Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹25.8 L+₹30,544.75 (1.20%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹26.4 L+₹95,928.75 (3.77%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹28.8 L+₹3.3 L (13.1%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical As per Para 7 of NIT original DD and application uploaded with tender not recd by this office till date hence it is recommended that T Bid to be rejected please |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 Jun 2023, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD
ADDN/ALTN AND SPECIAL REPAIRS TO BLDG NO P-121 (DSC MD ACCN) AND P-10 (GUARD ROOM) AT HQ 31 WEU THANE UNDER GE (NW) MANKHURD
2023_MES_597877_1
8228/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹84,000
28 Sept 2023
24 May 2023
29 Jun 2023
24 May 2023
27 Jun 2023
2 Jun 2023
Amount
Taking down cement plaster on brick or concrete surfaces etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brickwork or concrete surfaces in CM 1:6, finished the surfaces even & smooth including 1mm thick sagol finish complete all as specified.
M&L for rendering 20mm thick in cement mortar 1:4 on brick or concrete surfaces, on walls, laid in two layers, 1st layer 15mm thick and finishing layer 5mm thick mixed with integral water proofing compound @2 % by weight of cement content of finishing layer, finished fair and even without using extra cement , additional thickness provided as floating/setting coat, including all necessary scaffolding / staging as required complete all as specified and as directed by the Engineer-in-charge at any position.
M& L rendering 10 mm thick in CM 1:3 on ceiling surface finished even & smooth with sagol finish complete all as specified.
Supply only integral water proofing compound.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit, upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit while the bonding agent is still tacking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers, each layer not exceeding 20mm, including levelling, profiling etc, complete all as specified and directed.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. [Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.]
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed. Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.
M & L preparing new surfaces of walls applying two coat of oil bound distemper over 3mm thick wall care putty complete all as specified & directed by EIC.
M& L for preparation of newly plastered surface and applying three coat of white wash on ceilings complete all as specified and directed
M & L for preparing old decorated surfaces of wall (plasterered or unplastered or previously white washed) & applying two coat of oil bound distemper complete all as specified.
M & L for preparing old decorated surfaces of ceilings(plastered or unplastered or previously white washed) & applying three coats of whitewash complete all as specified.
Material & Labour for preparation of new and old plastered surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed.
S & F in repairs harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc
S & F in repairs Vitreous China wash basin, white, flat back, size 580x450 mm including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S&F floor door stopper aluminium body over length of cover plate 140 mm and tonque anodised with hard drawn steel spring fixed in floor complete all as specified and directed.
Taking down carefully aluminium sliding window shutters including existing rubber gasket completed and re-fixing the shutters same in existing position after replacement of broken glass/stainless steel wire mesh with rubber gasket and area of window exc 1.20 sqm but not exc 3.78 Sqm in each including necessary scaffolding etc complete all as specified and directed.
Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix New locking arrangement in place of old one and re-fixing the same shuters in existing position after repair work or replacement of new locking arrangement and necessary scafolding etc complete all as specified and directed
S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S & F in repairs aluminium anodised grill DG-104/DG-102 10 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building complete all as specified. (Make:- Deco Grill or equivalent)
Supply only 3.00 mm thick sheet glass, ordinary quality, in squares not exc 0.5 Sqm each pane, complete all as specified.
S&F inrepair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples Stainless steel wire cloth. 0.36mm nominal dia of wire and verage width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exceeding 1.5 Sqm each including complete all as specified and directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but not exc 4 Sqm each including complete all as specified and directed.
S& F second class hard wood , plain ,soild ,straight chowkats and frames, wrought , rebated on soild rounded or chamfered , put together with gule pinned at joints etc complete all as specified .and directed
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as per specification given under SSR Part II 2010 including making good the disturbed surface all as specified and directed.( Make: SYNTEX/SHALIMAR/RAJSHRI)
M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2010 complete all as specified and directed. Make : SYNTEX/SHALIMAR/RAJSHRI
S&F 35 mm thick plain , framed ,panelled shutters ( any number of panels),in 2nd class hardwood,with panels of timber flat on both sides (feather edged) ,or of veenered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified.
S & F 35 mm thick glazed and skeleton shutters, in 2nd class hardwood, open rebated and prepared to receive glass, gauze etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a)
M& L for preparation of newly or previously untreated surfaces of wood or wood based surfaces of any description not other wise described , over10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed.
M& L for preparation of old surfaces wood or wood based surfaces of any description not other wise described , over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed.
S&F extruded aluminum alloy handles (150mm ) fabricated type anodised complete all as specified Make :- Shalimar / jyoti/ Classic/ Ashoka
S&F hinges (150 mm) stainless steel medium weight complete all as specified
S&F in repairs aluminum anodised barrel tower bolts (150 mm ) of extruded section complete all as specified
S&F in repairs 300 mm Aluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar, hedding removing serviceable tiles to store and rubbish off the premises all as specified and directed .
M&L non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors over screed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
Description all as per Serial item No 40 here-in-above but screed bed or bedding layer of morar 10 mm in cement mortar 1:4 on walls surfaces, such as skirting, to slab etc. complete all as specified and as dircted.
M&L for coloured Non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
S& F coloured glazed ceramic tiles 350 x 250 x 7mm/450x350x7mm thick in dado/ skiting etc set and jointed in neat cement slurry and pointed in coloured cement to match, over and incl 10mm thick backing coat in CM 1:4 complete all as specified and directed .
M & L for machine cut cudappah stone slab as in window cills and jambs 20 mm thick to full thickness of wall fixed in steps over cement screed bed 20mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed
M&L for Kota stone slabs, 20mm to 25mm thick, machine cut as in flooring of size not less than 0.25 Square metre each, set and jointed in cement slurry and pointed in cement mixed with pigment to match the shade of slab laid over & including screed bed of 15 mm thick in cement mortar (1:4) including rubbing, cutting and polishing (mirror type), complete all as specified.
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick cement mortar screed bed in CM 1:6 etc,complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations over rendering 10 mm thick in CM 1:6 on brickwork or concrete surfaces complete all as specified and directed.
S&F in repairs 15mm bore bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
S&F in repairs 15mm bore stop valve cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as specified & directed
S&F in repairs 15mm bore pillar taps,chromium plated, cast copper alloy screwed high pressure with crutch or butterfly handle, screwed both end for iron pipe or for union complete all as directed.
S & F in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) in repairs complete all as specified and directed
M&L Grating doom 100mm dia of PTMT (Minimum weight 25gms) in repairs complete all as specified and as directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm
S&F cast iron Nahani trap 100mm dia out let including grating connecting jointing to waste pipe with lead jointing and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
Disconnecting following size of existing tanks, stacking safely for re-use (or lowering if required) and hoisting, reconnecting and refixing in position complete all as specified. (a) up to 1000 litres capacity.
Taking up or down steel tubing and connections, including cleaning serviceable pipe for refixing and balance under schedule of credit all as specified and directed (a)15mm bore
(b) 20 mm bore
S&F GI Steel tubing medium grade with all fitting & fixed complete to walls & ceiling or laid in floors complete all as specified for the following size :- (a)15 mm bore
(b) 20 mm bore
Fixing only GI steel tubing medium grade with all fitting & fixing to walls/ceiling or laid in floor and complete all as specified for the following size :- (a)15 mm bore
(b) 20 mm bore
Taking down pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc, including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories)
S & F 110mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls
All as per item No 64, above but 75mm dia
S&F PVC (SWR) bends of 110mm bore.
S & F 75 mm dia bend
S&F 75mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal
S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. complete all as specified and as directed
M&L for special treatment of sunken portion of WCs and Bath room as per following stages: Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:- Making holes in wall and fixing 600mm long 20mm dia GI spout for draining the surplus water if any.
M & L for cement concrete 1:5:10 Type E2 (using 40mm graded stone aggregate) as in filling in sunken floor etc complete all as specified and directed.
S & F Wash down water closet (Pedestal pattern), complete white (excluding fixing bolts, flushing cisterns and flush pipe) complete all as specified and directed by EIC.
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC as per manufacturer's instructions, complete all as specified and directed.
Supply only liquid water proofing compound, complete all as specified and directed.
M & L for APP modified roof treatment over existing roof slab etc including taking down to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sq cm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (d) Over the membrane provide a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/Sqm as prescibed by manufacturer.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed .
S&F 18/19 mm thick prelaminated particle board both sides , interior grade , of approved shade and pattern fixid with screws to timber frame with beading piece for cupboard and shelves complete all as specified
S & F for continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps 30mm (when open) complete all as specified and directed.
S & F for 125mm aluminium handles, cast type, anodised complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thick (above or below ground level) and removing the debris outside MD land complete all as specified
Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified
M&L 25 mm thick Cement concrete type B 2, 1:2:4 (using 20 mm graded crushed stone aggregate) in base of flooring complete all as specified
M& L for Chequered cement concrete tiles 20cm x 20 cm x 25 mm thick, set, jointed and pointed in near cement slurry in floors with mixture of white cement andno pigment over screed bed or bedding layer of mortar 15 mm in cement mortar 1:6 complete all as specified and as directed.
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling etc. in repiars with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch.
-Ditto- all as per item No 87 above but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
-Ditto- all as per item No 87 above but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 87 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board
S&F in repairs modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S&F in repairs modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F in repairs modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F in repairs modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.
S&F in repairs modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
Supply & Fix in repairs Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.
Supply and fix in repairs bell ding dong AC 230 V single pole. complete all as specified and directed.
S & F in repairs Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed
S & F in repairs Modular cover plate 8 modules
S & F in repairs Modular cover plate 4 modules
S & F in repairs Modular cover plate 3 modules
S & F in repairs Modular cover plate 2 modules
S & F in repairs Modular cover plate 1 modules
S&F in repairs ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.
S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 20/22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed
S & F in replacement of 36 W ceiling recessed light of size (2x2 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.5 mfd - 01 No., PVC canopy - 02 No and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
S & F in replacement MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F in replacement MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity
S & F in replacement MCB SP 6 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity
M&L in repairs for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
S&F in repair/replacement of building Security light fitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge.
S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
Taking down old unserviceable exhaust fan 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs for rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.5 mfd - 01 No and bearing including scrapping of old paint and applying two coats of synthetic enamelled grey paint over a coat of red oxide primer complete and refixing back at site complete all as directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified.
M & L in repairs for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
Supply and fixing in replacement of LED bulkhead light fitting 10 watt, 220 V AC, CCT 5700 with K opal diffuser, equipped with 2 kv in built surge protection with IP 65 protection rating including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed
Supply and fix in repair MCCB 100 Amp 4Pole 415 Volt 25KA with and including CRCA powder coated 2mm thick enclosure with front openable door wall mounted type with chequred base plate for cable entry,including taking down of old MCCB of any size and reconnecting the cable with proper gland Note : A sum of Rs 27924.00 towards sch of credit shall be deducted to arrive the contract sum.
Vishal Builders
Joy builders
Parmatma Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .