| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC | L1 | Accepted-AOC the contract amount is awarded to M/S KALSI ENGINEERS AND CONTRACTORS | |
| 2 | L2₹67.8 L+₹9.9 L (17.1%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance being other than lowest | |
| 3 | L3₹70.6 L+₹12.7 L (22.0%)Rejected-Finance | L3 | Rejected-Finance being other than lowest | |
| 4 | L4₹72.3 L+₹14.4 L (24.8%)Rejected-Finance | L4 | Rejected-Finance being other than lowest | |
| 5 | L5₹84.2 L+₹26.3 L (45.5%)Rejected-Finance | L5 | Rejected-Finance being other than lowest |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L2 | Sarbat Construction Co L4 | M/S KALSI ENGINEERS AND CONTRACTORS L1 | PROACH ASSOCIATES BUILDERS & ENGINEERS L3 | M/S S K Electricals Regd L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Inspection of defective step down 11 KV / 0.433 upto 500 KVA transformer any make, installed on plinth/floor/pole mounted, indoor/outdoor type, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site (Nagrota, Katra & Sanjhi Chatt) except major fault of burnt winding or other. The following tasks if required will be performed :-
(a) Step opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer.
(b) Replacement of defective HT/LT bushes, spindles etc.
(c) Refixing the transformer top cover with nuts, bolts and washers.
(d) Testing of transformer Complete.
Note : (i) In case of replacement of LV / HV bushing / spindles / tap changer etc, will be measured and paid for separately under relevant items
(ii) Transformer oil (if required) for topping will measured and paid for separately under relevant item | 25 | Each Job | 1,000 ₹25,000 Lowest | 3,000 ₹75,000 | 1,000 ₹25,000 Lowest | 8,000 ₹2,00,000 | 1,500 ₹37,500 |
| 2.01 | M&L for taking down transformers mounted on two/four pole structure or on platform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc, for executing necessary comprehensive preventive maintenance as well repairs necessiated, including to and fro transporting to Workshop, and refixing & testing after execution of maint/repair to their original position or to other location as directed of capacity as under: -
(a) Step down transformer 11 KV/0.433 KV of any make of capacity 40 KVA to 160 KVA. | 10 | Each Job | 2,500 ₹25,000 | 3,500 ₹35,000 | 1,000 ₹10,000 Lowest | 4,000 ₹40,000 | 1,500 ₹15,000 |
| 2.02 | (b) -do- but capacity exceeding 200 KVA but n.exc 500 KVA | 15 | Each Job | 5,000 ₹75,000 | 4,500 ₹67,500 | 1,000 ₹15,000 Lowest | 4,000 ₹60,000 | 2,000 ₹30,000 |
| 3.00 | M&L for dismantling core, taking out damaged coils (HV Coils) from its position for replacement, including supplying and fixing new winded coils with super enamelled copper winding wires of reqd gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge. | 1,750 | Kgs | 1,030 ₹18,02,500 | 650 ₹11,37,500 Lowest | 1,000 ₹17,50,000 | 950 ₹16,62,500 | 1,150 ₹20,12,500 |
| 4.00 | M&L for Reconditioning of LT side coils from its position for replacement including supplying and fixing new winded coils with cotton braided copper wire or strip of approprite size (thickness & breadth) number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed. | 1,478 | Kgs | 700 ₹10,34,600 | 90 ₹1,33,020 | 60 ₹88,680 Lowest | 260 ₹3,84,280 | 1,100 ₹16,25,800 |
| 5.00 | Taking out HV procelain bushes from transformers for replacement being damaged, including supply and fixing new HV procelain, viterous white, brown or green of voltage grade 11000 V bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 500 KVA indoor complete all as specfied and directed. | 45 | Each | 150 ₹6,750 Lowest | 250 ₹11,250 | 300 ₹13,500 | 300 ₹13,500 | 150 ₹6,750 Lowest |
| 6.00 | Taking out LV procelain bushes from transformers for replacement being damagd, including supply and fixing new HV procelain, viterous white, brown or green of voltage grade 1100 V bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 500 KVA indoor/out door complete all as specfied and directed. | 51 | Each | 100 ₹5,100 Lowest | 250 ₹12,750 | 300 ₹15,300 | 500 ₹25,500 | 150 ₹7,650 |
| 7.00 | Taking out worn out HV metallic alloy(brass/gun metal) bush rods, incl supply and fixing new HV metallic alloy (gun metal/brass)bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 40 KV A to 160 KVA complete all as specfied and directed. | 15 | Each | 250 ₹3,750 | 750 ₹11,250 | 500 ₹7,500 | 600 ₹9,000 | 200 ₹3,000 Lowest |
| 8.00 | All as per srl item No 7 here-in-above but for transformer of cap exceeding 200 KVA but not exc 500 KVA. | 30 | Each | 250 ₹7,500 Lowest | 750 ₹22,500 | 500 ₹15,000 | 700 ₹21,000 | 250 ₹7,500 Lowest |
| 9.00 | Taking out worn out LV metallic alloy (brass/gun metal) bush rods, including supply & fixing new LV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 40 KVA to 160 KVA | 18 | Each | 500 ₹9,000 | 750 ₹13,500 | 500 ₹9,000 | 1,400 ₹25,200 | 200 ₹3,600 Lowest |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
20 Aug 2025, 6:00 pmClosed
CWE NAGROTA
HQ CWE NAGROTA
REPAIR/ MAINTENANCE OF POWER TRANSFORMER, TRANSFORMER, VOLTAGE STABLIZER ALONGWITH OTHER CONNECTED ITEMS UNDER GE NAGROTA
2025_MES_720710_1
CWE/NGT-10/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE NAGROTA
₹1.4 L
Yes
19 Sept 2025
16 Jul 2025
28 Aug 2025
16 Jul 2025
20 Aug 2025
6 Aug 2025
16 Jul 2025 - 31 Jul 2025
Amount
Inspection of defective step down 11 KV / 0.433 upto 500 KVA transformer any make, installed on plinth/floor/pole mounted, indoor/outdoor type, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site (Nagrota, Katra & Sanjhi Chatt) except major fault of burnt winding or other. The following tasks if required will be performed :- (a) Step opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer. (b) Replacement of defective HT/LT bushes, spindles etc. (c) Refixing the transformer top cover with nuts, bolts and washers. (d) Testing of transformer Complete. Note : (i) In case of replacement of LV / HV bushing / spindles / tap changer etc, will be measured and paid for separately under relevant items (ii) Transformer oil (if required) for topping will measured and paid for separately under relevant item
M&L for taking down transformers mounted on two/four pole structure or on platform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc, for executing necessary comprehensive preventive maintenance as well repairs necessiated, including to and fro transporting to Workshop, and refixing & testing after execution of maint/repair to their original position or to other location as directed of capacity as under: - (a) Step down transformer 11 KV/0.433 KV of any make of capacity 40 KVA to 160 KVA.
(b) -do- but capacity exceeding 200 KVA but n.exc 500 KVA
M&L for dismantling core, taking out damaged coils (HV Coils) from its position for replacement, including supplying and fixing new winded coils with super enamelled copper winding wires of reqd gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge.
M&L for Reconditioning of LT side coils from its position for replacement including supplying and fixing new winded coils with cotton braided copper wire or strip of approprite size (thickness & breadth) number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed.
Taking out HV procelain bushes from transformers for replacement being damaged, including supply and fixing new HV procelain, viterous white, brown or green of voltage grade 11000 V bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 500 KVA indoor complete all as specfied and directed.
Taking out LV procelain bushes from transformers for replacement being damagd, including supply and fixing new HV procelain, viterous white, brown or green of voltage grade 1100 V bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 500 KVA indoor/out door complete all as specfied and directed.
Taking out worn out HV metallic alloy(brass/gun metal) bush rods, incl supply and fixing new HV metallic alloy (gun metal/brass)bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 40 KV A to 160 KVA complete all as specfied and directed.
All as per srl item No 7 here-in-above but for transformer of cap exceeding 200 KVA but not exc 500 KVA.
Taking out worn out LV metallic alloy (brass/gun metal) bush rods, including supply & fixing new LV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 40 KVA to 160 KVA
All as per srl item No 9 here-in-above but for transformer of cap exceeding 200 KVA but not exc 500 KVA
Inspection of defective Servo Voltage stablizer of capacity 50 KVA upto 300 KVA of any make any type by step opening, removing the top cover of stablizer, detecting the fault, rectfying the defect at site (Nagrota, Katra & Sanjhi Chatt) except major fault of burnt dimmer coil, burnt servo motor. The following tasks if required will be performed :- (a) Opening of the Voltage stablizer and removing the top cover for checking/rectified the faults of the servo voltage stablizer. (b) Replacement of defective/ burnt wires and checking external connections. (c) Refixing the top cover with nuts, bolts and washers. (d) Testing of Voltage stablizer Complete. Note : (i) In case of replacement of dimmer Coil, Servo motor, Toggles switch, PCB etc, will be measured and paid for separately under relevant items (ii) Oil (if required) for topping will measured and paid for separately under relevant item
Supply and fix in repair/replacement digital voltmeter 0 to 500 volts 96 x 96mm, flush type, complete all as specified and directed.
Supply and fix in repair/replacement LT current transformer as suitable for servo voltage stabilizer of capacity 50 to 300 KVA complete all as specified and directed.
Supply and fix in replacement only PCB card/ plate for automatic voltage correction suitable for servo stabilizer of capacity 50 to 300 KVA, of type and make as per site requirement, complete all as specified and directed.
Supply and fix in repair/replacement micro limit switch with cam lever for servo stabilizer of capacity 50 KVA to 300 KVA of type and make as per site requirement, complete all as specified and directed.
Supply and fix servo motor, synchronous type, of torque capacity 30 Kg for automatic voltage correction, suitable for servo stabilizer of capacity 50 KVA to 300 KVA of type and make as per site requirement, complete all as specified and directed.
Supply and fix over load relay suitable for 50 to 300 KVA voltage stabilizer complete all as specified and directed.
Supply and fix servo dimmer/booster coil of suitable capacity for automatic voltage correction suitable for servo stabilizer of capacity 50 KVA to 160 KVA of type and make as per site requirement, complete all as specified and directed.
Supply and fix servo dimmer/booster coil of suitable capacity for automatic voltage correction suitable for servo stabilizer of capacity 200 KVA to 300 KVA of type and make as per site requirement, complete all as specified and directed.
Supply and fix terminal connections with brass Rod with Bush suitable for servo stablizer of capacity 50 KVA to 300 KVA of any type and make as per site requirement, complete all as specified and directed.
Servicing of 33/11 KVA up to 6.3 MVA Power transformer outdoor type externally included all accesories such as ( conservator tank, marshalling box , bushing, buchholz relay radiator, oil level indicator ) complete and checking the outgoing and incoming terminal connection complete with following testing. a) Transformer oil testing dielectric strength testing.b) Buchholz relay alram test and trip testing. c) Oil tempreature alarm and trip testing.d) Winding temperature alarm and trip testing. e) Meggar testing between HV and Earth. f)Meggar testing between LV and Earth g)Meggar testing between HV and LV h)Earth Resistance test of transformer neutral i)Earth Resistance test of transformer body Note : Contrator shall provide the Testing result to engineer- in- charge
Filteration, heating and dehydration of transformer oil ( at Site ) on load system, EHV grade having dielectric strength not less than 60 KV with 2 mm gap high viscosity in transformer of cap 40 KVA to 500 KVA as per IS-335 of 1983. The reducing moisture, acidity carbon particle in transformer Oil.Note :- The filtration, heating and dehydration of transformer oil shall be carried out site. The unit rate quoted by the contractor shall deemed to include for arrangement of filtration machine and its transporation to various location of installation of transformer and top up of transformer oil.
Supply, treating (dehydrating), filling new transformer oil in transformers for topping up levels or for replacement of unfit oil .New oil having dielectric strength not less than 60 KV at 2mm Gap and shall be confirming to IS 335. Note : The Empty Barrel is the property of department. Supply should be given in Sealed Containers.
Taking out old breathers from transformer, supplying and fixing new breather duly filled with activated agent i.e silcagel for transformer of cap 40 KVA to 500 KVA
M & L for repair and replacement for tap changing gear , including minor repair and supply & fixing, making connections, testing & commissioning tap changing gears in transformers of any description / rating and make complete all as specfied and as directed.
M&L in repair of transformer platform of size 2.50 m x 2.50m x 1.20m with following specifications as under ( As Per Techanical drawing of Platform) a)Brick work in sub class B brick old size burnt clay bricks exc 6m mean radius on plan in cement mortar 1:4 complete all as spd and directed b) PCC 1:3:6 type C2 as in foundation filling and mass concrete c) Stone boulder filling n.exc 63mm including hand packing and well ramming complete d) PCC 1:2 :4 type B1 as in flooring / top surface of plate form complete e) Plastering to brick work in CM 1:4 complete, 15mm thick f) Angle iron of size 50mm x 50mm x 6mm as in post for fencing g)Mild Steel galvanised Chain link fencing with mesh size 50mm x 50mm, dia of wire 4mm Note : During platform repair Contractor shall arrange the Hydra Machine for Lifting the transformer from Existing platform to Near by locations with temporary fencing around it.
Mild steel work as in framed structure (around 4 pole/2 pole/ LT pannel/ Transformer) guard bars, framed balusters and similar works complete including PCC work as in foundation complete all as specified.
Expended metal cut to length, bend to required shape weight not less than 4 kg/Sqm and laying with and including annealed MS wire or welded to steel members complete all as specified.
Material and labour for spreading and leveling evenly (any thickness) 20 mm graded stone aggregated complete all as specified and directed.
Material and labour for spreading and leveling evenly (any thickness) 40 mm graded stone aggregated complete all as specified and directed.
Labour and tools for trimming tree branches up to 100 mm grith of any location around existing HT/LT OH lins and any no conductors giving clearance of 1.5 m on all sides after arranging shut down and taking all precaution while working on lines incl all T&P required for the purpose complete all as specified and diected by Engineer-in- charge. Note : The contractor shall arrange the tree cutting machine and vehicle mounted telescopic ladder for the same.
Earthing complete with galvanised steel earth plate electrode 60cm ×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using galvanised iron strip 25×4mm as earthing lead connected to using galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr In Charge.
Supply and fixing in repair of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm.
Description same all as per srl item No 35 here-in-before but for cable of cross sectional area 120 to 185 sqmm outdoor type
Description same all as per srl item No 35 here in before but outdoor joint for cable of cross sectional area 240 to 300 sqmm
Supply and fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm outdoor type
Description same all as per srl item No 37 here in before but for cable of cross sectional area 120 to 185 sqmm outdoor type
S& F in replacement Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV complete in repairs including taking out old unsv GOD complete all as specified.
S& F in replacement Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (12 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV complete in repairs including taking out old UNSV GOD complete all as specified.
S&F in replacecment Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground levelconfirming of IS 1818 of 1972 and contineous current rating upto 400 amp and volt 11 KV complete in repairs including taking out old UNSV GOD complete all as specified.
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping/above ground level around the pole etc including necessary formwork complete all as specified.
Steel tubular swaged pole type 410 SP-55 (11 mtr long) with 300x300x6mm mild steel plate continuously welded to pole , finial taper plug, bolts, nuts and screws complete all as specified and directed including painted with black bituminous paint internally and externally with anti corrosive paint in alternate black and white strips 30 cm each up to 1.5 mtr height from top edge of concrete and remaining pole with two coats of aluminium paint over a coat of red oxide primer including writing the number etc complete all as specified and directed by Engineer-in-charge. Note: Excavation and Earth work, PCC in foundation and copping shall be measured and paid separately.
Steel tubular swaged pole type 410 SP-31 (09 mtr long) with 300x300x6mm mild steel plate continuously welded to pole , finial taper plug, bolts, nuts and screws complete all as specified and directed including painted with black bituminous paint internally and externally with anti corrosive paint in alternate black and white strips 30 cm each up to 1.5 mtr height from top edge of concrete and remaining pole with two coats of aluminium paint over a coat of red oxide primer including writing the number etc complete all as specified and directed by Engineer-in-charge. Note: Excavation and Earth work, PCC in foundation and copping shall be measured and paid separately.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for errection of HT/LT poles laying of HT/LT UG cables and provn of stay assembly complete
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type soil complete all as specified.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and entire satisfaction of Engnr-in-Charge complete all as specified and directed
Sand dry clean as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as speficied.
M&L for Un-reinforced precast concreate cable cover of size 300x180x40 mm for protection cable, laid transversally along the length of cable complete all as specfied and directed.
Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all as directed.
Supply, Laying, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross sectional area 185 sqmm 3 core conforming to latest IS and ISI marked complete all as specified and directed by Engrr-in-Charge,
Supply, Laying, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross sectional area 95 sqmm 3 core conforming to latest IS and ISI marked complete all as specified and directed by Engrr-in-Charge,
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core, complete all as specified and directed by Engineer-in-Charge
M&L for route indicator including excavation and other civil work made out of PCC Solid block type B1 1:2:4 using 20 mm graded aggergrate set in cement Mortar 1:4 of size 30x45 cm above ground level and 25 cm below ground level for HT/LT cable mentioning the size of Cable with paint on PCC block as per direction by Engr-in - charge complete all as specified and directed.
Supply and install HT bus bar chamber 11 KV, factory made, weather and vermin proof having size 90x90x60 cm made out of 3mm thick MS sheet with 200 Amp rated bus bar and with 11 KV pedestal type HT insulators 6 No with angle iron frame of size 75x75x6mm duly painted with two coats of enameled paint and necessary PCC work for foundation complete all as specified and directed by Engineer in charge.
S&F in replacement HT 11 KV volts grade overhead Arial Bunch Conductor having phase conductor of stranded compacted circular aluminium, Conductor screen of extruded semi conducting compound, XLPE insulated, Insulation screen of semi conducting compound, overall Metalic screen of copper type, extruded PVC type ST2 sheathed, twisted armoured bare aluminium alloy messanger conductor generally as per IS-7098/P-2 on existing poles 3-core X 95 sq mm + 1 x 70 sq mm
Steel tubing galvanized(Light grade)100mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete all as specified and directed..
Steel tubing galvanized(Light grade)80mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete all as specfied and directed. Note: The work under subject BoQ (item No. 1.00 to 63.00 ) are meant for maint of External Electric Supply in Nagrota Mil Stn ( Including Katra, Sanjhi Chat, Charli Hill ). The work shall be executed on ground on required basis. Contractor responsibility is to liase with the department concerned for HT supply shut down required to carry out the work & also ensure the safety of labour employed by giving them safety equipments like helmet, gloves, safety belt , discharge rod etc and nothing extra shall be permisissible in this account.
MAMTA ENTERPRISES (BID ID -3392700)
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3391666)
Sarbat Construction Co (BID ID -3392854)
M/S S K Electricals Regd (BID ID -3391341)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .