Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹79.2 CrAdmitted-Finance INFINITY THINK TANK TOWER II 10TH FLOOR PLOT NO A3 BLOCK G SECTOR V SALT LAKE CITY KOLKATA 700091 WB | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹79.2 Cr | Admitted-Finance |
| 2 | ₹80.0 CrAdmitted-Finance T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹80.0 Cr | Admitted-Finance |
| 3 | ₹80.7 CrAdmitted-Finance | ₹80.7 Cr | Admitted-Finance |
| 4 | ₹81.3 CrAdmitted-Finance | ₹81.3 Cr | Admitted-Finance |
| 5 | Rejected-Technical 4A SWAIKA CENTRE POLLOCK STREET DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | Shyama Power India Limited | TECHNO POWER ENTERPRISES PVT LTD | T and T Projects Ltd | ASHOKA BUILDCON LIMITED |
|---|---|---|---|---|---|---|---|
| 1.00Supply Portion | |||||||
| 2.0011 KV Feeder (Reconductoring) (59.2 CKm) | |||||||
| 3.00 | 9.0 m S.T.P. (410:SP-31) | 1 | Nos | 1,91,54,515.2 ₹1.9 Cr | 1,71,91,561.6 ₹1.7 Cr | 1,58,04,221.44 ₹1.6 Cr | 1,58,14,699.84 ₹1.6 Cr |
| 4.00 | Galvanised Pole top bracket | 1 | Nos | 3,96,782.08 ₹4.0 L | 3,63,251.2 ₹3.6 L | 2,39,606.08 ₹2.4 L | 2,44,496 ₹2.4 L |
| 5.00 | Galvanised Clamp for Pole top Bracket | 1 | Nos | 1,12,468.16 ₹1.1 L | 1,80,228.48 ₹1.8 L | 1,60,668.8 ₹1.6 L | 1,64,161.6 ₹1.6 L |
| 6.00 | Galvanised Cross arm (75X40)mm | 1 | Nos | 10,19,897.6 ₹10.2 L | 9,33,974.72 ₹9.3 L | 10,41,552.96 ₹10.4 L | 10,66,002.56 ₹10.7 L |
| 7.00 | Galvanised Back clamp for X-arm | 1 | Nos | 2,24,936.32 ₹2.2 L | 3,60,456.96 ₹3.6 L | 3,21,337.6 ₹3.2 L | 3,28,323.2 ₹3.3 L |
| 8.00 | Galvanised 2.2m D.P. channel X-arm (75X40) mm | 1 | Set | 11,73,493.48 ₹11.7 L | 10,75,614.84 ₹10.8 L | 11,00,609.6 ₹11.0 L | 11,26,864.6 ₹11.3 L |
| 9.00 | 11 KV Disc. Insulator (Complete Set i/c Tension clamps, Hardware) | 1 | Set | 7,16,362.66 ₹7.2 L | 8,10,703.66 ₹8.1 L | 7,03,154.92 ₹7.0 L | 7,19,507.36 ₹7.2 L |
| 10.00 | 11 KV Insulator with Pin | 1 | Nos | 8,68,310.08 ₹8.7 L | 9,79,782.32 ₹9.8 L | 8,27,241.36 ₹8.3 L | 8,47,775.72 ₹8.5 L |
Tender Value
₹83.8 Cr
EMD Value
₹1.7 Cr
Closing Date
17 Jan 2023, 2:00 pmClosed
Managing Director, MSPDCL
Secure Office Complex, 3rd Floor, North AOC, A.T. Line Imphal West, Manipur-795001
The Infrastructure strengthening works under RDSS of Senapati, Kangpokpi, Ukhrul and Kamjong Districts of Manipur on turn-key basis.
2022_MSPDC_1985_3
2/228(RDSS-INFRA)/2022-MSPDCL
Open Tender
Electrical Works
1095 days
As per NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹25,000
Managing Director, MSPDCL
₹1.7 Cr
MSPDCL
8 Feb 2023
15 Dec 2022
18 Jan 2023
15 Dec 2022
17 Jan 2023
28 Dec 2022
27 Dec 2022
Supply Portion
11 KV Feeder (Reconductoring) (59.2 CKm)
9.0 m S.T.P. (410:SP-31)
Galvanised Pole top bracket
Galvanised Clamp for Pole top Bracket
Galvanised Cross arm (75X40)mm
Galvanised Back clamp for X-arm
Galvanised 2.2m D.P. channel X-arm (75X40) mm
11 KV Disc. Insulator (Complete Set i/c Tension clamps, Hardware)
11 KV Insulator with Pin
ACSR Conductor (Rabbit)
Isolator with X-arm etc.
Stay Set complete with stay wire, base plate, stay rod etc.
Galvanised Stay Clamp
Galvanised Bracing for D.P. Structure, 50X50X6mm M.S. Angle
Galvanised Clamp for D.P. Bracing
Galvanised Anti Climbing device complete
Earthing set complete with G.I. wire
Guarding at crossing with G.I. wire
Nuts, Bolts, MS flat as support for item No.3 jointing sleeves etc.
Al. Binding wire, UPG clamps etc.
Sundries like pole painting, Danger plate, Number Plate etc.
11 KV Feeder (Bifurcation) (165.7 CKm)
9.0 m S.T.P. (410:SP-31)
Galvanised Pole top bracket
Galvanised Clamp for Pole top Bracket
Galvanised Cross arm (75X40)mm
Galvanised Back clamp for X-arm
Galvanised 2.2m D.P. channel X-arm (75X40) mm
11 KV Disc. Insulator (Complete Set i/c Tension clamps, Hardware)
11 KV Insulator with Pin
ACSR Conductor (Rabbit)
Isolator with X-arm etc.
Stay Set complete with stay wire, base plate, stay rod etc.
Galvanised Stay Clamp
Galvanised Bracing for D.P. Structure, 50X50X6mm M.S. Angle
Galvanised Clamp for D.P. Bracing
Galvanised Anti Climbing device complete
Earthing set complete with G.I. wire
Guarding at crossing with G.I. wire
Nuts, Bolts, MS flat as support for item No.3 jointing sleeves etc.
Al. Binding wire, UPG clamps etc.
Sundries like pole painting, Danger plate, Number Plate etc.
AB Cable - replacement of LT bare conductors
AB Cable (3x95+1x70)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (105 CKm)
8.0 m S.T.P.(410:SP-14)
M.S. cross arm (75X40) mm, 510 mm long
Back clamp for cross arm
Dead end fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
Suspension fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
AB Cable (3x95+1x70)Sq.mm
SMC Box for 200 Amps 300x200x100 box size minimum alongwith 25X8 Aluminium Bus Bar for 3 phase connection of 4 Nos.
Insulation piercing connector suitable for AB Cable (95/70 Sq.mm. Main & Branch) as per TS & Construction Standard.
Earthing set complete with G.I. wire.
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
Stay set complete with stay wire and insulator clamp etc.
Bolts & Nuts with washer
Sundaries,Pole painting, Danger plate, Number Plate etc.
AB Cable (3x70+1x50)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (246 CKm)
8.0 m S.T.P.(410:SP-14)
M.S. cross arm (75X40) mm, 510 mm long
Back clamp for cross arm
Dead end fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
Suspension fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
AB Cable (3x70+1x50)Sq.mm
SMC Box for 200 Amps 300x200x100 box size minimum alongwith 25X8 Aluminium Bus Bar for 3 phase connection of 4 Nos.
Insulation piercing connector suitable for AB Cable (70/50 Sq.mm. Main & Branch) as per TS & Construction Standard.
Earthing set complete with G.I. wire.
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
Stay set complete with stay wire and insulator clamp etc.
Bolts & Nuts with washer
Sundaries,Pole painting, Danger plate, Number Plate etc.
AB Cable (3x50+1x35)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (163 CKm)
8.0 m S.T.P.(410:SP-14)
M.S. cross arm (75X40) mm, 500 mm long
Back clamp for cross arm
Dead end fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
Suspension fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards :
AB Cable (3x50+1x35)Sq.mm
SMC Box for 200 Amps 300x200x100 box size minimum alongwith 25X8 Aluminium Bus Bar for 3 phase connection of 4 Nos.
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard.
Earthing set complete with G.I. wire.
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
Stay set complete with stay wire and insulator clamp etc.
Bolts & Nuts with washer
Pole Muffing
Sundaries,Pole painting, Danger plate, Number Plate etc.
11 kV MVCC (Medium Voltage Conductor Cover) (23 CKm)
AL 59 ACS (52.88 sq. mm.) Rabbit conductor covered
Tension clamp for 11kV
IPC (for connecting bare to CC)
IPC (for connecting CC to CC)
Insulated Cable Tie
Mid Span Joint
Description of Work / Item(s)
Erection Portion
11 KV Feeder (Reconductoring) (59.2 CKm)
Detailed Route survey for new lines and submission of route profile/alignment etc. all complete
Jungle clearance including tree cutting along the line including trimming, loaping, branching etc as required to maintain staturory electrical clearance as per the direction of Engineer-in-charge
Dismantling of existing infrastructure
Erection of Single Pole 9m including excavation in all kinds of soils, concreting of foundations as per approved drawing, painting of poles concreting of foundations as per approved drawing, painting of poles (including Pole muffing, Painting etc) complete as per Technical Specification
Erection of Double Pole 9m including excavation in all kinds of soils, concreting of foundations as per approved drawing, painting of poles (including Pole muffing, Painting etc) complete as per Technical Specification
Fitting & fixing of all line accessories like cross arms, channels, brackets, danger board, anticlimbing device (including supply of nuts&bolts,etc.) complete as per specification for Single Pole.
Fitting & fixing of all line accessories like cross arm, DP channels, DP cross brackets, all types of clamps,danger board, anticlimbing device etc. complete (including supply of nuts&bolts,GI through bolt,etc) as per specification for Double Pole Structure
Pipe Earthing including fixing of 1mtr long GI pipe in all kinds of soils complete as per approved drawing and Technical Specification 1set/location
Erection of stay set including stay pit excavation, concreting, stone/ earth filling, ramming, fixing of stay wire, insulator complete as per specification
Stringing of line (3 wires) including paying out and sagging of conductor, and mid point jointing of ACSR Rabbit conductor, installation of disc/ pin insulator alongwith all necessary hardwares and accessories as per Technical Specification.
Installation of Isolator with X-arm etc.
11 KV Feeder (Bifurcation) (165.7 CKm)
Detailed Route survey for new lines and submission of route profile/alignment etc. all complete
Jungle clearance including tree cutting along the line including trimming, loaping, branching etc as required to maintain staturory electrical clearance as per the direction of Engineer-in-charge
Erection of Single Pole 9m including excavation in all kinds of soils, concreting of foundations as per approved drawing, painting of poles concreting of foundations as per approved drawing, painting of poles (including Pole muffing, Painting etc) complete as per Technical Specification
Erection of Double Pole 9m including excavation in all kinds of soils, concreting of foundations as per approved drawing, painting of poles (including Pole muffing, Painting etc) complete as per Technical Specification
Fitting & fixing of all line accessories like cross arms, channels, brackets, danger board, anticlimbing device (including supply of nuts&bolts,etc.) complete as per specification for Single Pole.
Fitting & fixing of all line accessories like cross arm, DP channels, DP cross brackets, all types of clamps,danger board, anticlimbing device etc. complete (including supply of nuts&bolts,GI through bolt,etc) as per specification for Double Pole Structure
Pipe Earthing including fixing of 1mtr long GI pipe in all kinds of soils complete as per approved drawing and Technical Specification 1set/location
Erection of stay set including stay pit excavation, concreting, stone/ earth filling, ramming, fixing of stay wire, insulator complete as per specification
Stringing of line (3 wires) including paying out and sagging of conductor, and mid point jointing of ACSR Rabbit conductor, installation of disc/ pin insulator alongwith all necessary hardwares and accessories as per Technical Specification.
Installation of Isolator with X-arm etc.
AB Cable - replacement of LT bare conductors
AB Cable (3x95+1x70)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (167 CKm)
Detailed Route Survey, investigation including peg marking, profiling / alignment of route etc. complete as per Technical Specification
Dismantling of existing infrastructure
Erection of Single Pole including exacavation in all kinds of soils, muffing of Poles as per approved drawing, painting of poles (including supply of concreting materials and paints,etc) complete as per Technical Specification
Fixing of all line accessories like cross arm, channels, brackets, danger board, anticlimbing device etc. complete as per specification for Single pole.
Fixing of G.I. Earth Spike (1800 x 20 mm) with 6 SWG/8 SWG GI wire, all accessories for earthing complete.
Erection of stay set including stay pit excavation, concreting, stone/ earth filling, ramming, fixing of stay wire, insulator complete as per specification
Stringing of LT AB Cable (3x95+1x70 sq.mm.) including installation of clamps for attachment of ABC to pole and all accessories including Distribution Box, jointing and termination, danger plate, etc. complete in all respect as required as per Construction Standard
Tree cutting along the line including trimming, looping, branching etc. as required to maintain statutory electrical clearance as per the direction of Engineer-in-charge
AB Cable (3x70+1x50)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (246 CKm)
Detailed Route Survey, investigation including peg marking, profiling / alignment of route etc. complete as per Technical Specification
Dismantling of existing infrastructure
Erection of Single Pole including exacavation in all kinds of soils, muffing of Poles as per approved drawing, painting of poles (including supply of concreting materials and paints,etc) complete as per Technical Specification
Fixing of all line accessories like cross arm, channels, brackets, danger board, anticlimbing device etc. complete as per specification for Single pole.
Fixing of G.I. Earth Spike (1800 x 20 mm) with 6 SWG/8 SWG GI wire, all accessories for earthing complete.
Erection of stay set including stay pit excavation, concreting, stone/ earth filling, ramming, fixing of stay wire, insulator complete as per specification
Stringing of LT AB Cable (3x95+1x70 sq.mm.) including installation of clamps for attachment of ABC to pole and all accessories including Distribution Box, jointing and termination, danger plate, etc. complete in all respect as required as per Construction Standard
Tree cutting along the line including trimming, looping, branching etc. as required to maintain statutory electrical clearance as per the direction of Engineer-in-charge
AB Cable (3x50+1x35)Sq.mm and Steel Tubular pole (Horizontal Configuration) - Reconductoring (163 CKm)
Detailed Route Survey, investigation including peg marking, profiling / alignment of route etc. complete as per Technical Specification
Dismantling of existing infrastructure
Erection of Single Pole including exacavation in all kinds of soils, muffing of Poles as per approved drawing, painting of poles (including supply of concreting materials and paints,etc) complete as per Technical Specification
Fixing of all line accessories like cross arm, channels, brackets, danger board, anticlimbing device etc. complete as per specification for Single pole.
Fixing of G.I. Earth Spike (1800 x 20 mm) with 6 SWG/8 SWG GI wire, all accessories for earthing complete.
Erection of stay set including stay pit excavation, concreting, stone/ earth filling, ramming, fixing of stay wire, insulator complete as per specification
Stringing of LT AB Cable (3x95+1x70 sq.mm.) including installation of clamps for attachment of ABC to pole and all accessories including Distribution Box, jointing and termination, danger plate, etc. complete in all respect as required as per Construction Standard
Tree cutting along the line including trimming, looping, branching etc. as required to maintain statutory electrical clearance as per the direction of Engineer-in-charge
11 kV MVCC (Medium Voltage Conductor Cover) (23 CKm)
Detailed Route Survey, investigation including peg marking, profiling / alignment of route etc. complete as per Technical Specification
Dismantling of existing infrastructure
Stringing of line (3 wires) including paying out and sagging of conductor, and mid point jointing of AL 59 ACS (52.88 sq. mm.) Rabbit conductor covered, installation of tension clamp for 11 KV, IPC and insulated cable tie alongwith all necessary hardwares and accessories as per Technical Specification.
Description of Work / Item(s)
Supply Portion
Erection Portion
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid