Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹17.5 L
Closing Date
14 Oct 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PR & CC
SUPPLY, SUPERVISION AND INSTALLATION OF 1000 SUBMERSIBLE TURBINE PUMPS AT HPCL
20000441-HD-10157
20000441-HD-10157
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
₹17.5 L
14 Oct 2020
21 Sept 2020
14 Oct 2020
14 Oct 2020
23 Sept 2020 - 6 Oct 2020
29 Sept 2020
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 2 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 3 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 4 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 5 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 6 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 7 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 8 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. 9 STP 0.75 HP125 INCH 11751-BANGALORE RETAIL RO Each 200 84131191 29AAACH1 Yes 118B1Z8 SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
| 10 | STP 0.75 HP125 INCH | STP 0.75 HP125 INCH — SUBMERSIBLE TURBINE PUMP; LIQUID HANDLED:PETROL AND DIESEL; DELIVERY RATE:180-190 LPM; LEAK DETECTOR:MLLD SUITABLE FOR PETROL AND DIESEL; OPERATING TEMPERATURE RANGE:-25 TO 50 DEG C; OPERATING HUMIDITY RANGE:MAXIMUM 95%; OPERATING ENVIRONMENT:TROPICAL CONDITIONS AND IN OPEN ATM.; MOTOR POWER:0.75 HP; MOTOR TYPE:FIXED SPEED; POWER SUPPLY:220 +- 10% VOLTS, 50 HZ; NUMBER OF PHASES:SINGLE; SUCTION LIFT: A SINGLE TELESCOPIC TYPE COLUMN PIPE OF VARIABLE LENGTH 76 TO 125 INCH TO BE PROVIDED TO SUIT THE INSTALLATION FOR VARIOUS DIAMETER TANKS UP TO 2.27 METERS, VENDOR TO PROVIDE DETAILS OF VARIABLE LENGTH AND RISERS FOR THE ABOVE VARIANTS. STANDARD CONTROL BOX FOR OPERATION OF STPS SHOULD BE PROVIDED. RELAY BOX FOR COMMUNICATING BETWEEN DISPENSERS AND STPS – SWITCHING ON AND OFF SUITABLE FOR 8 NOZZLES. REUSABLE 0.2 MM SIZE TRAPPER FILTER TO BE PROVIDED. EXPECTED POWER FLUCTUATE IS BETWEEN 180 VOLTS TO 250 VOLTS. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
20000441-HD-10157.pdf
TENDER_DOCUMENT • 10.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .