| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC | ₹1.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.1 L+₹16,243 (8.60%)Rejected-AOC | ₹2.1 L+₹16,243 (8.60%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.4 L+₹50,718 (26.9%)Rejected-AOC V P O MILLAH TEHSIL SHILLAI DISTT SIRMOUR 173029 | SIRMAUR | HIMACHAL PRADESH | 173029 | ₹2.4 L+₹50,718 (26.9%) | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | CHANDEL ELECTRICAL ENGG WORKS L1 | kuldeep singh L3 | Ateesh Sharma L2 |
|---|---|---|---|---|---|---|
| 1.00 | Rewiring for light point/ fan point/exhaust fan/ call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible ) copper conductor cable in existing surface/ recessed steel/ PVC conduit and earthing the light point with 1.5 mm HRFRLS/ PVC insulated single core copper conductor cable including dismantling of existing wire as required (including switch and bakelite sheet etc. ) complete in all respect as per satisfaction of Engineer-in-charge Group-C | 16 | Each | 1,050 ₹16,800 | 950 ₹15,200 | 940 ₹15,040 Lowest |
| 2.00 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sqmm HRFRLS / PVC insulated single core copper conductor cable as required complete in all respect as per satisfaction of Engineer-in-charge. a). Group C | 10 | Each | 775 ₹7,750 Lowest | 800 ₹8,000 | 800 ₹8,000 |
| 3.00 | Wiring for power plug with 2x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge. | 45 | Running metre | 245 ₹11,025 Lowest | 275 ₹12,375 | 270 ₹12,150 |
| 4.00 | Wiring for power plug with 4x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 2 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge. | 28 | Running metre | 400 ₹11,200 | 375 ₹10,500 | 360 ₹10,080 Lowest |
| 5.00 | Wiring for circuit / sub-main with 2x1.5 Sqmm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No. HRFRLS / PVC insulated single core copper conductor cable of same size for earthing as required. complete in all respect as per satisfaction of Engineer-in-charge. | 12 | Running metre | 150 ₹1,800 | 140 ₹1,680 Lowest | 140 ₹1,680 Lowest |
| 6.00Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. complete in all respect as per satisfaction of Engineer-in-charge | ||||||
| 6.10 | a) 3 x 1.5 Sqmm | 21 | Running metre | 128 ₹2,688 | 125 ₹2,625 | 120 ₹2,520 Lowest |
| 6.20 | b). 3 x 4.00 Sqmm | 20 | Running metre | 200 ₹4,000 | 195 ₹3,900 | 190 ₹3,800 Lowest |
| 6.30 | c). 5 x 10.00 Sqmm | 3 | Running metre | 900 ₹2,700 | 875 ₹2,625 | 870 ₹2,610 Lowest |
| 7.00Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-as required complete in all respect as per satisfaction of Engineer-in-charge. | ||||||
Tender Value
₹1.7 L
EMD Value
₹3,400
Closing Date
18 Mar 2026, 10:00 amClosed
Executive Engineer (C)
o/o Estate Organization UHF Nauni Solan
Providing electrical installation in Redentology laboratory for the Deptt.of entomology at Dr YSP UHF Nauni solan
2026_YSPU_130620_1
No.UHF/Const-1/Partfile/2025/ 3392dated 06.03.2026
Open Tender
Electrical Works
Item Rate
30 days
Nauni Solan
Please refer Tender documents.
4 documents required · 4 mandatory
₹700
EE(D)
₹3,400
25 Mar 2026
6 Mar 2026
18 Mar 2026
6 Mar 2026
18 Mar 2026
6 Mar 2026
Rewiring for light point/ fan point/exhaust fan/ call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible ) copper conductor cable in existing surface/ recessed steel/ PVC conduit and earthing the light point with 1.5 mm HRFRLS/ PVC insulated single core copper conductor cable including dismantling of existing wire as required (including switch and bakelite sheet etc. ) complete in all respect as per satisfaction of Engineer-in-charge Group-C
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sqmm HRFRLS / PVC insulated single core copper conductor cable as required complete in all respect as per satisfaction of Engineer-in-charge. a). Group C
Wiring for power plug with 2x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for power plug with 4x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 2 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for circuit / sub-main with 2x1.5 Sqmm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No. HRFRLS / PVC insulated single core copper conductor cable of same size for earthing as required. complete in all respect as per satisfaction of Engineer-in-charge.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. complete in all respect as per satisfaction of Engineer-in-charge
a) 3 x 1.5 Sqmm
b). 3 x 4.00 Sqmm
c). 5 x 10.00 Sqmm
Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-as required complete in all respect as per satisfaction of Engineer-in-charge.
a). 180mm.x100mm.x60mm. Deep
b). 200mm.x150mm.x75mm. Deep
Supplying & fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
a). S.P. 5/6 amps one way switch, piano type.
b). S.P. 15/16 amps one way switch, porcelain base / piano type.
c). 5 pin 5/6 amps socket outlet, porcelain base / piano type..
d). 6 pin 15/16 amps socket outlet, porcelain base / piano type
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge
Supplying and fixing Ceiling rose on the existing junction box/wooden block including connection etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Supplying and fixing Bakelite batten/angle holder including connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Suppling and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S.angle iron 50mmX 50mmX6mm thick duly welded complete with 3mm thick M.S. sheet fixed with hinges as open able front complete with locking arrangement including painting and bonding to the existing earth as required in all respect as per satisfaction of Engineer-in-charge
Supplying and erection of 6 to 32 amp rating 10 KA, breaking capacity 240 volts, C curves miniature circuit breakers of following poles in the existing MCB DB complete with connections, testing and commissioning etc. complete in all respect as per satisfaction of Engineer-in-charge. a). Single pole Cat. –A
Supplying and fixing following rating, Four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge a). 63 Amps. Cat - A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with onnections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a). 63 Amp Cat. –A
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required complete in all respect as per satisfaction of Engineer-in-charge a). Double door-4 way (8+12),horizontal type outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required complete in all respect as per satisfaction of Engineer-in-charge a). Double door-4 way (8+12),horizontal type
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, ncluding accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) as required complete in all respect as per satisfaction of Engineer-in-charge
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required complete in all respect as per satisfaction of Engineer-in-charge
Supplying and laying 6 SWG GI wire at 0.50 Rmt. below ground level for earth electrode conductor, including soldering etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required complete in all respect as per satisfaction of Engineer-in-charge
Providing, laying & fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size complete in all respect as per satisfaction of Engineer-in-charge. a) Armoured cable 25 Sqmm (3.5 core).
Providing & installation of stationary storage type electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing & fixing of Non-return valve, Dead weight safety valve, 2 No. C.P. connection rods 18” long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) 10 Liter capacity water heater (Cat-A).
Providing, Installation, testing & commissioning of ceiling fan without five step electronic regulator, including wiring the down rods of length as per requirement of site condition with 16/0.20mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required complete in all respect as per satisfaction of Engineer-in-charge(Usha/ bajaj/ phillip’s/ Havell’s make).. a) Ceiling fan 1200mm sweep, category – A.
Supplying installation testing & commissioning of PVC Exhaust fan (150mm) as required complete in all respect as per satisfaction of Engineer-in-charge. Make- Usha/Havells/ Crompton/Orient..
Supplying, Installation, testing & commissioning of indoor lighting LED Luminiarie 36 watt decorative ultra slim polycarbonate LED lighting fixture with high lumen output as required complete in all respect as per satisfaction of Engineer-in-charge. Make ( Panasonic/ bajaj/ greatwhite/ havells/ jaquar/wipro )
Supplying, Installation, testing & commissioning of outdoor street light 50 watt 6500 K IP 65robust heat sink along with class leading IP, IK & surge protections for long lasting performance as required complete in all respect as per satisfaction of Engineer-in-charge. Make – (Panasonic/ bajaj/ Greatwhite/ Havells/ jaquar /wipro).
Supplying, & Erection of street light bracket made of GI Pipe ‘A’ class of suitable length and dia the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete as required complete in all respect as per satisfaction of Engineer-in-charge. a) 32mm dia GI pipe heavy glass
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.45 MB
tenderdoccc.pdf
Tender Documents • 5.21 MB
BOQ_193122.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .