| 1 | L1₹33.7 LAccepted-AOC | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹36.5 L+₹1.6 L (4.70%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹37.3 L+₹2.4 L (6.91%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹38.7 L+₹3.8 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹39.0 L+₹4.1 L (11.7%)Rejected-Finance AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
2 Jul 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
SPECIAL REPAIR QTR NO P-10/1 AND P-10/2 AT PONAPPA ROAD ALONG WITH CERTAIN WORKS AT NEW CANTT ALLAHABAD
2022_MES_528616_1
8547/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹96,000
Yes
20 Jul 2022
4 Jun 2022
4 Jul 2022
4 Jun 2022
2 Jul 2022
18 Jun 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for first or premium quality glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including screed bed 10mm thick in cement mortar 1:4 finished rough to receive wall tiles etc complete all as spd and directed.
M & L for first or premium qualityNon - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for first or premium qualityVitrified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles n.exc 0.36sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for first or premium qualityVitrified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles n.exc 0.36sqm , in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
S&F first or premium quality exterior finish designer pavement tiles, coloured, superior quality, 300x300x10mm thick as in floors/ pavement etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete.
M & L for E-board tiles ceiling on GI powder coated channel/Tee/Grid of make (Armstrong or equivalent) frame work with the following specification including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type BO/Cement mortar 1:3 complete all as specified and directed with following:- (a) M & L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of make (Armstrong or equivalent) of size 25 x 25 mm x 0.5mm (b) S & F 1.6mm dia GI wire suspenders with adjustable clamps and dash free fastners with rawl plug and screws plugging in RCC slab placed @ 605mm centre to centre from perimeter of wall. (c) S & F 25x25x0.5mm thick GI tee powder coated as main and cross members at 595 mm centre to centre supported suspenders along with adjustable clamp to maintain level. (d) S & F 4mm thick E-boards of approved texure and finished ceiling tiles of size 595 mm x 595 mm , confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of tiles shall be as approved by GE
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing with solvent on to wall to make PVC frame as per specifications complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc1.5 but n. exc 4 Sqm each.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n exc1.5 Sqm each.
S&F 2nd class HW plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete.
S&F factory made 30 mm thick flush shutter solid core construction with block board core & plywood face panels commercial type on both sides incl 5mm thick teakwood leaping alround complete all as specified & directed.
S & F Solid PVC moulded door frame of size 50mm x 47 mm made out of 5 mm thick single side prelam PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F factory made Solid PVC moulded door shutters 28 to 30 mm thick (stiles) with particle board core, with 2, raised panel design with 2 mm thick moulded Prelam on front face and 2 mm thick prelam PVC sheet on back side completed all aspecifed and directed.
S&F 30 mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed.
S&F 30 mm thick second class hardwood glazed and Skelton factory made window shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed.
M&L for preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
M&L for preparation of old painted surface of steel and iron of any discription, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed.
S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F in repair mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F 4 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area exc.n 0.5 Sqm in each pane complete.
S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed
S&F MS Butt hinges medium wt cold rolled of size 100 mm.
S&F MS Butt hinges medium wt cold rolled of size 75 mm.
S&F 100mm long Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge , pin anodized complete all as specified and directed.
S & F aluminium bow handle,cast type,anodised 150mm long complete fixed with steel screws complete all as specified and directed.
S&F Aluminium sliding door bolts plate type stove enamelled black with bright bolt not less than 12mm dia with & including a min of 6 bolts & nuts four on bolt plate & two on staple plate & fixed 300 mm long complete all as specified and directed.
S & F in repair Stainless steel plate rack (utensil rack) of size 900 mm x 750 mmx250mm made with 0.63 mm thick stainless steel sheet provided with brass screw including necessary fittings, nut/bolts complete all as specified and directed.
Supply and fix/fabrication in repair kitchen cabinet & wardrobe/ cupboard made out of 16 to 18 mm thick PVC board plain sheet including fixing of cabinet for keeping baskets/ cutlery basket complete.Make : Rajshree or equivalent all as specified and approved by Accepting Officer.
Supply and fix/fabrication in repair kitchen cabinet & wardrobe/ cupboard made out of 16 to 18 mm thick PVC board laminated sheet complete.Make : Rajshree or equivalent all as specified and approved by Accepting Officer.
Supply only stainless steel acessories suitable for kitchen cabinets as under:-
(a) Stainless steel basket (plain) of size 50cmx37cmx10cm made of 4mm th S.S.wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18'/20' inch length two way extruded MS galvanised over rollers of approved make Make: Life style Cat part No WA/POB/15204 or equivalent approved
(b) Stainless steel thali basket (11-13 division) of size 50cmx37cmx20cm made of 4mm th S.S.wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/20 inch length two way extruded MS galvanised over rollers of approved Make: Life style Cat part No WA/TB/15208 or equivalent approved
(c) Stainless steel Plate basket (11-13 division) of size 50cmx37cmx16cm made of 4mm th S.S.wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/20 inch length two way extruded MS galvanised over rollers of approved Make: Life style Cat part No WA/PTH/15206 or equivalent approved
(d) Stainless steel Cutlary basket of size 50cmx37cmx10cm made of 4mm th S.S.wire and bottom of S S perforated sheet approved quality with suitable arrangement for fixing Telescope basket (channel) 18/20 inch length two way extruded MS galvanised over rollers of approvedMake: Life style Cat part No WA/CUT/15204 or equivalent approved
(e) Stainless steel basket (plain) of size 50cmx37cmx16cm made of 4mm th S.S.wire approved quality with suitable arrangement for fixing Telescope basket (channel) 18/20 inch length two way extruded MS galvanised over rollers of approved Make: Life style Cat part No WA/POB/15206 or equivalent approved
S&F continues (piano) hinges, mild steel, bright finish width of flap (when open) 30mm complete.
S&F magnetic catches with steel body ‘H’ type, fixed to shutter complete.
S & F 100 mm dia brass handle cast type polished bright finish complete
S & F 150 mm dia brass handle cast type polished bright finish complete
Taking down door shutters of any description exc 1 Sqm & n.exc 2 Sqm each and refixing in the same opening after easing and adjusting complete all as specified and directed
Demolition Stone slabs and tiles of any description or thickness in floors,laid bedded and pointed in cement mortar aprons etc complete all as specified and directed.
M&L 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like incl moulding the edges etc, and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed.
M&L for mild steel hollow sections conforming to Fe-410 W (Gde E-250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfacesand applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces , over 10 cm in width or grith not other wise described complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges complete.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for providing 100mm thick, PCC 1:2:4 type B-2 (using 40mm graded stone aggregate ) as in floors, pavings etc complete all as specified and directed.
Demolition of brick work built in cement mortar and removing rubbish complete
M & L Brick work with fly Ash old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete.
S&F rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity(Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMT float valve epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
M& L for Disconnecting existing tanks, capacity exc 250 & n exc 500litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. complete.
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as spd and directed.
Taking up or down 20 mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as spd and directed.
M&L for 15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
M&L for 20mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Refixing old steel tubing and connection in new or old position in wall/ceiling/floor etc bore of pipe 15mm dia with new fittings complete all as specified and directed.
Refixing old steel tubing and connection in new or old position in wall/ceiling/floor etc bore of pipe 20 mm dia with new fittings complete all as specified and directed.
S & F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete.
Cutting chases pinning in making good to facing where required for concealed water tubing and similar work and making good cutting not exc 10cm girth in brick walls complete.
Demolition and breaking up (salt glazed ware, AC, PVC) drain pipes of any dia set in cement mortar complete.
S & F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore complete.
S & F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore complete.
S&F PVC (SWR) Bend 75mm dia complete all as specified and directed.
S&F PVC (SWR) Bend 110mm dia complete all as specified and directed.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of cement base paint complete all as specified
M&L for preparation of old painted surface of wall including cornices etc. by washing, rubbing down and stopping of distempered and painting surfaces, and applying two coats of cement base paint of approved shade on old surface of wall complete all as specified and directed.
Dismantling of bricks (laid flat or on edge ) or brick tiles in floors, channels, kerbs aprons etc
Removing of surplus excavated/demolised materilas to a distance n.exc 50m and deposited where directed at a level n. exc 1.5 m above the starting point.
M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof padding, in leveling course, benching, mud stops etc, complete all as specified and directed
M&L for water proofing treatment on roof slab consisting with following operation:- (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brushes and dusting (ii) Applying a layer of bitumen primer conforming to IS 3384 @ 0.4Ltr/sqm on the surface. (iii) M&L for applying a coat of hot blown bitumen grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed (iv) Laying 3mm thick APP membrane having non-woven polyster matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm i.e overlap & 150mm end overlap, sealing all overlaps complete including treatment at all junctions & corners. The membrane shall be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor. (v) The Membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcious, Flow resistance > 120 degree celcious dimensional stability, <0.5% when fested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers".
M&L for 10 mm thick Cement plaster in CM 1:4 on roof surfaces mixed with WPC complete all as specified and dierected. Note : WPC shall be measured and paid separately
M&L cutting crack to V- section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry of 1:3 complete all as specified and directed.
Supply only integral water proofing compound
M&L 40 mm thck brick tiles laid on water proofing membranes and jonted flush pointed in CM 1:3 with 5% of crude oil incl bedding in CM 1:6, 15 mm thick complete all as specified and directed
M&L for old brick tiles (obtained from dismantling), laid on water proofing membranes and jonted flush pointed in CM 1:3 with 5% of crude oil incl bedding in CM 1:6, 15 mm thick complete all as specified and directed
M&L for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate in roof kerbs or mud stops rounded or chamfered on edges etc complete all as specified and directed.
S&F in repair 15mm bore, CP Bib taps fancy type long body , half / full turn , screwed down for iron pipes complete all as specified and directed or as approved by Engr-in-Charge.
S&F in repair for wall mixer with connecting legs and wall flanges with provision for overhead shower with 115 mm 15mm dia chromium plated brass and securing to walls complete.
S&F 15mm dia Brass CP mixter for mixing hot & cold fancy type screwed down ,high pressure long screwed shanks and fly nuts , screwed for iron pipe complete all as spd and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed
S & F in repairs shower CP fancy type 100 mm including shower arms complete all as specified and directed.
S&F in repair PVC mirror cabinet, coloured of size 300 x 450 mm fixed with screw and PVC gutty on wall complete all as specified and directed. Make:Prayag or equivallent as approved.
S&F in repair brass chromium plated towel rail 20mm dia D type, 60cm long between flanges fixed with screw to wall complete
S&F in repair vitrious china soap disk fixed to plugs with chromium plated brass screws complete
M & L in repair 15mm angle valves/ stop cock, fancy type, chromium plated , cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair, two way angle valve chromium plated, brass 15mm bore complete all as specified and directed.
S&F in repair CP toilet paper holder fixed to walls with chromium plate brass screws complete
S&F Health foucet including PVC pipe 1.20m long with brass nuts for EWC, fixed in repairs complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white including connection in drain and in flushing pipe complete including 'P' or 'S' trap and plastic water closet seat cover complete.
S&F, in repair PVC Flushing cistern 10 ltr capacity with inlet ball valve float and handle and 32mm bore flush pipe including bracket complete all as specified and directed.
S & F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed.
S & F in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed.
S & F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S & F in repair Stainless steel plate rack (utensil rack) of size 900 mm x 750 mmx250mm made with 0.63 mm thick stainless steel sheet provided with brass screw including necessary fittings, nut/bolts complete all as specified and directed.
S&F in repair Brass chromium plated bottle traps 32mm for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on other fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete
Material & labour for preparation of new plastered surfaces of wall and applying two coats of Oil bound distemper over a coat of 1mm thick wall care putty complete .
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete.
M&L for complete removal of existing finishes of wall including cornices etc by scraping out, washing, rubbing down and stopping of existing plastered or unplastered surfaces surfaces and applying Two coats of oil emulsion distemper white or tinted of approved shade over a coat of white cement based putty 1-2 mm thick complete all as specified and directed.
M&L for preparing plastered or unplastered old decorated surfaces of wall including cornices etc by brooming down or steel wire brushing ,scrapping down smoke shoot, moulds, mos and efflorescent salts and trading oil and greasy spots,removal of vegetation and applying Two coats of white wash on wall surfaces complete all as specified and directed.
M&L for Preparing old plastered or unplastered surfaces of ceiling and applying one coats of white wash complete.
M&L for mild steel framed work such as grill ,gates, guard bar, framed with welding using angle iron, square bars and round bars section etc including cutting, welding, revetting complete all as specified & directed.
S&F in repair 25mm dia aluminium powder coated Drapry rod fixed with decorated polished wooden brackets and wooden end knobs complete all as directed and specified
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 6 amps on independent board but below the switch board in same vertical plane
(c) One point for socket outlet 6 amps on independent board but not below the switch board in same vertical plane
(d) One point for socket outlet 5 amp same board
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
(f) One bell / buzzer point controlled by one push button on the same board with other switches
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F switch piano flush type, 6 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 6 amp flush type complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 6 and 16 amp flush type complete all as specified & directed.
S & F bell push button type single pole one way 06 Amps .
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified & directed.
S & F Call bell ding dong type AC 230 volts, single pole complete all as specified ad directed.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed for the following sizes :-. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
(a) 2x4.0 sq. mm + 1x2.5 sq. mm earth wire
(b) 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers as specified and directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.as specified or directed by Engr-in- Charge.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
M & L for cutting & chasing required exceeding 20 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
M & L for cutting & chasing required not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 600 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate) (i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 400 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 125 Amp - 01 No (iv) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 01 No (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate) (i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 125 Amp - 01 No (iv) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 01 No (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep and getting out and laying LT UG Cable complete all as specified and directed .
Returning filling in with the soil obtained from item above here-in-before includiing spreading , leveling and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
Supply, fixing ( in replacement ), connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete (f) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No,Make of MCCB : L&T, Havells, Schneider.
S&F steel tubular electric pole, swaged type, welded (9 metre long) single swan neck type along with bracket, complete with CI base plate, bolts, nuts & screws all as specified including the following:- (a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres. (b) M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL (c) M&L for Providing PCC 1:3:6, type C2 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia (d) M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block.
S&F PVC insulated PVC sheathed stranded copper conductor cable 1.5 Sqmm three core complete all as specified and directed.
S&F rigid PVC conduite 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed.
Supply, fixing, connecting, & testing LED streetlight fitting of 70/72 Watt high pressure die cast aluminium housing, with minimum 110 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed.Make- Philips cat part No. BRP062 LED 84 CW SLC S1 PSU or equivalent in Havells cat part No. ENDURAPEARLPLUS70WLED757SASYTOPC/ Crompton cat part No. LST-70-CDL-M or as approved.
S& F Pole box junction three phase of size 297x 250 x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint, and inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 kA 240 volt complete all as specified and directed.
M&L for earthing of galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
Supply & fixing Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. Make:Indo asian/ Havells/Hager or as approved
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 63/100 Amp poles, conforming to IS 8828/IEC 60898-1 and current carrying capacity in the DB complete with connection testing and commissioning as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T or as approved.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
Siddhi Constructionn
M/S PRAMOD SINGH ASSOCIATE
M/S Garg Sons
M/S A P CONSTRUCTION
Technological Associates
SAP ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .