| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.3 L+₹4.2 L (37.2%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.6 L+₹4.4 L (39.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.8 L+₹5.7 L (50.5%)Rejected-AOC 14 ILTIFATGANJ AMBEDKAR NAGAR UTTAR PRADESH 224145 UDYAM UP 04 0036158 | AMBEDKAR NAGAR | UTTAR PRADESH | 224145 | L4 | Rejected-AOC L4 | |
| 5 | L5₹17.2 L+₹6.0 L (54.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
16 Dec 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CLEANING AND MAINTENANCE OF SEWAGE SYSTEM AND REPAIRS TO MANHOLES, SEPTIC TANKS ETC IN ZONE A AND ZONE B AT MIRAN SAHIB UNDER GE JAMMU
2020_MES_396061_1
GEJC-53/2020-21
Open Tender
Civil Works
Item Rate
365 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹40,000
Yes
16 Jan 2021
18 Nov 2020
18 Dec 2020
18 Nov 2020
16 Dec 2020
2 Dec 2020
Amount
Cleaning and clearing the blockage of sewage lines of any dia, type and any depth, removing any type of blockage by roding from main holes or by flushing water with pressure pump complete all as specified and as directed.
Taking out of solid / semi solid sludge from existing main holes of any size and any depth and burying the entire sludge / sludge water into excavated pit of adequate size including excavation and covering with earth or disposing off into covered vehicles outside the periphery of defence land to a distance exceeding 1 KM including taking off RCC / Iron main holes covers and refixing the same after clearing complete all as specified and as directed.
Cleaning of Septic tanks upto and including 25 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine an jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the periphery of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
All as per Ser Item No 3.00 here-in-before but cleaning of septic tanks of 25 users to 50 users capacity complete all as specified and as directed.
All as per Ser Item No 3.00 here-in-before but cleaning of septic tanks of 50 users to 100 users capacity complete all as specified and as directed.
All as per Ser Item No 3.00 here-in-before but claning of septic tanks of 100 users to 200 users capacity complete all as specified and as directed.
All as per Ser Item No 3.00 here-in-before but cleaning of septic tanks of 200 users to 250 users capacity complete all as specified and as directed.
Cleaning of blockage of EWC / IWC / Urinal / Bathroom / Kitchen and gully trap and removing of sludge / spoil / waste to a distance exceeding 100 mtr and testing of WC Block for proper working after cleaning complete all as specified and as directed.
Notes : For Item No. 1 to 8 : (i) Cleaning and Clearing / Disposing off all the sludge / sewage contaminated water in solid / semi solid / liquid state from sewage lines, manholes etc as detailed in above item No. 1 to 8 will be carried our during the 1st 3 months from the date of commencement of work order No. 1 and there after shall be maintained for blockage free and smooth functioning of all the sewage lines and related sewage items as detailed in item No. 1 above for a period of nine months i.e. the date of completion of contract given in Work Order No. 1. Engagement 01 X Supervisor along with 02 X Sweeper cum sewage drain attendant along with T&P required on daily basis for a period of twelve months for attending the daily sewage related complaints. The complaints shall be collected daily at 08:30 hours from the office of Engr-in-Charge by Contractor / Contractor's Supervisor and shall be got signed from the user occupant after clearing the complaints. These complaint slips will also be got signed at Engr-in-Charge office daily after the satisfactory completion of each complaint. No complaint shall be kept pending / unattended for a period of 24 Hours. Any damage to manhole covers, gully trap covers, CI assess doors of CI pipes any dia, PVC pipes / fitting, 'P' traps, floor traps during the process of cleaning / clearing shall be made good by the contractor by replacing the same by new items without any extra cost to the Govt.
Excavation in trenches not exceeding 1.5m wide not exceding 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
All as per Ser Item No 10.00 here-in-before but depth exceeding 1.5m and not exceeding 3 mtr complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removal of surplus excavated soil to a distance exceeding 250m and not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Demolition / breaking of drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site all as specified of 150mm / 200mm dia pipe including demolition of cement concrete bed / haunching etc complete all as specified and as directed.
M&L concrete bed to 200mm bore pipe 1:4:8 type D-2 (using 40mm graded aggregate) including haunching against the side of pipe complete all as specified and as directed.
M&L concrete bed to 150mm bore pipe 1:4:8 type D-2 (using 40mm graded aggregate) including haunching against the side of pipe complete all as specified and as directed.
S&F and laying 200mm thick reinforced concrete pipes class NP-2 laid and jointed complete all as specified and as directed.
S&F and laying 150mm thick reinforced concrete pipes class NP-2 laid and jointed complete all as specified and as directed.
M&L 150mm dia salt glazed stoneware drain pipes laid in trenches in concrete padding jointed in cement mortar 1:1 complete all as specified and as directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quions, arches, pillars, drains etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
All as per Ser Item No 21.00 here-in-before but except bricks complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) asin coping of manholes complete all as specified and as directed.
M&L for 15mm rendering on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L providing precast cement concrete in cover slab (for manhole) 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) set in CM 1:4 complete all as specified and as directed.
M&L MS TMT bars 10mm dia and over cut to length, bend to shape etc complete binding with and including mild steel annealed wire not less than 0.09mm dia conforming TMT bars complete all as specified and as directed.
All as per Ser Item No 27.00 here-in-before but mild steel round bars 5mm dia and over up to and including 10mm dia as manholes cover handles, steps, clamps etc complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth, finished and reforming benching as required of 150mm / 200mm dia pipe complete all as specified and as directed.
Taking up or down PVC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints and removing lead of 100 / 75mm dia pipe complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 110mm dia complete all as specified and as directed.
All as per Ser Item No 31.00 here-in-before but 75mm bore including rubber ring joint with solvent adhesives complete all as specified and as directed.
S&F stack clamps out of 50mm X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of any bore pipe complete all as specified and as directed.
S&F 110mm PVC (SWR) junction single (T) equal / unequal complete all as specified and as directed.
S&F PVC (SWR) bends / shoes any radius of 75mm dia complete all as specified and as directed.
S&F PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and as directed.
All as per Ser Item No 36.00 here-in-before but 75mm dia complete all as specified and as directed.
S&F in repair water closet white vitreous china ware Orissa pattern of size 580 X 440mm with integral foot rest 'P' or 'S' trap front or back inlet including provision of PCC 1:2:4 type B-1 and provision of cement concrete bedding and making good the dismantled surface and connection flush pipe (Rate also including for taking off unhygenic old WC) 15mm dia PVC connection 450mm long complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan pedestal pattern white including fixing bolts, white / coloured plastic seat cover, CP brass jet nozzle with 600mm long PVC pipe, 15mm dia PVC connection 450mm long, making good existing area with tiles complete all as specified and as directed.
S&F in repair PVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 litres including PVC flush pipe complete all as specified and as directed.
S&F in repairs Syphonic ation type flushing kit for one piece EWC / two piece EWC for any type make of EWC including 15mm dia PVC connection as per site requirement, i.e. 300mm / 450mm / 600mm complete all as specified and as directed.
M&L removing from any height and any type of tree grown in brick masonry, behind CI pipe, parapets, shafts, etc removing root from wall by chiselling carefully without damaging the structure and making good by brick work in CM 1:4 including toothing and bonding (Area for removing of tree not exceeding 1.00 Sqm) complete all as specified and as directed by Engr-in-Charge.
ASHFAQ AHMED MANHAS
M/S CHOUDHARY BUILDERS
M/S R S CONSTRUCTION CO
N S MANHAS
Bidder Name
N S MANHAS
ASHFAQ AHMED MANHAS
Hi Tech Engineers
M/S R S CONSTRUCTION CO
M/S CHOUDHARY BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .