Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | ₹39.7 L | L1 | Accepted-AOC L1 bidder lowest |
| 2 | L2₹43.8 LRejected-Finance H NO HDLX 31 DHANWANTRI NAGAR BESIDE JASUJA CITY JABALPUR MP 482003 | JABALPUR | MADHYA PRADESH | 482003 | ₹43.8 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹68.0 LRejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | ₹68.0 L | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | RAVINDRA ELECTRICAL L1 | ANAMIKA CONSTRUCTION L2 | SHRI KRISHNA CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, testing and commissioning of Solar Water Heater (Flat plate collector type) duly integrated with electric water heater (if system is not energied by solar due to non availability of Sunny day, system will run automatically through electricity) to be placed on building roof at suitable height of capacity of 1000 LPD indirect Heating with Heat exchanger SS 304 with selectively coated "A' size Solar Flat Plate Collector made of aluminium body with toughened glass insulated hot water tank inter connection circulation piping between the system, collectors and hot water tank stand & temp gauge etc. Solar Collector for 1000 LPD for installation of Solar water heater with the following specification as per IS: 12933 (Part-I)-1992 | 4 | Each Job | 3,50,000 ₹14,00,000 | 2,80,000 ₹11,20,000 | 5,00,000 ₹20,00,000 |
| 2.00NOTES :- (a) Solar Flat plate collector having ISI Marked outer nominal dimension of 1860mm x 1240mm x 110mm. (b) Material : aluminium cast type channel and angle. (c) Back covering 24 SWG aluminum sheet and upper covering not less than 3.2mm thick tamper/toughened glass absorber selectively coated copper fin and tubes nominal fins, insulation 50mm thick mineral wool of 48 kg/cum density & reflector, 48 gauge aluminium foil. (d) Gasket EPDM/SPDM/Neoprene flange 62mm ODSX 1320mm length. (e) 01 No cover plate shall be toughened glass confirming to IS 12933 (P). (f) Solar Hot Water Tank capacity 1000 Ltr made of 2.0mm SS 304 with 50mm puf insulation. (g) Including neccessary structure and finishing work, foundations, Electrical connection and other safety devices such as thermostat relay etc complete all as specified and directed by Engr-in-Charge. Make:- Supreme Solar/Tata Solar/Venus. Note: (i) Rate quoted by contractor shall be deemed to be included for 2 years comprehensive maintenance and 2 year replacement warranty after successful completion of work. Nothing extra will be paid in this regard. (i) Cable for electrical connection, hot and cold water pipe shall be measured and paid seperately under respective items. | ||||||
| 3.00 | S & F Rotational moulded Polythene [HDPE] Water Tanks, Cylindrical & Vertical Type 2000 Liters Capacity hoisted and fixed in position including provision of 40mm/25mm/20mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. | 4 | Each | 18,000 ₹72,000 | 15,000 ₹60,000 | 30,000 ₹1,20,000 |
| 4.00 | S&F 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 of 20 mm dia (PN16) UV stabilízed and antimicrobial fusion welded having thermal stability for hot & cold water supply including alI PP-R plain & brass threaded polypropylene random fitings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed. | 100 | RM | 90 ₹9,000 | 120 ₹12,000 | 300 ₹30,000 |
| 5.00 | Supply and laying of Gl steel tubing 50 mm bore medium grade laid in trenches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps complete all as specified and directed. | 200 | RM | 850 ₹1,70,000 | 580 ₹1,16,000 | 300 ₹60,000 |
| 6.00 | All as per described in serial item No 5 above, but bore 25 mm | 150 | RM | 300 ₹45,000 | 280 ₹42,000 | 300 ₹45,000 |
| 7.00 | All as per described in serial item No 5 above, but bore 20 mm | 200 | RM | 280 ₹56,000 | 200 ₹40,000 | 300 ₹60,000 |
| 8.00 | All as per described in serial item No 5 above, but bore 15 mm | 150 | RM | 230 ₹34,500 | 160 ₹24,000 | 300 ₹45,000 |
| 9.00 | M&L Gun metal globe / gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specefied and directed. | 4 | Each | 650 ₹2,600 | 2,950 ₹11,800 | 500 ₹2,000 |
| 10.00 | M&L Gun metal globe / gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 25mm bore dia steel tubing complete all as specefied and directed. | 12 | Each | 750 ₹9,000 | 1,200 ₹14,400 | 500 ₹6,000 |
Updated dates
Tender Value
₹47.9 L
EMD Value
₹95,860
Closing Date
3 Feb 2026, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF 04 X SOLAR WATER HEATER (1000 LTR) FOR BLDG NO P-320 AND P-534 (OR LIVING BK) OF 2 TTR, 1STC AND CERTAIN REV AND MINOR WORKS IN AOR OF AGE B/R-III, AGE E/M E/S AND AGE E/M W/S UNDER GE (WEST) JABALPUR
2026_MES_747273_1
8893/E8
Open Tender
Civil Works
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (West) Jabalpur
₹95,860
25 Jun 2026
5 Jan 2026
10 Feb 2026
6 Jan 2026
3 Feb 2026
19 Jan 2026
6 Jan 2026 - 14 Jan 2026
S & F Rotational moulded Polythene [HDPE] Water Tanks, Cylindrical & Vertical Type 2000 Liters Capacity hoisted and fixed in position including provision of 40mm/25mm/20mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S&F 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 of 20 mm dia (PN16) UV stabilízed and antimicrobial fusion welded having thermal stability for hot & cold water supply including alI PP-R plain & brass threaded polypropylene random fitings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
Supply and laying of Gl steel tubing 50 mm bore medium grade laid in trenches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps complete all as specified and directed.
All as per described in serial item No 5 above, but bore 25 mm
All as per described in serial item No 5 above, but bore 20 mm
All as per described in serial item No 5 above, but bore 15 mm
M&L Gun metal globe / gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specefied and directed.
M&L Gun metal globe / gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 25mm bore dia steel tubing complete all as specefied and directed.
M & L for construction of new Valve Chamber of brick masonry of size 900 mm X 900 mm X 900 mm [Internal Dimensions] with 150 mm thick, PCC 1:4:8, Type D-2 for foundation, brick work using sub class "B" bricks of one brick thick wall in cement mortar 1:4 including internal plastering 15mm thick in CM 1:4, external plaster 15mm thick in CM 1:4 and providing coping in PCC 1:2:4, Type B-1 and 6mm thick MS plate cover with 50 X 50 X 6 mm MS angle iron frame, 25 X 6 mm flat iron hold fasts, complete including handle and locking arrangement etc and providing two coats of anti corrosive paint over one coat of red oxide primer to MS surfaces including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
S & F Ball Valves, 20 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe [Minimum Weight 20mm - 210 Grams] etc complete all as specified and as directed.
S&F 20 mm bore, Bib tap, CP with crutch/butterfly handle screwed, high pressure, screwed for iron pipe, complete all as specified and directed.
S & F Stop Valves, 20 mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle for iron pipe etc complete all as specified and as directed.
S& F Sheet metal enclosure DBs Single Pole and Neutral 4 way with 200 Amps rated bus bar 240 volts double door complete all as specified and directed.
S&F MCB SPN 240 Volts 'C series Breaking capacity 10 KA of rating 32 Amps complete all as specified and as directed.
M & L for sub main wiring with 2 runs of single core 4 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Copper Multistranded Conductor, 1100 Volts Grade, ISI Marked, drawing through and including PVC Heavy Duty Conduit, 20 mm dia including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Copper Multistranded Conductor, 1100 Volts Grade earth continuity conductor complete all as specified and as directed. Note: 2 runs of 4 Sq.mm & 1 run of 4 Sq.mm and one run of 20 mm dia PVC Conduit will be measured as one unit.
Supply, laying and testing LT cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core. Note:- The rate quoted by the contractor is deemed to be included for provision of necessary suitable lugs for connecting UG cable.
S&F DWC Pipe lS-16205, size outer dia 50 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, or for laying cables intrenches etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in soft loose soil etc complete all as specified and directed.
Returning, filing in, excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed
Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the stating points etc complete all as specified and directed
M&L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
M&L for earthing complete with galvanízed steel earth plate electrode 600 x 600 x 6 mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised wire of size 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for prołection of earthing strip. watering pipe 20mm bore Gl medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, Coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm CIC both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-l (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Material and labour for cutting, drilling and taping cast iron / ductile iron water mains (in position) for branch connection of existing pipe line of any size including necessary fittings such as ferrules, nipple short pipe etc complete all as specified and directed.
M & L for Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 1.5 wide and 1.5m in depth and getting out all as directed including filing back and finishing it with PCC complete matching with the surroundings.
Supply, fix, commissioning and testing of Water Softning Plant of capacity 0.5 cum/hour complete all as specified and directed. Make:- Eureka Forbes or other equivalent make approved by GE. As per following techical specifications:- WTP System Capacity (LPH) -500 1. Raw Water Tank - Overground Quantity -01 No 5000 litre 2. Feeder Pump - Flooded suction, Quantitiy -01 No, Type - Horizontal Centrifugal, Flow - 500 LPH, Head - 35m, MOC -CI 3. Dual Media Filter - Quantitiy - 1 No, Operating capacity -500 LPH, Vessel size - 8" x 44" , MOC of Vessel - FRP, Media - Anthracite + Support Bed, Type of valve - Auto Multiport, Frontal Piping- UPVC Sch. 40, 4. Iron Removal Filter - Quantity - 1 No, Operating Capacity - 500 LPH, Vessel Size - 8" x 44" , MOC of Vessel - FRP, Media- Resin+Support Bed, Type of valve - Auto Multiport, Front Piping - UPVC Sch. 40. 5. Water Softener - Quantity -01 No, Capacity- 500 LPH, Size- 8" x 44", Type of valve- Auto Multiport, MOC of Vessel- FRP, Resign Quantitiy- 30 Lit, Operational Hour- 10 Hours per day, OBR- 5 m3, Regeneration- After 5 m3 i.e. after 7 days, Regeneration Chemical/per regn/day- 6 Kg, Regeneration Tank Capacity- 1 No. 60 Lit, MOC of Tank- LLDPE, Capacity of tank- To store 1 regeneration Solution of OBR 5m3 , Frontal Piping- UPVC Sch 40
6. Instrumentation pressure gauges Range-0-7 kg/Cm2, Quantitiy- 01 Set, Flow Indicators-Type-Float Type, Panel Mounted, Quantity-01 , No., Location-Feed, MOC- Polycarbonate with SS Float, Level Switch- Qty 02 Nos, Type- Floaty, Location- Raw water tank & Product Water tank, Hardness Test Kit-01 No. 7. Box Type Skid - 01 Set, MS Painted 8. Electrical Panel-01 Lot, Cabling- 01 Lot 9. ICPW- Quantity-01 Lot, MOC- UPVC Sch 40. UPVC Sch 40 - From inlet flange of feed pump to outlet flange of Softener system (Max distance 1 m) NOTE: Rotational moulded polythene (HDPE) water tanks of 5000 Ltrs capacity will be measured and paid separately under respective items here-in-after.
Supply only Rotational moulded Polythene [HDPE] Water Tanks, Cylindrical, Vertical Type and three layers 5000 Liters Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
Supply and laying of GI steel tubing 40 mm bore medium grade, laid in trenches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps complete all as specified and directed.
Material and labour for cutting, drilling and taping cast iron/ Ductile iron water mains (in position) for branch connection of the internal dia 80 to 200 mm including necessary fittings such as ferrules, nipple short pipe etc complete all as specified and directed.
M & L Gun metal globe / gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 40 mm bore dia steel tubing complete all as specefied and directed.
M & L for sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Copper Multistranded Conductor, 1100 Volts Grade, ISI Marked, drawing through and including PVC Heavy Duty Conduit, 20 mm dia including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Copper Multistranded Conductor, 1100 Volts Grade earth continuity conductor complete all as specified and as directed. Note: 2 runs of 2.5 Sq.mm & 1 run of 2.5 Sq.mm and one run of 20 mm dia PVC Conduit will be measured as one unit.
S & F Ball Valves, 40 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe [Minimum Weight 40mm - 690 Grams] etc complete all as specified and as directed.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one single pole MCB of 20 A complete all as specified and directed
S & F sheet metal enclosure factory made double door DB, 240 volts with 200 Amps rated bus bar SPN 4 Way complete all as specified and as directed.
S & F complete for MCB SPN 6-32 Amps 415 volts, C Curve, 50 Hz AC supply complete all as specified & directed.
M & L excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in soft/loose, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
S&F rolled section as in man and cross beam, hip and jack rafters, purlin where connected to common rafters and running rails and guides for sliding doors; fixed for sliding; fixed with angle cleats or other connecting plates complete all as specified and directed.
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E-165)complete all as specified and directed.
S & F mild steel bolts exc 20 & n.exc 25 mm dia, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
S& F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or grith and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of of steel of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed..
Taking down cement plaster / terrazzo of any description thickness including raking out joints hacking for key scrubbing down with water complete all specified and directed.
Dismantaling floor hearth or wall tiling/china moisac including cement mortar bedding (but not backing), rubbish off the premises, complete all as specified and directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ brick, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over and including 1 mm thick wall care putty on wall plastered surface including one coat of alkali resistant primer complete all as specified and as directed.
M&L for complete removal of existing treatment distempered and painted surfaces incl preparation of old undecorated surface of walls and applying two coats of oil bound distempered over 1 mm thick wall care putty on wall over one coat of alkali resistant primer complete all as specified and directed
Demolition of cement concrete in ground floors and paving not exc 15cm thickness (below or above ground level) all as specified including removal of debries outside MD land complete all as specified and directed.
M & L for 20 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M&L for vitrified double charge tiles 8 to 8.5 mm thick (Square or rectangular) area of Each tile 0.36 Sqm but not exceeding 1.44 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed..
M&L for Granite (of any type ) 20 mm thick work (table rubbed and polished) as in steps, jambs, pilllars, window cill, cooking platforms and like, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of Granite laid over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for rounding to edges of granite stone slabs one edge etc. to the entire satisfaction of Engineer-in-Charge.
Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area not exc 1.5 Sqm Each complete all as specified and directed.
Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area exc 1.5 Sqm but n.exc 4 sqm Each complete all as specified and directed.
Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 62x67 mm(tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer complete all as specified and directed.
Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proof S.S. wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) comprising of uPVC chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 + 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I Fastener 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F, Aluminium powder coated for doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed.
S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified.
S&F 5.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified and directed.
S&F 5.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in Each pane complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
S & F 5 mm Prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. on frame complete all as specified and as directed.
S & F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing on MS frame complete all as specified and as directed.
S & F in repairs for stainless steel 20 mm dia curtain rod fancy type with S/S finials/side brackets (both side) as approved complete all as specified and as directed.
M&L for Cutting holes in brick walls in exc half brick and nexc one brick in cement in mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed. NOTE : Punned thickness only shall be measured and paid.
Supply and laying the Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Supply, laying or fixing or passing through pipe commissioning and testing of XLPE insulated, amoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out dismanting of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & Gl pipe where required shall be measured & paid separately under
(a) 70 Sqmm 3.5 Core
(b) 120 Sqmm 3.5 Core
Supply, erection, commissioning and testing outdoor type LT Panel, platform mounted., suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 1000 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade: RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS: 13947. The LT Panel shall be made of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) ogering ted and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBS shall be malked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismanting of old unserviceable LT Panel complete and including the folowings:- CONTROL WIRING: All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type Copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges and crimped with suitable size and tupe of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoinig Cable 5O kA terminals shall be provided for conecting of all incoming and outgoing cables. INCOMING- MCCB 630 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, electronic release
OUTGOING: (a) MCCB 250 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, thermal magnetic release, lc= 100%lcu 02 Nos (b) MCCB 200 Amps , 4 pole, 415 volts, 25 KA,50 Hz thermal magnetic release, lcs = 100%lcu, - 02 Nos (c) MCCB 160 Amps, 4 pole, 415 volts 25 KA, 50 Hz, themal magnetic release, lcs = 100%lcu -02 No. (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accurancy class 1%-01 No (e) Digital Ammeter 96mm x 96mm Suitable to read 0 to 630 Amps, accuracy class 1% - 01 No. (f) Current transfomer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red- 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos) (j) Copper bus bar 20mm wide, 5mm thick of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs-04 Nos. |(k) LED Pilot Lamp of following colours: ( RED -01 No, YELLOW - 01 No, BLUE - 01 No,. (l) 02 Nos.Danger Notice Plate duly writtern in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 15Ommx10Omm shall be fxed on both front & rear door of the bus bar charnber. (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Lagrand -01 No (n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 No (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area). Note : Panel will be manufactured by CPRI approved firrm. The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be incduded in the quoted rates.
M&L for GI Tubes in repair of following size, medium grade ,galvanised, with clamp of 25x3 flat iron welded to pipe fxed to wall/polelceiling or laid in floors or under road etc complete all as specified and as directed.
50 mm bore
80 mm bore
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8893SPPS.pdf
Tender Documents • 1.25 MB
BOQ_836810.xls
BOQ • 0.36 MB
8893GP.pdf
Tender Documents • 0.44 MB
SCH8893.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid