Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAdmitted-Finance BANSAGAR COLONY REWA DISTT REWA M P | REWA | MADHYA PRADESH | 486001 | ₹14.3 L | L1 | Admitted-Finance |
| 2 | L2₹12.9 LAdmitted-Finance | ₹12.9 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NATIONAL TRADERS L1 | reflection L2 |
|---|---|---|---|---|---|
| 1.00SCAN COPY OF ESTIMATE IS ATTACHED SEPERATELY. | |||||
| 1.01 | fabrication and installation of MS/SS steel letters | 1 | LS | 1,47,000 ₹1.5 L | 1,32,447 ₹1.3 L |
| 1.02 | Round flood light, 50W, 2140 lumens ±10%, 10° beam ±10%, RGBNW:
Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 2140 lumens ±10%, 10° beam angle ±10%, CCT-3000K ±150K. LED from
CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high- voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS- certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This
includes all the required hardware for the successful operation | 10 | Nos | 35,000 ₹3.5 L | 31,535 ₹3.2 L |
| 1.03 | Accessories - Supply, Laying, Connecting, Testing &
Commissioning Leader Cable - Controller to First Luminaire 4P DMX cable 2m (10 pcs set) | 10 | Nos | 2,125 ₹21,250 | 1,914 ₹19,140 |
| 1.04 | Accessories - Supply, Laying, Connecting, Testing & Commissioning Jumper Cable - Luminaire to Luminaire 4P DMX
cable 2m (10 pcs set) ; | 10 | Nos | 2,500 ₹25,000 | 2,252 ₹22,520 |
| 1.05 | Accessories - Providing & fixing Endcap male connector (20 pcs) | 20 | Nos | 625 ₹12,500 | 563 ₹11,260 |
| 1.06 | Accessories - Providing & Fixing Endcap female connector (20
pcs) ; | 20 | Nos | 625 ₹12,500 | 563 ₹11,260 |
| 1.07 | Round flood light, 50W, 18G5 lumens ±10%, 45° beam ±10%, RGBNW:
Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 1895 lumens ±10%, 45° beam angle ±10%, CCT-RGBNW. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high- voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS- certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This
includes all the required hardware for the successful operation | 4 | Nos. | 35,000 ₹1.4 L | 31,535 ₹1.3 L |
| 1.08 | Supply, Laying, Connecting, Testing & Commissioning Leader
Cable - Controller to First Luminaire 4P DMX cable 2m | 10 | Nos | 2,125 ₹21,250 | 1,915 ₹19,150 |
| 1.09 | Supply of Content Program Controller with features of Single DMX ports control minimum 300 light addresses, Works as a stand-alone or computer-driven controller, Secure Digital (SD) card drive for flexible show storage, USB 2.0 interface for downloading shows and configuring from attached PC,Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100-240VAC,Minimum Five pre configurable effects :Using light authoring software to select from five pre-defined effects, adjust effect settings such as color, speed, and brightness. Soft Copy of Catalogues with Link of the official web page of Luminaries, Test Certificates - relevant BIS R Number, UL Certificates, Third Party IEC 60598 test certificates submission
is mandatory. | 1 | Nos | 1,70,000 ₹1.7 L | 1,53,170 ₹1.5 L |
Tender Value
₹31.3 L
EMD Value
₹23,502
Closing Date
9 Feb 2026, 6:00 pmClosed
COMMISSIONER
OFFICE OF THE MUNICIPAL CORPORATION REWA, NEAR STATUE CHOWK, BESIDE OF PADMADHAR PARK, VYANKAT ROAD, WARD-18, REWA (M.P.)
EXECUTION OF CIVIL, ARCHITECTURAL, FACADE LIGHTING AND BEAUTIFICATION WORKS OF ENTRY GATE AT CHORHATA BYPASS IN MUNICIPAL CORPORATION REWA (M.P.)
2026_UAD_473939_1
888/E-Tender/RMC/2026, Rewa Date 07.01.2026
Open Tender
Civil Works - Others
60 days
OFFICE OF THE MUNICIPAL CORPORATION REWA (M.P.)
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹23,502
23 Feb 2026
8 Jan 2026
11 Feb 2026
8 Jan 2026
9 Feb 2026
8 Jan 2026
8 Jan 2026 - 22 Jan 2026
SCAN COPY OF ESTIMATE IS ATTACHED SEPERATELY.
fabrication and installation of MS/SS steel letters
Round flood light, 50W, 2140 lumens ±10%, 10° beam ±10%, RGBNW: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 2140 lumens ±10%, 10° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high- voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS- certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation
Accessories - Supply, Laying, Connecting, Testing & Commissioning Leader Cable - Controller to First Luminaire 4P DMX cable 2m (10 pcs set)
Accessories - Supply, Laying, Connecting, Testing & Commissioning Jumper Cable - Luminaire to Luminaire 4P DMX cable 2m (10 pcs set) ;
Accessories - Providing & fixing Endcap male connector (20 pcs)
Accessories - Providing & Fixing Endcap female connector (20 pcs) ;
Round flood light, 50W, 18G5 lumens ±10%, 45° beam ±10%, RGBNW: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 1895 lumens ±10%, 45° beam angle ±10%, CCT-RGBNW. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high- voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS- certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation
Supply, Laying, Connecting, Testing & Commissioning Leader Cable - Controller to First Luminaire 4P DMX cable 2m
•¾Addressing Kit shall automatically write address to a whole group of interconnecting luminaires within minutes. It shall be Miniature industrial design, compact size and touch screen. It can be powered by a power bank with a Micro-B type USB port for on-site programming and testing after installation. The housing shall be extruded Aluminum with black finish weighing approx. 0.2Kg with temperature range -10°C to 40°C, input voltage of 6-24V DC and humidity range of 10 to 90% (no condensation). The product shall be compact in size, compatible with multiple types DMX512 chips, with Built-in test animation effects, SD card slot to store animation and scenes. The addressing kit shall support standard RDM protocol, searching for RDM luminaires and static detection, Color-pick functions, and can be powered by Micro-B type USB power supply.
SITC of PVC insulated multi core electrical un armoured flexible 3C x 2.5Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V.
SITC of sub Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and ivory connectors for the internal terminations and external outgoing connecting points, fiber / brass glands of suitable size fitted MCB control for outgoing circuits. - 2 Nos of 16A TPN Outgoing MCB's. - 1No of 32A TPN Incoming MCB.
SITC of IP driver box made up of UPVC/PVC fabricated housing and ivory connectors for the internal terminations and external outgoing connecting points.(For diver box)
SITC of Programmes pertaining to permanent decorative illumination including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.
SITC of PVC insulated multi core electrical armored flexible 4C x 4 Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands aluminum conductors and it supports voltage grade up to 1100V. (As peractuals depending upon the site condition)
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG- MA/CON ( 1-2-5 ) ( 2022-23 )
Supplying, erecting s terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands s lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( 7-1-28 ) ( 2022-23)
Supplying and laying (including excavation of suitable width s depth up to 60 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.( 7-6-6 ) (2022-23)
Providing earthing with galvanized iron earth plate size 60 x 60x 0.6 cm complete with all materials, testing s recording the results as per specification no. EA-EP ( 6- 1-1 ) ( 2022-23)
SITC of GI Cage for light protection, GI Cage made of mesh with back openable door and suitable hinges, light fixing provision with bolting option, base concretefoundation.
SITC of 5 core DMX cable comprises twisted pairs with shield support for carrying of data. DMX512 cable is used for connecting all light consoles that use DMX 512 standard data transmission. Beldon / Falcan or Cat6 cable of Dlink make
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SCAN COPY OF ESTIMATE IS ATTACHED SEPERATELY.
EXECUTION OF CIVIL, ARCHITECTURAL, FACADE LIGHTING AND BEAUTIFICATION WORKS OF ENTRY GATE AT CHORHATA BYPASS IN MUNICIPAL CORPORATION REWA (M.P.)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
888_Estimate_EntryGatechorhta.pdf
Tender Documents • 2.69 MB
888_Tender_Doc_Entry_Gate_Chorhta_1st_Call.pdf
Tender Documents • 1.18 MB
BOQ_557332.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid