Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-Finance | L1 | Accepted-Finance Accept | |
| 2 | L2₹38.1 L+₹2.7 L (7.50%)Accepted-Finance | L2 | Accepted-Finance Accept | |
| 3 | L3₹41.9 L+₹6.5 L (18.2%)Accepted-Finance SH 132 H NARAYANPUR SHIVPUR VARANASI UTTAR PRADESH 221003 | VARANASI | UTTAR PRADESH | 221003 | L3 | Accepted-Finance Accept |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
9 Dec 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER URBAN
SUPERINTENDING ENGINEER URBAN ELECTRICITY DISTRIBUTION CIRCLE I 64 CHANDRIKA NAGAR COLONY VARANASI
For Construction of New Bay, 02 Nos Isolator at 33/11 KV Nagar Nigam S/S , 02 Nos Isolator at Vidhyapith and 33 KV U/G Line for Giving Supply to the Building of International and Convention Centre, Sigra, Varanasi Under Deposited Scheme.
2020_PVVNV_534604_1
81/UEDC-I(V)/2020-21
Open Tender
Electrical Works
Lump-sum
90 days
EE, UECD-I
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,614
EXECUTIVE ENGINEER, UECD-I, VARANASI
₹36,000
Yes
11 Dec 2020
2 Dec 2020
9 Dec 2020
2 Dec 2020
9 Dec 2020
2 Dec 2020
90 days
Amount
For Construction of New Bay, 02 Nos Isolator at 33/11 KV Nagar Nigam S/S , 02 Nos Isolator at Vidhyapith & 33 Ky U/G Line for Giving Supply to the Building of International and Convention Centre, Sigra, Varanasi Under Deposite Scheme.
Shifting loading and safe Carriage of STP from central store Rajatalab to site including loading & unloading
Shifting loading and safe Carriage of 33 Kv Cable from central store Rajatalab to site including loading & unloadinq
Shifting loading and safe Carriage of VCB,Isolater,C.T,& Control Pannel PPMC, CT/PT unit etc includinq loadinq Unloadinq.
Erection of Pole and structure on 11 mtr. ST Pole including all works of excavation of pit, pole erection, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth , proper ramming, making of plinth & fitting of all accessories
Making of RCC cable trench including its cover and edges of tench and cover will be fitted with angle of appropriate size so that it cover fits with out any gap.
Making of 33kV XLPE Heat shrinkable outdoor jointing kit after duly plumbing and taping of cable , providing, fixing and crimming of proper size good quality lugs and their connection with HT line
Plinth and foundation for 33 KV VCB Pannel and make connection with VCB, CT & PT
Erection and commissioning of 33KV CT,Isolator,VCB as per respo drawinq no RES -39
Erection and commissioning of 33KV RMU and its all connection like RTU etc
Installation of 33kv double T/F control pannel with all connection
Connection of both 33kv sources present at Nagar Nigam substation to isolator and shifting of existing 33kv cable to isolator to be installed and then connection of 33kv cable to existing transformer Bus and shifting of other 33kv cable as required by engineer in charge
Suppy & Fixing of Bracing clamp for clamping of g.i pipe with MS N&B at different places for existing section double pole.
Equipment needed for maintenance and testing of system as per specification which are to be given by contractor to site engineer Metravi DIT-916 digital Insuation tester 1 no,Waco digital earth resistance tester 1 nos ,Fluke 115 true RMS digital multimeter 1 Nos , Fluke 317, 600 Amp AC/DC digital true RMS clamp meter 1 Nos, wrench 1 set whole, hammer 1 no, 2 no Saw, 2 no. Axe, 2 no. long rope, 2 no. earth chain, 1 no. ladder,safety belt 2 no., pulley 1 no.
A 2.5 mtr long 40mm dia Galvanised pipe(Earth electrode) shall be driven to its full length so that top is at least 500mm below and welded to main eath strip of size 35*6 mm G.S. The strip of ground mat shall be installed at 500mm . Earthing of outdoor equipment will be done with branch strip of 25*6 mm GS both sides as per respo drawing RES 36
Labour cost for errection and commissioning of PPMC, CT/PT and metering unit and 2 no of GI chemical gel electrode earthing for CT/PT unit and PPMC and connecting the equipment to 25*6 mm GS flat .
Laying of cable in switchyard in cable trench 0.45 m wide, 1.2 m depth and laying of 3*300 sqmm XLPE cable by providing 150 mm local sand for cushion beneath and 150 mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick on both side of cable by laying brick vertically and stone would be laid horizontally on top of vertically laid bricks along the cable (minimum 17 nos of bricks per mtr length are to be laid top and outer side along the cable).
Laying of HDPE pipe in cable trench 0.45 m wide, 1.2 m depth and laying of 3*120 sqmm XLPE cable through HDPE pipe by providing 150 mm local sand for cushion beneath and 150 mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick on both side of cable by laying brick vertically and stone would be laid horizontally on top of vertically laid bricks along the cable (minimum 17 nos of bricks per mtr length are to be laid top and outer side along the cable). Making of cable route daigram on A1 sheets (5 no copy) indicating the location with distance from Substation to Convention center.
Cleaning of switchyard at all respect before starting the work and leveling it after the completion of work
Laying of different size of (2x2.5) sqmm / (4x2.5) sqmm Armoured control cables i.e; from 33 KV CT's to CT's Junction Box, CT 33 KV, VCB Control Panel Junction Box to 33 KV Control Panel and Control Panel to 33 KV VCB outdoor operating mechanism panel etc in the cable trench including making proper connection and indication board as per required for installed equipment.
Supply, Stacking and spreading of 10 Graded stone aggregrate 40mm nominal size after spreading of stone dust (13x15x0.1)
Supply, Stacking and spreading of stone dust after levelinq the qround (13x15x0.1)
Lightening arrangement for outdoor switchyard with four no LED light 100W each (philips/ eveready brand) with existing pole including wiring arrangement with havells or equivalent standard wire of 1 sqmm in PVC cable and fixing it to substation wall and installation of 16 Amp MCB including board for switch on and off. Arrangement of lighting in control room where pannel is to be fixed by three no of tubelight and their connection through pvc cable.
Painting of all structures at Substation with rubbing of old rust, 1st coat with red oxide primer & two coats with good quality of aluminium paints & 0.5 M on top with post red oxide paint including cost of all materials and paint.
Control room civil work for installation of Panels and Battery charger
Fabrication and errection of cable support made of two pieces of MS Angle (50x50x6)/ (65x65x6) mm, 2.75 metre long joined to each other by means of 5 nos MS flat (50x6) mm pieces of size 150 mm long each by welding at equal intervals and grouting in a block of size (300x300x700) mm in CC 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paintwork includes providing of three nos MS clamps made of (50x6) mm MS flat for holding the cable including nuts and bolts
Shifting of existing fan of existing power transformer and its connection to location predecided
De-Centralised Item
33 KV 3x120sq.mm O/D cable Box Raychem make only
33 KV 3x300sq.mm O/D cable Box Raychem make only
33 KV 3x120sq.mm I/D cable Box Raychem make only
140 mm O/D PN-4 PE- 80 Grade UV stabilized HDPE pipe as per IS: 4984 of 6 Meter
MS N&B of size with washer
Cable root markar
G I Pipe
M/S KAMALAWATI DEVI CONSTRUCTION
M/S SERVICE AND SOLUTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .