| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹31.3 L+₹1.2 L (4.03%)Admitted-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Admitted-Finance | |
| 3 | L3₹32.6 L+₹2.4 L (8.09%)Admitted-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Admitted-Finance | |
| 4 | L4₹33.0 L+₹2.9 L (9.64%)Admitted-Finance KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Admitted-Finance | |
| 5 | L5₹36.1 L+₹6.0 L (19.8%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Singla Electricals L2 | UNITED ENGINEERING CORPORATION L3 | M/s BHUPINDRA ENGINEERING WORKS L4 | RUCHIKA CONSTRUCTIONS L6 | N.R.Builders L5 | Kaul Enterprises L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install galvanized steel High Mast of 16 Mtrs height lighting system in two section, 3 mm section thickness, top dia not less than 150mm & bottom dia not less than 340 mm with its accessories including foundation bolts manufactured from special steel and Hot Dip Galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel control and raising & lowering mechanism for integral power tool, Twin aviation Lamp etc. Mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 minimum 18 km per hour. It shall also include accessories for high mast including head frame, steel wire rope (7/19 construction) double drum which is operated by motor gear mechanism with inbuilt starter, Timer and feeder piller panel, Galvanized Lantern carriage arrangement 'suitable for 08 Nos, including panel, luminaires Symmetrically & its control gear boxes and with 03 point suspension system. The mast shall have an integral power tool installed inside the base compartment for its operation. (Material construction of high mast sheet will be of BSEN 10025 / IS 5986 or equivalent) with wiring cable for luminaire connection including suitable size of foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T / Sq mtr at 2 meter depth and using RCC M-25 grade (design mix) concrete with reinforcement,form work, earthwork, base above the ground with tiles complete all as per manufacturers instructions and as directed by Eng-in-charge.
Note:-
(a) Making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation demeed to be included in the unit rate.
(b) Cable of required size and length from top to bottom for connection of LED flood light an related switchgears included in above quoated rate. Make- Orient/Crompton/Bajaj and equivalent | 8 | Each | 2,65,000 ₹21,20,000 Lowest | 2,90,500 ₹23,24,000 | 2,80,000 ₹22,40,000 | 3,40,000 ₹27,20,000 | 2,99,000 ₹23,92,000 | 2,65,000 ₹21,20,000 Lowest |
| 2.00 | Supply and fixing LED flood light fittings with and including lamp 200/ 210W rating, separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only, IP Protection not less than IP 66, Protection should be Class I,Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaries with separate external surge protection device 4 Kv to 10 kv rating and separate connector block for termination of incoming cable connection all as specified and directed. Make- Orient/Crompton/Bajaj and equivalent | 64 | Each | 6,800 ₹4,35,200 | 6,350 ₹4,06,400 Lowest | 7,200 ₹4,60,800 | 7,200 ₹4,60,800 | 9,000 ₹5,76,000 | 6,500 ₹4,16,000 |
| 3.00 | Cable XLPE insulated screened PVC bedded, galvanised steel strip elect power cables 1100V grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as directed by Engr-in-Charge. | 1,260 | RM | 220 ₹2,77,200 | 187 ₹2,35,620 Lowest | 270 ₹3,40,200 | 250 ₹3,15,000 | 260 ₹3,27,600 | 190 ₹2,39,400 |
| 4.00 | Excavation in trenches in any type od soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr in wide for laying of Cables, RCC/Steel tubular poles/stays and struts etc getting out includingtrimming sides wide forming bottom surface all as specified and directed at site. | 323.19 | Cum | 200 ₹64,638 | 170 ₹54,942.3 | 100 ₹32,319 | 200 ₹64,638 | 50 ₹16,159.5 Lowest | 90 ₹29,087.1 |
| 5.00 | Returning, filling in including spreading leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested, all as specified and directed st site. | 320.12 | Cum | 30 ₹9,603.6 | 60 ₹19,207.2 | 25 ₹8,003 | 50 ₹16,006 | 50 ₹16,006 | 20 ₹6,402.4 Lowest |
| 6.00 | Removal of excavated surplus materail to a distance n. exc. 50 mtr away in layer n. exc. 25 cm from the starting point all as directed by Engr-in-Charge. | 3.07 | Cum | 30 ₹92.1 | 60 ₹184.2 | 25 ₹76.75 | 50 ₹153.5 | 50 ₹153.5 | 20 ₹61.4 Lowest |
| 7.00 | Supplying and laying double wall corrugated (DWCP), Non-metalic, resistance to compression : type 450 resistance to impact, normal resistance to bending : pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion : without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 77mm minimum inside dia 63mm conforming to IS-16205 (Part-24) 2017 including necessary jointing material i.e snap fir coupler with rubber ring, realing plug, tees, bend, angel bend etc for passing electrical cable up to 25 sqmm 4 core complete all as directed. | 1,209.6 | RM | 110 ₹1,33,056 | 105 ₹1,27,008 | 115 ₹1,39,104 | 80 ₹96,768 Lowest | 160 ₹1,93,536 | 90 ₹1,08,864 |
| 8.00 | M & L for boring of holes under road/ drain PCC path by manual method or trenchless technology including not less than 100 mm dia light grade pipe GI tubing for cable protection all as specified and direct by Engr-in-Charge. | 20 | RM | 300 ₹6,000 | 400 ₹8,000 | 300 ₹6,000 | 200 ₹4,000 | 100 ₹2,000 Lowest | 800 ₹16,000 |
| 9.00 | Supplu and laying for GI pipe light grade 40 mm dia, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/crossing nallah etc all as specified and directed by Engr-in-charge. | 17.5 | RM | 500 ₹8,750 | 362 ₹6,335 | 300 ₹5,250 Lowest | 450 ₹7,875 | 300 ₹5,250 Lowest | 400 ₹7,000 |
| 10.00 | Earthing complete with galvanised steel earth plate electrode 60 × 60 cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and includeing galvanised earth lead GI Strip of size 32x6mm by means of GI bolt/snuts/washers, protection by 40 mm bore GI light grade pipe from earth plate & upto3m long pole fixed 2 clamp made from mild steel flat iron 32 x 6 mm bolts, nuts, washer etc, earth plate shall be surrounded by alternate layer of charcol of coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plte No 3 of SSR Part-I,
Note :
(a) PCC chamber shalll be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
(b) Earthing for lighting protection is also include in the above items. | 8 | Each Job | 5,500 ₹44,000 | 5,111 ₹40,888 | 4,500 ₹36,000 | 3,500 ₹28,000 Lowest | 6,000 ₹48,000 | 4,800 ₹38,400 |
Tender Value
₹39.2 L
EMD Value
₹78,500
Closing Date
11 Aug 2026, 6:00 pmClosed
GARRISON ENGINEER ABOHAR
GARRISON ENGINEER ABOHAR ABOHAR MILITARY STATION PIN-152116
PROVISION OF HIGH MAST SECURITY LIGHT AT VARIOUS LOCATION AT FAZILKA MILITARY STATION
2026_MES_778675_1
TOKEN NO GE ABH 17/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
FAZILKA MIL STN
As per NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹78,500
Yes
20 Aug 2026
15 Jul 2026
13 Aug 2026
15 Jul 2026
11 Aug 2026
29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and install galvanized steel High Mast of 16 Mtrs height lighting system in two section, 3 mm section thickness, top dia not less than 150mm & bottom dia not less than 340 mm with its accessories including foundation bolts manufactured from special steel and Hot Dip Galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel control and raising & lowering mechanism for integral power tool, Twin aviation Lamp etc. Mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 minimum 18 km per hour. It shall also include accessories for high mast including head frame, steel wire rope (7/19 construction) double drum which is operated by motor gear mechanism with inbuilt starter, Timer and feeder piller panel, Galvanized Lantern carriage arrangement 'suitable for 08 Nos, including panel, luminaires Symmetrically & its control gear boxes and with 03 point suspension system. The mast shall have an integral power tool installed inside the base compartment for its operation. (Material construction of high mast sheet will be of BSEN 10025 / IS 5986 or equivalent) with wiring cable for luminaire connection including suitable size of foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T / Sq mtr at 2 meter depth and using RCC M-25 grade (design mix) concrete with reinforcement,form work, earthwork, base above the ground with tiles complete all as per manufacturers instructions and as directed by Eng-in-charge.
Note:-
(a) Making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation demeed to be included in the unit rate.
(b) Cable of required size and length from top to bottom for connection of LED flood light an related switchgears included in above quoated rate. Make- Orient/Crompton/Bajaj and equivalent | 7 | Each | - | - |
| 2 | Supply and fixing LED flood light fittings with and including lamp 210W rating, separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only, IP Protection not less than IP 66, Protection should be Class I,Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaries with separate external surge protection device 4 Kv to 10 kv rating and separate connector block for termination of incoming cable connection all as specified and directed. Make- Orient/Crompton/Bajaj and equivalent | 56 | Each | - | - |
| 3 | Cable XLPE insulated screened PVC bedded, galvanised steel strip elect power cables 1100V grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as directed by Engr-in-Charge. | 1,260 | RM | - | - |
| 4 | Excavation in trenches in any type od soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr in wide for laying of Cables, RCC/Steel tubular poles/stays and struts etc getting out includingtrimming sides wide forming bottom surface all as specified and directed at site. | 323.19 | Cum | - | - |
| 5 | Returning, filling in including spreading leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested, all as specified and directed st site. | 320.12 | Cum | - | - |
| 6 | Removal of excavated surplus materail to a distance n. exc. 50 mtr away in layer n. exc. 25 cm from the starting point all as directed by Engr-in-Charge. | 3.07 | Cum | - | - |
| 7 | Supplying and laying double wall corrugated (DWCP), Non-metalic, resistance to compression : type 450 resistance to impact, normal resistance to bending : pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion : without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 77mm minimum inside dia 63mm conforming to IS-16205 (Part-24) 2017 including necessary jointing material i.e snap fir coupler with rubber ring, realing plug, tees, bend, angel bend etc for passing electrical cable up to 25 sqmm 4 core complete all as directed. | 1,209.6 | RM | - | - |
| 8 | M & L for boring of holes under road/ drain PCC path by manual method or trenchless technology including not less than 100 mm dia light grade pipe GI tubing for cable protection all as specified and direct by Engr-in-Charge. | 20 | RM | - | - |
| 9 | Supplu and laying for GI pipe light grade 40 mm dia, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/crossing nallah etc all as specified and directed by Engr-in-charge. | 17.5 | RM | - | - |
| 10 | Earthing complete with galvanised steel earth plate electrode 60 × 60 cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and includeing galvanised earth lead GI Strip of size 32x6mm by means of GI bolt/snuts/washers, protection by 40 mm bore GI light grade pipe from earth plate & upto3m long pole fixed 2 clamp made from mild steel flat iron 32 x 6 mm bolts, nuts, washer etc, earth plate shall be surrounded by alternate layer of charcol of coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plte No 3 of SSR Part-I,
Note :
(a) PCC chamber shalll be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
(b) Earthing for lighting protection is also include in the above items. | 7 | Each Set | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender.pdf
Tender Documents • 1.58 MB
BOQ_872135.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .