Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹13.1 L+₹28,196 (2.20%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹13.5 L+₹67,736 (5.29%)Rejected-AOC | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹14.7 L+₹1.9 L (14.8%)Rejected-AOC WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-AOC Being L4 | |
| 5 | L5₹14.8 L+₹2.0 L (15.3%)Rejected-AOC | L5 | Rejected-AOC Being L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Apr 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY EXTERNAL WATER SUPPLY COMPLAINTS AT MOUDE ROAD AREA ARJUN VIHAR CARRIAPPA VIHAR AREA PRATAP CHOWK KHYBER LINES MANEKSHAW CENTRE COMPLEX BAIRD PLACE AND ALLIED AREA IN THE AREA OF AGE U WATER SUPPLY NO II
2020_MES_329579_1
GE/WS/D-68 OF 2019-20
Open Tender
Civil Works
Item Rate
270 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹40,000
Yes
18 May 2020
28 Feb 2020
13 Apr 2020
28 Feb 2020
11 Apr 2020
13 Mar 2020
Amount
Labour only for Attending day to day external water supply complaints of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply including noting the complaints in complaint register complete all as specified and as directed.
Labour only for attending day to day Electrical Supply Complaints (including sunday & Holidays) maintenance of existing LT panels including connecting electrical accessories/spares of water supply installations, electric fittings with lights, short circuits in pump house including noting the complaints in complaint register complete all as specified and as directed.. Note for srl No 1 & 2 :- Material required for attending complaints shall be measured & paid separately under respectvie items here-in-after.
Notes for Srl No. 1 & 2 :- The rates quoted by the contractor shall also deemed to be included for the following :- (i) The complaints shall be attended and the defects shall be rectified by a team of One Experienced Electrician and One Experienced Plumber assisted with One number of helper, matriculation passed qualified having minimum 03 years experience . (ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from Contractor's dues. (iii) In case , after checking & attending the defect,if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractor's view, no recovery will be made.
(iv) While attending the complaint of water supply/Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'/BOQ. However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job quoted rates (Fittings and fixtures shall be measured and paid separetely under respective items of Sch A/BOQ). (vi) All T&P required for attending the complaints shall be provided by the contractor without any extra. (vii) The pipe fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc..,as required at site. (viii) The electrician shall always be in possession of all electrician tools, LT megger, Earth tester, multimeter, crimping tool, insulation tape, hand gloves etc. as required at site.
Supply only GI Socket, medium grade, ISI Marked complete all as specified and as directed of following sizes.
GI Socket 15 mm bore
GI Socket 20 mm bore
GI Socket 25 mm bore
GI Socket 40 mm bore
GI Socket 50 mm bore
Supply only GI Elbow, medium grade, ISI Marked complete all as specified and as directed of following sizes.
GI Elbow 15 mm bore
GI Elbow 20 mm bore
GI Elbow 25 mm bore
GI Elbow 40 mm bore
GI Elbow 50 mm bore
Supply only GI Union, medium grade, ISI Marked complete all as specified and as directed of following sizes.
GI Union 15 mm bore
GI Union 20 mm bore
GI Union 25 mm bore
GI Union 40 mm bore
GI Union 50 mm bore
Supply only GI Nipple of different length as per requirement, both ends screwed, medium grade, ISI Marked complete all as specified and as directed of following sizes.
GI Nipple 15 mm bore
GI Nipple 20 mm bore
GI Nipple 25 mm bore
GI Nipple 40 mm bore
GI Nipple 50 mm bore
Supply only GI reducing socket, medium grade, ISI Marked complete all as specified and as directed of following sizes.
GI reducing socket size 20 x15 mm bore
GI reducing socket size 25 x15 mm bore
GI reducing socket size 25 x20 mm bore
GI reducing socket size 40 x20 mm bore
GI reducing socket size 40 x25 mm bore
GI reducing socket size 50 x25 mm bore
Supply only GI Tee, Medium Grade, complete all as specified and as directed of following sizes
GI Tee , 15 x 15 x 15 mm bore
GI Tee , 20 x 20 x 15 mm bore
GI Tee , 20 x 20 x 20 mm bore
GI Tee , 25 x 25 x 15 mm bore
GI Tee , 25 x 25 x 20 mm bore
GI Tee , 25 x 25 x 25 mm bore
GI Tee , 40 x 40 x 20 mm bore
GI Tee , 40 x 40 x 25 mm bore
GI Tee , 40 x 40 x 40 mm bore
GI Tee , 50 x 50 x 20 mm bore
GI Tee , 50 x 50 x 25 mm bore
GI Tee , 50 x 50 x 40 mm bore
GI Tee , 50 x 50 x 50 mm bore
Supply only GI plug, solid, heavy duty, complete all as specified and as directed of following sizes.
GI plug, 15 mm bore
GI plug, 20 mm bore
GI plug, 25 mm bore
GI plug, 40 mm bore
GI plug, 50 mm bore
Supply Only PVC 'L' type holder, suitable for aluminium rod, float ball, of following size bore complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only PTMT float valve, Sizes as under, with epoxy coated aluminium rod and high density plastic ball complete all as specified and as directed.
PTMT float valve, 15 mm bore
PTMT float valve, 20 mm bore
PTMT float valve, 25 mm bore
PTMT float valve, 40 mm bore
PTMT float valve, 50 mm bore
Supply Only Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 and fixed including taking out unserviceable one, complete all as specified and as directed of following sizes.
Gun metal gate valve, 15 mm bore
Gun metal gate valve, 20 mm bore
Gun metal gate valve, 25 mm bore
Gun metal gate valve, 40 mm bore
Gun metal gate valve, 50 mm bore
Supply Only Gun metal air release valve, 25 mm bore as per IS complete all as specified and as directed.
Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
Supply Only 25 to 150 mm long, 6 to 20 mm dia nuts, bolts & washers complete all as specified and as directed. Note for Srl No 03 to 15 : Rate for taking down/out existing fittings and fixtures and refixing to make it functional shall be taken into account under Srl No 1 &2 here-in-before.
Supply Only lead pig bar complete all as specified and as directed.
Supply Only Spurn Yarn complete all as specified and as directed.
Supply Only Lead wool complete all as specified and as directed.
Supply only M-seal in 500 gm pack complete all as specified and as directed.
Taking up or down GI steel tubing of following sizes with connections from Trenches/floors/walls including cleaning for refixing or removal complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Refixing/ relaying, jointing and testing old GI steel tubing of following sizes, retrieved under srl No 20 here-in-before in new or old position at walls,ceiling or floor etc including cleaning or rerunning the old screw threads, with & including providing new GI fittings complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supplying, Laying and Testing of GI steel tubing medium grade of following size in old or new position as in Trenches/ceiling/walls/Floors with necessary fixing arrangements and including providing new GI fittings complete all as specified and as directed. Note :- Excavation for new location shall be measured & paid separetely.
GI steel tubing, 15 mm bore
GI steel tubing, 20 mm bore
GI steel tubing, 25 mm bore
GI steel tubing, 40 mm bore
GI steel tubing, 50 mm bore
Taking up or down CI/DI Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lad joints and recovering lead and including cleaning for refixing or removal complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separetely.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Laying only in Trenches CI/DI Pipes of following sizes with spigot and socketed ends, cleaning thoroughly and removal of all blockages if any, complete all as specified and as directed.(old serviceable pipe shall be obtained from Item no. 23) Note:- Joints and CI fittings shall be measured & paid separetely.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, Laying, jointing, testing and commmisioning DI Pipe of following sizes as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed . Note:- (i) Joints shall be measured & paid separetely. (ii) Fittings , if any shall be measured and paid separately.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
M&L for laying and jointing CI Fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars,tail pieces,caps and plugs Upto 200 mm bore conforming to IS: 1538-1993 complete all as specified and as directed.
Labour Only for run lead joint for CI/DI Pipe of following size/Bore complete all as specified and as directed . Note:- lead and spurn yarn shall be measured and paid as supply only.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Opening of existing sluice valve including opening of gland cover taking out with stem nut of brass or of stainless steel & refexing the same after with & including replacement of rubber packing, nut & bolts, glands dori etc complete all as specified and as directed of following sizes. Note:- Spare parts under relevant items shall be measured and paid separately under respective items.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem' made out from stainless steel of sluice valve of following sizes, complete all as specified and as directed.
Stem, 80 mm bore
Stem, 100 mm bore
Stem, 150 mm bore
Stem, 200 mm bore
Supply only 'Stem Nut' made out from stainless steel suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed.
Stem Nut, 80 mm bore
Stem Nut, 100 mm bore
Stem Nut, 150 mm bore
Stem Nut, 200 mm bore
Supply only 'Gland Plate' made out from Cast Iron suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed.
Gland Plate, 80 mm bore
Gland Plate, 100 mm bore
Gland Plate, 150 mm bore
Gland Plate, 200 mm bore
Taking out/down suction pipe 80 mm to 200 mm bore from sump, of any capacity, dismantling of foot valve screwed / flanged type and re-lowering after refixing in position the same duly cleaned / minor repair, if any, required such as replacement of rubber gasket/ lifting bolts & nuts and making thread for the suction pipes off sizes etc complete all as specified and as directed.
Supply and fixing copper made bottle neck type thimble suitable for 16 Sqmm cable complete all as specified and as directed.
Supply and fixing copper made bottle neck type thimble suitable for 25 Sqmm cable complete all as specified and as directed.
Supply and fixing copper made bottle neck type thimble suitable for 35 Sqmm cable complete all as specified and as directed.
Supply and fixing copper made bottle neck type thimble suitable for 50 Sqmm cable complete all as specified and as directed.
Supply and fixing aluminium cable lux suitable for 16 Sqmm cable complete all as specified and as directed.
Supply and fixing aluminium cable lux suitable for 25 Sqmm cable complete all as specified and as directed.
Supply and fixing aluminium cable lux suitable for 35 Sqmm cable complete all as specified and as directed.
Supply and fixing aluminium cable lux suitable for 50 Sqmm cable complete all as specified and as directed.
Refilling of fire extinguisher CO2 type, 9 kg capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Refilling of fire extinguisher CO2 type, 4.5 kg capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Refilling of fire extinguisher CO2 type, 3 kg capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Refilling of fire extinguisher dry chemical powder type, 5 kg capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Refilling of fire extinguisher mechanical foam type, 9 litres capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Refilling of fire extinguisher with ABC powder, 5 kg capacity, in the cylinder after taking down/out existing cylinder from any location & refixing the same after minor repair to make it functional complete all as specified and as directed.
Supply and fixing in replacement XLPE cable insulated screened PVC bedded galvanized steel strip or wire, armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 16 sqmm, 4 core laid in trenches/ crossing the dispersal/culverts/fixed on panels/walls complete all as specified and as directed.
Supply and fixing in replacement XLPE cable insulated screened PVC bedded galvanized steel strip or wire, armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 25 sqmm, 4 core laid in trenches/ crossing the dispersal/culverts/fixed on panels/walls complete all as specified and as directed.
Supply and fixing in replacement XLPE cable insulated screened PVC bedded galvanized steel strip or wire, armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 35 sqmm, 3.5 core laid in trenches/ crossing the dispersal/culverts/fixed on panels/walls complete all as specified and as directed.
Taking down existing LT/UG cable 25/35 sqmm 3.5 core from existing trench and finding fault and laying back complete all as specified and directed. Note: Excavation, Earthwork and protection materials will be measured and paid separately under relevant item.
Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 16 sqmm, 4 core after taking down/out faulty portion as exists complete all as specified and as directed.
Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 25/35 sqmm, 3.5 core after taking down/out faulty portion as exists complete all as specified and as directed.
Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable, heavy duty, 1100 volts grade with stranded aluminium conductor , cross sectional area 95 sqmm, 3.5 core after taking down/out faulty portion as exists complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles
PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregates as in foundation, sub base and mass concrete complete all as specified & as directed.
PCC 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates as in coping, grouting MS frame etc including form work complete all as specified and as directed..
Rendering 15mm thick in CM 1:4 on fair faces of brick wall/concrete surfaces and finished fair & even complete all as specified and as directed..
Material and labour for brick work with Sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
Supply and fixing for mild steel work for manhole cover, stair case steps made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed.
Pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situation, taking down/out the faulty portion of cable , of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work ,sand cushioning and making necessary connections to make it functional complete all as specified and as directed. Note :- (i) Cable jointing kit shall be measured & paid seperetely. (ii) Old retrieved bricks/cable cover shall be reused. (iii) The rates quoted includes excavation & earth work with sand cushioning.
Taking down/out existing unserviceable exhaust fan upto 450mm sweep with or without louvers, from any location/position, of any make, for repair including replacement of rotor, bearing and winding with suitable size copper wire of existing wt & gauge etc , replacement of minor spare parts such as nuts,bolts & washers , applying two coats of synthetic enamel white paint , making good the disturbed portion to match with the existing surface , refixing at location as directed and making necessary connections with twisted copper flexible wire 23/0.0076mm to make it functional complete all as specified and as directed.
Supply and fix in repairs exhaust fan mesh made out of 3mm thick welded steel wire fabric and 25 mm flat iron of size 0.60mx0.60m completely fixed on wall minimum 10m height from ground level complete all as specified and as directed.
Supply and laying sub class 'B' bricks old sizes over the LT cable laid flat for protection of cable complete all as specified and as directed.
Supplying and laying for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
M&L for cleaning of basement pit chamber of water storage capacity 3000 Ltrs throughly bt removing mud, grits etc complete all as specified.
M&L for cleaning of basement pit chamber of water storage capacity 6000 Ltrs throughly bt removing mud, grits etc complete all as specified. Note For srl item no. 84 & 85:- Rate quoted shall be deemed to include cleaning inner surfaces of tank complete by scrapping with steel wire brushes, pressure wash, removinn mud, sludge collected inside the tank manually to a distance not exceeding 50 mtrs.
Supply and fixing of 15 mm dia Sprinkler glass bulb type standard responseas per IS-15106/TAC guidelines 68 degree rating pendent type make including taking out unserviceable one complete all as specified and as directed..
Supply, fixing, jointing and testing of Cast iron Non Return valve 50 mm without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
Testing of drinking water collected from local source (bore wells /shallow wells) in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells)
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Surface dressing of uneven surfaces of natural ground, rough excavated surfaces not exceeding 15 cm deep and filled area where ordered shall be trimmed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. complete all as specified and as directed.
M&L for DI fittings/specials such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs Upto 200 mm bore confirming to IS: 9523 complete all as specified and as directed. Note:- Tyton joints shall be measured and paid seperately.
Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of sizes as under complete all as specified and as directed.
An amount of Rs 61995.00 shall be deducted from BOQ on account of schedule of credit
Rahul Enterprises
Microsys Controls India
Tushar engineers
Ashish Sehgal and Co.
somyaenterprises
triveni enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .