Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.5 L+₹1.7 L (12.6%)Rejected-Finance 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹15.7 L+₹1.9 L (13.6%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹16.7 L+₹2.9 L (21.0%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹18.2 L+₹4.4 L (31.6%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹18.1 L
EMD Value
₹36,500
Closing Date
29 Jan 2020, 6:00 pmClosed
GE ALWAR
GE ALWAR
REPAIR / MAINTENANCE OF EXTERNAL ELECTRIFICATION SYSTEM AND LT DISTRIBUTION SYSTEM INCLUDING STREET LIGHTS REPAIRS IN CITY AREA ALWAR
2020_MES_311179_1
8909/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹36,500
Yes
14 May 2020
2 Jan 2020
30 Jan 2020
2 Jan 2020
29 Jan 2020
17 Jan 2020
2 Jan 2020 - 16 Jan 2020
Amount
Repair of street light fitting fixed on pole without taking down the fitting from the pole of any type, capacity & make by replacement of spare parts & making the fitting functional all as specified and directed by Engineer-in-Charge. Note : Spare parts/accessories required to be replace shall be measured and paid seperately as "Supply only" under the relevent items.
Disconnecting and taking down the street light fitting from the pole and repair of street light fitting of any type, capacity & make by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. Note : Spare parts/accessories required to be replace shall be measured and paid seperately as "Supply only" under the relevent items.
Disconnecting and taking down High Mast light from the steel tower and repair of High Mast fitting of any type, capacity & make by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. Note : Spare parts/accessories required to be replace shall be measured and paid seperately as "Supply only" under the relevent items.
Supply only following spare parts/accessories required for repair of street light under appropriate item here-in-before :-
Open Construction heavy duty copper ballast for HPSV/metal halide luminaries of capacity 70 W. Make : CG/Surya/Philips
Open Construction heavy duty copper ballast for HPSV/metal halide luminaries of capacity 150 W. Make : CG/Surya/Philips
Open Construction heavy duty copper ballast for HPSV/metal halide luminaries of capacity 250 W. Make : CG/Surya/Philips
Open Construction heavy duty copper ballast for HPSV/metal halide luminaries of capacity 400 W. Make : CG/Surya/Philips
Metal halide lamp of 250 Watt. Make : CG/Surya/Philips
Metal halide lamp of 400 Watt. Make : CG/Surya/Philips
HPSV lamp of 70 Watt. Make : CG/Surya/Philips
HPSV lamp of 150 Watt. Make : CG/Surya/Philips
Ignitors suitable for HPSV lamp of 70/150/250 Watt. Make : CG/Surya/Philips
Ignitors suitable for HPSV lamp of 400 Watt. Make : CG/Surya/Philips
Holder for HPSV lamp of 70/150 Watt. Make : CG/Surya/Philips
Surge protection device (SPD) for LED street light fitting 60/90 Watt. Make : CG/Surya/Philips
BIS registered potted driver with 'R' number for LED street light fitting 60/90 Watt. Make : CG/Surya/Philips
Chip for LED street light fitting 60/90 Watt. Make : CG/Surya/Philips
Driver chip for LED street light fitting 20 Watt. Make : CG/Surya/Philips
Supply and fixing weather proof PVC insulated & sheathed twin core stranded aluminium conductor 2.5 Sqmm cable 1100 Volts grade (ISI marked) from over head conductor to street light fitting, including taking down old existing unserviceable cable all as directed. Make : Havells/ Finolex/Polycab.
Supply and fixing weather proof PVC insulated & sheathed twin core stranded aluminium conductor 2.5 Sqmm cable 1100 Volts grade (ISI marked) from street light fitting to junction box including taking down old existing unserviceable cable all as directed. Make : Havells/ Finolex/Polycab.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to PCC Pole with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts & bolts, matching with section of PCC Pole, including taking down old existing unserviceable mounting bracket with clamps etc, complete, all as directed.
Supply and fixing factory made street light pole junction box of minimum size 250mm x 300mm x 150 mm depth, made out of 2mm thick CRCA MS sheet, totally enclosed, shock proof, IP-65 protection, dust proof, water proof, front openable, weather proof, powder coated finish on outside & inside surfaces (of approved shade), with aluminium bus bars (2 Nos) of rating 100 Amp mounting on insulators with & including MCB SPN 6 Amp 240 Volts fixed on sheet metal enclosure outgoing for street light, junction box fixed on pole with suitable MS clamp of flat iron 25x3mm, nut, bolts, washers, complete all as specified & as directed including taking down old existing unserviceable junction box any type & any size.
S & F 12 Watt Garden light / gate light aluminium housing, clear acrylic diffuser, cast alumonium pole cap complete accessories suitable for OD of dia 60mm pipe including taking down old unserviceable light fitting complete all as specified and directed. Make :- Havells/Syska / Crompton Greaves as approved by GE
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation of poles/struts, stays, laying of cables, pipes etc and getting out in soft/loose soil complete all as specified.
All as per serial item No. 10.00 here-in-before but depth exc 1.5m and not exc 3m.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection including taking down old unserviceable bricks complete all as specified & directed.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps. Note :- Excavation & earthwork shall be measured & paid for separately.
Boring of holes under road, pavement, hard standing by trench less technology using ultra sound technique & necessary machine including suitable HDPE pipe of 80mm outer dia for 0.4 mpa working pressure complete all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including taking down old unserviceable cable complete all as specified. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No 20.00 here-in-before but cross sectional area 16 Sqmm 2 core.
All as per serial item No 20.00 here-in-before but cross sectional area 25 Sqmm 3.5 core.
All as per serial item No 20.00 here-in-before but cross sectional area 50 Sqmm 3.5 core.
All as per serial item No 20.00 here-in-before but cross sectional area 95 Sqmm 3.5 core.
All as per serial item No 20.00 here-in-before but cross sectional area 120 Sqmm 3.5 core.
All as per serial item No 20.00 here-in-before but cross sectional area 185 Sqmm 3.5 core.
Dismantling of existing unserviceable street light panel with accessories and Supply, install, testing and commissioning factory made street light panel, out door type, made out of 14 SWG sheet size 90x90x45cm with 4 Nos alluminium bus bar of rating 100 Amps mounting on insulators etc mounted on MS angle 50x50x6mm including painting and front openable backlite sheet 6mm thick suitable for mounting of MCCBs with double door and locking arrangement and PCC foundation 45 cm above ground level as directed complete with following accessories and taking down old unserviceable Panel complete all as specified and directed. (a) MCCB, TPN, 100 Amp, 16 KA, 415 volts – 01 No. (b) Aluminium bus bar TPN 100 Amp rating - 01 Set (c) Digital timer switch 110-240 VAC, 50-60 Hz tolerance - 20% to 10% contact 16 A (NO) & 5 A (NC) @240 VAC/24 VDC model digital crono times setting by date and position coordinates, Cat part No 67DDTO including 32A MNX32 contactor - 02 Nos suitable for use on a circuit capable of delivering not more than 5000 RMS sy (d) Electronic contactor 3 pole suitable for 70 Amps 415 volts AC make : L&T/ABB/SIEMENS/C&S - 01 No (e) Indicating lamp R,Y,B Set of three - 01 No (Contd....)
(Contd....) Notes : (i) LT panel shall be fixed on platform with PCC (1:4:8), type D-2 using 40mm graded crushed stone aggregate 15cm thick in foundation, brick masonry in CM (1:6) and 15mm thick rendering in CM (1:6) on exposed surfaces and 150mm thick PCC padding in PCC 1:3:6, type C-1 on top and grouting bolts etc for panel. The platform shall be 60cm height from the nearest road level/floor level, complete, all as directed by Engineer-in-Charge. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. (iii) Drawing of LT Panel shall be got approved well in advance from GE before fabrication of LT Panel. (iv) The quoted rate shall deemed to include supply & provision of 65mm lock with 2 keys. Make of Lock :- Godrej / Harrison / Link. (v) Cost of suitable platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply and fixing in repairs following items for existing Street light panel complete all as specified and directed.
MCB, TPN, 63 Amps, 415 volts. Make :- Legrand Cat Part No 4086 83 or equivalent of Havells / ABB as approved by GE
MCB, SP, 32 Amps, 230 Volts, AC. Make :- Legrand Cat Part No 4085 95 or equivalent of Havells / ABB as approved by GE
MCB, SPN, 32 to 63 Amps, 230 volts, AC. Make :- Legrand Cat Part No 4086 17 or equivalent of Havells / ABB as approved by GE
Indicating lamp R Y B Set of three
Electronic contactor 3 pole suitable for 32 Amps, 415 volts AC, Make - L&T/Siemens/C&S
Electronic contactor 3 pole suitable for 70 Amps, 415 volts AC, Make - L&T/Siemens/C&S
Electronic timer ET 100, 110 / 240 volts, 50 Hz Make - L&T/Siemens/C&S
Aluminium bus bar 25mm x 5mm.
Supply and fixing in repairs MCCB 4 pole, 415 volts - 50 Hz, magnetic fix type of capacity 63 Amps, 16 KA complete all as specified and directed. Make :- Legrand Cat Part No 4200 13 or equivalent of Havells / ABB as approved by GE
Supply and fixing in repairs MCCB 4 pole, 415 volts - 50 Hz, magnetic fix type of capacity 100 Amps, 16 KA complete all as specified and directed. Make :- Legrand Cat Part No 4200 15 or equivalent of Havells / ABB as approved by GE
S & F globe shaped for existing garden light in frosted finish made up of Polycarbonate including taking down old unserviceable glob complete all as specified and directed.
S & F globe shaped for existing garden light in frosted finish made up of Polycarbonate suitable for 27 Watt retrofit LED including taking down old unserviceable glob complete all as specified and directed. Make :- Havells Cat Part No LHDC13126099 or equivalent of Syska / Crompton Greaves as approved by GE
S & F LED New adore 9 watt ball lamp for garden light including taking down old unserviceable light fitting complete all as specified and directed. Make :- Havells Cat Part No LHLDERHEMD8X009 or equivalent of Syska / Crompton Greaves as approved by GE
S&F pre-stressed concrete pole 09 metre long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and marking pole number, complete, including excavating and taking out existing damaged pole & making good hole to receive new pole all as specified & as directed. Note :- PCC in foundation & coping shall be measured and paid for separately.
Supply, Installation, commissioning and testing of JETA NEO type LED based flood light with fitting of 50 watts rating energy saving IP-65 flood light luminarire with high power COB LED as light source complete with all fittings and prewired complete including taking down old unserviceable flood light all as specified and directed. Make :- Havells Cat Part No LHEPBFUEIN6W050 or equivalent of Syska / Crompton Greaves as approved by GE
M&L for PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed. Note :- Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified. Note :- Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
Dismantling unserviceable steel members and M & L for mild steel cross arm bracing clamps angle iron channel etc fabricated from structural steel section including with nut, bolts, GI washer welding, bending, clod or hot, drilling holes for bolts, in any shape or size as directed and inclusive of one coat primer and two coats of synthetic enamel paint complete all as specified and directed.
M & L painting to cross arm, clamps, channels etc with one coat of aluminium paint including cleaning of existing surface with wire wire brush on existing PCC poles complete all as specified and directed.
M&L painting of existing steel tubular pole surface complete with one coat of aluminium paint including cleaning of existing surface with wire brush and painting of existing steel poles upto 150cm, 30 cm with two coat of colour code yellow and black as per colour code of LT pole and marking of pole No complete all as specified and directed.
M&L painting of existing PCC pole upto 150 cm, 30 cm with two coat of colour code paint yellow and black as per colour code of LT Pole and marking of pole No complete all as specified and directed.
Supply, installing and testing out door wheather proof bus bar chamber of size 60 cm x 30 cm x 25 cm made out of 3.15mm thick MS sheet having one side openable hinged door shutter with locking arrangement/Provn of two No 60 Cm long 40x40x6mm angle iron legs welded and 4 Nos aluminium bus bar of 200 Amp rating & incoming MCCB 100 Amps adjustable thermal and magnetic release type complete errected on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland, lugs/thimbles complete including taking down old unserviceable bus bar chamber all as specified and directed.
S&F pin type porcelain vitreous brown/white insulator with approved make including one MS spindle two GI washer and GI nut of size 100 mm height and 65 mm dia 1100 volts grade including taking down old unserviceable pin type insulator complete all as specified and directed.
S&F shackle type porcelain vitreous brown/white insulator with approved make including MS strip washer, insulated bolts, washers, nuts of size 75 mm height and 90 mm dia 1100 volts grade including taking down old unserviceable shackle complete all as specified and directed.
M&L for aluminium conductor steel reinforced (ACSR) of any size including aluminum binding wire from overhead lines on LT poles including dismantling & taking down old unserviceable all as directed. Note :- (i) Weight of old conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (ii) Weight of the old conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F Garden light BAMBOO type fitting new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED 9 W as light source including LED lamp and necessary PCC work/FI nuts, bolts for mounting the fitting complete including taking down of old U/S garden light. Make : Havells Cat Part No LHEVBDP71N6K008 or equivalent of Syska/Crompton Greaves as approved by GE.
Disconnecting of existing LT cable in LT panel and S&F opening cable loop in existing LT cable in LT Panel for suitable size with thimbles/lugs including internal wiring with 2.5 Sqmm copper cable & painting in LT panel with white/smoke grey colour enamel paint & including door repair, hinges welding complete all as specified and directed.
S&F in repairs MCCB, 4 Pole, 400 Amps rating, rupturing capacity 36 KA, 415 Volt grade, AC, 50 Hz, with adjustble Thermal - Magnetic release and making connection complete all as specified and directed. Make :- Legrand Cat Part No 4220 02 or equivalent of Havells / ABB as approved by GE
S&F in repairs MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 KA, 415 Volt grade, AC, 50 Hz, with adjustble Thermal - Magnetic release and making connection complete all as specified and directed. Make :- Legrand Cat Part No 4202 39 or equivalent of Havells / ABB as approved by GE
S&F in repairs MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 KA, 415 Volt grade, AC, 50 Hz, with adjustble Thermal - Magnetic release and making connection complete all as specified and directed. Make :- Legrand Cat Part No 4200 87 or equivalent of Havells / ABB as approved by GE
Disconnecting of electric connection of existing any capacity transformer and M&L two coats of synthetic enamel paint of approved tint colour after cleaning of all external surfaces of any capacity transformer & connect to electric connection after repair work complete all as specified and directed.
M&L for earthing with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 32mm x 6mm as earth lead, welding at top of electrode and other end of strip connected to test point with two Nos nuts bolts, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level with and including Cont....
Cont... 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking done old unserviceable earthing all as specified & as directed. Note : (i) Item includes cost of 7.5m earth lead strip. (ii) Earthing shall be provided as per IS-3043 and relevant clauses of MES SSR Part-I. (iii) Earthing shall be done in a manner that the inner edge of earth pit is at least 2 metre from the building foundation (extreme outside end) and the minimum distance between two earth electrodes shall be regulated as per IS-3043.
Surface dressing/cleaning surrounding area of two pole/four pole structure, pump house area, fencing area etc including removing of tree branches, small tree plant, bushes etc complete all as specified and directed.
M&L stay assembly complete with accessories as shown in electrical plate No 1 of SSR Part-I for Steel structures/GI poles, using stay rod of 16 mm dia & 180 cm long including GI stay wire of 7/4.00 mm of suitable length as required, galvanized steel stay bow 400 x 14mm, Including loop insulator of size 90x140mm clearance hole 25.5mm & with steel plate of size 300 x 300 x 6mm thick & 2 Nos thimbles including taking outold unserviceable stay assembly complete all as specified & as directed. Note:- All excavation & earth work and foundation concrete shall be measured and paid for separately under relevant items of this schedule.
Cutting/trimming of tree branches around the LT/HT overhead line 3 metre clearance around from the external conductors & removal the same from site and depositing at places within the Cantt as directed. Note : Length of span shall be 30 to 40 metre approximate.
Restraining/tightening of existing LT over head ACSR conductor of any size upto permissible sag in between existing span including GI earth wire, clamps, cradles etc. including new 2mm dia aluminum binding wire complete all as specified. Note :- The length of each conductor shall be measured & paid for. The rate quoted shall be for one conductor.
M&L for repair to APFC panel of any size and capacity by replacement of U/S internal wiring with new PVC insulated stranded copper conductor FRLS cable of existing sizes but not less than 6 Sqmm including replacement of U/S fixtures/items/accessories such as capacitor, contactor, MCB, MCCB, bus bar, CTs relay, voltmeter, Amp meter, indicating lampetc and setting of relay to achive power factor 0.99 and indicating lamp including taking down of U/S parts complete all as specified and directed.
Supply only following fixtures/ accessories required for repair of APFC panels under serial item No. 57.00 here-in-before :-
Microprocessor based Intelligent Power Factor Controller (IPFC) Relay suitable for Manual/automatic operation with 6 relay out put and one alarm relay, supply voltage 230 volts and inter phase menu driven display of various parameters (Cap Banks Status, PF, KW, KVAr, KVA, Voltage, Current, Frequency, Temperature & Target PF) and storage of various values and test run options and accessories for grid current measuring module for current measurement of inherent current of capacitor bank and remote indicator. Make : Model No BR 6000-R6 of EPCOS or Model No RPM - 8 of L&T or Model No PFC - 11000I of Havells.
Contactor 3 Pole, 63 Amps 415 Volts (Type MNX). Make : L&T/ABB/SIEMENS/Havells
Contactor 3 Pole 40 Amps 415 Volts (Type MNX). Make : L&T/ABB/SIEMENS/Havells
Contactor 3 Pole 25 Amps 415 Volts (Type MNX). Make : L&T/ABB/SIEMENS/Havells
Contactor 3 Pole 18 Amps 415 Volts (Type MNX). Make : L&T/ABB/SIEMENS/Havells
Power factor correction capacitor of 2 KVAR, Three Phase, 415 Volt, 50 Hz, heavy duty, cylindrical type, gas filled. Make : L&T/EPCOS/SIEMENS/Havells
Power factor correction capacitor of 3 KVAR, Three Phase, 415 Volt, 50 Hz, heavy duty, cylindrical type, gas filled. Make : L&T/EPCOS/SIEMENS/Havells
Power factor correction capacitor of 5 KVAR, Three Phase, 415 Volt, 50 Hz, heavy duty, cylindrical type, gas filled. Make : L&T/EPCOS/SIEMENS/Havells
Power factor correction capacitor of 10 KVAR, Three Phase, 415 Volt, 50 Hz, heavy duty, cylindrical type, gas filled. Make : L&T/EPCOS/SIEMENS/Havells
CTs of ratio 5/100 A, coil type FOR APFC control panel.
Copper Bus bar strips of size 30mm x 3mm thick
S&F topup distilled water in solar tubular battery 75 AH 12 V for solar security light complete all as specified and directed.
Repairing of solar security light including cleaning of solar panels and refixing of battery terminal, replacement of U/S lamp, checking connection of light fitting complete all as specified and directed.
Supplying, installation, commisioning and testing of solar tubular battery 75 Ah 12 V for solar security light including taking down old unserviceable battery complete all as specified and directed.
Removing old unserviceable cable any size and depositing to AGE E/M store yard including transportation and making good surface, wall, floor etc complete all as specified and directed.
Supply, Installation, commissioning and testing of High Intensity type LED based street light of 100 ± 2 watts rating enclosed in high grade aluminum pressure die-cast housing with heat resistant toughened flat glass suitably gasketed all including high power LEDs with secondary lence optics, surge protection device (SPD), inbuilt micro controller power supply, BIS registered plotted driver with 'R' Number, Ingress protection IP-65/66, operating Voltage range 120 V-270 V, 50 HZ, AC heat management compliance & system efficiency of fitting should not less than 100 lumen/Watt. Lumens Flux 10000 Lumen, easily adjustable for different mounting pipes, seprate electronic driver cabin fully compliance to IS-10322, dust and water proof cabinet, Effeciency of driver electronic not less than 90%, power factor of complete fitting not less than 0.95, Lamp life not less than 50000 operating hours with L 70 criterion. Total Harmonic Distortion (THD) less than 15% Minimum view angle of the LED not less than 120 degree, colour Rendering Index (CRI) not less than 70, CCT 5700K-6500K, Ratio of minimum and average illumination shall be minimum 0.3, Working Temperature-30º C to 60º C, Working Humidity 10% to 90% RH and connecting upto street light feeder/junction box with & including two runs of 2.5 Sqmm PVC insulated, weather proof, multistranded aluminium conductor cable of 1100 Volts grade & testing complete all as specified & directed. Note :- (i) The contractor should give warranty for the complete fitting including its LEDs, Lens, Driver, SPD, Protection devices and all Electric/Electronics connected parts for minimum 3 (Three) years and Contractor should submit manufacturers warranty certificate for fittings for minimum 3 (Three) years in writting. Cont/--
Cont/-- (ii) The contractor should submit latest LM-79 & LM-80 reports (Test certificate) for street light fittings from NABL accredited Lab. The quoted rates shall deemed to be inclusive for above stipulations. (iii) All LED light/luminaries must meet the provision laid down in relevant ISs. (iv) LED light fittings is required to be fixed on steel tubular poles/PCC poles or swan neck swaged tubular poles with all T&P and accessories etc complete including making connection , testing etc complete. No extra payment shall be admissible on these account. (v) Contractor shall furnish a written replacement warranty to the department in favour of GE for a period of 3 (Three) years from the date of completion of the work. The complete documents regarding warranty shall be handed over to the GE at the time of execution of the items. For this purpose, contractor may obtain Warranty/ Extended warranty from the manufacturer for the above period. (vi) The warranty furnished by the contractor shall meet the reqirement in following conditions :- (a) Manufacturing defects. (b) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen of the LED/Luminaries. (vi) The consolidated rate for Srl Nos. 63.00 to 63.01 shall be quoted against Srl No. 63.00 of BOQ.ected.
All as per serial item No 63.00 & 63.01 here-in-before but 50± 2 watts rating.
All as per serial item No 63.00 & 63.01 here-in-before but 20± 2 watts rating.
Supply and fixing weather proof PVC insulated & sheathed twin core stranded aluminium conductor 10 Sqmm cable 1100 Volts grade (ISI marked) from over head conductor to street light fitting & including suitable size of PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including taking down old existing unserviceable cable all as directed. Make : Havells/ Finolex/Polycab.
ALAKNANDA ENTERPRISES
Hitesh Construction
DEMROT ELECTRICAL WORKS
M/S GAURI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .