| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.9 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹1.1 Cr+₹9.0 L (9.18%)Rejected-Finance A 1 DEEPMALA BUNGLOW CADILLA ROAD GODASAR AHMEDABAD CITY | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹1.1 Cr+₹10.8 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹1.1 Cr+₹15.3 L (15.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Allahabad
HQ CWE New Cantt Allahabad
PROVISION OF RECYCLING OF TREATED SEWAGE WATER FOR ARBORICULTURE, CARDENING AND WATERING OF TRG GROUND AT CERTAIN POCKETS IN AYODHYA CANTT UNDER AGE (I) AYODHYA.
2023_MES_595924_1
81746/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE Ayodhya
₹2.1 L
Yes
13 Jul 2023
16 May 2023
1 Jul 2023
17 May 2023
29 Jun 2023
15 Jun 2023
Amount
Excavation over area n.exc 1.50m deep and getting out in any type of soil complete all as specified and directed.
All as per item No. 1.00 but exc each additional depth of 1.50m or part thereof in depth beyond the first 1.50m complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling, sub base of floor and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) as in foundation, raft footing, plinth beams, bases of columns and the like complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) as in walls, retaining walls, basement walls, ballast walls and the like in any thickness above top of the footing including attached pilasters and buttresses complete all as specified and directed.
M&L for form work to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc vertical or to better for fair finished surface complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply, installation, testing and commissioning of Set of two monobloc pumps of following capacities, operating on three phase AC power supply, mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with inlet/ outlet butterfly valve, dual plate check valve, common header, interconnecting cable, and required foundation with weather protecting FRP canopy, complete in all respect. Each set has to be provided with displacer type level sensor and at outlet of each set pressure switch to be provided for automatic operation of pumps complete all as specified and directed.
6.36 LPS at 40 m head.
3.18 LPS at 57 m head.
3.18 LPS at 63 m head.
Supply, installation, testing and commissioning of Set of two monobloc pumps of following capacity, two stage, operating on three phase AC power supply, mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with inlet/ outlet butterfly valve, dual plate check valve, common header, interconnecting cable, and required foundation with weather protecting FRP canopy, complete in all respect, each set has to be provided with displacer type level sensor and at outlet of each set pressure switch to be provided for automatic operation of pumps complete all as specified and directed.
3.10 LPS at 90 m head
Supply, installation, commissioning and testing of electrical panel (outdoor type) double door type cubical type made out of CRCA sheet 3 mm thick dust and vermin proof with aluminium busbar of 100 amps capacity and angle iron size of 30x30x4 mm. Panel should be covered from all side with front lockable door and hinges and powder coated, grouted in and including PCC 1:3:6 with 20 mm graded stone aggregarte type B-1 complete including supply and fixing of following accessories:- (a) MCCB TPN 50 amps, 4 pole, 415 Volt of breaking capacity not less than 16 KA - 01 No incomer. (b) Star Delta starter complete with cont5actor and relays & Single phase preventer suitable for 15 HP motor - 2 nos. (c) Indicator lamp (R,Y,B). (d) Digital Ammeter with suitable ratio of CTs. (e) Digital Volt meter. (f) Internal Wiring and connecting the switchgears and accessories. (g) MCB TP 16 Amps, 415V, 10KA=02 Nos.
Supply, installation, commissioning and testing electrical panel double door type cubical type made out of CRCA sheet 3 mm thick dust and vermin proof with aluminium busbar of 100 amps capacity and angle iron size of 30x30x4 mm. Panel should be overed from all side with front lockable door and hinges and powder coated. grouted in and including PCC 1:3:6 with 20 mm graded stone aggregate type B-1 complete including supply and fixing of following accessories:- (a) MCCB TPN 32 amps, 4 pole, 415 Volt of breaking capacity not less than 10 KA- 01 No incomer. (b) Star Delta starter complete with contactor and relays & Single phase preventer suitable for 7.5 HP motor - 2 nos. (c) Indicator lamp (R,Y,B). (d) Digital Ammeter with suitable ratio of CTs. (e) Digital Volt meter. (f) Internal wiring and connecting the switchgears and accessories. (g) MCB TP 16 Amps, 415V, 10KA=02 Nos.
Supply, installation, commissioning and testing of electrical panel (outdoor type) double door type cubical type made out of CRCA sheet 3 mm thick dust and vermin proof with aluminium busbar of 100 amps capacity and angle iron size of 30x30x4 mm. Panel should be covered from all side with front lockable door and hinges and powder coated, grouted in and including PCC 1:3:6 with 20 mm graded stone aggregate type B-1 complete including supply and fixing of following accessories:- (a) MCCB TPN 50 amps, 4 pole, 415 Volt of breaking capacity not less than 16 KA- 01 No incomer. (b) Star Delta starter complete with contactor and relays & Single phase preventer suitable for 10 HP motor - 4 nos. (c) Indicator lamp (R,Y,B). (d) Digital Ammeter with suitable ratio of CTs. (e) Digital Volt meter. (f) Internal wiring and connecting the switchgears and accessories. (g) MCB TP 16 Amps, 415V, 10KA=02 Nos. Note for item No. 12 to 14 Electrical Panel :Each Panel shall be having following safeties and controls. (a) With Single/Reverse phasing protection. (b) With automatic controlling of pump set ON/Off Condition via displacer type level sensor depending upon water level in UG Sump. (c) With automatic controlling of pump set ON/Off Condition via pressure switch depending upon water pressure in feed line.
Supply and lay HDPE Pipe - PE 63/SDR 21 as per IS 4984-2016, ISI marked, in trenches/walls or laying in floors of following sizes including all fittings complete all as specified and directed.
110 MM OD pipe.
125 MM OD pipe.
Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PPR pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls or laying in floors of following sizes including all fittings complete all as specified and directed.
90 MM OD pipe.
40 MM OD pipe.
Material & labour for masonry valve chamber, TYPE 'A' of Size 500mm x 500mm x 500 mm including PCC (1:4:8) type D2 for foundation & floor, brick work in CM (1:4), internal & external plaster 10 mm in CM (1:4) complete all as per standard details and as specified and directed.
Supply & fixing PPR gate valve suitable for PPR pipe of following Diameter complete all as specified and directed :-
S&F POP UP golf course Sprinkler, Large Area Coverage, Discharge: 134 to 261 lpm Wetted Radius: 21 to 26 m Operating Pressure: 4.0 to 4.5 Kg/cm2 Threaded Usability: Quick Connect Assembly complete all as specified and directed.
S&F PVC braided hose pipe of 40 mm dia suitable for 4 Kg/cm2 pressure complete all as specified and directed.
M&L for road cutting 0.75 m width and 1.2 m depth for laying and dismantling of DI/CI pipes and making good the disturbed surfaces including returning filling and PCC 1:3:6 upto a depth of 20 cm from road surface and removing of soil upto 50 m complete all as specified and directed.
Supplying, laying, commissioning & testing LT underground cable 16 Sqmm 4 core 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098 (Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp etc complete all as specified and directed .
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed . Note:- Punned thickness only shall be measured & paid.
Supply & laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of under ground cable complete all as specified and directed .
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified and directed.
Removing excavated (soil), material n.exc 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for returning filling in soft/loose soil, incl spreading levelling watering and well ramming in layers n exc 25 cm complete all as specified and directed.
M&L for hardcore of broken bricks or boulders n.exc 15cm thick of gauge n.exc 63mm, deposited, sprayed and levelled in layers n.exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed.
M&L for 75mm thick plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in and the like finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
A ONE ENGINEERING
Channa Brothers and Co.
DEORA ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .