complete all as specified and directed.
Supply & Fixing RCBO, single pole and neutral (SPN) 30mA, 240V, 32 Amp complete all as specified and directed.
Supply and fixing 6 to 32amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3cm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test all as specified or indicated including testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3cm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to but using galvanised iron strip 32×6mm as earthing lead dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test all as specified or indicated including testing on completion complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for sand cushioning to underground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed. Note: Thickness of sand after punning 18 Cm shall be measured and paid.
M&L for brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay in replacement of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed.
Supply and fixing of GI Tubing medium grade of 80mm nominal bore of pipe in trenches/under roads/ under culverts/under paths/under floor on walls/with pole in new position with screwed sockets joints together with all tube fittings complete all as specified and directed.
RATHER BROTHERS (BID ID -3081378)
M/S MOHD YOUSUF CONSTRUCTION CO (BID ID -3083040)
M/S MUNEER AHMAD WANI CONSTRUCTIONS (BID ID -3082709)
MS RJ BUILDERS (BID ID -3083201)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .