Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹51.9 L+₹5.4 L (11.6%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹65.1 L+₹18.6 L (40.1%)Rejected-Finance 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹68.6 L+₹22.1 L (47.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹90 L+₹43.5 L (93.7%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Mar 2022, 6:00 pmClosed
CWE Jaipur
HQ CWE Jaipur, Kalyan Marg, Jaipur
PROVN OF 25 BEDDED COVID ICU (02 NOS STRETCHER LIFTS) IN MH UNDER ZONE-II AREA AT JAIPUR MIL STN
2022_MES_509789_1
CWE/JPR/82144/E8
Open Tender
Miscellaneous Works
Item Rate
1945 days
GE Jaipur
Enlisted with MES in Class D and above and category c (ii) or a(1) or b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Jaipur
₹70,000
Yes
31 Mar 2022
22 Feb 2022
17 Mar 2022
22 Feb 2022
14 Mar 2022
26 Feb 2022
Amount
STRETCHER LIFT:- Supply, erection, installation, testing and commissioning of Stretcher lifting Mechanism for 1360 Kg Load, speed 0.50 m/sec etc. complete all as specified below Make:- KONE/ SCHINDLER/ OTIS/ JOHNSON/ MITSUBISHI(ETA)/ THYSSEN KRUPP
Tech specification of stretcher lifting mechanism:- (i) Type - Electrically operated Passenger Cum stretcher lift for hospital (ii) Capacity- 1360 Capacity (20 Passenger) (iii) Number of landing - 02 (iv) Landing Levels - 0.0 m , 4.0 m (v) Car speed – 1.0 mps (vi) Machine Type- Traction Gear less (vii) Car Size - (Inside) - 1300x 2400 x 2300 mm height (viii) Door size –WxD-1100x2100mm height (viii) Door Type - Automatic, two panels, centre opening, power operate and horizontally sliding type, made up of ss- 304, 1 mm thick (ix) Car Panel - SS Panel (landing and Car Door) Stainless steel 304,1.0 mm thick
DESIGN CONSTRUCTION & PERFORMANCE REQUIREMENT:- (i) The elevator shall be designed to lift the payload in addition to weight of the car itself and other accessories. (ii) The number of wire ropes and size of wire rope shall be so chosen that highest factor of safety is achieved as per standard IS 2365: 1977 (iii) The car shall be enclosed on all sides by means of car body and door. The sides of the car shall be lined with heavy stainless steel gauge sheet panels with latest designs properly braced and reinforced. (iv) Car roof shall be covered with sheet metal to prevent dripping of lubricants from ropes-sheave bearings. The top flooring shall be of steel. (v) The elevator shall be equipped with automatic self- leveling devices to bring the car to the floor landings (vi) The terminal buffers shall be furnished for stopping the car Driving System (i) Driving Machine - 3 Ph 10 HP (ii) Controller (iii) Frequency Invertors (iv) Door Operator (v) Infrared light Curtain (vi) Traveling Cable (vii) Rope
Note:- 1. All necessary civil work like RCC framed structure foundation, Excavation, Earth work, RCC Foundation, PCC work etc shall be measured and paid under respective items. 2. The contractor shall be make arrangement of interconnection of existing building and quoted rate is deemed to be included this provision.
CIVIL WORK (RCC FRAMED STRUCTURE)
Excavating over areas, not exceeding 1.5m deep and getting out in any type of soil by mechanical means etc complete all as specified and directed.
Excavating over areas, exceeding 1.5m and not exceeding 3.0.m deep and getting out in any type of soil by mechanical means etc complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
M&L for Brick work sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) etc complete all as specified and directed.
M&L cement concrete in foundations, filling and mass concrete type D-2, (1:4:8) using 40 mm graded aggregate. etc complete all as specified and directed.
M&L for Hardcore of broken stone or boulders of gauge not exceeding 63 mm deposited, spread, levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed.
M&L for 100 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in floor finish etc complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cracking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. etc complete all as specified & directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified & directed.
Formwork to sides and soffits Rough finished surfaces of concrete of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, column etc. also splays between floors and beams, etc complete all as specified & directed.
Formwork to soffits of suspended slabs Rough finished surfaces of concrete such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc complete all as specified & directed.
Formwork to sides of Rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified & directed.
M&L RCC M-25 (Design mix) (20mm graded aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified & directed.
M&L RCC M-25 (Design mix) (20mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified & directed.
M&L RCC M-25 (Design mix) (20mm graded aggregates) as Columns, pillars, piers, posts and struts etc complete all as specified & directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of concrete surfaces of roof surfaces mixed with WPC @ 3% by weight of cement finished even & smooth including taking down existing water proofing treatment etc complete all as specified & directed. Make:- ‘Plastocrete Plus of sika/ pidiproof LW of pidilite or equivalent in for water proofing compound
M&L for rendering 10 mm thick in CM (1:3) on ceiling/ceiling patches finished even and fair without using extra cement etc complete all as specified and directed.
M&L for rendering 15 mm thick on brick masonry in CM(1:6) finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of exterior emulsion paint mechanical means over a coat of primer on wall etc. complete all as per specified and directed.
M&L for preparing new plastered surfaces and applying three coats of white wash on ceiling etc. complete all as per specified and directed.
M&L for preparation newly plastered surfaces and applying wall care putty to achieve uniform thickness and (priming seal-o-prime ) and two coats of interior acrylic emulsion paint using hand roller on internal wall surface, complete all as specified and as directed.
comprehensive annual maintenance
Fully comprehensive annual maintenance of 2 Lifts installed under item no 1 above
NOTES FOR ITEM NOS 3.01:- (a)The scope of works includes the following and rate quoted shall be deemed to be included in this provision.. (b) Contractor shall be submit the MOU between the contractor and OEM or authorized service dealer of OEM and same shall be submitted in original and uploaded along with tender documents (c) Periodic maintenance as per OEM (2 Major visits + 4 Inspections per year) shall be done during contract period (Phase-II). (d) Rate quoted shall be included of all the spares required to be provided/replaced for maintenance. (e) Contractor shall be available on call from (9 am to 9 pm) and shall be attended and required spares shall be replaced free of cost. (f) Repairs or replacement of all parts which have become unusual through wear & tear (e.g VF drive unit, Automatic rescue device, car and landing door shoe liners, contacts, switches, door operator motor, drive belts, coupler unit, door safety sensors, emergency alarm unit, door drive unit, car and landing call registration buttons and all electronic PCBs Gearbox, motor, over speed governor, door drive, safety gear, suspension ropes, traction sheaves, drive wheels and travelling cables) also be provided and deemed to be included in the quoted rate.
(g) Oil change at regular intervals in the Drive units and proper disposal of the old oil. (h) Replacement of damaged or fault emergency lamps in the car during the regular inspection/ preventive maintenance.
Shri Balaji Construction
Omega Elevators
M/S Sheeba Enterprises
SHREE BHAGWATI ENTERPRISES
BAKSHI BUILDERS PVT LTD
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .