Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹22.0 L+₹29,362 (1.35%)Rejected-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹24.5 L+₹2.9 L (13.2%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹25.9 L+₹4.2 L (19.5%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹26.6 L+₹4.9 L (22.5%)Rejected-AOC 173 RASTA PETH NIKHIL APARTMENT SHIRAL SETH CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
18 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8390 MAINT TO STREET / ROAD WAY LUMINARIES / REPAIR TO SECURITY LIGHT FITTING, CABLE, POLES, STREET LIGHT LUMINARIES AND MISC WORK IN WR STN, FAMILY QTR OF SPS LINE, NGBM, OGBM, NP LINES, OFFRS ACCN OF AICTS AND OTHER CONNECTED AREA UNDER GE S PUNE
2022_MES_572002_1
8390 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹82,000
6 Mar 2023
29 Dec 2022
20 Jan 2023
29 Dec 2022
18 Jan 2023
12 Jan 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and exc. 1.5 m depth but not exc. 3.0m for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed.
Dismantling unserviceable steel poles/struts any size including necessary excavation and earth work removing from site complete all as specified and as directed.
Supply, install and errect in true vertical position steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mm X 300mm, final taper plug, Pole cap, bolts, nuts, washers and screws, Pole made out of ERW MS tubing conforming to IS-2713 (Part-II) 1980 type 410 SP-31 (09 Mtrs Long) poles including drilling of holesof required size for fixing cross arms etc. painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete. Painting three black / red / bands at lower portion of pole of 300mm spacing, painting pole No. with black paint at suitable height complete all as specified and as directed. (Note:- Excavation / earth work and PCC will be measured and paid separately under respective items of relevant Sch. of BOQ)
Taking down old unserviceable cable and Supply, lay, joint, test and commissioning of LT under ground cable XLPE insulated and sheathed heavy duty armoured with aluminium conductor 1100 volt grade complete with cable glands, lugs etc complete of following size :-
06 sqmm 4 core
16 Sqmm 4 core
25 Sqmm 4 core
Material and labour for Reinforced concrete pipes, class NP2 with one collar per length of pipe of dia 100mm, half round (02 Nos for top & bottom) complete all as specified and as directed.
Supply and lay in trenches for cable protection G I Tubing light grade complete with all accessories etc of the following size : -
50 mm bore
80 mm bore
S&F in repair Integral LED Street Light Luminaire 25 W comprising of epoxy powder coated pressure die cast aluminium housing, Enclosed with toughened glass cover in frame including 40 mm dia GI Pipe 1.2 mtr long, light grade complete with accessories complete all as specified and directed by Engr in charge. (Make - HALONIX CAT NO- HLSLD-09H-25-CWL-R or equivalent in Philips/ Wipro/Havells)
S&F in repair Integral LED Street Light Luminaire 60 W with IP66 protection, comprising of epoxy powder coated pressure die cast aluminium housing, Enclosed with toughened glass cover in frame including 50 mm or above dia suitable for new fitting size GI Pipe 1.2 mtr long, light grade complete all as specified and directed by Engr in charge. (Make - HALONIX CAT NO- HLSLD-01-60-CWL-R or equivalent in Philips/ Wipro/Havells)
S&F in repair LED Street Light Luminaire 90 W with IP66 protection, comprising of epoxy powder coated pressure die cast aluminium housing, Enclosed with toughened glass cover in frame including 50 mm or suitable dia for new fitting size GI Pipe 1.2 mtr long light grade complete with accessories all as specified and directed by Engr in charge. (Make- HALONIX CAT NO- HLSLD-06-90-CWL-R-SH or equivalent in Philips/ Wipro)
S&F in repair LED flood lights fitting 30 watts highly efficient with integral type mid power made of pressure die cast aluminium housing with toughened glass and IP66 protection complete all as specified and as directed. (Make - CAT Part No HLFLD-ML17-30-CW-R01 of Halonix or equivalent in philips/Havells/Polycab)
S&F in repair LED flood lights fitting 50 watts highly efficient with integral type mid power made of pressure die cast aluminium housing with toughened glass and IP66 protection complete all as specified and as directed. (Make - CAT Part No HLFLD-ML11-50-CWL-R of Halonix or equivalent in philips/Havells/Polycab)
S&F in repair LED flood lights fitting 100 watts High power LED installed on roof/ Pole/ high mast upto 15 mtr height with highly efficient LED made of pressure die cast aluminium housing, suitable lens and toughened glass with IP66 protection complete all as specified and as directed. Note- Any T&P/ladder required for replacement of lights on high mast upto 15 mtr height is deemed to be included in the quoted rate. (Make - CAT Part No HLFLD-ML11-100-CWL-R of Halonix or equivalent in Philips/Havells/Wipro)
S&F in repair LED flood lights fitting 150 watts High power LED installed on roof/ Pole/ high mast upto 15 mtr height with highly efficient LED made of pressure die cast aluminium housing, suitable lens and toughened glass with IP66 protection complete all as specified and as directed. (Note- Any T&P/ladder required for replacement of lights on high mast upto 15 mtr height is deemed to be included in the quoted rate) (Make - CAT Part No HLFLD-ML15-150-CWL-R-B of Halonix or equivalent in philips/Havells/Wipro)
S& F in repair 120 watt LED ornamental street light with spun aluminium designed housing with clear acrylic for city beautification complete all as specified and directed by Engr in charge. (Make- HALONIX CAT NO- HLOSL-04-120-CWL or equivalent in philips/ Wipro/Havells)
M&L for replacement of PVC insulated and sheathed 1100 volt grade of size copper wire 2.5 sqmm, 3 core multistranded for connection of street light fitting from over head line/ pole box complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable old bracket from street light pole and supply and fix new street light bracket (as directed by Engineer-in-Charge ) made out of MS pipe heavy duty 50 mm dia and not exceeding 1.5 mtr in length for fixing of fittings with two nos of ms clamp fabricated out of MS flat of suitable size including nut, bolt, washers etc to fix the bracket on pole all as specified and directed by Engr-in-charge.
M&L for attending day to day complaints of any type, any wattage and any height light fittings of any make/type/ capacity and repairing for proper functioning including replacing small parts. One electrician to be present daily during the contract period for attending the complaints with ladder and tools for repairing of street light / flood light/ any other lights or any emergent complaints assigned for complete period of contract complete all as directed by Engr-in-Charge. (Note :- Cost of minor spares i.e. insulation tape etc is deemed to be included in the quoted rate)
Supply and fix in repairs garden security light fittings LED type suitable for 10 watt LED inverted pyramid tripod type LED bollard with soft 360 light, IP 65 protection, resistance to corrosion complete with necessary fixing arrangements, PCC (1:3:6) type C-1 as in foundation suitable for operation on 230 volt 50 Hz AC supply including all standard fittings and fixture all as per the direction of Engineer-in-Charge (Make :- Crompton Cat No LBLSN-10-CDL or same type in Wipro/ Philips/ Halonix)
Supply and fix in repairs junction boxes out door type weather proof with fixing accessories made out of moulded PVC size 250x200x80 mm to be fixed at the height of 1 M from bottom of street light pole complete with wiring, arrangement for MS Clamp, cable entery/exit, 01 No. MCB SP 6 Amps, 4 pole connector for fixing cable etc complete all as specified and directed.
M&L for taking down existing LED fitting 18/20 watt and supply and fix new 20 Watt capacity indoor decorative LED engineering plastic batten with opal diffuser of IP20 protection including standard accessories as directed by Engineer-in-Charge (Make - Halonix cat no HLB-08-20-CW-IP or same type in all respect of Havells/Philips/Wipro)
Taking down unserviceable post top/gate light and supply and fix new 40 watts LED Post top light fitting with die cast aluminium spigot, spun aluminium powder coated top cover Aluminium PDC heat sink, opal PC diffuser and clear acrylic for 360 degree indirect light, IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, including necessary fixing arrangements as required at site complete all as specified and as directed by Engineer-in-Charge. (Make - Halonix cat no HLPT-04-40-CW or same type in all respect in Havells/Wipro/Philips)
Taking down unserviceable post top/gate light and supply and fix new 70 watts LED Post top light fitting with die cast aluminium spigot, spun aluminium powder coated top cover Aluminium PDC heat sink, opal PC diffuser and clear acrylic for 360 degree indirect light, IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, including necessary fixing arrangements as required at site complete all as specified and as directed by Engineer-in-Charge. (Make - Halonix cat no HLPT-04-70-CW or same type in all respect in Havells/Wipro/Philips)
Supply and fix in repairs electronic driver suitable for 20/25 watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
Supply and fix in repairs electronic driver suitable for 60 to 72 Watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
Supply and fix in repairs electronic driver suitable for 90 to 120 watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
Supply and fix in repairs electronic driver suitable for 140 to 160 watt LED flood light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
Material and labour for painting of steel tubular pole upto 9mtr height including cross arm, clamp, back plate etc in situ on with one under coat and one finishing coat with aluminium paint after cleaning, preparation of surface including making alternate yellow and black strip 30 cm wide 5 Nos. with two coats of synthetic enamel paint complete all as specified and as directed.
M&L for testing and fault locating of HT / LT cable with the help of bringing Cable fault locating machine at site complete all as specified and as directed. (Note - The machine for locating of fault will be arranged by the contractor shall be deemed in quoted rate)
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 150 to 240 Sqmm 3.5 core including all required accessories complete all as specified and as directed.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 95 to 120 Sqmm 3.5 core including all required accessories complete all as specified and as directed.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 35 to 70 Sqmm 3.5 core including all required accessories complete all as specified and as directed.
Supply & fix timeline distribution board, timeline 40 Amps 3 pole, 230 volts with analog time switch conforming to Cat Part No TL040ABO of Indo Asian or equivalant to L&T/Havells/Schneider to be fixed on wall and pole with mounting arrangement complete all as directed by Engrs in charge. (Note- The distribution board shall be mounted on angle iron frame made out of 40 mm x 5mm angle iron 30cm on ground and 40 cm above ground surface complete including necessary PCC 1:2:4 type B-1 required for grouting of angle iron frame)
Supply & fix timeline distribution board ,timeline 40 amps 3 pole, 230 volts with Astronomincal time switch conforming to Cat Part No TL040ASO of Indo Asian or equivalant to L&T/ Havells/ Schneider, to be fixed on wall and pole with mounting arrangement all as directed by Engrs in charge. (Note- The distribution board shall be mounted on angle iron frame made out of 40 mm x 5mm angle iron 30cm on ground and 40 cm above ground surface complete including necessary PCC 1:2:4 type B-1 required for fixing of angle iron frame)
Supply and fix in repairs MCB SPN 20-40 Amps, 230 volts, 10 KA, 'C' series complete all as specified and as directed.
Supply and fix in repairs MCB TPN 32-40 Amps, 415Volts complete all as specified and as directed.
Supply and fix in replaement of MCCB 250 Amps, 25 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replaement of MCCB 200 Amps, 25 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replaement of MCCB 63 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replaement of MCCB 100 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replaement of MCCB 125 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bats at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.)
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing with 4 mm dia galvanised iron or steel wire
Leo Enterprises
metro electrical services
RELIABLE ENTERPRISES
M/S - SUJIT ELECTRICALS
Techmat trading solution
REKHA ELECTRICALS
Mahindra Electric Stores
TULAJA ENTERPRISES
CHAITANYA WINDWELL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .