Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC 6 SAI KRUPA SONAWANE PARK BEHIND TILAK NAGAR BUS STOP OZAR MIG NASHIK 422206 | NASHIK | NASHIK | MAHARASHTRA | 422206 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.8 L+₹56,345 (3.48%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹17.1 L+₹92,063 (5.68%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹15.0 L
EMD Value
₹29,800
Closing Date
17 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
Repair to drains path plinth protection hardstanding etc in domestic and technical area at AF station Ojhar
2020_MES_339294_3
8657/E8
Open Tender
Civil Works
Item Rate
240 days
ojhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹29,800
Yes
20 Jul 2020
3 Jun 2020
19 Jun 2020
4 Jun 2020
17 Jun 2020
5 Jun 2020
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil (Including brickwork and PCC in drain below Ground level)
Excavating over areas, n exc 1.5 m deep and getting out hard/ dense soil
M & L for plain cement concrete 1.3:6 type C2 (using 40m graded stone aggregate) in foundations, filling and mass concrete etc. as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete.
M&L for Brickwork with fly ash bricks (Minimum comprehensive strength 35kg per cm2), straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed by Engineer-In-Charge
All as per item No 05 above but except brick
M&L Brickwork with fly ash bricks (Minimum comprehensive strength 35 kg/cm2), straight or curved on plan exc 6m mean radius, built in CM 1 : 4 all as specified and directed by Engr-in-Charge
M&L Brickwork with fly ash bricks (Minimum comprehensive strength 35 kg/cm2), straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete
M&LBrickwork with fly ash bricks(Minimum comprehensive strength 35 kg/cm2) in brickon- edge walls (less than ½ brick thick),built in CM 1:4 complete
M&L for PCC type B0 in 1:2:4 ( using 12.5mm graded aggregate) as in coping, bed block and surface channel of drain all as specified and directed by Engr in Charge
M&L Flush pointing to brick walls in CM 1:4 complete all as specified
M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge
M&L for Extra for forming fair finished drain or channel exc 45cm and upto 65 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc all as specified and directed by Engr in charge
Extra for forming fair finished drain or channel upto 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.
Removing excavated material beyond MoD land and depositing at contractor own arrangement
M&L for reinforced concrete pipes 450mm dia, class NP2, laid and jointed complete with collars
M&L for reinforced concrete pipes 600mm dia, class NP2, laid and jointed complete with collars
M&L for cement concrete bed PCC 1:4:8 type D2 to drain pipes 450mm dia including packing under and completely surrounding pipes with concrete after they are laid and tested; in all as specified
M&L for cement concrete bed PCC 1:4:8 type D2 to drain pipes 450mm dia including packing under and completely surrounding pipes with concrete after they are laid and tested; in all specified.
Supply and fixing in repair concertina coil fencing with punched tape concertina coil 900 mm dia 7 to 10m openable length having 50 Now round per 6 mtr length, spring core wire (2.5mm thick) of high tensile strength of 165Kg/Sqmm with tape (0.52mm thick) and weight 43.47gm per meter and fixing the same with existing/New Y shape angle iron placed 3m apart with all fixing arrangement GI wire all as specified
Supply and fixing in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (eachline wire to be measured)
Dismantling wrought iron or mild steel work of any description not otherwise provided all as specified and directed.
M&Lmild steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
SHREE SAMARTH SERVICES
Chandan Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .