Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.8 L+₹3.0 L (6.47%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹49.9 L+₹3.1 L (6.68%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹49.9 L+₹3.2 L (6.74%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹50.1 L+₹3.3 L (7.14%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Feb 2021, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT OF OLD UNSERVICEABLE PANEL BOARDS CABLES AND LED LUMINARIES AND ALLIED WORKS FOR SECTOR B AND REPAIR TO PLUMBING/ SANITARY FITTINGS FOOTPATH HARDSTANDING PLINTH PROTECTION DRAIN ETC IN SUBSTATION AT GMS UNDER GE I GOS
2021_MES_413852_1
8000/82/20-21/0983/E8
Open Tender
Civil Works
Item Rate
108 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
16 Feb 2021
18 Jan 2021
10 Feb 2021
18 Jan 2021
8 Feb 2021
1 Feb 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 20 mm bore of pipe complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
Making connection of PPR distrubtion bracnch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
Taking down bib tap / wash basin tap/ pillar tap/ stop cock/ mixture tap and refixing the same after repair and replacement of washer 15 mm bore size complete all as specified and directed. Note: spindle where required will be measured and paid separately
S&F in repairs brass spindle short body of 15 mm bore complete all as specified and directed
S&F in repairs brass spindle long body of 15 mm bore complete all as specified and directed
S&F in repairs bib taps cast copper alloy with crutch or butterfly handle fancy type, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore of pipe complete all as specified and directed.
S&F in repair Chromoium plated angle cock, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule, 15 mm bore complete all as specified and directed.
S&F in repairs Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore of pipe complete all as specified and directed.
S&F in repairs for 15mm bore of pipe pillar taps cast copper alloy, with capstan head chromium plated screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair PVC waste pipe for urinal/WHB etc all complete all as specified and directed.
S&F in repairs CP 32 mm bore dia waste coupling of (half or full threaded) etc complete all as specified and directed.
S&F in repairs Chromium plated grating doom 100 m dia fixed in floor in CM 1:3 complete all as specified and directed
S&F in repairs ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repairs PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S & F in repairs internal fitting (syphon) for low level flushing cistern complete all as specified and directed.
S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repairs sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed
M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
M&L for Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for 50 mm High density polyethelyene pipes (HDPE) of pressure rating 6kgf/sqcm laid in trenches complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for 50 mm thick cement concrete 1:2:4 type B-1 using 20 mm gradedstone aggregate as in path/hard standing surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for forming construction joints 50 mm x 10 mm wide filled with sealing compound Grade A complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L chequered tile of size 200 x 200 x 18 to 20mm set and jointed in neat cement slury and pointed in grey cement and pigments to match over 20mm thick screed bed in CM 1:6 complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT Bars 5 mm dia & over upto & including 10 mm dia in stirrups, spaces & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified & as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed
M&L preparation of new or previously untreated steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and as directed.
M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed
M&L for complete removal of existing treatment on walls and applying two coats of cement based paint complete all as specified and directed
M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed
M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L preparation of old painted surfaces of walls and applying one coat of cement based complete all as specified and directed.
M&L preparation of old painted surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L preparation of old painted surfaces and applying one coat of anti fungal weather coat paint on walls complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed
Demolition of existing sunken water proofing treatment/cement plaster/cement concrete any descripltion and removing the debris from site n exc 150 m from site complete all as specified and directed.
M & L for rendering 10 mm thick CM 1:3 surface as in roof with 3% integral water proofing compound by the weight of cement complete all as specified and directed
Supply only cement concrete type B1 1:2:4 (20 mm graded agg) as in padding concrete/coving for in Jn of sunken floor and vertical wall or to maintain proper slope on roof chamfored on edge complete all as specified and directed.
Supply, fabricate, erect, test and commission in replacement outdoor LT SMC Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, made out of box 2 mm thick, 3 phase, 4 wire, 440 volt , AC, 50 HZ , factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricted by combining SMC and pultruded FRP Sections , rust proof, shock proof to with coastal polluted atmosphere, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete (Sintex/Hensel) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators complete all as specified
Supply, laying and testing in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core including cable lux complete all as specified and as directed Make : KEI/Havells/Gloster/Polycab
Supply, laying and testing in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including cable lux complete all as specified and as directed Make : KEI/Havells/Gloster/Polycab
Supply, laying and testing in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm x 2.0 core including cable lux complete all as specified and as directed Make : KEI/Havells/Gloster/Polycab
Supply, laying and testing in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm x 4.0 core including cable lux complete all as specified and as directed Make : KEI/Havells/Gloster/Polycab
Supply, laying and testing in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core including cable lux complete all as specified and as directed Make : KEI/Havells/Gloster/Polycab
Supply and fix street light fitting LED type of 72 watt New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic dirver complete all as specified and as directed.Make : Surya/Havells/C&S
Supply and fix street light fitting LED type of 60 watt New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic dirver complete all as specified and as directed.Make : Surya/Havells/C&S
Supply and fix street light fitting LED type of 45 watt New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic dirver complete all as specified and as directed.Make : Surya/Havells/C&S
Supply and fix street light fitting LED type of 30 watt New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic dirver complete all as specified and as directed.Make : Surya/Havells/C&S
M&L in replacement of LED flood lights of cap 120 W cap D-clamp fitting of powder coatedpressure die cast aluminium High power LED with heat resistant toughed glass with connected accessories complete all as specifed and as directed. Make : Surya/Havells/C&S
Supply and fix post-top lantern 40 watt energy saving, environmental friendly, long life aesthetically designed with IP 66 symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Make : Surya/Havells/C&S
Supply and fix post-top lantern 30 watt energy saving, environmental friendly, long life aesthetically designed with IP 66 symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Make : Surya/Havells/C&S
Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting digital timer 24 hour set up with contactor rating65 Amps TP of max load 12 KW complete with fixing arrangemetns on MS Channel of suitable size and necessary PCC Wk all as specified and as directed by Engr-n-charge
M&L for taking down the motorised / manual High Mast Lights circular grid accomodating MH/MV/LED light fittings any cap over a ht of 15 mtr to the ground, taking aside, replacing the unsv control gears/ light fittings with LED fixtures and raising back to its original position upto 15 mtr etc complete all as specified and as directed (Rates quoted shall be incl of replacing required accessories where specifically not mentioned but required to complete the Job except LED fixtures)
S & F in replacement of direct type LED retrofit lamp in street light fittings 30 watt 2500 lumen output, 6500 K colour temp complete all as specified and directed by Engineer-In-Charge Make : C&S / Havells/ HPL/ Sysca
S&F in replacement Anologue electro mechanical timer 24 hrs minimum setting 30 minutes for daily working contact rating 16 Amps, 240 Volts, AC with initial charging, battery backup having supply reserve failure Make : C&S / Havells/ HPL/ Sysca
Supply and fix in replacement of automatic modular contactor with manual override , 40 Amps 3P 50HZ suitable for timer switch of street light complete all as specified and directed Make : C&S / Havells/ HPL/ Sysca
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm Outdoor type complete all as specified and as directed (Make 3M, REYCHEM, M-seal)
All as per item NO.103 above but of size 70 to 150 Sqmm complete all as specified and directed.
All as per item No. 103 above but of size 185 to 300 Sqmm complete all as specified and directed.
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 400 amps 50 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 315 amps 36 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 250 amps 36 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 3 pole 415 volts of capacity 250 amps 36 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 200 amps 36 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 3 pole 415 volts of capacity 200 amps 36 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 3 pole 415 volts of capacity 160 amps 25 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 100 amps 25 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 3 pole 415 volts of capacity 100 amps 25 KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 4 pole 415 volts of capacity 63 amps 25KA all as specified and directed. Make : HPL/ C&S/ Havells
Supply and fixing in replacement MCCB Adjustable type 3 pole 415 volts of capacity 63 amps 25KA all as specified and directed. Make : HPL/ C&S/ Havells
Dismantling the unserviceable changeover switch and Supply and fix ON- LOAD change over switch advance neutral front handle with elclosure, operated panel mounting type 415 V 50 Hz, confirm to IS :13947-3, of cap 100 Amps in the existing panel. MAKE: L&T/Havells/HPL
Dismantling the unserviceable changeover switch and Supply and fix ON- LOAD change over switch advance neutral front handle with elclosure, operated panel mounting type 415 V 50 Hz, confirm to IS :13947-3, of cap 400 Amps in the existing panel. MAKE: L&T/Havells/HPL
Excavation in treanches not exceeding 1.5 MM wide and not exceeding 1.5M deep for toundation/Cable trench not exceeding 10 Sq mm on plan and getting out in soft /loose soil complete all as specified and directed.
Returning filling including spreading leveling and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Supply and fix Double wall corrugated HDPE pipe 50 mm outer dia for protection of UG cable complete all as specified and directed.
Supply and fix Double wall corrugated HDPE pipe 100 mm outer dia for protection of UG cable complete all as specified and directed.
Boring across the road/hard surface horizontally with machanical boring equipments not less than 80 mm bore complete all as specified and directed.
M&L for painting of LT steel tubular pole swaged/steel /Swan neck poles of 9/11 mtr height with and including cross arms, MS clamps nuts, bolts, height from 1.5 mtr from coping to top of pole including preparation of iron surface and applying with single coat of aluminium paint on existing surface complete all as specified and directed.
M&L for painting of LT pole PCC/RCC poles of 9 mtr height with and including cross arms, MS clamps nuts, bolts, height from 1.5 mtr from coping to top of pole including preparation of iron surface and applying with single coat of aluminium paint on existing surface complete all as specified and directed.
M&L for writing of numbers and words (not more than 10 characters) on existing steel / PCC poles with synthetic enamelled paint of any size in 30 cm wide strips alternatively black and white on existing surface including white washing on PCC coping of poles complete all as specified and directed.
Preparing external/internal surfaces of the panel boards/Feeder pillar boxes , consoles etc by scrubbing /CTC by emary paper by removing stains/rusted scales etc and applying two coats of synthetic enamel paint complete and cleaning the carbon in cables meters/indicators etc complete all as specified and directed.
Surface dressing n.exc 30 cm deep and average 15 cm deep and getting out in any type of soil around the timer/ elect panel bds complete all as specified and directed.
Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed for following sizes :- (a) 40 mm bore
(b) 50 mm bore
(c) 80 mm bore
M/s MAA BHAIRABI ENTERPRISES
M/s TECH TEAM
M/S. KISHAN ENGINEERING
ABC CONSTRUCTION COMPANY
R K Traders
V.Venkata Ramaiah
M/s Bapujee Builders and Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .